Claire Corot
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Claire Corot has a total of 106 co-authors. Here are the top co-authors by number of shared publications:
E. Lancelot
3 shared publicationsB Bonnemain
2 shared publicationsD Meyer
2 shared publications- Jean-Sébastien Raynaud
Guerbet BP57400, 95943 Roissy CDG Cedex, France
2 shared publications M Schaefer
2 shared publications- Marc Port
Recherche Guerbet, Roissy, France
2 shared publications
Latest Publications
- 1 December 2015
- Published by Elsevier in Regulatory Toxicology and Pharmacology
- Vol. 73 (3) , 960-970
Non-clinical safety assessment of gadoterate meglumine (Dotarem®) in neonatal and juvenile rats
- 1 December 2015
- Published by Elsevier in Regulatory Toxicology and Pharmacology
- Vol. 73 (3) , 960-970
Non-clinical safety assessment of gadoterate meglumine (Dotarem®) in neonatal and juvenile rats
- 1 December 2014
- Published by Elsevier in Reproductive Toxicology
- Vol. 50, 171-179
Safety profiles of gadolinium chelates in juvenile rats differ according to the risk of dissociation
- 1 December 2014
- Published by Elsevier in Reproductive Toxicology
- Vol. 50, 171-179
Safety profiles of gadolinium chelates in juvenile rats differ according to the risk of dissociation
- 1 June 2013
- Published by Elsevier in Atherosclerosis
- Vol. 228 (2) , 339-345
Monitoring plaque inflammation in atherosclerotic rabbits with an iron oxide (P904) and 18F-FDG using a combined PET/MR scanner
- 1 June 2013
- Published by Elsevier in Atherosclerosis
- Vol. 228 (2) , 339-345
Monitoring plaque inflammation in atherosclerotic rabbits with an iron oxide (P904) and 18F-FDG using a combined PET/MR scanner
- 30 April 2013
- Published by Wiley in WIREs Nanomedicine and Nanobiotechnology
- Vol. 5 (5) , 411-422
Superparamagnetic iron oxide nanoparticles for MRI: contrast media pharmaceutical company R&D perspective
Superparamagnetic iron oxide (SPIO) nanoparticles are a relatively large class of contrast agents for magnetic resonance imaging. According to their biodistribution, distinct classes of SPIO nanoparticles have been investigated for clinical applications either as macrophage imaging agents or blood pool agents. Contrast agents which are pharmaceutics followed the same development rules as therapeutic drugs. Several drawbacks such as clinical development difficulties, organization of market access and imaging technological developments have limited the widespread use of these products. SPIO nanoparticles that are composed of thousands iron atoms providing large T2* effects are particularly suitable for theranostic. Stem cell migration and immune cell trafficking, as well as targeted SPIO nanoparticles for molecular imaging studies are mainly at the stage of proof of concept. A major economic challenge in the development of molecular imaging associated with a therapeutic treatment/procedure is to define innovative business models compatible with the needs of all players taking into account that theranostic solutions are promising to optimize resource allocation and ensure that expensive treatments are prescribed to responding patients. WIREs Nanomed Nanobiotechnol 2013. doi: 10.1002/wnan.1225This article is categorized under: Diagnostic Tools > Diagnostic Nanodevices Diagnostic Tools > In Vivo Nanodiagnostics and Imaging Toxicology and Regulatory Issues in Nanomedicine > Regulatory and Policy Issues in Nanomedicine
- 30 April 2013
- Published by Wiley in WIREs Nanomedicine and Nanobiotechnology
- Vol. 5 (5) , 411-422
Superparamagnetic iron oxide nanoparticles for MRI: contrast media pharmaceutical company R&D perspective
Superparamagnetic iron oxide (SPIO) nanoparticles are a relatively large class of contrast agents for magnetic resonance imaging. According to their biodistribution, distinct classes of SPIO nanoparticles have been investigated for clinical applications either as macrophage imaging agents or blood pool agents. Contrast agents which are pharmaceutics followed the same development rules as therapeutic drugs. Several drawbacks such as clinical development difficulties, organization of market access and imaging technological developments have limited the widespread use of these products. SPIO nanoparticles that are composed of thousands iron atoms providing large T2* effects are particularly suitable for theranostic. Stem cell migration and immune cell trafficking, as well as targeted SPIO nanoparticles for molecular imaging studies are mainly at the stage of proof of concept. A major economic challenge in the development of molecular imaging associated with a therapeutic treatment/procedure is to define innovative business models compatible with the needs of all players taking into account that theranostic solutions are promising to optimize resource allocation and ensure that expensive treatments are prescribed to responding patients. WIREs Nanomed Nanobiotechnol 2013. doi: 10.1002/wnan.1225This article is categorized under: Diagnostic Tools > Diagnostic Nanodevices Diagnostic Tools > In Vivo Nanodiagnostics and Imaging Toxicology and Regulatory Issues in Nanomedicine > Regulatory and Policy Issues in Nanomedicine
- 16 December 2011
- Published by Elsevier in Annales Pharmaceutiques Françaises
- Vol. 70 (1) , 26-34
Applications de l’imagerie pour l’étude de la biodistribution et du métabolisme de nouvelles molécules
- 16 December 2011
- Published by Elsevier in Annales Pharmaceutiques Françaises
- Vol. 70 (1) , 26-34
Applications de l’imagerie pour l’étude de la biodistribution et du métabolisme de nouvelles molécules
- 30 June 2010
- Published by Elsevier in Atherosclerosis Supplements
- Vol. 11 (2) , 182
MS360 ANTI-ANGIOTENSIN DRUG EVALUATION IN apoE−/− MICE BY USPIO-ENHANCED MRI AT 7 T
- 30 June 2010
- Published by Elsevier in Atherosclerosis Supplements
- Vol. 11 (2) , 182
MS360 ANTI-ANGIOTENSIN DRUG EVALUATION IN apoE−/− MICE BY USPIO-ENHANCED MRI AT 7 T
- Open Access
- 24 November 2008
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 60 (6) , 1337-1346
Tumor imaging using P866, a high‐relaxivity gadolinium chelate designed for folate receptor targeting
The objective of this study was to evaluate the potential of a high‐relaxivity macromolecular gadolinium (Gd) chelate to target folate receptors (FRs). P866 is a dimeric high‐relaxivity Gd chelate coupled to a folate moiety. Binding affinity, in vivo biodistribution studies in KB tumor‐bearing mice at 1, 4, and 24 h, and dynamic contrast‐enhanced (DCE)‐MRI (2.35 T) over 4 h were assessed. Binding and internalization of P866 through the FR was demonstrated. Due to the high molecular volume of P866, the binding affinity compared to free FA was decreased (KD = 59.3 ± 1.8 nM and 5.9 ± 0.2 nM, respectively). Tumor/muscle (T/M) uptake was 5.4 ± 1.0, 4 h after injection of 15 μmol/kg. Competition with free FA was less effective when the dose was increased due to a saturation of FR. At a dose of 5 μmol/kg, a 70% difference in signal enhancement was observed between P866 and the nonspecific reference compound, thus demonstrating the specificity of FR targeting. While this high‐relaxivity folate‐Gd chelate has demonstrated its potential capacity to target in vivo FR on tumors, the sensitivity is probably limited to a certain extent by the saturation of the FR and by the decrease in the apparent relaxivity of the internalized part of P866 in the tumor cells. Magn Reson Med 60:1337–1346, 2008.
- 24 November 2008
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 60 (6) , 1337-1346
Open AccessTumor imaging using P866, a high‐relaxivity gadolinium chelate designed for folate receptor targeting
The objective of this study was to evaluate the potential of a high‐relaxivity macromolecular gadolinium (Gd) chelate to target folate receptors (FRs). P866 is a dimeric high‐relaxivity Gd chelate coupled to a folate moiety. Binding affinity, in vivo biodistribution studies in KB tumor‐bearing mice at 1, 4, and 24 h, and dynamic contrast‐enhanced (DCE)‐MRI (2.35 T) over 4 h were assessed. Binding and internalization of P866 through the FR was demonstrated. Due to the high molecular volume of P866, the binding affinity compared to free FA was decreased (KD = 59.3 ± 1.8 nM and 5.9 ± 0.2 nM, respectively). Tumor/muscle (T/M) uptake was 5.4 ± 1.0, 4 h after injection of 15 μmol/kg. Competition with free FA was less effective when the dose was increased due to a saturation of FR. At a dose of 5 μmol/kg, a 70% difference in signal enhancement was observed between P866 and the nonspecific reference compound, thus demonstrating the specificity of FR targeting. While this high‐relaxivity folate‐Gd chelate has demonstrated its potential capacity to target in vivo FR on tumors, the sensitivity is probably limited to a certain extent by the saturation of the FR and by the decrease in the apparent relaxivity of the internalized part of P866 in the tumor cells. Magn Reson Med 60:1337–1346, 2008.
- Top Cited Papers
- 1 December 2006
- Published by Elsevier in Advanced Drug Delivery Reviews
- Vol. 58 (14) , 1471-1504
Recent advances in iron oxide nanocrystal technology for medical imaging☆
- 1 December 2006
- Published by Elsevier in Advanced Drug Delivery Reviews
- Vol. 58 (14) , 1471-1504
Top Cited PapersRecent advances in iron oxide nanocrystal technology for medical imaging☆
- 7 November 2006
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 178 (11) , A28
Evaluation des makromolekularen Kontrastmittels P792 für die Kontrastmittel-verstärkte MR Angiographie im Tiermodell bei 3.0T im Vergleich zu 1.5T
Zielsetzung: Evaluation des intravaskulären Kontrastmittels P792 für die MR Angiographie (MRA) von Kaninchen bei 3.0T im Vergleich zu 1.5T. Material und Methoden: 11 weibliche und gleich alte Neuseeland-Kaninchen dienten als Versuchsmodell einer Vergleichsstudie zwischen zwei Dosen des Kontrastmittels P792 (13 und 25µmol/kg; n=4 pro Gruppe) und Gadoterat-Meglumin (Gd-DOTA; 100µmol/kg; n=3). Alle Tiere wurden einer Kontrastmittel-verstärkten MRA der Aorta abdominalis und ihrer Äste an zwei Terminen unterzogen, die in randomisierter Reihenfolge bei 3.0T und 1.5T unter Verwendung einer schnellen dreidimensionalen Gradienten-Echo-Sequenz und einer Oberflächenspule durchgeführt wurden. Die Datenakquisition erfolgte nativ sowie bis zu 10 Minuten nach intravenöser Kontrastmittel-Gabe. Die Bildqualität wurde auf einer 5-Punkte-Skala bewertet, zusätzlich wurden die Verhältnisse des Signal-zu-Rauschen (SRV) und Kontrast-zu-Rauschen (KRV) berechnet. Das Signifikanzniveau lag bei einem p-Wert Ergebnisse: P792 erlaubte die Akquisition hochwertiger MRA-Bilder in allen Fällen. In den ersten Minuten nach Kontrastmittel-Gabe war die Bildqualität in allen Gruppen sehr gut, zu späteren Zeitpunkten war P792 überlegen. Das SRV und KRV der höheren Dosis von P792 waren statistisch signifikant höher als von Gd-DOTA. Schlussfolgerung: P792 erscheint für eine qualitativ hochwertige MRA der Aorta von Kaninchen während der first-pass-Phase und der Äquilibrium-Phase bei einer magnetischen Feldstärke von 3.0T geeignet.
- 7 November 2006
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 178 (11) , A28
Evaluation des makromolekularen Kontrastmittels P792 für die Kontrastmittel-verstärkte MR Angiographie im Tiermodell bei 3.0T im Vergleich zu 1.5T
Zielsetzung: Evaluation des intravaskulären Kontrastmittels P792 für die MR Angiographie (MRA) von Kaninchen bei 3.0T im Vergleich zu 1.5T. Material und Methoden: 11 weibliche und gleich alte Neuseeland-Kaninchen dienten als Versuchsmodell einer Vergleichsstudie zwischen zwei Dosen des Kontrastmittels P792 (13 und 25µmol/kg; n=4 pro Gruppe) und Gadoterat-Meglumin (Gd-DOTA; 100µmol/kg; n=3). Alle Tiere wurden einer Kontrastmittel-verstärkten MRA der Aorta abdominalis und ihrer Äste an zwei Terminen unterzogen, die in randomisierter Reihenfolge bei 3.0T und 1.5T unter Verwendung einer schnellen dreidimensionalen Gradienten-Echo-Sequenz und einer Oberflächenspule durchgeführt wurden. Die Datenakquisition erfolgte nativ sowie bis zu 10 Minuten nach intravenöser Kontrastmittel-Gabe. Die Bildqualität wurde auf einer 5-Punkte-Skala bewertet, zusätzlich wurden die Verhältnisse des Signal-zu-Rauschen (SRV) und Kontrast-zu-Rauschen (KRV) berechnet. Das Signifikanzniveau lag bei einem p-Wert Ergebnisse: P792 erlaubte die Akquisition hochwertiger MRA-Bilder in allen Fällen. In den ersten Minuten nach Kontrastmittel-Gabe war die Bildqualität in allen Gruppen sehr gut, zu späteren Zeitpunkten war P792 überlegen. Das SRV und KRV der höheren Dosis von P792 waren statistisch signifikant höher als von Gd-DOTA. Schlussfolgerung: P792 erscheint für eine qualitativ hochwertige MRA der Aorta von Kaninchen während der first-pass-Phase und der Äquilibrium-Phase bei einer magnetischen Feldstärke von 3.0T geeignet.
- 1 May 2006
- Published by Bentham Science Publishers Ltd. in Anti-Inflammatory & Anti-Allergy Agents in Medicinal Chemistry
- Vol. 5 (2) , 139-146
Role of Apoptosis in the Pathogenesis of Contrast Media-induced Nephropathy and Hints for its Possible Prevention by Drug Treatment
Contrast-induced nephropathy (CIN) is a worrying concern in at-risk patients. Its pathophysiological mechanism remains speculative and is possibly modulated according to the risk factor(s) and clinical presentation of the patients. Overall, iodinated contrast media (CM) have been shown, in animal models, to induce medullary hypoxia. Furthermore, numerous studies have demonstrated that they have a direct cytotoxic potential on proximal (LLC-PK1) as well as distal (MDCK) tubular cell lines and mesangial cells. A pro-apoptotic potential of such molecules has been found on various cell types including renal tubular and mesangial cells, both in vitro and in vivo. This pro-apoptotic effect on tubular cells has been found to be concentration- and time-dependent. In addition to periprocedural hydration, which is the cornerstone of CIN, several drugs have been investigated for the pharmacological prophylaxis of CIN, either on pre-clinical models or in clinical studies. Some of them (theophylline, Nacetylcysteine, the prostacyclin analogue beraprost or taurine) are known to interfere with the apoptosis pathways. This article reviews and critically discusses the available data concerning the role of apoptosis in the mechanism of CIN and its pharmacological prophylaxis. It also reviews the putative interaction of gadolinium chelates, used as CM for magnetic resonance imaging, with apoptosis pathways.
- 1 May 2006
- Published by Bentham Science Publishers Ltd. in Anti-Inflammatory & Anti-Allergy Agents in Medicinal Chemistry
- Vol. 5 (2) , 139-146
Role of Apoptosis in the Pathogenesis of Contrast Media-induced Nephropathy and Hints for its Possible Prevention by Drug Treatment
Contrast-induced nephropathy (CIN) is a worrying concern in at-risk patients. Its pathophysiological mechanism remains speculative and is possibly modulated according to the risk factor(s) and clinical presentation of the patients. Overall, iodinated contrast media (CM) have been shown, in animal models, to induce medullary hypoxia. Furthermore, numerous studies have demonstrated that they have a direct cytotoxic potential on proximal (LLC-PK1) as well as distal (MDCK) tubular cell lines and mesangial cells. A pro-apoptotic potential of such molecules has been found on various cell types including renal tubular and mesangial cells, both in vitro and in vivo. This pro-apoptotic effect on tubular cells has been found to be concentration- and time-dependent. In addition to periprocedural hydration, which is the cornerstone of CIN, several drugs have been investigated for the pharmacological prophylaxis of CIN, either on pre-clinical models or in clinical studies. Some of them (theophylline, Nacetylcysteine, the prostacyclin analogue beraprost or taurine) are known to interfere with the apoptosis pathways. This article reviews and critically discusses the available data concerning the role of apoptosis in the mechanism of CIN and its pharmacological prophylaxis. It also reviews the putative interaction of gadolinium chelates, used as CM for magnetic resonance imaging, with apoptosis pathways.