Diego F. Cobice
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Diego F. Cobice has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Brian Robert Walker
University of Edinburgh
5 shared publications - Ruth Andrew
Clinical Division and Laboratory of Intensive Care Medicine, Department of Cellular and Molecular Medicine, and †Medical Intensive Care Unit, Department of Internal Medicine, Jessa Hospital, Hasselt, Belgium; and ‡Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom; and §Department of Laboratory Medicine, Jessa Hospital, Hasselt; and ∥Department of Pharmacy, KU Leuven, Leuven, Belgium
3 shared publications - Abdullah M M Faqehi
University/British Heart Foundation Centre for Cardiovascular Science, United Kingdom
2 shared publications - Gregorio Naredo
Mass Spectrometry Core, Wellcome Trust Clinical Research Facility, Queen's Medical Research Institute, University of Edinburgh, 47, Little France Crescent, Edinburgh EH16 4TJ, United Kingdom
2 shared publications - Natalie Z. M. Homer
Mass Spectrometry Core, Edinburgh Clinical Research Facility, Queens Medical Research Institute, University of Edinburgh, Edinburgh, UK
2 shared publications - Rita Upreti
Institute for Neuroscience and Cardiovascular Research, University of Edinburgh , Edinburgh EH16 4TJ
2 shared publications
Latest Publications
- 2 November 2018
- Published by Bioscientifica in Endocrine Abstracts
Time-dependent cortisol turnover in tissues using stable isotope tracers and MALDI Mass Spectrometry (MS) sampling
Excess action of glucocorticoid hormones is implicated in metabolic disease and cognitive decline, 11β-hydroxysteroid dehydrogenase 1 (11βHSD1) catalysing generation of active glucocorticoid hormones in tissues. The penetration rates and tissue-specific contribution of 11βHSD1 to glucocorticoid turnover were assessed using tracer kinetics. 9,11,12,12-d4-Cortisol (d4F) was infused (1.75 mg/day, 7 days) into C57Bl6/J male mice and mice lacking 11βHSD1 (n=3/group). Regeneration of d3F by 11βHSD1-mediated reduction was assessed in plasma by LC-MS/MS and in tissues using matrix assisted laser desorption ionisation (MALDI) MS. Mean±SEM. Circulating concentrations of d4F were 936±45 nM at 24 h, reducing to 566±63 nM at 48 h, and remaining steady until 7days, suggesting an initial stimulation of clearance (or changes in infusion rate). This pattern was mirrored in liver; d4F was detected at 6 h, increasing to 24 h and then plateaued at a lower level (~75% of 24 h) by 48 h. d4F was detectable in brain by 6 h, reaching steady state by 24 h, 3.5 fold lower than liver. Tracer was not detected in adipose until 24 h, remaining steady (4 fold lower than liver) until 7 days. D3F was detected in plasma, liver and brain at 6 h, but only after 48 h in adipose. Again in plasma and liver the amounts of d3F peaked at 24 h and declined to steady state at 48 h. D3F abundance in adipose and brain did not change from 24 h to 7days. Regeneration of d3F was abolished in mice lacking 11βHSD1, without changing circulating or tissue levels of d4F. Glucocorticoid regeneration of d3F is mediated solely by 11βHSD1 and circulating levels largely mirror hepatic production. Less glucocorticoid is regenerated in brain and adipose and levels are less dependent of the circulating pool, demonstrating the important contribution of the local enzyme and the importance of targeting therapies to specific tissues, such as brain.
- 2 November 2018
- Published by Bioscientifica in Endocrine Abstracts
Time-dependent cortisol turnover in tissues using stable isotope tracers and MALDI Mass Spectrometry (MS) sampling
Excess action of glucocorticoid hormones is implicated in metabolic disease and cognitive decline, 11β-hydroxysteroid dehydrogenase 1 (11βHSD1) catalysing generation of active glucocorticoid hormones in tissues. The penetration rates and tissue-specific contribution of 11βHSD1 to glucocorticoid turnover were assessed using tracer kinetics. 9,11,12,12-d4-Cortisol (d4F) was infused (1.75 mg/day, 7 days) into C57Bl6/J male mice and mice lacking 11βHSD1 (n=3/group). Regeneration of d3F by 11βHSD1-mediated reduction was assessed in plasma by LC-MS/MS and in tissues using matrix assisted laser desorption ionisation (MALDI) MS. Mean±SEM. Circulating concentrations of d4F were 936±45 nM at 24 h, reducing to 566±63 nM at 48 h, and remaining steady until 7days, suggesting an initial stimulation of clearance (or changes in infusion rate). This pattern was mirrored in liver; d4F was detected at 6 h, increasing to 24 h and then plateaued at a lower level (~75% of 24 h) by 48 h. d4F was detectable in brain by 6 h, reaching steady state by 24 h, 3.5 fold lower than liver. Tracer was not detected in adipose until 24 h, remaining steady (4 fold lower than liver) until 7 days. D3F was detected in plasma, liver and brain at 6 h, but only after 48 h in adipose. Again in plasma and liver the amounts of d3F peaked at 24 h and declined to steady state at 48 h. D3F abundance in adipose and brain did not change from 24 h to 7days. Regeneration of d3F was abolished in mice lacking 11βHSD1, without changing circulating or tissue levels of d4F. Glucocorticoid regeneration of d3F is mediated solely by 11βHSD1 and circulating levels largely mirror hepatic production. Less glucocorticoid is regenerated in brain and adipose and levels are less dependent of the circulating pool, demonstrating the important contribution of the local enzyme and the importance of targeting therapies to specific tissues, such as brain.
- 1 March 2014
- Published by Bioscientifica in Endocrine Abstracts
Derivatisation of estrogens enhances specificity and sensitivity of analysis by liquid chromatography tandem mass spectrometry
Physiological circulating concentrations of estrogens are very low in men and postmenopausal women (p-toluenesulfonate (FMP). Estrogen FMP derivatives were quantified using triple quadrupole MS in positive electrospray ionisation mode, following LC separation. Reaction conditions were optimised and the assay validated for linearity, precision, accuracy, and stability. Limits of detection and quantitation (LOD and LOQ) were evaluated. Transitions for the FMP derivatives of estrone (E1) and estradiol (E2) were compound specific (m/z 362→238 and m/z 364→110 respectively). The LOD was 2 pg/ml and the method was linear across the range 5–200 pg/ml. The values of intra- and inter-assay variables were acceptable at LOQ (5 pg/ml), precision (intra): 12%, 11% (inter): 15%, 13%; accuracy (intra): ±18%, ±17%, (inter): ±19%, ±19% for E1, E2 respectively. The derivatives demonstrated suitable stability over 24 h, (7–9% degradation). Using this approach, E1 and E2 were detected in human plasma (0.5 ml female, 1 ml male) at levels (7–9), (55–59) pg/ml in males and (78–84), (204–216) pg/ml in females for E1 and E2 respectively with signal to noise of 5–10. Here, we have demonstrated that FMP derivatisation in conjunction with LC–MS/MS is suitable for quantitative analysis of low abundance estrogens in biological fluids. The assay offers clear advantages in specificity and sensitivity over immunoassay and existing MS techniques for estrogens analysis.
- 1 March 2014
- Published by Bioscientifica in Endocrine Abstracts
Derivatisation of estrogens enhances specificity and sensitivity of analysis by liquid chromatography tandem mass spectrometry
Physiological circulating concentrations of estrogens are very low in men and postmenopausal women (p-toluenesulfonate (FMP). Estrogen FMP derivatives were quantified using triple quadrupole MS in positive electrospray ionisation mode, following LC separation. Reaction conditions were optimised and the assay validated for linearity, precision, accuracy, and stability. Limits of detection and quantitation (LOD and LOQ) were evaluated. Transitions for the FMP derivatives of estrone (E1) and estradiol (E2) were compound specific (m/z 362→238 and m/z 364→110 respectively). The LOD was 2 pg/ml and the method was linear across the range 5–200 pg/ml. The values of intra- and inter-assay variables were acceptable at LOQ (5 pg/ml), precision (intra): 12%, 11% (inter): 15%, 13%; accuracy (intra): ±18%, ±17%, (inter): ±19%, ±19% for E1, E2 respectively. The derivatives demonstrated suitable stability over 24 h, (7–9% degradation). Using this approach, E1 and E2 were detected in human plasma (0.5 ml female, 1 ml male) at levels (7–9), (55–59) pg/ml in males and (78–84), (204–216) pg/ml in females for E1 and E2 respectively with signal to noise of 5–10. Here, we have demonstrated that FMP derivatisation in conjunction with LC–MS/MS is suitable for quantitative analysis of low abundance estrogens in biological fluids. The assay offers clear advantages in specificity and sensitivity over immunoassay and existing MS techniques for estrogens analysis.
- Open Access
- 1 July 2013
- Published by Elsevier in Journal of Chromatography B
- Vol. 930, 121-128
Measurement of tamsulosin in human serum by liquid chromatography–tandem mass spectrometry
- 1 July 2013
- Published by Elsevier in Journal of Chromatography B
- Vol. 930, 121-128
Open AccessMeasurement of tamsulosin in human serum by liquid chromatography–tandem mass spectrometry
- Open Access
- 1 July 2013
- Published by Elsevier in Biochemical Pharmacology
- Vol. 86 (1) , 146-153
11β-Hydroxysteroid dehydrogenase type 1 contributes to the balance between 7-keto- and 7-hydroxy-oxysterols in vivo
- 1 July 2013
- Published by Elsevier in Biochemical Pharmacology
- Vol. 86 (1) , 146-153
Open Access11β-Hydroxysteroid dehydrogenase type 1 contributes to the balance between 7-keto- and 7-hydroxy-oxysterols in vivo