Alexander C. Wright
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Alexander C. Wright has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Andrew J. Ramsey
Department of Otorhinolaryngology - Head and Neck Surgery, Perelman School of Medicine at the University of Pennsylvania, 421 Curie Blvd, BRB 1220, Philadelphia, PA 19104, USA
1 shared publication Arun Padmanabhan
From the Department of Cell and Developmental Biology (K.D., A.P., J.A.E.), Penn Cardiovascular Institute, and the Institute for Regenerative Medicine, University of Pennsylvania, Philadelphia, Pa; the Laboratory for Structural NMR Imaging (A.C.W., D.H.), Department of Radiology, University of Pennsylvania Medical Center, Philadelphia, Pa; and the Department of Pediatrics (K.D.), Division of Cardiology, Children’s Hospital of Philadelphia, Philadelphia, Pa
1 shared publication- Bert W. O'Malley
Department of Otorhinolaryngology - Head and Neck Surgery, Perelman School of Medicine at the University of Pennsylvania, 421 Curie Blvd, BRB 1220, Philadelphia, PA 19104, USA
1 shared publication - Daqing Li
Department of Otorhinolaryngology, University of Pennsylvania, Philadelphia, PA 19104, USA
1 shared publication Dawn M. Elliott
Department of Biomedical Engineering, University of Delaware, Newark, DE, USA
1 shared publication- Dawn M. Elliott
Department of Biomedical Engineering University of Delaware Newark Delaware USA
1 shared publication
Latest Publications
- 1 February 2018
- Published by Elsevier in Nanomedicine: Nanotechnology, Biology and Medicine
- Vol. 14 (2) , 397-404
Challenges and opportunities in developing targeted molecular imaging to determine inner ear defects of sensorineural hearing loss
- 1 February 2018
- Published by Elsevier in Nanomedicine: Nanotechnology, Biology and Medicine
- Vol. 14 (2) , 397-404
Challenges and opportunities in developing targeted molecular imaging to determine inner ear defects of sensorineural hearing loss
- 11 January 2016
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 29 (4) , 711-722
Theory of MRI contrast in the annulus fibrosus of the intervertebral disc
Objective Here we develop a three-dimensional analytic model for MR image contrast of collagen lamellae in the annulus fibrosus of the intervertebral disc of the spine, based on the dependence of the MRI signal on collagen fiber orientation. Materials and methods High-resolution MRI scans were performed at 1.5 and 7 T on intact whole disc specimens from ovine, bovine, and human spines. An analytic model that approximates the three-dimensional curvature of the disc lamellae was developed to explain inter-lamellar contrast and intensity variations in the annulus. The model is based on the known anisotropic dipolar relaxation of water in tissues with ordered collagen. Results Simulated MRI data were generated that reproduced many features of the actual MRI data. The calculated inter-lamellar image contrast demonstrated a strong dependence on the collagen fiber angle and on the circumferential location within the annulus. Conclusion This analytic model may be useful for interpreting MR images of the disc and for predicting experimental conditions that will optimize MR image contrast in the annulus fibrosus.
- 11 January 2016
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 29 (4) , 711-722
Theory of MRI contrast in the annulus fibrosus of the intervertebral disc
Objective Here we develop a three-dimensional analytic model for MR image contrast of collagen lamellae in the annulus fibrosus of the intervertebral disc of the spine, based on the dependence of the MRI signal on collagen fiber orientation. Materials and methods High-resolution MRI scans were performed at 1.5 and 7 T on intact whole disc specimens from ovine, bovine, and human spines. An analytic model that approximates the three-dimensional curvature of the disc lamellae was developed to explain inter-lamellar contrast and intensity variations in the annulus. The model is based on the known anisotropic dipolar relaxation of water in tissues with ordered collagen. Results Simulated MRI data were generated that reproduced many features of the actual MRI data. The calculated inter-lamellar image contrast demonstrated a strong dependence on the collagen fiber angle and on the circumferential location within the annulus. Conclusion This analytic model may be useful for interpreting MR images of the disc and for predicting experimental conditions that will optimize MR image contrast in the annulus fibrosus.
- 17 September 2014
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 136 (11) , 111008-1110089
Internal Three-Dimensional Strains in Human Intervertebral Discs Under Axial Compression Quantified Noninvasively by Magnetic Resonance Imaging and Image Registration
Study objectives were to develop, validate, and apply a method to measure three-dimensional (3D) internal strains in intact human discs under axial compression. A custom-built loading device applied compression and permitted load-relaxation outside of the magnet while also maintaining compression and hydration during imaging. Strain was measured through registration of 300 μm isotropic resolution images. Excellent registration accuracy was achieved, with 94% and 65% overlap of disc volume and lamellae compared to manual segmentation, and an average Hausdorff, a measure of distance error, of 0.03 and 0.12 mm for disc volume and lamellae boundaries, respectively. Strain maps enabled qualitative visualization and quantitative regional annulus fibrosus (AF) strain analysis. Axial and circumferential strains were highest in the lateral AF and lowest in the anterior and posterior AF. Radial strains were lowest in the lateral AF, but highly variable. Overall, this study provided new methods that will be valuable in the design and evaluation surgical procedures and therapeutic interventions.
- 17 September 2014
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 136 (11) , 111008-1110089
Internal Three-Dimensional Strains in Human Intervertebral Discs Under Axial Compression Quantified Noninvasively by Magnetic Resonance Imaging and Image Registration
Study objectives were to develop, validate, and apply a method to measure three-dimensional (3D) internal strains in intact human discs under axial compression. A custom-built loading device applied compression and permitted load-relaxation outside of the magnet while also maintaining compression and hydration during imaging. Strain was measured through registration of 300 μm isotropic resolution images. Excellent registration accuracy was achieved, with 94% and 65% overlap of disc volume and lamellae compared to manual segmentation, and an average Hausdorff, a measure of distance error, of 0.03 and 0.12 mm for disc volume and lamellae boundaries, respectively. Strain maps enabled qualitative visualization and quantitative regional annulus fibrosus (AF) strain analysis. Axial and circumferential strains were highest in the lateral AF and lowest in the anterior and posterior AF. Radial strains were lowest in the lateral AF, but highly variable. Overall, this study provided new methods that will be valuable in the design and evaluation surgical procedures and therapeutic interventions.
- Open Access
- 23 February 2011
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 210 (1) , 113-122
Helmholtz-pair transmit coil with integrated receive array for high-resolution MRI of trabecular bone in the distal tibia at 7T
- 23 February 2011
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 210 (1) , 113-122
Open AccessHelmholtz-pair transmit coil with integrated receive array for high-resolution MRI of trabecular bone in the distal tibia at 7T
- Top Cited Papers
- 1 May 2010
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 3 (3) , 314-322
Rapid 3D Phenotyping of Cardiovascular Development in Mouse Embryos by Micro-CT With Iodine Staining
Background— Microcomputed tomography (micro-CT) has been used extensively in research to generate high-resolution 3D images of calcified tissues in small animals nondestructively. It has been especially useful for the characterization of skeletal mutations but limited in its utility for the analysis of soft tissue such as the cardiovascular system. Visualization of the cardiovascular system has been largely restricted to structures that can be filled with radiopaque intravascular contrast agents in adult animals. Recent ex vivo studies using osmium tetroxide, iodinated contrast agents, inorganic iodine, and phosphotungstic acid have demonstrated the ability to stain soft tissues differentially, allowing for high intertissue contrast in micro-CT images. In the present study, we demonstrate the application of this technology for visualization of cardiovascular structures in developing mouse embryos using Lugol solution (aqueous potassium iodide plus iodine). Methods and Results— We show the optimization of this method to obtain ex vivo micro-CT images of embryonic and neonatal mice with excellent soft-tissue contrast. We demonstrate the utility of this method to visualize key structures during cardiovascular development at various stages of embryogenesis. Our method benefits from the ease of sample preparation, low toxicity, and low cost. Furthermore, we show how multiple cardiac defects can be demonstrated by micro-CT in a single specimen with a known genetic lesion. Indeed, a previously undescribed cardiac venous abnormality is revealed in a PlexinD1 mutant mouse. Conclusions— Micro-CT of iodine-stained tissue is a valuable technique for the characterization of cardiovascular development and defects in mouse models of congenital heart disease.
- 1 May 2010
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 3 (3) , 314-322
Top Cited PapersRapid 3D Phenotyping of Cardiovascular Development in Mouse Embryos by Micro-CT With Iodine Staining
Background— Microcomputed tomography (micro-CT) has been used extensively in research to generate high-resolution 3D images of calcified tissues in small animals nondestructively. It has been especially useful for the characterization of skeletal mutations but limited in its utility for the analysis of soft tissue such as the cardiovascular system. Visualization of the cardiovascular system has been largely restricted to structures that can be filled with radiopaque intravascular contrast agents in adult animals. Recent ex vivo studies using osmium tetroxide, iodinated contrast agents, inorganic iodine, and phosphotungstic acid have demonstrated the ability to stain soft tissues differentially, allowing for high intertissue contrast in micro-CT images. In the present study, we demonstrate the application of this technology for visualization of cardiovascular structures in developing mouse embryos using Lugol solution (aqueous potassium iodide plus iodine). Methods and Results— We show the optimization of this method to obtain ex vivo micro-CT images of embryonic and neonatal mice with excellent soft-tissue contrast. We demonstrate the utility of this method to visualize key structures during cardiovascular development at various stages of embryogenesis. Our method benefits from the ease of sample preparation, low toxicity, and low cost. Furthermore, we show how multiple cardiac defects can be demonstrated by micro-CT in a single specimen with a known genetic lesion. Indeed, a previously undescribed cardiac venous abnormality is revealed in a PlexinD1 mutant mouse. Conclusions— Micro-CT of iodine-stained tissue is a valuable technique for the characterization of cardiovascular development and defects in mouse models of congenital heart disease.
- 31 May 2007
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 186 (1) , 17-25
Construction and calibration of a 50 T/m z-gradient coil for quantitative diffusion microimaging
- 31 May 2007
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 186 (1) , 17-25
Construction and calibration of a 50 T/m z-gradient coil for quantitative diffusion microimaging