Rolf Simon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rolf Simon has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Mateusz Czyzycki
Institute for Photon Science and Synchrotron Radiation, Karlsruhe Institute of Technology, 76344, Germany
2 shared publications - Tilo Baumbach
Institute for Photon Science and Synchrotron Radiation (IPS), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
2 shared publications - A. Wastl
Atominstitut, Technische Universitaet Wien, Stadionallee 2, 1020 Vienna, Austria
1 shared publication - Akira Mochihashi
Karlsruhe Institute of Technology
1 shared publication - Alexey Ershov
Institute for Photon Science and Synchrotron Radiation (IPS), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
1 shared publication - Andreas Roschger
Atominstitut, Technische Universitaet Wien, Stadionallee 2, 1020 Vienna, Austria
1 shared publication
Latest Publications
- Open Access
- 2 June 2025
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 32 (4) , 1036-1051
The IMAGE beamline at the KIT Light Source
The superconducting wiggler beamline IMAGE at the KIT Light Source is dedicated to full-field hard X-ray imaging applications in materials and life sciences, with a focus on high-throughput computed tomography, laminography experiments and systematic in situ and operando studies. With two experimental hutches, IMAGE provides space for its dedicated permanent experimental stations UFO-II and LAMINO-II as well as for flexible custom setups. IMAGE allows parallel beam imaging experiments in monochromatic, pink or white beam mode, with spatial resolutions ranging from ∼1 µm to ∼30 µm and a large horizontal and vertical field of view of up to 44 mm × 8 mm, respectively. Photon energies between 8 keV and 40 keV are provided by a double-crystal or double-multilayer monochromator optics with energy resolutions of 0.01% and 1.5–2.7%, respectively. The filtered white beam mode provides high flux densities of up to 7.5 × 1014 photons s−1 mm−2 at the sample position and energy spectra extending up to about 120 keV.
- 2 June 2025
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 32 (4) , 1036-1051
Open AccessThe IMAGE beamline at the KIT Light Source
The superconducting wiggler beamline IMAGE at the KIT Light Source is dedicated to full-field hard X-ray imaging applications in materials and life sciences, with a focus on high-throughput computed tomography, laminography experiments and systematic in situ and operando studies. With two experimental hutches, IMAGE provides space for its dedicated permanent experimental stations UFO-II and LAMINO-II as well as for flexible custom setups. IMAGE allows parallel beam imaging experiments in monochromatic, pink or white beam mode, with spatial resolutions ranging from ∼1 µm to ∼30 µm and a large horizontal and vertical field of view of up to 44 mm × 8 mm, respectively. Photon energies between 8 keV and 40 keV are provided by a double-crystal or double-multilayer monochromator optics with energy resolutions of 0.01% and 1.5–2.7%, respectively. The filtered white beam mode provides high flux densities of up to 7.5 × 1014 photons s−1 mm−2 at the sample position and energy spectra extending up to about 120 keV.
- Open Access
- 26 March 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (3) , 590-595
Scattered high-energy synchrotron radiation at the KARA visible-light diagnostic beamline
To characterize an electron beam, visible synchrotron light is often used and dedicated beamlines at synchrotron sources are becoming a more common feature as instruments and methods for the diagnostics are, along with the accelerators, further developed. At KARA (Karlsruhe Research Accelerator), such a beamline exists and is based on a typical infrared/visible-light configuration. From experience at such beamlines no significant radiation was expected (dose rates larger than 0.5 µSv h−1). This was found not to be the case and a higher dose was measured which fortunately could be shielded to an acceptable level with 0.3 mm of aluminium foil or 2.0 mm of Pyrex glass. The presence of this radiation led to further investigation by both experiment and calculation. A custom setup using a silicon drift detector for energy-dispersive spectroscopy (Ketek GmbH) and attenuation experiments showed the radiation to be predominantly copper K-shell fluorescence and is confirmed by calculation. The measurement of secondary radiation from scattering of synchrotron and other radiation, and its calculation, is important for radiation protection, and, although a lot of experience exists and methods for radiation protection are well established, changes in machine, beamlines and experiments mean a constant appraisal is needed.
- 26 March 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (3) , 590-595
Open AccessScattered high-energy synchrotron radiation at the KARA visible-light diagnostic beamline
To characterize an electron beam, visible synchrotron light is often used and dedicated beamlines at synchrotron sources are becoming a more common feature as instruments and methods for the diagnostics are, along with the accelerators, further developed. At KARA (Karlsruhe Research Accelerator), such a beamline exists and is based on a typical infrared/visible-light configuration. From experience at such beamlines no significant radiation was expected (dose rates larger than 0.5 µSv h−1). This was found not to be the case and a higher dose was measured which fortunately could be shielded to an acceptable level with 0.3 mm of aluminium foil or 2.0 mm of Pyrex glass. The presence of this radiation led to further investigation by both experiment and calculation. A custom setup using a silicon drift detector for energy-dispersive spectroscopy (Ketek GmbH) and attenuation experiments showed the radiation to be predominantly copper K-shell fluorescence and is confirmed by calculation. The measurement of secondary radiation from scattering of synchrotron and other radiation, and its calculation, is important for radiation protection, and, although a lot of experience exists and methods for radiation protection are well established, changes in machine, beamlines and experiments mean a constant appraisal is needed.
- Open Access
- 9 January 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (2) , 703
Altered Elemental Distribution in Male Rat Brain Tissue as a Predictor of Glioblastoma Multiforme Growth—Studies Using SR-XRF Microscopy
Glioblastoma multiforme (GBM) is a particularly malignant primary brain tumor. Despite enormous advances in the surgical treatment of cancer, radio- and chemotherapy, the average survival of patients suffering from this cancer does not usually exceed several months. For obvious ethical reasons, the search and testing of the new drugs and therapies of GBM cannot be carried out on humans, and for this purpose, animal models of the disease are most often used. However, to assess the efficacy and safety of the therapy basing on these models, a deep knowledge of the pathological changes associated with tumor development in the animal brain is necessary. Therefore, as part of our study, the synchrotron radiation-based X-ray fluorescence microscopy was applied for multi-elemental micro-imaging of the rat brain in which glioblastoma develops. Elemental changes occurring in animals after the implantation of two human glioma cell lines as well as the cells taken directly from a patient suffering from GBM were compared. Both the extent and intensity of elemental changes strongly correlated with the regions of glioma growth. The obtained results showed that the observation of elemental anomalies accompanying tumor development within an animal’s brain might facilitate our understanding of the pathogenesis and progress of GBM and also determine potential biomarkers of its extension. The tumors appearing in a rat’s brain were characterized by an increased accumulation of Fe and Se, whilst the tissue directly surrounding the tumor presented a higher accumulation of Cu. Furthermore, the results of the study allow us to consider Se as a potential elemental marker of GBM progression.
- 9 January 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (2) , 703
Open AccessAltered Elemental Distribution in Male Rat Brain Tissue as a Predictor of Glioblastoma Multiforme Growth—Studies Using SR-XRF Microscopy
Glioblastoma multiforme (GBM) is a particularly malignant primary brain tumor. Despite enormous advances in the surgical treatment of cancer, radio- and chemotherapy, the average survival of patients suffering from this cancer does not usually exceed several months. For obvious ethical reasons, the search and testing of the new drugs and therapies of GBM cannot be carried out on humans, and for this purpose, animal models of the disease are most often used. However, to assess the efficacy and safety of the therapy basing on these models, a deep knowledge of the pathological changes associated with tumor development in the animal brain is necessary. Therefore, as part of our study, the synchrotron radiation-based X-ray fluorescence microscopy was applied for multi-elemental micro-imaging of the rat brain in which glioblastoma develops. Elemental changes occurring in animals after the implantation of two human glioma cell lines as well as the cells taken directly from a patient suffering from GBM were compared. Both the extent and intensity of elemental changes strongly correlated with the regions of glioma growth. The obtained results showed that the observation of elemental anomalies accompanying tumor development within an animal’s brain might facilitate our understanding of the pathogenesis and progress of GBM and also determine potential biomarkers of its extension. The tumors appearing in a rat’s brain were characterized by an increased accumulation of Fe and Se, whilst the tissue directly surrounding the tumor presented a higher accumulation of Cu. Furthermore, the results of the study allow us to consider Se as a potential elemental marker of GBM progression.
- Open Access
Spatial distribution of the trace elements zinc, strontium and lead in human bone tissue