MVMiguel Valderrábano

Miguel Valderrábano

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Miguel Valderrábano has a total of 43 co-authors. Here are the top co-authors by number of shared publications:

  • Abhilash Krishna

    Department of Electrical and Computer Engineering, Rice University, Houston, Texas, USA.

    3 shared publications
  • Amish S. Dave

    Methodist DeBakey Heart and Vascular Center and Methodist Hospital Research Institute

    3 shared publications
  • John W. Clark

    Department of Electrical and Computer Engineering, Rice University, 6100 Main Street, Houston, 77005, USA

    3 shared publications
  • Philip T. Palade

    Department of Pharmacology and Toxicology, University of Arkansas for Medical Sciences, Little Rock, AR 72205, USA

    3 shared publications
  • Christine Sasaridis

    Methodist DeBakey Heart and Vascular Center and Methodist Hospital Research Institute, The Methodist Hospital, Houston, Texas, USA

    2 shared publications
  • Dipan J. Shah

    Division of Cardiac Imaging, Department of Cardiology , Methodist DeBakey Heart and Vascular Center , The Methodist Hospital , Houston, TX , USA

    2 shared publications

Latest Publications

  • MITRAL VALVE PARAVALVULAR LEAK CLOSURE USING A ROBOTIC CATHETER SYSTEM

    by Eric Bansal, Colin Barker, Neal Kleiman, Stephen Little, Miguel Valderrabano

  • DETECTION OF LEFT ATRIAL AND LEFT ATRIAL APPENDAGE THROMBUS BY CARDIAC MAGNETIC RESONANCE IN PATIENTS UNDERGOING PULMONARY VEIN ISOLATION

    by Danai Kitkungvan, Faisal Nabi, Mohamed Ghosn, Amish Dave, Miguel Valderrabano, William Zoghbi, Dipan Shah

  • 3D Cardiovascular Navigation System: Accuracy and Reduction in Radiation Exposure in Left Ventricular Lead Implant

    by Miguel Valderrabano, Steven Greenberg, Hedi Razavi, Rohan More, Kyungmoo Ryu, E. Kevin Heist

    Accurate 3D Navigation System for LV Lead Implant Introduction Cardiac resynchronization therapy implants entail significant radiation exposure for patients and physicians. A novel 3D electromagnetic cardiovascular navigation system (MediGuide (TM)) was designed to superimpose the real-time location of sensors embedded in delivery tools on prerecorded coronary sinus (CS) venograms while adjusting for patient movement and variations in heart rate under different C-arm angulations. We studied the accuracy and efficacy of MediGuide (TM) in reducing radiation exposure during LV lead implants. Methods and Results Fluoroscopy durations and radiation exposures were measured in 6 canines undergoing both conventional and MediGuide (TM)-guided LV lead implants. The in vivo accuracy of MediGuide (TM) was evaluated by obtaining CS venograms at 3 different C-arm angulations at 3 different heart rates and measuring the separation between the projected sensor icon of a MediGuide (TM) sensor-enabled guidewire and the encompassing branch on prerecorded venograms. Results Mediguide (TM)-guided implants resulted in significant reductions in fluoroscopy time (52 +/- 120 [median 6] vs 129 +/- 118 [median 90] sec, P < 0.001) and radiation exposure (13.8 +/- 32.4 [median 1.7] vs 49.2 +/- 45.3 [median 27.2] mu Gym(2), P = 0.03) compared to conventional implants. LV lead delivery time was not significantly different between the 2 implant techniques (P = 0.27). The mean separation between the projected guidewire sensor icon and its encompassing branch was 0.48 +/- 0.94 (median 0.00) mm. System accuracy was not affected by variations in heart rate or C-arm angulations. Conclusion The novel 3D cardiovascular navigation system enabled accurate and reliable tracking of sensor-enabled tools at varying heart rates and C-arm angulations with minimal need for fluoroscopy guidance, significantly reducing fluoroscopy time and radiation exposure.


  • Open Access

    Rate-dependent Ca2+ signalling underlying the force-frequency response in rat ventricular myocytes: a coupled electromechanical modeling study

    by Abhilash Krishna, Miguel Valderrábano, Philip T Palade, John W Clark

    Background: Rate-dependent effects on the C a 2+ sub-system in a rat ventricular myocyte are investigated. Here, we employ a deterministic mathematical model describing various C a 2+ signalling pathways under voltage clamp (VC) conditions, to better understand the important role of calmodulin (CaM) in modulating the key control variables C a 2+/calmodulin-dependent protein kinase-II (CaMKII), calcineurin (CaN), and cyclic adenosine monophosphate (cAMP) as they affect various intracellular targets. In particular, we study the frequency dependence of the peak force generated by the myofilaments, the force-frequency response (FFR). Methods: Our cell model incorporates frequency-dependent CaM-mediated spatially heterogenous interaction of CaMKII and CaN with their principal targets (dihydropyridine (DHPR) and ryanodine (RyR) receptors and the SERCA pump). It also accounts for the rate-dependent effects of phospholamban (PLB) on the SERCA pump; the rate-dependent role of cAMP in up-regulation of the L-type C a 2+ channel (I C a,L ); and the enhancement in SERCA pump activity via phosphorylation of PLB. Results: Our model reproduces positive peak FFR observed in rat ventricular myocytes during voltage-clamp studies both in the presence/absence of cAMP mediated β-adrenergic stimulation. This study provides quantitative insight into the rate-dependence of C a 2+-induced C a 2+-release (CICR) by investigating the frequency-dependence of the trigger current (I C a,L ) and RyR-release. It also highlights the relative role of the sodium-calcium exchanger (NCX) and the SERCA pump at higher frequencies, as well as the rate-dependence of sarcoplasmic reticulum (SR) C a 2+ content. A rigorous C a 2+ balance imposed on our investigation of these C a 2+ signalling pathways clarifies their individual roles. Here, we present a coupled electromechanical study emphasizing the rate-dependence of isometric force developed and also investigate the temperature-dependence of FFR. Conclusions: Our model provides mechanistic biophysically based explanations for the rate-dependence of CICR, generating useful and testable hypotheses. Although rat ventricular myocytes exhibit a positive peak FFR in the presence/absence of beta-adrenergic stimulation, they show a characteristic increase in the positive slope in FFR due to the presence of Norepinephrine or Isoproterenol. Our study identifies cAMP-mediated stimulation, and rate-dependent CaMKII-mediated up-regulation of I C a,L as the key mechanisms underlying the aforementioned positive FFR.


  • Open Access

    Magnetic resonance imaging of a percutaneously ligated left atrial appendage

    by Itamar Birnbaum, Dipan J. Shah, Miguel Valderrábano

    A 56-year-old man with a history of persistent and refractory atrial fibrillation (AF) presented with a cerebrovascular accident. Cardioversion was attempted previously, however his AF recurred. A cardiac magnetic resonance imaging (MRI) was done (panels A, B) and he underwent extensive AF ablation which improved exercise tolerance. Owing to inconsistent anticoagulation with warfarin and intolerance to dabigatran he was offered percutaneous exclusion of the left atrial appendage (LAA) via an epicardial approach with the Lariat®. A left atrial angiogram and an intraoperative transesophageal echocardiogram were performed to confirm occlusion of the appendage (panels C, D). Three months after Lariat® closure of the LAA, a repeat AF ablation was planned and the patient underwent a second MRI which allowed assessment of LAA closure (panels E, F). The LAA is widely recognized as the likely source of thrombi in patients with non-valvular AF. Exclusion of the LAA with the Lariat® demonstrates complete occlusion of the appendage by magnetic resonance as well as angiographic imaging and may be useful in patients who are poor candidates for chronic anticoagulation.


  • Open Access

    Multiphysics model of a rat ventricular myocyte: A voltage-clamp study

    by Abhilash Krishna, Miguel Valderrábano, Philip T Palade, John W

    Background: The objective of this study is to develop a comprehensive model of the electromechanical behavior of the rat ventricular myocyte to investigate the various factors influencing its contractile response. Methods: Here, we couple a model of C a 2 + dynamics described in our previous work, with a well-known model of contractile mechanics developed by Rice, Wang, Bers and de Tombe to develop a composite multiphysics model of excitation-contraction coupling. This comprehensive cell model is studied under voltage clamp (VC) conditions, since it allows to focus our study on the elaborate C a 2 + signaling system that controls the contractile mechanism. Results: We examine the role of various factors influencing cellular contractile response. In particular, direct factors such as the amount of activator C a 2 + available to trigger contraction and the type of mechanical load applied (resulting in isosarcometric, isometric or unloaded contraction) are investigated. We also study the impact of temperature (22 to 38°C) on myofilament contractile response. The critical role of myofilament C a 2 + sensitivity in modulating developed force is likewise studied, as is the indirect coupling of intracellular contractile mechanism with the plasma membrane via the N a + /C a 2 + exchanger (NCX). Finally, we demonstrate a key linear relationship between the rate of contraction and relaxation, which is shown here to be intrinsically coupled over the full range of physiological perturbations. Conclusions: Extensive testing of the composite model elucidates the importance of various direct and indirect modulatory influences on cellular twitch response with wide agreement with measured data on all accounts. Thus, the model provides mechanistic insights into whole-cell responses to a wide variety of testing approaches used in studies of cardiac myofilament contractility that have appeared in the literature over the past several decades.


  • Coronary venous ethanol infusion for the treatment of refractory ventricular tachycardia

    by Alex Baher, Dipan J. Shah, Miguel Valderrabano


  • Ethanol infusion in the vein of Marshall facilitates mitral isthmus ablation

    by José L. Báez-Escudero, Percy Francisco Morales, Amish S. Dave, Christine M. Sasaridis, Young-Hoon Kim, Kaoru Okishige, Miguel Valderrábano


  • Role of the Vein of Marshall in Atrial Fibrillation Recurrences After Catheter Ablation: Therapeutic Effect of Ethanol Infusion

    by Amish S. Dave, José L. Báez‐Escudero, Christine Sasaridis, Thomas E. Hong, Tapan Rami, Miguel Valderrábano

    Vein of Marshall Ethanol in Recurrent AF. Introduction: Atrial fibrillation (AF) or flutter can recur after pulmonary vein (PV) antral isolation (PVAI). The vein of Marshall (VOM) has been linked to the genesis of AF. We hypothesized that the VOM may play a role in AF recurrences and that VOM ethanol infusion may have therapeutic value in this setting. Methods and Results: Sixty‐one patients with recurrent AF or flutter after PVAI were studied. The VOM was successfully cannulated in 54; VOM and PV electrograms were recorded, and differential PV‐VOM pacing was performed. VOM signals were present in all patients; however, VOM triggers of AF could not be demonstrated. VOM tachycardia was present in 1 patient. Left inferior (LIPV) and left superior (LSPV) reconnection was present in 32 and 30 patients, respectively. Differential pacing in VOM and LIPV showed VOM‐mediated LIPV reconnection in 5/32 patients. In others, VOM and PV connected indirectly via left atrial tissues. Up to four 1 cc infusions of 98% ethanol were delivered in the VOM. Regardless of the reconnection pattern, ethanol infusion eliminated LIPV and LSPV reconnection in 23/32 and 13/30 patients, respectively. Ethanol terminated VOM and LIPV tachycardias in 2 patients. There were no acute procedural complications. Conclusions: VOM signals are consistently present in recurrent AF. VOM may rarely play a role in PV reconnection. However, VOM ethanol infusion can be useful in patients with recurrent AF after PVAI, assisting in achieving redisconnection of reconnected left PVs. (J Cardiovasc Electrophysiol, Vol. 23, pp. 583–591, June 2012)