Yan Mei Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yan Mei Wang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Michael C. DeSantis
Janelia Research Campus, Howard Hughes Medical Institute
4 shared publications Shannon Kian Zareh
Department of Physics, Washington University in St. Louis, Saint Louis, Missouri, USA
3 shared publicationsShawn H. DeCenzo
Department of Physics Washington University 63130 St. Louis MO USA
3 shared publicationsJe-Luen Li
‡D. E. Shaw Research, New York, New York
2 shared publicationsJonathan M. Kessler
†Department of Physics, Washington University in St. Louis, Saint Louis, Missouri
1 shared publicationMichael C. DeSantis
Department of Physics Washington University 63130 St. Louis MO USA
1 shared publication
Latest Publications
- 1 April 2012
- Published by Elsevier in Biophysical Journal
- Vol. 102 (7) , 1685-1691
Single-Image Diffusion Coefficient Measurements of Proteins in Free Solution
- 1 April 2012
- Published by Elsevier in Biophysical Journal
- Vol. 102 (7) , 1685-1691
Single-Image Diffusion Coefficient Measurements of Proteins in Free Solution
- Open Access
- 25 January 2012
- Published by Optica Publishing Group in Optics Express
- Vol. 20 (3) , 3057-3065
Single-image axial localization precision analysis for individual fluorophores
Bio-mechanism investigations demand single particle tracking with high spatial and temporal resolutions which require single fluorophore 3D localization measurements with matching precision and speed. Although the precision for lateral-localization measurements is well described by an analytical expression, for the axial direction, it is often obtained by repeating location measurements or by estimating a lower bound. Here, we report a precision expression for an axial-localization method that analyzes the standard deviations of single fluorophores’ intensity profiles. Like the lateral-localization precision, this expression includes all relevant experimental effects measurable from a Gaussian intensity profile of the fluorophore. This expression completes the precision analysis for single-image 3D localization of individual fluorophores and lifts the temporal resolution to the typical exposure timescales of milliseconds.
- 25 January 2012
- Published by Optica Publishing Group in Optics Express
- Vol. 20 (3) , 3057-3065
Open AccessSingle-image axial localization precision analysis for individual fluorophores
Bio-mechanism investigations demand single particle tracking with high spatial and temporal resolutions which require single fluorophore 3D localization measurements with matching precision and speed. Although the precision for lateral-localization measurements is well described by an analytical expression, for the axial direction, it is often obtained by repeating location measurements or by estimating a lower bound. Here, we report a precision expression for an axial-localization method that analyzes the standard deviations of single fluorophores’ intensity profiles. Like the lateral-localization precision, this expression includes all relevant experimental effects measurable from a Gaussian intensity profile of the fluorophore. This expression completes the precision analysis for single-image 3D localization of individual fluorophores and lifts the temporal resolution to the typical exposure timescales of milliseconds.
- 17 November 2010
- Published by Wiley in Microscopy Research and Technique
- Vol. 74 (7) , 682-687
Single‐molecule imaging of protein adsorption mechanisms to surfaces
Protein‐surface interactions cause the desirable effect of controlled protein adsorption onto biodevices as well as the undesirable effect of protein fouling. The key to controlling protein‐surface adsorptions is to identify and quantify the main adsorption mechanisms: adsorptions that occur (1) while depositing a protein solution onto dry surfaces and (2) after the deposition onto wet surfaces. Bulk measurements cannot reveal the dynamic protein adsorption pathways and thus cannot differentiate between the two adsorption mechanisms. We imaged the interactions of single streptavidin molecules with hydrophobic fused‐silica surfaces in real‐time. We observed both adsorbed proteins on surfaces and diffusing proteins near surfaces and analyzed their adsorption kinetics. Our analysis shows that the protein solution deposition process is the primary mechanism of streptavidin adsorption onto surfaces at the subnanomolar to nanomolar protein concentrations. Furthermore, we found that hydrophilic fused‐silica surfaces can prevent the adsorption of streptavidin molecules. Microsc. Res. Tech., 2011.
- 17 November 2010
- Published by Wiley in Microscopy Research and Technique
- Vol. 74 (7) , 682-687
Single‐molecule imaging of protein adsorption mechanisms to surfaces
Protein‐surface interactions cause the desirable effect of controlled protein adsorption onto biodevices as well as the undesirable effect of protein fouling. The key to controlling protein‐surface adsorptions is to identify and quantify the main adsorption mechanisms: adsorptions that occur (1) while depositing a protein solution onto dry surfaces and (2) after the deposition onto wet surfaces. Bulk measurements cannot reveal the dynamic protein adsorption pathways and thus cannot differentiate between the two adsorption mechanisms. We imaged the interactions of single streptavidin molecules with hydrophobic fused‐silica surfaces in real‐time. We observed both adsorbed proteins on surfaces and diffusing proteins near surfaces and analyzed their adsorption kinetics. Our analysis shows that the protein solution deposition process is the primary mechanism of streptavidin adsorption onto surfaces at the subnanomolar to nanomolar protein concentrations. Furthermore, we found that hydrophilic fused‐silica surfaces can prevent the adsorption of streptavidin molecules. Microsc. Res. Tech., 2011.
- Open Access
Single-image measurements of monochromatic subdiffraction dimolecular separations
Measuring subdiffraction separations between single fluorescent particles is important for biological, nano-, and medical-technology studies. Major challenges include (i) measuring changing molecular separations with high temporal resolution while (ii) using identical fluorescent labels. Here we report a method that measures subdiffraction separations between two identical fluorophores by using a single image of milliseconds exposure time and a standard single-molecule fluorescent imaging setup. The fluorophores do not need to be bleached and the separations can be measured down to 40 nm with nanometer precision. The method is called single-molecule image deconvolution -- SMID, and in this article it measures the standard deviation (SD) of Gaussian-approximated combined fluorescent intensity profiles of the two subdiffraction-separated fluorophores. This study enables measurements of (i) subdiffraction dimolecular separations using a single image, lifting the temporal resolution of seconds to milliseconds, while (ii) using identical fluorophores. The single-image nature of this dimer separation study makes it a single-image molecular analysis (SIMA) study.
Open AccessSingle-image measurements of monochromatic subdiffraction dimolecular separations
Measuring subdiffraction separations between single fluorescent particles is important for biological, nano-, and medical-technology studies. Major challenges include (i) measuring changing molecular separations with high temporal resolution while (ii) using identical fluorescent labels. Here we report a method that measures subdiffraction separations between two identical fluorophores by using a single image of milliseconds exposure time and a standard single-molecule fluorescent imaging setup. The fluorophores do not need to be bleached and the separations can be measured down to 40 nm with nanometer precision. The method is called single-molecule image deconvolution -- SMID, and in this article it measures the standard deviation (SD) of Gaussian-approximated combined fluorescent intensity profiles of the two subdiffraction-separated fluorophores. This study enables measurements of (i) subdiffraction dimolecular separations using a single image, lifting the temporal resolution of seconds to milliseconds, while (ii) using identical fluorophores. The single-image nature of this dimer separation study makes it a single-image molecular analysis (SIMA) study.
- Open Access
- 23 July 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (16) , 16628-39
Single-image separation measurements of two unresolved fluorophores.
Measuring subdiffraction separations between single fluorescent particles is important for biological, nano-, and medical-technology studies. Major challenges include (i) measuring changing molecular separations with high temporal resolution while (ii) using identical fluorescent labels. Here we report a method that measures subdiffraction separations between two identical fluorophores by using a single image of milliseconds exposure time and a standard single-molecule fluorescent imaging setup. The fluorophores do not need to be bleached and the separations can be measured down to 40 nm with nanometer precision. The method is called single-molecule image deconvolution--SMID, and in this article it measures the standard deviation (SD) of Gaussian-approximated combined fluorescent intensity profiles of the two subdiffraction-separated fluorophores. This study enables measurements of (i) subdiffraction dimolecular separations using a single image, lifting the temporal resolution of seconds to milliseconds, while (ii) using identical fluorophores. The single-image nature of this dimer separation study makes it a single-image molecular analysis (SIMA) study.
- 23 July 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (16) , 16628-39
Open AccessSingle-image separation measurements of two unresolved fluorophores.
Measuring subdiffraction separations between single fluorescent particles is important for biological, nano-, and medical-technology studies. Major challenges include (i) measuring changing molecular separations with high temporal resolution while (ii) using identical fluorescent labels. Here we report a method that measures subdiffraction separations between two identical fluorophores by using a single image of milliseconds exposure time and a standard single-molecule fluorescent imaging setup. The fluorophores do not need to be bleached and the separations can be measured down to 40 nm with nanometer precision. The method is called single-molecule image deconvolution--SMID, and in this article it measures the standard deviation (SD) of Gaussian-approximated combined fluorescent intensity profiles of the two subdiffraction-separated fluorophores. This study enables measurements of (i) subdiffraction dimolecular separations using a single image, lifting the temporal resolution of seconds to milliseconds, while (ii) using identical fluorophores. The single-image nature of this dimer separation study makes it a single-image molecular analysis (SIMA) study.
- Open Access
- 15 March 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (7) , 6563-6576
Precision analysis for standard deviation measurements of immobile single fluorescent molecule images
Standard deviation measurements of intensity profiles of stationary single fluorescent molecules are useful for studying axial localization, molecular orientation, and a fluorescence imaging system’s spatial resolution. Here we report on the analysis of the precision of standard deviation measurements of intensity profiles of single fluorescent molecules imaged using an EMCCD camera. We have developed an analytical expression for the standard deviation measurement error of a single image which is a function of the total number of detected photons, the background photon noise, and the camera pixel size. The theoretical results agree well with the experimental, simulation, and numerical integration results. Using this expression, we show that single-molecule standard deviation measurements offer nanometer precision for a large range of experimental parameters.
- 15 March 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (7) , 6563-6576
Open AccessPrecision analysis for standard deviation measurements of immobile single fluorescent molecule images
Standard deviation measurements of intensity profiles of stationary single fluorescent molecules are useful for studying axial localization, molecular orientation, and a fluorescence imaging system’s spatial resolution. Here we report on the analysis of the precision of standard deviation measurements of intensity profiles of single fluorescent molecules imaged using an EMCCD camera. We have developed an analytical expression for the standard deviation measurement error of a single image which is a function of the total number of detected photons, the background photon noise, and the camera pixel size. The theoretical results agree well with the experimental, simulation, and numerical integration results. Using this expression, we show that single-molecule standard deviation measurements offer nanometer precision for a large range of experimental parameters.