Marom Bikson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marom Bikson has a total of 411 co-authors. Here are the top co-authors by number of shared publications:
Abhishek Datta
Soterix Medical, New York, NY, USA
15 shared publications- Abhishek Datta
Research and Development, Soterix Medical Inc., Woodbridge, NJ, USA
14 shared publications - Niranjan Khadka
Research and Development, Soterix Medical Inc., Woodbridge, NJ, USA
14 shared publications Niranjan Khadka
Division of Neuropsychiatry and Neuromodulation, Massachusetts General Hospital, Harvard Medical School
11 shared publicationsAsif Rahman
Department of Biomedical Engineering, The City College of the City University of New York, NY, USA
10 shared publications- Leigh Charvet
Department of Neurology, New York University Grossman School of Medicine, New York, NY, USA
9 shared publications
Latest Publications
- Open Access
Impedance-Derived Heart Rate and Heart Rate Variability from tDCS Output Voltage: Sensorless Physiological Monitoring During Electrical Neuromodulation
Background: Transcranial direct current stimulation (tDCS) devices adjust output voltage to maintain the target current despite varying impedance. Pulsatile blood flow produces beat-synchronous changes in tissue impedance. Objective: To determine whether impedance-derived heart rate (IHR), heart rate variability (IHRV), and respiration (IDR) can be estimated from tDCS output voltage without additional physiological sensors. Methods: A custom analog front-end acquires the tDCS output voltage across its full dynamic DC range and superimposed AC fluctuations with high precision. Beats detected from the AC-coupled signal yielded normal-to-normal intervals for HR, HRV, and interval-derived respiration. Accuracy was quantified as mean absolute error (MAE) in 10 healthy laboratory participants against ECG and respiration-monitor references, and against chest-strap RR intervals in 19 at-home sessions from 10 participants with mild-to-moderate depression. Results: Laboratory MAEs versus ECG were 0.57 bpm for HR, 9.40 ms for SDNN, and 18.90 ms for RMSSD (r = 0.995, 0.859, and 0.778; N = 10); respiratory-rate MAE was 1.36 breaths/min (r = 0.852; N = 6). Across 1-5 mA of tDCS, the cardiac voltage ΔV cardiac (t) amplitude scaled linearly with current (slope, 0.073 mV/mA; p < 0.001). The pulsatile impedance ΔZ cardiac (t) = (ΔV cardiac (t)/I applied ) amplitude averaged 0.080 ± 0.029 Ω (mean ± SD) across 50 participant-current observations, with no significant dependence on intensity (slope, −0.002 Ω/mA; p = 0.086). At-home MAEs were 1.43 bpm for HR, 8.86 ms for SDNN, and 24.92 ms for RMSSD (r = 0.995, 0.767, and 0.680; 19 sessions). Conclusions: tDCS output voltage contains a recoverable cardiac-synchronous signal arising from pulsatile impedance, enabling HR, HRV, and respiratory monitoring without additional physiological sensors.
Open AccessImpedance-Derived Heart Rate and Heart Rate Variability from tDCS Output Voltage: Sensorless Physiological Monitoring During Electrical Neuromodulation
Background: Transcranial direct current stimulation (tDCS) devices adjust output voltage to maintain the target current despite varying impedance. Pulsatile blood flow produces beat-synchronous changes in tissue impedance. Objective: To determine whether impedance-derived heart rate (IHR), heart rate variability (IHRV), and respiration (IDR) can be estimated from tDCS output voltage without additional physiological sensors. Methods: A custom analog front-end acquires the tDCS output voltage across its full dynamic DC range and superimposed AC fluctuations with high precision. Beats detected from the AC-coupled signal yielded normal-to-normal intervals for HR, HRV, and interval-derived respiration. Accuracy was quantified as mean absolute error (MAE) in 10 healthy laboratory participants against ECG and respiration-monitor references, and against chest-strap RR intervals in 19 at-home sessions from 10 participants with mild-to-moderate depression. Results: Laboratory MAEs versus ECG were 0.57 bpm for HR, 9.40 ms for SDNN, and 18.90 ms for RMSSD (r = 0.995, 0.859, and 0.778; N = 10); respiratory-rate MAE was 1.36 breaths/min (r = 0.852; N = 6). Across 1-5 mA of tDCS, the cardiac voltage ΔV cardiac (t) amplitude scaled linearly with current (slope, 0.073 mV/mA; p < 0.001). The pulsatile impedance ΔZ cardiac (t) = (ΔV cardiac (t)/I applied ) amplitude averaged 0.080 ± 0.029 Ω (mean ± SD) across 50 participant-current observations, with no significant dependence on intensity (slope, −0.002 Ω/mA; p = 0.086). At-home MAEs were 1.43 bpm for HR, 8.86 ms for SDNN, and 24.92 ms for RMSSD (r = 0.995, 0.767, and 0.680; 19 sessions). Conclusions: tDCS output voltage contains a recoverable cardiac-synchronous signal arising from pulsatile impedance, enabling HR, HRV, and respiratory monitoring without additional physiological sensors.
- Open Access
- 29 May 2026
- Published by Elsevier in Brain Stimulation
- Vol. 19 (4) , 103132
Transcranial direct current stimulation with motor-learning based gait therapy post-stroke: A randomized controlled trial
- 29 May 2026
- Published by Elsevier in Brain Stimulation
- Vol. 19 (4) , 103132
Open AccessTranscranial direct current stimulation with motor-learning based gait therapy post-stroke: A randomized controlled trial
- Open Access
- 30 March 2026
- Published by Elsevier in Clinical Neurophysiology Practice
- Vol. 11, 218-251
Home use of low-intensity transcranial electrical stimulation in clinical practice: an IFCN handbook chapter
- 30 March 2026
- Published by Elsevier in Clinical Neurophysiology Practice
- Vol. 11, 218-251
Open AccessHome use of low-intensity transcranial electrical stimulation in clinical practice: an IFCN handbook chapter
- Open Access
- 30 December 2025
- Published by Elsevier in Brain Stimulation
- Vol. 19 (1) , 103021
US FDA approves home-delivered tDCS for treating depression
- 30 December 2025
- Published by Elsevier in Brain Stimulation
- Vol. 19 (1) , 103021
Open AccessUS FDA approves home-delivered tDCS for treating depression
- 9 September 2025
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 223,p. e68815
Personalized 3D-printed Headgear for Multi-electrode Transcranial Electrical Stimulation
We present an overview of a novel, patented, approach for creating personalized 3D-printed headgear that enables multi-electrode transcranial electrical stimulation, even in the home. A structural magnetic resonance imaging (MRI) scan is used to optimize a montage that targets key brain areas/networks and is then uploaded to a secure server to design customized headgear that is ultimately 3D-printed. The headgear allows rapid multi-electrode placement (<1 min per electrode) with comparable accuracy as manual 10-10 measurements. We performed over 1,400 sessions across 63 older adults with neurological injury or disease. We describe an efficient training program for study partners (e.g., spouses) that enabled a 100% success rate and over 900 remotely administered sessions. Study partners and participants reported high levels of confidence and satisfaction with the experience. Because the electrode locations are based on personalized computational modeling, the headgear is ideal for techniques requiring precision (e.g., temporal interference stimulation, transcranial focused ultrasound, transcranial magnetic stimulation).
- 9 September 2025
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 223,p. e68815
Personalized 3D-printed Headgear for Multi-electrode Transcranial Electrical Stimulation
We present an overview of a novel, patented, approach for creating personalized 3D-printed headgear that enables multi-electrode transcranial electrical stimulation, even in the home. A structural magnetic resonance imaging (MRI) scan is used to optimize a montage that targets key brain areas/networks and is then uploaded to a secure server to design customized headgear that is ultimately 3D-printed. The headgear allows rapid multi-electrode placement (<1 min per electrode) with comparable accuracy as manual 10-10 measurements. We performed over 1,400 sessions across 63 older adults with neurological injury or disease. We describe an efficient training program for study partners (e.g., spouses) that enabled a 100% success rate and over 900 remotely administered sessions. Study partners and participants reported high levels of confidence and satisfaction with the experience. Because the electrode locations are based on personalized computational modeling, the headgear is ideal for techniques requiring precision (e.g., temporal interference stimulation, transcranial focused ultrasound, transcranial magnetic stimulation).
- 9 September 2025
- Published by MyJove Corporation
- No. 223,p. e68815
JoVE Video Dataset
We present an overview of a novel, patented, approach for creating personalized 3D-printed headgear that enables multi-electrode transcranial electrical stimulation, even in the home. A structural magnetic resonance imaging (MRI) scan is used to optimize a montage that targets key brain areas/networks and is then uploaded to a secure server to design customized headgear that is ultimately 3D-printed. The headgear allows rapid multi-electrode placement (<1 min per electrode) with comparable accuracy as manual 10-10 measurements. We performed over 1,400 sessions across 63 older adults with neurological injury or disease. We describe an efficient training program for study partners (e.g., spouses) that enabled a 100% success rate and over 900 remotely administered sessions. Study partners and participants reported high levels of confidence and satisfaction with the experience. Because the electrode locations are based on personalized computational modeling, the headgear is ideal for techniques requiring precision (e.g., temporal interference stimulation, transcranial focused ultrasound, transcranial magnetic stimulation).
- 9 September 2025
- Published by MyJove Corporation
- No. 223,p. e68815
JoVE Video Dataset
We present an overview of a novel, patented, approach for creating personalized 3D-printed headgear that enables multi-electrode transcranial electrical stimulation, even in the home. A structural magnetic resonance imaging (MRI) scan is used to optimize a montage that targets key brain areas/networks and is then uploaded to a secure server to design customized headgear that is ultimately 3D-printed. The headgear allows rapid multi-electrode placement (<1 min per electrode) with comparable accuracy as manual 10-10 measurements. We performed over 1,400 sessions across 63 older adults with neurological injury or disease. We describe an efficient training program for study partners (e.g., spouses) that enabled a 100% success rate and over 900 remotely administered sessions. Study partners and participants reported high levels of confidence and satisfaction with the experience. Because the electrode locations are based on personalized computational modeling, the headgear is ideal for techniques requiring precision (e.g., temporal interference stimulation, transcranial focused ultrasound, transcranial magnetic stimulation).
- Open Access
- 19 June 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (6) , 672
Resting-State Activity Changes Induced by tDCS in MS Patients and Healthy Controls: A Simultaneous tDCS rs-fMRI Study
Transcranial direct current stimulation (tDCS) is a safe, well-tolerated method of non-invasively eliciting cortical neuromodulation. It has gained recent interest, especially for its positive clinical outcomes in neurodegenerative diseases such as multiple sclerosis (MS). However, its simultaneous (during tDCS) and cumulative effects (following repeated tDCS sessions) on the regional brain activity during rest need further investigation, especially in MS. This study aims to elucidate tDCS’ underpinnings, alongside its therapeutic impact in MS patients, using concurrent tDCS-MRI methods. In total, 20 MS patients (age = 48 ± 12 years; 8 males) and 28 healthy controls (HCs; age = 36 ± 15 years; 12 males) were recruited. They participated in a tDCS-MRI session, during which resting-state functional MRI (rs-fMRI) was used to measure the levels of the fractional amplitude of low-frequency fluctuations (fALFFs), which is an index of regional neuronal activity, before and during left anodal dorsolateral prefrontal cortex (DLPFC) tDCS (2.0 mA for 15 min). MS patients were then asked to return for an identical tDCS-MRI visit (follow-up) after 20 identical at-home tDCS sessions. Simultaneous tDCS-induced changes in fALFF are seen across cortical and subcortical areas in both HC and MS patients, with some regions showing increased and others decreased brain activity. In HCs, fALFF increased in the right pre- and post-central gyrus whilst it decreased in subcortical regions. Conversely, MS patients initially displayed increases in more posterior cortical regions but decreases in the superior and temporal cortical regions. At follow-up, MS patients showed reversed patterns, emphasizing significant cumulative effects of tDCS treatment upon brain excitation. Such long-lasting changes are further supported by greater pre-tDCS fALFFs measured at follow-up compared to baseline, especially around the cuneus. The results were significant after correcting for multiple comparisons (p-FDR < 0.05). Our study shows that tDCS has both simultaneous and cumulative effects on neuronal activity measured with rs-fMRI, especially involving major brain areas distant from the site of stimulation, and it is responsible for fatigue and cognitive and motor skills.
- 19 June 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (6) , 672
Open AccessResting-State Activity Changes Induced by tDCS in MS Patients and Healthy Controls: A Simultaneous tDCS rs-fMRI Study
Transcranial direct current stimulation (tDCS) is a safe, well-tolerated method of non-invasively eliciting cortical neuromodulation. It has gained recent interest, especially for its positive clinical outcomes in neurodegenerative diseases such as multiple sclerosis (MS). However, its simultaneous (during tDCS) and cumulative effects (following repeated tDCS sessions) on the regional brain activity during rest need further investigation, especially in MS. This study aims to elucidate tDCS’ underpinnings, alongside its therapeutic impact in MS patients, using concurrent tDCS-MRI methods. In total, 20 MS patients (age = 48 ± 12 years; 8 males) and 28 healthy controls (HCs; age = 36 ± 15 years; 12 males) were recruited. They participated in a tDCS-MRI session, during which resting-state functional MRI (rs-fMRI) was used to measure the levels of the fractional amplitude of low-frequency fluctuations (fALFFs), which is an index of regional neuronal activity, before and during left anodal dorsolateral prefrontal cortex (DLPFC) tDCS (2.0 mA for 15 min). MS patients were then asked to return for an identical tDCS-MRI visit (follow-up) after 20 identical at-home tDCS sessions. Simultaneous tDCS-induced changes in fALFF are seen across cortical and subcortical areas in both HC and MS patients, with some regions showing increased and others decreased brain activity. In HCs, fALFF increased in the right pre- and post-central gyrus whilst it decreased in subcortical regions. Conversely, MS patients initially displayed increases in more posterior cortical regions but decreases in the superior and temporal cortical regions. At follow-up, MS patients showed reversed patterns, emphasizing significant cumulative effects of tDCS treatment upon brain excitation. Such long-lasting changes are further supported by greater pre-tDCS fALFFs measured at follow-up compared to baseline, especially around the cuneus. The results were significant after correcting for multiple comparisons (p-FDR < 0.05). Our study shows that tDCS has both simultaneous and cumulative effects on neuronal activity measured with rs-fMRI, especially involving major brain areas distant from the site of stimulation, and it is responsible for fatigue and cognitive and motor skills.
- Open Access
High-Capacity transcranial Direct Current Stimulation (HC-tDCS)
Background: Enhancing tDCS technology can support the delivery of higher current intensities, enabling broader dose-response studies in human trials. Methods: High-Capacity tDCS (HC-tDCS) integrates novel electrodes and adaptive current/voltage controlled electronics. Multi-layer HC electrodes include polarity-specific redox layers and designed hydrogel interfaces, shaped for a bifrontotemporal montage. The stimulator design includes adaptive ramps with hybrid voltage-current control and low (7.5 V) compliance voltage. Scanning electron microscopy (SEM) and electrical impedance spectroscopy (EIS) were used to characterize electrode properties. Tolerability of HD-tDCS was tested for target currents 1-6 mA (in 1 mA increments) for 30 min on 5 healthy subjects, and compared with conventional tDCS using 2 mA F3-F4 sponge-electrodes. MRI-derived computational models predicted cortical electric fields. Tolerability was assessed according to the 100 mm visual analogue scale for pain (VASP-100), skin erythema assessment, thermal imaging, and adverse event questionnaires. Results: The electrode design including high-roughness polarity-specific capacity, electrochemically supports high-charge direct current stimulation. In all subjects, HC-tDCS was well tolerated at all tested doses (1-6 mA) with minor transient adverse events and average VASP-100 less than 15. VASP-100 during sponge-electrode tDCS at 2 mA was comparable to 5 and 6 mA HC-tDCS. HC-tDCS operates at significantly lower voltage than sponge-tDCS, impacting tolerability and efficiency. Modeling predicts peak frontal electric fields of 0.65-1.08 V/m for 2 mA HC-tDCS and 1.95-3.25 V/m for 6 mA HC-tDCS, compared to 0.49-0.95 V/m for 2 mA sponge-tDCS. Conclusions: HC-tDCS allows increased cortical stimulation; at 6 mA achieving double the 1 V/m electric field threshold in all subjects. Enabled by pre-stimulation procedures, specialized electrodes, and adaptive low-voltage stimulators, HC-tDCS is well tolerated at intensities up to at least 6 mA.
Open AccessHigh-Capacity transcranial Direct Current Stimulation (HC-tDCS)
Background: Enhancing tDCS technology can support the delivery of higher current intensities, enabling broader dose-response studies in human trials. Methods: High-Capacity tDCS (HC-tDCS) integrates novel electrodes and adaptive current/voltage controlled electronics. Multi-layer HC electrodes include polarity-specific redox layers and designed hydrogel interfaces, shaped for a bifrontotemporal montage. The stimulator design includes adaptive ramps with hybrid voltage-current control and low (7.5 V) compliance voltage. Scanning electron microscopy (SEM) and electrical impedance spectroscopy (EIS) were used to characterize electrode properties. Tolerability of HD-tDCS was tested for target currents 1-6 mA (in 1 mA increments) for 30 min on 5 healthy subjects, and compared with conventional tDCS using 2 mA F3-F4 sponge-electrodes. MRI-derived computational models predicted cortical electric fields. Tolerability was assessed according to the 100 mm visual analogue scale for pain (VASP-100), skin erythema assessment, thermal imaging, and adverse event questionnaires. Results: The electrode design including high-roughness polarity-specific capacity, electrochemically supports high-charge direct current stimulation. In all subjects, HC-tDCS was well tolerated at all tested doses (1-6 mA) with minor transient adverse events and average VASP-100 less than 15. VASP-100 during sponge-electrode tDCS at 2 mA was comparable to 5 and 6 mA HC-tDCS. HC-tDCS operates at significantly lower voltage than sponge-tDCS, impacting tolerability and efficiency. Modeling predicts peak frontal electric fields of 0.65-1.08 V/m for 2 mA HC-tDCS and 1.95-3.25 V/m for 6 mA HC-tDCS, compared to 0.49-0.95 V/m for 2 mA sponge-tDCS. Conclusions: HC-tDCS allows increased cortical stimulation; at 6 mA achieving double the 1 V/m electric field threshold in all subjects. Enabled by pre-stimulation procedures, specialized electrodes, and adaptive low-voltage stimulators, HC-tDCS is well tolerated at intensities up to at least 6 mA.
- 1 January 2025
- Published by The City University of New York
"The Inside History of SCS 1” with Thomas Mortimer
An interview with J. Thomas Mortimer by Marom Bikson on the origins of spinal cord stimulation.
- 1 January 2025
- Published by The City University of New York
"The Inside History of SCS 1” with Thomas Mortimer
An interview with J. Thomas Mortimer by Marom Bikson on the origins of spinal cord stimulation.
- 1 January 2025
- Published by The City University of New York
Marom Bikson interviews Harold Sackeim. Part 1: The emergence of modern ECT. Part 2: Development of ECT. Part 3: Establishment of TMS. Part 4: VNS, DBS, non-invasive targeting and the future
An interview in five parts of Harold Sackeim by Marom Bikson.
- 1 January 2025
- Published by The City University of New York
Marom Bikson interviews Harold Sackeim. Part 1: The emergence of modern ECT. Part 2: Development of ECT. Part 3: Establishment of TMS. Part 4: VNS, DBS, non-invasive targeting and the future
An interview in five parts of Harold Sackeim by Marom Bikson.