Latest Publications
- 1 January 2011
- Published by Elsevier in Physica Medica
- Vol. 27 (1) , 1-10
In vivo dose verification from back projection of a transit dose measurement on the central axis of photon beams
- 1 January 2011
- Published by Elsevier in Physica Medica
- Vol. 27 (1) , 1-10
In vivo dose verification from back projection of a transit dose measurement on the central axis of photon beams
- 1 July 2010
- Published by Elsevier in Bulletin du Cancer
- Vol. 97 (7) , 873-880
La gestion des risques en radiothérapie
Radiation therapy was one of the first medical specialities to implement quality assurance (QA) programs in clinical practice. These QA programs have mainly focused on equipment performance neglecting human factors. Risk management is a relatively new approach in medical disciplines. Methods of evaluation and risk management must be identified, applied and adapted to the specificities of this domain. Based on the experience of industry, risk management will allow us to substantially improve safety and develop our own models of management. Recent experiences use these approaches to implement risk management in radiation therapy departments.
- 1 July 2010
- Published by Elsevier in Bulletin du Cancer
- Vol. 97 (7) , 873-880
La gestion des risques en radiothérapie
Radiation therapy was one of the first medical specialities to implement quality assurance (QA) programs in clinical practice. These QA programs have mainly focused on equipment performance neglecting human factors. Risk management is a relatively new approach in medical disciplines. Methods of evaluation and risk management must be identified, applied and adapted to the specificities of this domain. Based on the experience of industry, risk management will allow us to substantially improve safety and develop our own models of management. Recent experiences use these approaches to implement risk management in radiation therapy departments.
- 1 October 2009
- Published by Elsevier in Cancer/Radiothérapie
- Vol. 13 (6-7) , 574-580
Analyse des risques en radiothérapie
- 1 October 2009
- Published by Elsevier in Cancer/Radiothérapie
- Vol. 13 (6-7) , 574-580
Analyse des risques en radiothérapie
- 18 February 2009
- Published by Wiley in Medical Physics
- Vol. 36 (3) , 816-820
Static and rotational output variation of a tomotherapy unit
- 18 February 2009
- Published by Wiley in Medical Physics
- Vol. 36 (3) , 816-820
Static and rotational output variation of a tomotherapy unit
- Open Access
- 21 February 2006
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 7 (1) , 105-114
Performance optimization of the Varian aS500 EPID system
Today, electronic portal imaging devices (EPIDs) are widely used as a replacement to portal films for patient position verification, but the image quality is not always optimal. The general aim of this study was to optimize the acquisition parameters of an amorphous silicon EPID commercially available for clinical use in radiation therapy with the view to avoid saturation of the system. Special attention was paid to selection of the parameter corresponding to the number of rows acquired between accelerator pulses (NRP) for various beam energies and dose rates. The image acquisition system (IAS2) has been studied, and portal image acquisition was found to be strongly dependent on the accelerator pulse frequency. This frequency is set for each “energy — dose rate” combination of the linear accelerator. For all combinations, the image acquisition parameters were systematically changed to determine their influence on the performances of the Varian aS500 EPID system. New parameters such as the maximum number of rows (MNR) and the number of pulses per frame (NPF) were introduced to explain portal image acquisition theory. Theoretical and experimental values of MNR and NPF were compared, and they were in good agreement. Other results showed that NRP had a major influence on detector saturation and dose per image. A rule of thumb was established to determine the optimum NRP value to be used. This practical application was illustrated by a clinical example in which the saturation of the aSi EPID was avoided by NRP optimization. Moreover, an additional study showed that image quality was relatively insensitive to this parameter.PACS numbers: 87.53.Oq; 87.59.Jq
- 21 February 2006
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 7 (1) , 105-114
Open AccessPerformance optimization of the Varian aS500 EPID system
Today, electronic portal imaging devices (EPIDs) are widely used as a replacement to portal films for patient position verification, but the image quality is not always optimal. The general aim of this study was to optimize the acquisition parameters of an amorphous silicon EPID commercially available for clinical use in radiation therapy with the view to avoid saturation of the system. Special attention was paid to selection of the parameter corresponding to the number of rows acquired between accelerator pulses (NRP) for various beam energies and dose rates. The image acquisition system (IAS2) has been studied, and portal image acquisition was found to be strongly dependent on the accelerator pulse frequency. This frequency is set for each “energy — dose rate” combination of the linear accelerator. For all combinations, the image acquisition parameters were systematically changed to determine their influence on the performances of the Varian aS500 EPID system. New parameters such as the maximum number of rows (MNR) and the number of pulses per frame (NPF) were introduced to explain portal image acquisition theory. Theoretical and experimental values of MNR and NPF were compared, and they were in good agreement. Other results showed that NRP had a major influence on detector saturation and dose per image. A rule of thumb was established to determine the optimum NRP value to be used. This practical application was illustrated by a clinical example in which the saturation of the aSi EPID was avoided by NRP optimization. Moreover, an additional study showed that image quality was relatively insensitive to this parameter.PACS numbers: 87.53.Oq; 87.59.Jq