NRNadja N. Rehak

Nadja N. Rehak

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nadja N. Rehak has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Photolysis of bilirubin in serum specimens exposed to room lighting

    by Nadja N. Rehak, Stacey A. Cecco, Glen L. Hortin


  • Pseudohyperphosphatemia associated with high-dose liposomal amphotericin B therapy

    by Jason W. Lane, Nadja N. Rehak, Glen L. Hortin, Theoklis Zaoutis, Philip R. Krause, Thomas J. Walsh


    • 1 October 1997
      • Vol. 121  (10) , 1087-92

    The effect of smoking on the serum ionized magnesium concentration is method-dependent.

    by Julie Niemela, S A Cecco, N N Rehak, R J Elin

    To investigate the effect of smoking on serum ionized magnesium concentration ([Mg2+]) determined by the NOVA and AVL Mg ion-selective electrodes (Mg ISEs). Subjects were apparently healthy smokers (n = 30) and nonsmokers (n = 30). We determined NOVA and AVL [Mg2+] in their serum and in test solutions containing compounds increased by smoking. We also determined subjects' white blood cell and differential counts. For smokers, the mean values for NOVA and AVL [Mg2+] differed significantly (0.41 vs 0.52 mmol/L, respectively). We found a significant intramethod difference in NOVA [Mg2+] (0.11 mmol/L, P < .0001) between smokers and nonsmokers. A dose-dependent decrease in NOVA [Mg2+] was observed with an increase in cigarettes/day. NOVA [Mg2+] inversely correlated with white blood cell counts. There was no interference by the test compounds with either Mg ISE. Smoking may induce a serum factor, possibly related to white blood cells, that negatively interferes with the response of the NOVA Mg ISE.


  • Open Access

    Thiocyanate in smokers interferes with the Nova magnesium ion-selective electrode

    by Nadja N Rehak, Stacey A Cecco, Julie E Niemela, Ronald J Elin

    Thiocyanate found in serum ordinarily is the metabolite of cyanide that is inhaled with tobacco smoke and ingested with cyanogenic foods. We investigated the effect of the thiocyanate ion (SCN−) on the ionized magnesium (iMg) and ionized calcium (iCa) results determined with the AVL and Nova magnesium and calcium ion-selective electrodes (ISEs). We analyzed saline and pooled serum with added SCN−, and serum from apparently healthy nonsmokers (n = 20) and smokers (n = 20). The mean (and range) of the measured serum SCN− concentration was 0.019 (0.008–0.046) mmol/L for nonsmokers and 0.077 (0.020–0.138) mmol/L for smokers. Only the Nova iMg results decreased with increasing SCN−concentration, and the change was dependent on the baseline iMg concentration. In the absence of Mg, SCN− decreased the voltage response of the Nova Mg ISE to calcium ions. At apparently normal serum iMg and iCa concentrations, the interference by SCN− appeared to be equimolar (iMg = −1.04 × SCN− + 0.52). Thus, the serum SCN− commonly found in smokers causes a significant (P <0.0001) decrease in the Nova iMg results.


    • 1 September 1997
      • Vol. 35  (9) , 701-9

    Falsely high ionized magnesium results by an ion-selective electrode method in severe hypomagnesemia.

    by G Csako, N N Rehak, R J Elin

    Changes in serum total and ionized magnesium (Mg and Mg2+) and calcium (Ca and Ca2+) were monitored in three patients who transiently developed severe (total Mg < 0.50 mmol/l) to profound hypomagnesemia (total Mg < 0.35 mmol/l) due to cisplatin or interleukin-2 therapies. Mg2+ and Ca2+ were measured with the Nova ion-selective electrodes at 37 degrees C and all results were normalized to pH 7.40. Independent of the etiology, the Mg2+ fraction (Mg2+/total Mg) increased as the concentration of the serum total Mg decreased in all three patients. When the total Mg was around or below 0.35 mmol/l the Mg2+ approached or exceeded total Mg, suggesting an error in the measurement of Mg2+. The findings were extended by including a group of 31 additional patients whose serum total Mg, Mg2+, total Ca, and Ca2+ concentrations varied from abnormally low to above normal. The serum total and ionized concentrations strongly correlated for both Mg (r2 = 0.88) and Ca (r2 = 0.92). The Mg2+ fraction rapidly increased with a fall in the total Mg concentration (r2 = 0.76) and total Mg/total Ca ratio (r2 = 0.71). In fact, with decreasing total Mg concentrations or total Mg/total Ca ratios, the Mg2+ fraction progressively increased to 93-128% of the total, confirming an error in the Mg2+ determinations. The Ca2+ fraction showed a slight and insignificant decrease with falling total Ca concentrations and total Mg/total Ca ratios. The Mg2+ concentration was directly related (r2 = 0.62), whereas the Ca2+ concentration showed a complex relationship to the total Mg/total Ca ratio. Whether this latter relationship represents a technical artifact or a true biological phenomenon requires further study. The apparent overestimation of Mg2+ at very low total Mg concentrations, and in the presence of a very low total Mg/total Ca ratio, could be due to improper chemometric correction of the Ca effect on the Mg electrode, non-linearity, and inadequate calibration. Whatever the mechanism, the failure of this method to correctly measure very low serum Mg2+ concentrations in the sera of patients with severe hypomagnesemia, or likely in any patient with an unusually low total Mg/total Ca ratio, erodes its diagnostic usefulness.