BLBrian C.-S. Liu

Brian C.-S. Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Brian C.-S. Liu has a total of 37 co-authors. Here are the top co-authors by number of shared publications:

  • Jerome P. Richie

    Molecular Urology Laboratory, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA

    5 shared publications
  • Joshua R. Ehrlich

    Ophthalmology and Visual Sciences, University of Michigan, Ann Arbor, Michigan, USA

    4 shared publications
  • Robert J. Caiazzo

    Molecular Urology Laboratory, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA

    4 shared publications
  • Michael P. O'LEary

    Molecular Urology Laboratory, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA

    3 shared publications
  • Angeline S. Ferdinand

    Molecular Urology Laboratory, Division of Urology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA

    2 shared publications
  • Bryce P. Nelson

    Gentel Biosciences, Inc

    2 shared publications

Latest Publications

  • Antibody profiling with protein antigen microarrays in early stage cancer

    by Brian C-S Liu, Daniel A DiJohnson, Dennis J O'Rourke

    (2012). Antibody profiling with protein antigen microarrays in early stage cancer. Expert Opinion on Medical Diagnostics: Vol. 6, No. 3, pp. 187-196.


  • Autoantibody signatures as biomarkers to distinguish prostate cancer from benign prostatic hyperplasia in patients with increased serum prostate specific antigen

    by Dennis J. O'ROurke, Daniel A. DiJohnson, Robert J. Caiazzo, James C. Nelson, David Ure, Michael P. O'LEary, Jerome P. Richie, Brian C.-S. Liu


  • Native Antigen Fractionation Protein Microarrays for Biomarker Discovery

    by Robert J. Caiazzo, Dennis J. O’Rourke, Timothy J. Barder, Bryce P. Nelson, Brian C.-S. Liu

    In this protocol, we used the T24 human bladder cancer cell line as a source of native antigens to construct fractionated lysate microarrays. Subsequently, these microarrays were used to compare the autoantibody responses of individuals with interstitial cystitis/painful bladder syndrome (IC/PBS) to those of normal female controls. To accomplish this, T24 cells were lysed under nondenaturing conditions to obtain native antigens. These native antigens were then fractionated in 2D using a PF-2D liquid chromatography; the first dimension separated the proteins by their isoelectric points, and the second separated them according to hydrophobicity. The resulting protein fractions were printed onto nitrocellulose-coated glass slides (PATH slides) to create a set of fractionated lysate microarrays. To compare the autoantibody responses of IC/PBS patients with normal controls, the fractionated lysate arrays were competitively hybridized with fluorescently labeled IgG samples purified from both IC/PBS and control sera. This protocol presents a detailed description of the creation and use of native antigen fractionated lysate microarrays for autoantibody profiling.


  • Microelectrical sensors as emerging platforms for protein biomarker detection in point-of-care diagnostics

    by David L Arruda, William C Wilson, Crystal Nguyen, Qi W Yao, Robert J Caiazzo, Ilie Talpasanu, Douglas E Dow, Brian C-S Liu

    Current methods used to measure protein expression on microarrays, such as labeled fluorescent imaging, are not well suited for real-time, diagnostic measurements at the point of care. Studies have shown that microelectrical sensors utilizing silica nanowire, impedimetric, surface acoustic wave, magnetic nanoparticle and microantenna technologies have the potential to impact disease diagnosis by offering sensing characteristics that rival conventional sensing techniques. Their ability to transduce protein binding events into electrical signals may prove essential for the development of next-generation point-of-care devices for molecular diagnostics, where they could be easily integrated with microarray, microfluidic and telemetry technologies. However, common limitations associated with the microelectrical sensors, including problems with sensor fabrication and sensitivity, must first be resolved. This review describes governing technical concepts and provides examples demonstrating the use of various microelectrical sensors in the diagnosis of disease via protein biomarkers.


  • Protein microarrays as an application for disease biomarkers

    by Robert J. Caiazzo, Andrew J. Maher, Michael P. Drummond, Corey I. Lander, Oliver W. Tassinari, Bryce P. Nelson, Brian C.‐S. Liu

    Protein microarrays are an increasingly powerful technology in the hunt for new and novel diagnostic and prognostic biomarkers. Lending credit to the highly established DNA microarray, protein microarrays are versatile tools that utilize a variety of formats to facilitate the discovery of new biomarkers and our understanding of disease pathways. The aims of this review are: to detail a variety of protein microarray technologies currently used, including forward‐phase technologies and reverse‐phase technologies useful in both the discovery and validation of candidate biomarkers; to explore the strengths and weaknesses of various proteomic microarray platforms; to explain how bioinformatics helps compare data between microarray data sets; and to discuss the downstream applications of such technologies as they relate to the development of a highly personalized approach to medicine.


    • 1 April 2008
      • Vol. 10  (2) , 107-15

    Identifying autoantigens as theranostic targets: antigen arrays and immunoproteomics approaches.

    by Oliver W Tassinari, Robert J Caiazzo, Joshua R Ehrlich, Brian C-S Liu

    The development of theranostics holds great potential for the advancement of personalized medical treatments for human diseases. The theranostic approach combines diagnostic testing with predicted treatment outcomes in order to specifically tailor medical treatments for individual patients. As such, theranostic tests have the potential to revolutionize the diagnosis, treatment and monitoring of human diseases. Currently, the search is underway to identify novel targets for use in the development of theranostic approaches. The aims of this review are: to briefly describe the current capabilities of antigen-autoantibody microarrays, including our native antigen 'reverse-capture' autoantibody microarray platform to identify theranostic targets; to detail other immunoproteomics approaches for the identification of theranostic targets, including serological analysis of antigens by recombinant complementary (c)DNA expression cloning, serological proteome analysis, and autoantibody-mediated identification of antigens; and to provide examples of their use in theranostic discoveries.


  • A native antigen “reverse capture” microarray platform for autoantibody profiling of prostate cancer sera

    by Joshua R. Ehrlich, Robert J. Caiazzo, Weiliang Qiu, Oliver W. Tassinari, Michael P. O'Leary, Jerome P. Richie, Brian C.‐S. Liu

    Cancer sera contain antibodies that react with autologous cellular antigens. Here, we report the use of a novel native antigen-based platform, the “reverse capture” autoantibody microarray, for identification of autoantigens against which autoantibody expression may be used to differentiate between patients with prostate cancer and benign prostate hyperplasia (BPH). Serum samples were collected at our institution from patients with BPH and patients with prostate carcinoma with similar blood prostate-specific antigen levels. IgG was purified from individual prostate cancer sera, differentially labeled with fluorescent dyes, and competitively hybridized against purified IgG from a group of well-characterized BPH control patients on our reverse capture microarray platform. For each experiment, we performed a two-slide dye-swap. Using this platform, we identified 28 unique antigen-autoantibody reactivities that have the potential to discriminate prostate cancer from BPH. These autoantigens, with p-values ≤0.01, can be placed into the following general categories: protein kinases, cell-cycle regulators, cancer-growth factors, apoptosis mediators, and transcription factors. In addition, only 1 of the 28 autoantigens remained differentially targeted by autoantibodies in post-surgical prostate cancer patients after a minimum 1-year follow-up. Autoantibody profiling using this platform may be a useful tool for differentiating between malignant and benign diseases of the prostate.


  • Proteomics approaches to urologic diseases

    by Brian Cs Liu, Joshua R Ehrlich

    Biomarkers are greatly needed for several urologic diseases, such as interstitial cystitis, the symptomatic and clinical progression of benign prostate hyperplasia, as well as the specific detection of urologic cancers, including prostate and bladder cancer. This review aims to: briefly describe the need for biomarkers in the field and biomarkers that are currently available for clinicians; address the limitations and roadblocks to effective biomarker discovery; and provide examples and strategies for implementing biomarkers in clinical practice and/or drug discovery.


  • Development of a “reverse capture” autoantibody microarray for studies of antigen‐autoantibody profiling

    by Shuzhen Qin, Weiliang Qiu, Joshua R. Ehrlich, Angeline S. Ferdinand, Jerome P. Richie, Michael P. O'LEary, Mei‐Ling Ting Lee, Brian C.‐S. Liu

    Diagnosing cancers based on serum profiling is a particularly attractive concept. However, the technical challenges to analysis of the serum proteome arise from the dynamic range of protein amounts. Cancer sera contain antibodies that react with a unique group of autologous cellular antigens, which affords a dramatic amplification of signal in the form of antibodies relative to the amount of the corresponding antigens. The serum autoantibody repertoire from cancer patients might, therefore, be exploited for antigen‐antibody profiling. To date, studies of antigen‐antibody reactivity using microarrays have relied on recombinant proteins or synthetic peptides as arrayed features. However, recombinant proteins and/or synthetic peptides may fail to accurately detect autoantibody binding due to the lack of proper PTMs. Here we describe the development and use of a “reverse capture” autoantibody microarray. Our “reverse capture” autoantibody microarray is based on the dual‐antibody sandwich immunoassay platform of ELISA, which allows the antigens to be immobilized in their native configuration. As “proof‐of‐principle”, we demonstrate its use for antigen‐autoantibody profiling with sera from patients with prostate cancer and benign prostate hyperplasia.


  • Chromatofocusing fractionation and two‐dimensional difference gel electrophoresis for low abundance serum proteins

    by Shuzhen Qin, Angeline S. Ferdinand, Jerome P. Richie, Michael P. O'LEary, Samuel C. Mok, Brian C.‐S. Liu

    The technical challenge to analysis of the serum proteome is that the serum proteins are present at unequal concentrations. A few are so dominant, such as serum albumin and immunoglobulins, that they mask detection of other proteins. Because of these high abundance proteins, current technologies, while theoretically capable of analyzing protein amounts spanning four orders of magnitude, are only able to analyze proteins ranging over two orders of magnitude and cannot analyze the lower abundance proteins that may be the next biomarkers and drug targets. To facilitate the identification of low abundance proteins, we fractionated serum samples from patients with prostate cancer and patients with benign prostate hyperplasia using anion displacement liquid chromatofocusing chromatography, which separates proteins by a pH gradient and a positively charged column. Differential expression of proteins from fractions was then determined and identified by IEF gels and 2‐D DIGE. Results demonstrate improved resolution of proteins within the chosen pH gradient when compared to the unfractionated samples. Several proteins that were differentially expressed in serum from patients with prostate cancer were identified in the fractionated serum. Three of these proteins, squamous cell carcinoma antigen 1 (SCCA1), calgranulin B, and haptoglobin‐related protein, are present in the serum at levels below the classical protein level of mg/mL. SCCA1 is normally expressed in serum at ng/mL levels, and calgranulin B is an intracellular protein. Our results demonstrate that the use of anion displacement liquid chromatofocusing chromatography may reduce the complexity of the serum proteome by separating proteins into distinct pH ranges, and facilitate the identification of low abundance proteins.