Yi-Wei Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yi-Wei Tang has a total of 255 co-authors. Here are the top co-authors by number of shared publications:
Haijing Li
Department of Pathology, Vanderbilt University Medical Center, Nashville, Tennessee, United States of America
38 shared publicationsCharles W. Stratton
Department of Pathology, Vanderbilt University Medical Center, Nashville, Tennessee, United States of America
20 shared publicationsSusan E. Sefers
Ibis Biosciences, Carlsbad, California 92008,1 Departments of Pathology,2 Medicine, Vanderbilt University School of Medicine, Nashville, Tennessee 372323
9 shared publicationsShufang Meng
Departments of Pathology, Vanderbilt University Medical Center, Nashville, Tennessee 37232
6 shared publicationsJian Han
5 shared publicationsHong-Zhou Lu
Department of Infectious Diseases, Fudan University Huashan Hospital,1 Municipal AIDS Research Center, Shanghai Centers for Disease Control and Prevention, Shanghai, China,2 Departments of Medicine and Pathology, Vanderbilt University Medical Center, Nashville, Tennessee3
4 shared publications
Latest Publications
- Open Access
- 8 November 2011
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 6 (11) , e27071
Serum MicroRNA Expression Profile Distinguishes Enterovirus 71 and Coxsackievirus 16 Infections in Patients with Hand-Foot-and-Mouth Disease
Altered circulating microRNA (miRNA) profiles have been noted in patients with microbial infections. We compared host serum miRNA levels in patients with hand-foot-and-mouth disease (HFMD) caused by enterovirus 71 (EV71) and coxsackievirus 16 (CVA16) as well as in other microbial infections and in healthy individuals. Among 664 different miRNAs analyzed using a miRNA array, 102 were up-regulated and 26 were down-regulated in sera of patients with enteroviral infections. Expression levels of ten candidate miRNAs were further evaluated by quantitative real-time PCR assays. A receiver operating characteristic (ROC) curve analysis revealed that six miRNAs (miR-148a, miR-143, miR-324-3p, miR-628-3p, miR-140-5p, and miR-362-3p) were able to discriminate patients with enterovirus infections from healthy controls with area under curve (AUC) values ranged from 0.828 to 0.934. The combined six miRNA using multiple logistic regression analysis provided not only a sensitivity of 97.1% and a specificity of 92.7% but also a unique profile that differentiated enterovirial infections from other microbial infections. Expression levels of five miRNAs (miR-148a, miR-143, miR-324-3p, miR-545, and miR-140-5p) were significantly increased in patients with CVA16 versus those with EV71 (p<0.05). Combination of miR-545, miR-324-3p, and miR-143 possessed a moderate ability to discrimination between CVA16 and EV71 with an AUC value of 0.761. These data indicate that sera from patients with different subtypes of enteroviral infection express unique miRNA profiles. Serum miRNA expression profiles may provide supplemental biomarkers for diagnosing and subtyping enteroviral HFMD infections.
- 8 November 2011
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 6 (11) , e27071
Open AccessSerum MicroRNA Expression Profile Distinguishes Enterovirus 71 and Coxsackievirus 16 Infections in Patients with Hand-Foot-and-Mouth Disease
Altered circulating microRNA (miRNA) profiles have been noted in patients with microbial infections. We compared host serum miRNA levels in patients with hand-foot-and-mouth disease (HFMD) caused by enterovirus 71 (EV71) and coxsackievirus 16 (CVA16) as well as in other microbial infections and in healthy individuals. Among 664 different miRNAs analyzed using a miRNA array, 102 were up-regulated and 26 were down-regulated in sera of patients with enteroviral infections. Expression levels of ten candidate miRNAs were further evaluated by quantitative real-time PCR assays. A receiver operating characteristic (ROC) curve analysis revealed that six miRNAs (miR-148a, miR-143, miR-324-3p, miR-628-3p, miR-140-5p, and miR-362-3p) were able to discriminate patients with enterovirus infections from healthy controls with area under curve (AUC) values ranged from 0.828 to 0.934. The combined six miRNA using multiple logistic regression analysis provided not only a sensitivity of 97.1% and a specificity of 92.7% but also a unique profile that differentiated enterovirial infections from other microbial infections. Expression levels of five miRNAs (miR-148a, miR-143, miR-324-3p, miR-545, and miR-140-5p) were significantly increased in patients with CVA16 versus those with EV71 (p<0.05). Combination of miR-545, miR-324-3p, and miR-143 possessed a moderate ability to discrimination between CVA16 and EV71 with an AUC value of 0.761. These data indicate that sera from patients with different subtypes of enteroviral infection express unique miRNA profiles. Serum miRNA expression profiles may provide supplemental biomarkers for diagnosing and subtyping enteroviral HFMD infections.
- 1 November 2011
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 49 (11) , 3936-3939
Comparative Evaluation of Bruker Biotyper and BD Phoenix Systems for Identification of Bacterial Pathogens Associated with Urinary Tract Infections
The Bruker Biotyper and BD Phoenix systems were evaluated for identification of 1,024 bacterial urinary tract isolates. The Biotyper and Phoenix systems correctly identified 99.9% and 99.5% to the genus level and 99.1% and 98.5% to the species level, respectively. Both systems provide reliable results, and the Biotyper system offers a rapid tool for urine bacterial isolate identification.
- 1 November 2011
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 49 (11) , 3936-3939
Comparative Evaluation of Bruker Biotyper and BD Phoenix Systems for Identification of Bacterial Pathogens Associated with Urinary Tract Infections
The Bruker Biotyper and BD Phoenix systems were evaluated for identification of 1,024 bacterial urinary tract isolates. The Biotyper and Phoenix systems correctly identified 99.9% and 99.5% to the genus level and 99.1% and 98.5% to the species level, respectively. Both systems provide reliable results, and the Biotyper system offers a rapid tool for urine bacterial isolate identification.
- Open Access
- 19 October 2011
- Published by IntechOpen
Pearls and Pitfalls of HIV-1 Serologic Laboratory Testing
- 19 October 2011
- Published by IntechOpen
Open AccessPearls and Pitfalls of HIV-1 Serologic Laboratory Testing
- 1 July 2011
- Published by Canadian Science Publishing in Canadian Journal of Microbiology
- Vol. 57 (7) , 533-538
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry and database for identification of Legionella species 1This study was presented in part at the 110th American Society for Microbiology Annual Meeting, 23–27 May 2010, San Diego, California.
More than 20 species of Legionella have been identified in relation to human infections. Rapid detection and identification of Legionella isolates is clinically useful to differentiate between infection and contamination and to determine treatment regimens. We explored the use of matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) Biotyper system (Bruker Daltonik GmbH, Bremen, Germany) for the identification of Legionella species. The MALDI MS spectra were generated and compared with the Biotyper database, which includes 25 Legionella strains covering 22 species and four Legionella pneumophila serogroups. A total of 83 blind-coded Legionella strains, consisting of 54 reference and 29 clinical strains, were analyzed in the study. Overall, the Biotyper system correctly identified 51 (61.4%) of all strains and isolates to the species level. For species included in the Biotyper database, the method identified 51 (86.4%) strains out of 59 Legionella strains to the correct species level, including 24 (100%) L. pneumophila and 27 (77.1%) non-L. pneumophila strains. The remaining 24 Legionella strains, belonging to species not covered by the Biotyper database, were either identified to the Legionella genus level or had no reliable identification. The Biotyper system produces constant and reproducible MALDI MS spectra for Legionella strains and can be used for rapid and accurate Legionella identification. More Legionella strains, especially the non-L. pneumophila strains, need to be included in the current Biotyper database to cover varieties of Legionella species and to increase identification accuracy.
- 1 July 2011
- Published by Canadian Science Publishing in Canadian Journal of Microbiology
- Vol. 57 (7) , 533-538
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry and database for identification of Legionella species 1This study was presented in part at the 110th American Society for Microbiology Annual Meeting, 23–27 May 2010, San Diego, California.
More than 20 species of Legionella have been identified in relation to human infections. Rapid detection and identification of Legionella isolates is clinically useful to differentiate between infection and contamination and to determine treatment regimens. We explored the use of matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) Biotyper system (Bruker Daltonik GmbH, Bremen, Germany) for the identification of Legionella species. The MALDI MS spectra were generated and compared with the Biotyper database, which includes 25 Legionella strains covering 22 species and four Legionella pneumophila serogroups. A total of 83 blind-coded Legionella strains, consisting of 54 reference and 29 clinical strains, were analyzed in the study. Overall, the Biotyper system correctly identified 51 (61.4%) of all strains and isolates to the species level. For species included in the Biotyper database, the method identified 51 (86.4%) strains out of 59 Legionella strains to the correct species level, including 24 (100%) L. pneumophila and 27 (77.1%) non-L. pneumophila strains. The remaining 24 Legionella strains, belonging to species not covered by the Biotyper database, were either identified to the Legionella genus level or had no reliable identification. The Biotyper system produces constant and reproducible MALDI MS spectra for Legionella strains and can be used for rapid and accurate Legionella identification. More Legionella strains, especially the non-L. pneumophila strains, need to be included in the current Biotyper database to cover varieties of Legionella species and to increase identification accuracy.
- 1 July 2011
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 49 (7) , 2528-2532
Improved Identification of Yeast Species Directly from Positive Blood Culture Media by Combining Sepsityper Specimen Processing and Microflex Analysis with the Matrix-Assisted Laser Desorption Ionization Biotyper System
Current methods for identification of yeast from blood cultures may take several days after these microorganisms have been observed by Gram stain smears from positive blood cultures. We explored the use of a matrix-assisted laser desorption ionization (MALDI) Biotyper system in combination with Sepsityper specimen processing and Microflex analysis for improved detection and identification of yeast species directly from positive blood culture specimens demonstrating yeast-like organisms by Gram stain. The limit of detection of yeast species in blood culture medium was determined to be 5.9 × 10 5 CFU, with intra- and interstrain coefficients of variation of 1.8 to 3.6% and 2.9%, respectively. A total of 42 yeast-containing positive blood culture specimens were processed, and the identification results were compared to those obtained by routinely used phenotypic methods. Specimens with discrepant results between the Biotyper and phenotypic methods were identified on the basis of internal transcribed spacer region sequencing. The MALDI Biotyper system correctly identified the 42 specimens to species level, including 28 (66.7%) Candida albicans , 8 (19.0%) Candida parapsilosis , and 5 (11.9%) Candida tropicalis isolates and 1 (2.4%) Cryptococcus neoformans isolate. The entire procedure, from specimen extraction to final result reporting, can be completed within 1 h. Our data indicated that the Sepsityper specimen processing and Microflex analysis by the MALDI Biotyper system provide a rapid and reliable tool for yeast species identification directly from positive blood culture media.
- 1 July 2011
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 49 (7) , 2528-2532
Improved Identification of Yeast Species Directly from Positive Blood Culture Media by Combining Sepsityper Specimen Processing and Microflex Analysis with the Matrix-Assisted Laser Desorption Ionization Biotyper System
Current methods for identification of yeast from blood cultures may take several days after these microorganisms have been observed by Gram stain smears from positive blood cultures. We explored the use of a matrix-assisted laser desorption ionization (MALDI) Biotyper system in combination with Sepsityper specimen processing and Microflex analysis for improved detection and identification of yeast species directly from positive blood culture specimens demonstrating yeast-like organisms by Gram stain. The limit of detection of yeast species in blood culture medium was determined to be 5.9 × 10 5 CFU, with intra- and interstrain coefficients of variation of 1.8 to 3.6% and 2.9%, respectively. A total of 42 yeast-containing positive blood culture specimens were processed, and the identification results were compared to those obtained by routinely used phenotypic methods. Specimens with discrepant results between the Biotyper and phenotypic methods were identified on the basis of internal transcribed spacer region sequencing. The MALDI Biotyper system correctly identified the 42 specimens to species level, including 28 (66.7%) Candida albicans , 8 (19.0%) Candida parapsilosis , and 5 (11.9%) Candida tropicalis isolates and 1 (2.4%) Cryptococcus neoformans isolate. The entire procedure, from specimen extraction to final result reporting, can be completed within 1 h. Our data indicated that the Sepsityper specimen processing and Microflex analysis by the MALDI Biotyper system provide a rapid and reliable tool for yeast species identification directly from positive blood culture media.
- 1 July 2011
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 49 (7) , 2719-2721
Molecular Characterization of Drug-Resistant Mycobacterium tuberculosis Isolates Circulating in China by Multilocus PCR and Electrospray Ionization Mass Spectrometry
We used multilocus PCR and electrospray ionization mass spectrometry (PCR/ESI-MS) to determine the genotype and drug resistance profiles for 96 Mycobacterium tuberculosis isolates circulating in regions of high and low tuberculosis (TB) endemicity in China. The dominant principal genetic group (PGG) circulating in China was PGG1, and drug-resistant gene mutations were more diversified in the region of low rather than high TB endemicity.
- 1 July 2011
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 49 (7) , 2719-2721
Molecular Characterization of Drug-Resistant Mycobacterium tuberculosis Isolates Circulating in China by Multilocus PCR and Electrospray Ionization Mass Spectrometry
We used multilocus PCR and electrospray ionization mass spectrometry (PCR/ESI-MS) to determine the genotype and drug resistance profiles for 96 Mycobacterium tuberculosis isolates circulating in regions of high and low tuberculosis (TB) endemicity in China. The dominant principal genetic group (PGG) circulating in China was PGG1, and drug-resistant gene mutations were more diversified in the region of low rather than high TB endemicity.
- 1 February 2011
- Published by Springer Nature in Current Infectious Disease Reports
- Vol. 13 (2) , 149-158
Molecular Diagnosis of Viral Respiratory Infections
In clinical practice, a rapid and accurate identification of pathogens causing viral respiratory tract infections can be problematic because of nonspecific clinical presentations, lack of rapid and sensitive tests, and the emergence of new and mutating viral pathogens. Nucleic acid-targeted molecular techniques are increasingly being used to provide high sensitivity and specificity, short test turnaround time, and automatic and high-throughput processing. In-house and commercially available molecular methods have been developed to qualitatively and quantitatively detect and identify a single or a panel of clinically encountered respiratory tract viruses in a single reaction. Molecular techniques are being gradually introduced in routine laboratory diagnosis of viral respiratory tract infections. However, their performance characteristics and limitations must be clearly understood by both laboratory personnel and clinicians to ensure proper utilization and interpretation.
- 1 February 2011
- Published by Springer Nature in Current Infectious Disease Reports
- Vol. 13 (2) , 149-158
Molecular Diagnosis of Viral Respiratory Infections
In clinical practice, a rapid and accurate identification of pathogens causing viral respiratory tract infections can be problematic because of nonspecific clinical presentations, lack of rapid and sensitive tests, and the emergence of new and mutating viral pathogens. Nucleic acid-targeted molecular techniques are increasingly being used to provide high sensitivity and specificity, short test turnaround time, and automatic and high-throughput processing. In-house and commercially available molecular methods have been developed to qualitatively and quantitatively detect and identify a single or a panel of clinically encountered respiratory tract viruses in a single reaction. Molecular techniques are being gradually introduced in routine laboratory diagnosis of viral respiratory tract infections. However, their performance characteristics and limitations must be clearly understood by both laboratory personnel and clinicians to ensure proper utilization and interpretation.
- 1 January 2011
- Vol. 41 (2) , 161-6
Identification and characterization of OXA-48 producing, carbapenem-resistant Enterobacteriaceae isolates in Turkey.
Carbapenem resistance in Enterobacteriaceae isolates has been reported from Turkey and is most often mediated by OXA-48 type carbapenemases. We report the identification and characterization of four carbapenem-resistant isolates (three Klebsiella pneumoniae and one Escherichia coli) among 515 clinical Enterobacteriaceae isolates collected during a 7-month study period in Ankara, Turkey. The four isolates were recovered from blood and urine specimens in patients with varied clinical manifestations. They had distinct pulsed-field gel electrophoresis patterns and harbored a variety of β-lactamases including bla(TEM-1), bla(SHV-12) genes, bla(SHV-11), and/or bla(CTX-M-15). PCR and sequencing analysis revealed that the bla(OXA-48) gene was present in all four isolates. Our data indicated that the OXA-48-type carbapenemase was the only mechanism for carbapenem resistance in our hospital.
- 1 January 2011
- Vol. 41 (2) , 161-6
Identification and characterization of OXA-48 producing, carbapenem-resistant Enterobacteriaceae isolates in Turkey.
Carbapenem resistance in Enterobacteriaceae isolates has been reported from Turkey and is most often mediated by OXA-48 type carbapenemases. We report the identification and characterization of four carbapenem-resistant isolates (three Klebsiella pneumoniae and one Escherichia coli) among 515 clinical Enterobacteriaceae isolates collected during a 7-month study period in Ankara, Turkey. The four isolates were recovered from blood and urine specimens in patients with varied clinical manifestations. They had distinct pulsed-field gel electrophoresis patterns and harbored a variety of β-lactamases including bla(TEM-1), bla(SHV-12) genes, bla(SHV-11), and/or bla(CTX-M-15). PCR and sequencing analysis revealed that the bla(OXA-48) gene was present in all four isolates. Our data indicated that the OXA-48-type carbapenemase was the only mechanism for carbapenem resistance in our hospital.
- 1 November 2010
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 48 (11) , 4129-4134
Assessment of Clostridium difficile Infections by Quantitative Detection of tcdB Toxin by Use of a Real-Time Cell Analysis System
We explored the use of a real-time cell analysis (RTCA) system for the assessment of Clostridium difficile toxins in human stool specimens by monitoring the dynamic responses of the HS27 cells to tcdB toxins. The C. difficile toxin caused cytotoxic effects on the cells, which resulted in a dose-dependent and time-dependent decrease in cell impedance. The RTCA assay possessed an analytical sensitivity of 0.2 ng/ml for C. difficile toxin B with no cross-reactions with other enterotoxins, nontoxigenic C. difficile , or other Clostridum species. Clinical validation was performed on 300 consecutively collected stool specimens from patients with suspected C. difficile infection (CDI). Each stool specimen was tested in parallel by a real-time PCR assay (PCR), a dual glutamate dehydrogenase and toxin A/B enzyme immunoassay (EIA), and the RTCA assay. In comparison to a reference standard in a combination of the three assays, the RTCA had a specificity of 99.6% and a sensitivity of 87.5% (28 of 32), which was higher than the EIA result ( P = 0.005) but lower than the PCR result ( P = 0.057). In addition, the RTCA assay allowed for quantification of toxin protein concentration in a given specimen. Among RTCA-positive specimens collected prior to treatment with metronidazole and/or vancomycin, a significant correlation between toxin protein concentrations and clinical CDI severities was observed ( R 2 = 0.732, P = 0.0004). Toxin concentrations after treatment (0.89 ng/ml) were significantly lower than those prior to the treatment (15.68 ng/ml, Wilcoxon P = 0.01). The study demonstrates that the RTCA assay provides a functional tool for the potential assessment of C. difficile infections.
- 1 November 2010
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 48 (11) , 4129-4134
Assessment of Clostridium difficile Infections by Quantitative Detection of tcdB Toxin by Use of a Real-Time Cell Analysis System
We explored the use of a real-time cell analysis (RTCA) system for the assessment of Clostridium difficile toxins in human stool specimens by monitoring the dynamic responses of the HS27 cells to tcdB toxins. The C. difficile toxin caused cytotoxic effects on the cells, which resulted in a dose-dependent and time-dependent decrease in cell impedance. The RTCA assay possessed an analytical sensitivity of 0.2 ng/ml for C. difficile toxin B with no cross-reactions with other enterotoxins, nontoxigenic C. difficile , or other Clostridum species. Clinical validation was performed on 300 consecutively collected stool specimens from patients with suspected C. difficile infection (CDI). Each stool specimen was tested in parallel by a real-time PCR assay (PCR), a dual glutamate dehydrogenase and toxin A/B enzyme immunoassay (EIA), and the RTCA assay. In comparison to a reference standard in a combination of the three assays, the RTCA had a specificity of 99.6% and a sensitivity of 87.5% (28 of 32), which was higher than the EIA result ( P = 0.005) but lower than the PCR result ( P = 0.057). In addition, the RTCA assay allowed for quantification of toxin protein concentration in a given specimen. Among RTCA-positive specimens collected prior to treatment with metronidazole and/or vancomycin, a significant correlation between toxin protein concentrations and clinical CDI severities was observed ( R 2 = 0.732, P = 0.0004). Toxin concentrations after treatment (0.89 ng/ml) were significantly lower than those prior to the treatment (15.68 ng/ml, Wilcoxon P = 0.01). The study demonstrates that the RTCA assay provides a functional tool for the potential assessment of C. difficile infections.
- 1 November 2010
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 48 (11) , 3888-3892
Mass Spectrometry Biotyper System Identifies Enteric Bacterial Pathogens Directly from Colonies Grown on Selective Stool Culture Media
We evaluated the performance and cost-effectiveness of a matrix-assisted laser desorption ionization time-of-flight mass spectrometry-based Biotyper system for the routine identification of common enteric bacterial pathogens seen in middle Tennessee from suspicious colonies grown on selective stool culture media. A total of 304 suspicious colonies were selected and further identified from 605 stool specimens. The suspicious colonies were analyzed by the Biotyper system, and the results were compared to those from routine phenotypic methods, which identified 22 Salmonella species, 39 Shigella species, 3 enterohemorrhagic Escherichia coli (EHEC) isolates, 2 Yersinia enterocolitica isolates, 2 Campylobacter species, and 236 gastrointestinal normal flora isolates. The Biotyper system correctly identified the Salmonella species, Yersinia enterocolitica , and Campylobacter species but failed to distinguish the Shigella species and EHEC isolates from E. coli . Among the 236 normal flora isolates, 233 (98.7%) and 228 (96.6%) agreed at the genus and species levels, respectively, between the phenotypic and Biotyper methods. Organism identification scores were insignificantly different between colonies directly from selective media and subsequently from pure subculture. The entire Biotyper identification procedure, from smear preparation to final result reporting, can be completed within 30 min. The Biotyper system provides a rapid and simple screening tool for identifying many, but not all, suspicious colonies grown on selective media within 24 h after inoculation, which shortens test turnaround time by 2 to 3 days.
- 1 November 2010
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 48 (11) , 3888-3892
Mass Spectrometry Biotyper System Identifies Enteric Bacterial Pathogens Directly from Colonies Grown on Selective Stool Culture Media
We evaluated the performance and cost-effectiveness of a matrix-assisted laser desorption ionization time-of-flight mass spectrometry-based Biotyper system for the routine identification of common enteric bacterial pathogens seen in middle Tennessee from suspicious colonies grown on selective stool culture media. A total of 304 suspicious colonies were selected and further identified from 605 stool specimens. The suspicious colonies were analyzed by the Biotyper system, and the results were compared to those from routine phenotypic methods, which identified 22 Salmonella species, 39 Shigella species, 3 enterohemorrhagic Escherichia coli (EHEC) isolates, 2 Yersinia enterocolitica isolates, 2 Campylobacter species, and 236 gastrointestinal normal flora isolates. The Biotyper system correctly identified the Salmonella species, Yersinia enterocolitica , and Campylobacter species but failed to distinguish the Shigella species and EHEC isolates from E. coli . Among the 236 normal flora isolates, 233 (98.7%) and 228 (96.6%) agreed at the genus and species levels, respectively, between the phenotypic and Biotyper methods. Organism identification scores were insignificantly different between colonies directly from selective media and subsequently from pure subculture. The entire Biotyper identification procedure, from smear preparation to final result reporting, can be completed within 30 min. The Biotyper system provides a rapid and simple screening tool for identifying many, but not all, suspicious colonies grown on selective media within 24 h after inoculation, which shortens test turnaround time by 2 to 3 days.