Hansjörg Rempp
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hansjörg Rempp has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
Stephan Clasen
Department on Diagnostic and Interventional Radiology, Eberhard Karls University of Tübingen, Hoppe-Seyler-Straße 3, 72076 Tübingen, Germany
9 shared publicationsClaus D. Claussen
Department on Diagnostic and Interventional Radiology, Eberhard Karls University of Tübingen, Hoppe-Seyler-Straße 3, 72076 Tübingen, Germany
8 shared publicationsPhilippe L. Pereira
Clinic for radiology, Nuclear Medicine and Minimal Invasive Therapies, SLK-Clinics, Heilbronn, Germany
7 shared publicationsRüdiger Hoffmann
Department on Diagnostic and Interventional Radiology, Eberhard Karls University of Tübingen, Hoppe-Seyler-Straße 3, 72076 Tübingen, Germany
6 shared publicationsMarkus D. Enderle
Erbe Elektromedizin GmbH, Tübingen, Germany
4 shared publicationsMarcus Scharpf
Department on General Pathology and Pathological Anatomy, Institute of Pathology, Eberhard Karls University of Tübingen, Tübingen, Germany
3 shared publications
Latest Publications
- 1 October 2014
- Published by Elsevier in European Journal of Radiology
- Vol. 83 (10) , 1793-1798
Transarterial chemoembolization using drug eluting beads and subsequent percutaneous MR-guided radiofrequency ablation in the therapy of intermediate sized hepatocellular carcinoma
- 1 October 2014
- Published by Elsevier in European Journal of Radiology
- Vol. 83 (10) , 1793-1798
Transarterial chemoembolization using drug eluting beads and subsequent percutaneous MR-guided radiofrequency ablation in the therapy of intermediate sized hepatocellular carcinoma
- 1 May 2014
- Published by Elsevier in Academic Radiology
- Vol. 21 (5) , 661-666
A Comparison of Internally Water-perfused and Cryogenically Cooled Monopolar and Bipolar Radiofrequency Applicators in Ex Vivo Liver Samples
- 1 May 2014
- Published by Elsevier in Academic Radiology
- Vol. 21 (5) , 661-666
A Comparison of Internally Water-perfused and Cryogenically Cooled Monopolar and Bipolar Radiofrequency Applicators in Ex Vivo Liver Samples
- 1 January 2014
- Published by Elsevier in European Journal of Radiology
- Vol. 83 (1) , 111-116
Image-guided radiofrequency ablation of hepatocellular carcinoma (HCC): Is MR guidance more effective than CT guidance?
- 1 January 2014
- Published by Elsevier in European Journal of Radiology
- Vol. 83 (1) , 111-116
Image-guided radiofrequency ablation of hepatocellular carcinoma (HCC): Is MR guidance more effective than CT guidance?
- Open Access
- 25 November 2013
- Published by Springer Nature in BMC Neurology
- Vol. 13 (1) , 185
Encephalopathic Susac’s Syndrome associated with livedo racemosa in a young woman before the completion of family planning
Susac’s Syndrome (SS) consists of the triad of encephalopathy, branch retinal artery occlusions (BRAO) and hearing loss (HL). Histopathologically, SS is characterised by a microangiopathy, and some observations suggest that an immune-mediated damage of endothelial cells might play a role. These findings also implicate a similarity between SS and other autoimmune diseases, most notably juvenile dermatomyositis (JDM). However, SS and JDM are commonly thought to affect distinct and non-overlapping sets of organs, and it is currently not clear how these specificities arise. Moreover, in the absence of clinical trials, some authors suggest that therapeutic approaches in SS should rely on the model of other autoimmune diseases such as JDM.
- 25 November 2013
- Published by Springer Nature in BMC Neurology
- Vol. 13 (1) , 185
Open AccessEncephalopathic Susac’s Syndrome associated with livedo racemosa in a young woman before the completion of family planning
Susac’s Syndrome (SS) consists of the triad of encephalopathy, branch retinal artery occlusions (BRAO) and hearing loss (HL). Histopathologically, SS is characterised by a microangiopathy, and some observations suggest that an immune-mediated damage of endothelial cells might play a role. These findings also implicate a similarity between SS and other autoimmune diseases, most notably juvenile dermatomyositis (JDM). However, SS and JDM are commonly thought to affect distinct and non-overlapping sets of organs, and it is currently not clear how these specificities arise. Moreover, in the absence of clinical trials, some authors suggest that therapeutic approaches in SS should rely on the model of other autoimmune diseases such as JDM.
- 29 October 2013
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 40 (2) , 432-439
Liver lesion conspicuity during real-time MR-guided radiofrequency applicator placement using spoiled gradient echo and balanced steady-state free precession imaging
Purpose To retrospectively evaluate the conspicuity of liver lesions in a fluoroscopic spoiled gradient echo (GRE) and a balanced steady‐state free precession (SSFP) magnetic resonance imaging (MRI) sequence. Materials and Methods In all, 103 patients with hepatocellular carcinomas (HCC) (41) or liver metastases (67) were treated using MR‐guided radiofrequency ablation in a wide‐bore 1.5 T scanner. A multislice real‐time spoiled GRE sequence allowing for a T1 weighting (T1W) and a balanced SSFP sequence allowing for a T2/T1W contrast were used for MR guidance. The contrast‐to‐noise‐ratio (CNR) of the lesions was calculated and lesion conspicuity was assessed retrospectively (easily detectable / difficult to detect / not detectable). Results HCC was easily detectable in 33/52% (GRE/SSFP), difficult to detect in 30/18%, and not detectable in 37/30% of the cases. Mean CNR varied widely (9.1 for GRE vs. 16.4 for SSFP). Liver metastases were easily detectable in 58/41% (GRE/SSFP), difficult to detect in 14/21%, and not detectable in 28/38% of the cases. Mean CNR for liver metastases was 11.5 (GRE) vs. 12.7 (SSFP). Twenty percent of all lesions could not be detected with either of the MR fluoroscopy sequences. Conclusion MR fluoroscopy using GRE and SSFP contrast enabled real‐time detectability of 80% of the liver lesions. J. Magn. Reson. Imaging 2014;40:432–439.
- 29 October 2013
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 40 (2) , 432-439
Liver lesion conspicuity during real-time MR-guided radiofrequency applicator placement using spoiled gradient echo and balanced steady-state free precession imaging
Purpose To retrospectively evaluate the conspicuity of liver lesions in a fluoroscopic spoiled gradient echo (GRE) and a balanced steady‐state free precession (SSFP) magnetic resonance imaging (MRI) sequence. Materials and Methods In all, 103 patients with hepatocellular carcinomas (HCC) (41) or liver metastases (67) were treated using MR‐guided radiofrequency ablation in a wide‐bore 1.5 T scanner. A multislice real‐time spoiled GRE sequence allowing for a T1 weighting (T1W) and a balanced SSFP sequence allowing for a T2/T1W contrast were used for MR guidance. The contrast‐to‐noise‐ratio (CNR) of the lesions was calculated and lesion conspicuity was assessed retrospectively (easily detectable / difficult to detect / not detectable). Results HCC was easily detectable in 33/52% (GRE/SSFP), difficult to detect in 30/18%, and not detectable in 37/30% of the cases. Mean CNR varied widely (9.1 for GRE vs. 16.4 for SSFP). Liver metastases were easily detectable in 58/41% (GRE/SSFP), difficult to detect in 14/21%, and not detectable in 28/38% of the cases. Mean CNR for liver metastases was 11.5 (GRE) vs. 12.7 (SSFP). Twenty percent of all lesions could not be detected with either of the MR fluoroscopy sequences. Conclusion MR fluoroscopy using GRE and SSFP contrast enabled real‐time detectability of 80% of the liver lesions. J. Magn. Reson. Imaging 2014;40:432–439.
- 1 August 2013
- Published by Elsevier in European Journal of Radiology
- Vol. 82 (8) , e350-e355
Internally gas-cooled radiofrequency applicators as an alternative to conventional radiofrequency and microwave ablation devices: An in vivo comparison
- 1 August 2013
- Published by Elsevier in European Journal of Radiology
- Vol. 82 (8) , e350-e355
Internally gas-cooled radiofrequency applicators as an alternative to conventional radiofrequency and microwave ablation devices: An in vivo comparison
- 1 June 2013
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 48 (6) , 429-436
Therapy Monitoring of Magnetic Resonance–Guided Radiofrequency Ablation Using T1- and T2-Weighted Sequences at 1.5 T
The aim of this study was to compare the size and shape of the indicated ablation zone using magnetic resonance (MR) imaging with different contrast weightings after MR-guided radiofrequency ablation (RFA) at 1.5 T. Magnetic resonance images of 50 patients treated for hepatic malignancies using MR-guided RFA were retrospectively evaluated. Areas indicating ablation zones in contrast-enhanced images were compared with nonenhanced T1- and T2-weighted images acquired after the intervention and 1 and 7 months after therapy. Corresponding slices were selected and registered to each other. Regions indicating ablation zones were segmented and compared. Areas in cm, positive predictive value, and sensitivity of native T1- and T2-weighted images were calculated with regard to their accordance with the contrast-enhanced images. Directly after the intervention, the ratios between the areas of the ablation zone in the contrast-enhanced and the tested sequences were 1.02 ± 0.12 in the T1-weighted images and 2.03 ± 0.78 in the T2-weighted images. Sensitivity (portion of the coagulation zone that was correctly detected based on the tested sequences) was 0.88 ± 0.08 using the T1-weighted and 0.54 ± 0.20 using the T2-weighted images. The positive predictive values were 0.89 ± 0.06 (T1 weighted) and 0.93 ± 0.06 (T2 weighted). One month after therapy, the ratios between the areas in the contrast-enhanced and the tested sequences were 1.02 ± 0.12 in the T1-weighted images and 1.04 ± 0.25 in the T2-weighted images. Seven months after therapy, the ratios were 1.04 ± 0.16 in the T1-weighted and 1.18 ± 0.22 in the T2-weighted images. In examinations performed directly after the intervention, the T2-weighted images tend to underestimate the ablation zone, whereas T1-weighted images clearly better reflect the ablation zone. T1-weighted images therefore seem more adequate for repetitive monitoring of MR-guided RFA at 1.5 T.
- 1 June 2013
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 48 (6) , 429-436
Therapy Monitoring of Magnetic Resonance–Guided Radiofrequency Ablation Using T1- and T2-Weighted Sequences at 1.5 T
The aim of this study was to compare the size and shape of the indicated ablation zone using magnetic resonance (MR) imaging with different contrast weightings after MR-guided radiofrequency ablation (RFA) at 1.5 T. Magnetic resonance images of 50 patients treated for hepatic malignancies using MR-guided RFA were retrospectively evaluated. Areas indicating ablation zones in contrast-enhanced images were compared with nonenhanced T1- and T2-weighted images acquired after the intervention and 1 and 7 months after therapy. Corresponding slices were selected and registered to each other. Regions indicating ablation zones were segmented and compared. Areas in cm, positive predictive value, and sensitivity of native T1- and T2-weighted images were calculated with regard to their accordance with the contrast-enhanced images. Directly after the intervention, the ratios between the areas of the ablation zone in the contrast-enhanced and the tested sequences were 1.02 ± 0.12 in the T1-weighted images and 2.03 ± 0.78 in the T2-weighted images. Sensitivity (portion of the coagulation zone that was correctly detected based on the tested sequences) was 0.88 ± 0.08 using the T1-weighted and 0.54 ± 0.20 using the T2-weighted images. The positive predictive values were 0.89 ± 0.06 (T1 weighted) and 0.93 ± 0.06 (T2 weighted). One month after therapy, the ratios between the areas in the contrast-enhanced and the tested sequences were 1.02 ± 0.12 in the T1-weighted images and 1.04 ± 0.25 in the T2-weighted images. Seven months after therapy, the ratios were 1.04 ± 0.16 in the T1-weighted and 1.18 ± 0.22 in the T2-weighted images. In examinations performed directly after the intervention, the T2-weighted images tend to underestimate the ablation zone, whereas T1-weighted images clearly better reflect the ablation zone. T1-weighted images therefore seem more adequate for repetitive monitoring of MR-guided RFA at 1.5 T.
- 25 April 2012
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 184 (S 01) , WI_PO27
MRT-Temperaturmessung bei Radiofrequenzablation von Lebertumoren: Korrelation der Temperaturdaten mit der Ablationszone
Ziele: Bei MRT-gestützter Radiofrequenzablation (RFA) von Lebertumoren können mithilfe thermosensitiver Sequenzen Temperaturkarten erzeugt werden. Ziel dieser Arbeit ist die Untersuchung der Sensitivität und der positiven Vorhersagekraft unterschiedlicher Temperaturschwellenwerte im Hinblick auf eine Vorhersage der Ablationszone. Methode: 24 Patienten mit sekundären Lebertumoren wurden an einem weitgebohrten 1,5 T Kernspintomographen mit RFA behandelt. Nach Energieapplikation wurden 72 Temperaturkarten der Leber in unterschiedlichen Angulierungen mittels Protonresonanzfrequenzmethode akquiriert und auf identische Schichten der kontrastangehobenen postinterventionellen MRT-Untersuchung registriert. Zonen mit Temperaturen über 50°, 55° und 60°C wurden in den Temperaturkarten softwaregestützt segmentiert und mit den minderperfundierten Ablationsarealen verglichen. Der positive Vorhersagewert und die Sensitivität der einzelnen Temperaturschwellenwerte wurden ermittelt. Die Ergebnisse wurden mit einem Mann-Whitney-U-Test verglichen. Ergebnis: 61/72 Temperaturkarten waren diagnostisch verwertbar. Der positive Vorhersagewert beschreibt den Anteil eines Areals in der Temperaturkarte oberhalb eines bestimmten Schwellenwerts, der die Ablationszone korrekt wiedergibt. Bei einem Schwellenwert von 50°C lag dieser Wert bei 71±16% und stieg auf 87±9% beim 60°C-Schwellenwert (p=0,00002). Für Pixel mit Temperaturwerten von 50–60°C lag der Vorhersagewert bei 23±17%. Die Sensitivität beschreibt den Anteil der Ablationszone, der in den Temperaturkarten Temperaturen oberhalb des Schwellenwerts aufwies; dieser Anteil lag zwischen 81±12% bei 60°C und 88±12% bei 50°C (p=0,0002). Das Flächenverhältnis zwischen segmentierter Temperaturzone und Ablationszone lag für 50°C bei 1.32±0.38 und für 60°C bei 0.96±0.13. Schlussfolgerung: Ein Temperaturschwellenwert von 60°C ist unter den getesteten Werten am ehesten geeignet, die Ablationszone vorherzusagen. Schwellenwerte von 50 und 55°C können zu einer Überschätzung der Ablationszone führen. Keywords: MRT-Thermometrie, MR-Temperaturmapping, Radiofrequenzablation, Protonenresonanzfrequenzmethode, MR-Interventionen Korrespondierender Autor: Rempp H Universitätsklinikum Tübingen, Diagnostische und Interventionelle Radiologie, Hoppe-Seyler-Straße 3, 72076 Tübingen E-Mail: hansjoerg.rempp@med.uni-tuebingen.de
- 25 April 2012
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 184 (S 01) , WI_PO27
MRT-Temperaturmessung bei Radiofrequenzablation von Lebertumoren: Korrelation der Temperaturdaten mit der Ablationszone
Ziele: Bei MRT-gestützter Radiofrequenzablation (RFA) von Lebertumoren können mithilfe thermosensitiver Sequenzen Temperaturkarten erzeugt werden. Ziel dieser Arbeit ist die Untersuchung der Sensitivität und der positiven Vorhersagekraft unterschiedlicher Temperaturschwellenwerte im Hinblick auf eine Vorhersage der Ablationszone. Methode: 24 Patienten mit sekundären Lebertumoren wurden an einem weitgebohrten 1,5 T Kernspintomographen mit RFA behandelt. Nach Energieapplikation wurden 72 Temperaturkarten der Leber in unterschiedlichen Angulierungen mittels Protonresonanzfrequenzmethode akquiriert und auf identische Schichten der kontrastangehobenen postinterventionellen MRT-Untersuchung registriert. Zonen mit Temperaturen über 50°, 55° und 60°C wurden in den Temperaturkarten softwaregestützt segmentiert und mit den minderperfundierten Ablationsarealen verglichen. Der positive Vorhersagewert und die Sensitivität der einzelnen Temperaturschwellenwerte wurden ermittelt. Die Ergebnisse wurden mit einem Mann-Whitney-U-Test verglichen. Ergebnis: 61/72 Temperaturkarten waren diagnostisch verwertbar. Der positive Vorhersagewert beschreibt den Anteil eines Areals in der Temperaturkarte oberhalb eines bestimmten Schwellenwerts, der die Ablationszone korrekt wiedergibt. Bei einem Schwellenwert von 50°C lag dieser Wert bei 71±16% und stieg auf 87±9% beim 60°C-Schwellenwert (p=0,00002). Für Pixel mit Temperaturwerten von 50–60°C lag der Vorhersagewert bei 23±17%. Die Sensitivität beschreibt den Anteil der Ablationszone, der in den Temperaturkarten Temperaturen oberhalb des Schwellenwerts aufwies; dieser Anteil lag zwischen 81±12% bei 60°C und 88±12% bei 50°C (p=0,0002). Das Flächenverhältnis zwischen segmentierter Temperaturzone und Ablationszone lag für 50°C bei 1.32±0.38 und für 60°C bei 0.96±0.13. Schlussfolgerung: Ein Temperaturschwellenwert von 60°C ist unter den getesteten Werten am ehesten geeignet, die Ablationszone vorherzusagen. Schwellenwerte von 50 und 55°C können zu einer Überschätzung der Ablationszone führen. Keywords: MRT-Thermometrie, MR-Temperaturmapping, Radiofrequenzablation, Protonenresonanzfrequenzmethode, MR-Interventionen Korrespondierender Autor: Rempp H Universitätsklinikum Tübingen, Diagnostische und Interventionelle Radiologie, Hoppe-Seyler-Straße 3, 72076 Tübingen E-Mail: hansjoerg.rempp@med.uni-tuebingen.de
- 18 April 2012
- Published by Springer Nature in European Radiology
- Vol. 22 (9) , 1972-1982
MR-guided radiofrequency ablation using a wide-bore 1.5-T MR system: clinical results of 213 treated liver lesions
Objective To evaluate the technical effectiveness, technical success and patient safety of MR-guided radiofrequency (RF) ablation of liver malignancies using a wide-bore 1.5-T MR system. Methods In 110 patients, 56 primary liver lesions and 157 liver metastases were treated in 157 sessions using percutaneous RF ablation. Mean lesion diameter was 20 mm (range 4–54 mm). All planning, procedural and post-interventional control MR investigations were carried out using a wide-bore 1.5-T MR system. Technical success was assessed by a contrast-enhanced MR liver examination immediately after the intervention. Technique effectiveness was assessed by dynamic hepatic MR study 1 month post ablation; mean follow-up period was 24.2 months (range 5–44). Results Technical success and technique effectiveness were achieved in 210/213 lesions (98.6 %). In 18/210 lesions (8.6 %), local tumour progression occurred 4–28 months after therapy. Seven of these 18 lesions were treated in a second session achieving complete ablation, 6 other lesions were referred to surgery. Overall RF effectiveness rate was 199/213 (93.4 %); overall therapy success (including surgery) was 205/213 (96.2 %). Two major complications (1.3 %) (bleeding and infected biloma) and 14 (8.9 %) minor complications occurred subsequent to 157 interventions. Conclusion Wide-bore MR-guided RF ablation is a safe and effective treatment option for liver lesions. Key Points • Magnetic resonance-guided radiofrequency ablation offers various options for monitoring therapy. • All steps of RF ablation carried out in 1.5-T wide-bore system. • Therapeutic decisions were based on T1-weighted imaging. • Technical success and technical effectiveness were high. • Local tumour progression rate was 8.6 % over a 24-month mean follow-up.
- 18 April 2012
- Published by Springer Nature in European Radiology
- Vol. 22 (9) , 1972-1982
MR-guided radiofrequency ablation using a wide-bore 1.5-T MR system: clinical results of 213 treated liver lesions
Objective To evaluate the technical effectiveness, technical success and patient safety of MR-guided radiofrequency (RF) ablation of liver malignancies using a wide-bore 1.5-T MR system. Methods In 110 patients, 56 primary liver lesions and 157 liver metastases were treated in 157 sessions using percutaneous RF ablation. Mean lesion diameter was 20 mm (range 4–54 mm). All planning, procedural and post-interventional control MR investigations were carried out using a wide-bore 1.5-T MR system. Technical success was assessed by a contrast-enhanced MR liver examination immediately after the intervention. Technique effectiveness was assessed by dynamic hepatic MR study 1 month post ablation; mean follow-up period was 24.2 months (range 5–44). Results Technical success and technique effectiveness were achieved in 210/213 lesions (98.6 %). In 18/210 lesions (8.6 %), local tumour progression occurred 4–28 months after therapy. Seven of these 18 lesions were treated in a second session achieving complete ablation, 6 other lesions were referred to surgery. Overall RF effectiveness rate was 199/213 (93.4 %); overall therapy success (including surgery) was 205/213 (96.2 %). Two major complications (1.3 %) (bleeding and infected biloma) and 14 (8.9 %) minor complications occurred subsequent to 157 interventions. Conclusion Wide-bore MR-guided RF ablation is a safe and effective treatment option for liver lesions. Key Points • Magnetic resonance-guided radiofrequency ablation offers various options for monitoring therapy. • All steps of RF ablation carried out in 1.5-T wide-bore system. • Therapeutic decisions were based on T1-weighted imaging. • Technical success and technical effectiveness were high. • Local tumour progression rate was 8.6 % over a 24-month mean follow-up.
- 22 November 2011
- Published by Springer Nature in European Radiology
- Vol. 22 (5) , 1091-1100
Threshold-based prediction of the coagulation zone in sequential temperature mapping in MR-guided radiofrequency ablation of liver tumours
To evaluate different cut-off temperature levels for a threshold-based prediction of the coagulation zone in magnetic resonance (MR)-guided radiofrequency (RF) ablation of liver tumours.
- 22 November 2011
- Published by Springer Nature in European Radiology
- Vol. 22 (5) , 1091-1100
Threshold-based prediction of the coagulation zone in sequential temperature mapping in MR-guided radiofrequency ablation of liver tumours
To evaluate different cut-off temperature levels for a threshold-based prediction of the coagulation zone in magnetic resonance (MR)-guided radiofrequency (RF) ablation of liver tumours.