Werner A. Kaiser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Werner A. Kaiser has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Harald Fischer
Institute for Medical Engineering and Biophysics, Karlsruhe Research Center, Karlsruhe, Germany
3 shared publications- Pascal Andreas Thomas Baltzer
Department of Biomedical Imaging and Image-guided Therapy, Division of General and Pediatric Radiology, Medical University of Vienna, 1090 Vienna, Austria
3 shared publications Achim Schneider
Department of Gynecology, Friedrich‐Schiller‐University Jena, Jena, Germany
2 shared publications- Ansgar Malich
Institute of Diagnostic Radiology, Suedharz-Hospital Nordhausen, Dr.-R.-Koch-Street 38, 99734 Nordhausen, Germany
2 shared publications - Christiane Marx
Institute of Diagnostic and Interventional Radiology, Friedrich Schiller University of Jena, 07740 Jena, Germany
2 shared publications Jörg Vagner
Institute for Medical Engineering and Biophysics, Karlsruhe Research Center, Karlsruhe, Germany
2 shared publications
Latest Publications
- 18 November 2014
- Published by Elsevier in Clinical Imaging
- Vol. 39 (2) , 225-230
4D co-registration of X-ray and MR-mammograms: initial clinical results and potential incremental diagnostic value
- 18 November 2014
- Published by Elsevier in Clinical Imaging
- Vol. 39 (2) , 225-230
4D co-registration of X-ray and MR-mammograms: initial clinical results and potential incremental diagnostic value
- 31 July 2012
- Published by Elsevier in European Journal of Radiology
- Vol. 81 (7) , 1508-1513
Artificial Neural Networks for differential diagnosis of breast lesions in MR-Mammography: A systematic approach addressing the influence of network architecture on diagnostic performance using a large clinical database
- 31 July 2012
- Published by Elsevier in European Journal of Radiology
- Vol. 81 (7) , 1508-1513
Artificial Neural Networks for differential diagnosis of breast lesions in MR-Mammography: A systematic approach addressing the influence of network architecture on diagnostic performance using a large clinical database
- Open Access
- 4 November 2008
- Published by Springer Nature in Cases Journal
- Vol. 1 (1) , 296
Incomplete paresis of the sciatic nerve due to massive atypical lipoma of the pelvis: a case report
Liposarcomas are classified into four subtypes, with different malignancy potential and characteristic imaging appearances. Well-differentiated liposarcomas have imaging characteristics similar to those of benign lipomas, however they can be usually distinguished from lipomas because of the larger size and broader fibrous septa, with a more nodular appearance. This paper presents a case of atypical lipoma (well-differentiated liposarcoma) of the pelvis, leading to partial involvement of the sciatic nerve. In our case, computed tomography (CT) showed a low-density lesion. In magnetic resonance imaging (MRI), T1 and T2-weighted sequences revealed a fatty appearance with signal loss on fat saturation pulse sequences. The lesion was successfully resected and no other similar lesions have been found within one year of follow-up.
- 4 November 2008
- Published by Springer Nature in Cases Journal
- Vol. 1 (1) , 296
Open AccessIncomplete paresis of the sciatic nerve due to massive atypical lipoma of the pelvis: a case report
Liposarcomas are classified into four subtypes, with different malignancy potential and characteristic imaging appearances. Well-differentiated liposarcomas have imaging characteristics similar to those of benign lipomas, however they can be usually distinguished from lipomas because of the larger size and broader fibrous septa, with a more nodular appearance. This paper presents a case of atypical lipoma (well-differentiated liposarcoma) of the pelvis, leading to partial involvement of the sciatic nerve. In our case, computed tomography (CT) showed a low-density lesion. In magnetic resonance imaging (MRI), T1 and T2-weighted sequences revealed a fatty appearance with signal loss on fat saturation pulse sequences. The lesion was successfully resected and no other similar lesions have been found within one year of follow-up.
- 24 January 2008
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 27 (2) , 347-355
MRI‐guided interventions of the breast
MRI has proven to be a very reliable diagnostic tool in the detection and differential diagnosis of breast lesions. Some lesions are, even in retrospect, not detectable in x‐ray or ultrasound images but MRI is able to detect lesions at a much smaller size than the average size of lesions depicted by x‐ray and ultrasound. The aim in the future is to develop combined procedures where imaging, biopsy, and interventional therapies are combined in a single outpatient procedure. As a step toward this goal different interventional procedures are useful that include interstitial laser therapy (ILT), radiofrequency ablation (RFA), high‐intensity focused ultrasound (HIFU), microwave ablation therapy, and cryotherapy. In this overview the main features and initial results of these procedures are described and discussed. J. Magn. Reson. Imaging 2008;27:347–355.
- 24 January 2008
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 27 (2) , 347-355
MRI‐guided interventions of the breast
MRI has proven to be a very reliable diagnostic tool in the detection and differential diagnosis of breast lesions. Some lesions are, even in retrospect, not detectable in x‐ray or ultrasound images but MRI is able to detect lesions at a much smaller size than the average size of lesions depicted by x‐ray and ultrasound. The aim in the future is to develop combined procedures where imaging, biopsy, and interventional therapies are combined in a single outpatient procedure. As a step toward this goal different interventional procedures are useful that include interstitial laser therapy (ILT), radiofrequency ablation (RFA), high‐intensity focused ultrasound (HIFU), microwave ablation therapy, and cryotherapy. In this overview the main features and initial results of these procedures are described and discussed. J. Magn. Reson. Imaging 2008;27:347–355.
- 1 October 2007
- Published by Elsevier in Seminars in Roentgenology
- Vol. 42 (4) , 228-235
Breast Magnetic Resonance Imaging: Principles and Techniques
- 1 October 2007
- Published by Elsevier in Seminars in Roentgenology
- Vol. 42 (4) , 228-235
Breast Magnetic Resonance Imaging: Principles and Techniques
- 1 August 2006
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 187 (2) , W147-W151
The Adjacent Vessel on Dynamic Contrast-Enhanced Breast MRI
OBJECTIVE. The purpose of this study was to investigate whether an adjacent vessel leading to an enhancing lesion seen on subtraction images can help differentiate malignant from benign breast lesions and therefore increase the specificity of breast MRI. MATERIALS AND METHODS. The study included 132 histologically verified lesions (71 malignant lesions, 10 pure carcinoma in situ, and 51 benign lesions) enhancing on dynamic breast MRI before biopsy. The lesions were evaluated by three radiologists in a double-blinded manner. The presence of an adjacent vessel was supposed if at least two observers voted positively. RESULTS. Sixty-one (85.9%) of 71 malignant lesions, six (60%) of 10 carcinomas in situ, and 10 (19.6%) of 51 benign lesions were associated with an adjacent vessel, which differed significantly (p < 0.001) between benign and malignant lesions (the latter with and without including pure carcinoma in situ), leading to a positive predictive value of 85.9% (87% including pure carcinomas in situ), a negative predictive value of 80.4% (74.5% including pure carcinomas in situ), an accuracy of 83.2% (81.6% including pure carcinomas in situ), a sensitivity of 85.9% (82.7% including carcinomas in situ), and a specificity of 80.4% for this sign concerning malignancy. CONCLUSION. The presence of an adjacent vessel seen on subtraction images promises to be a good marker for malignancy and can therefore help increase the specificity of breast MRI.
- 1 August 2006
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 187 (2) , W147-W151
The Adjacent Vessel on Dynamic Contrast-Enhanced Breast MRI
OBJECTIVE. The purpose of this study was to investigate whether an adjacent vessel leading to an enhancing lesion seen on subtraction images can help differentiate malignant from benign breast lesions and therefore increase the specificity of breast MRI. MATERIALS AND METHODS. The study included 132 histologically verified lesions (71 malignant lesions, 10 pure carcinoma in situ, and 51 benign lesions) enhancing on dynamic breast MRI before biopsy. The lesions were evaluated by three radiologists in a double-blinded manner. The presence of an adjacent vessel was supposed if at least two observers voted positively. RESULTS. Sixty-one (85.9%) of 71 malignant lesions, six (60%) of 10 carcinomas in situ, and 10 (19.6%) of 51 benign lesions were associated with an adjacent vessel, which differed significantly (p < 0.001) between benign and malignant lesions (the latter with and without including pure carcinoma in situ), leading to a positive predictive value of 85.9% (87% including pure carcinomas in situ), a negative predictive value of 80.4% (74.5% including pure carcinomas in situ), an accuracy of 83.2% (81.6% including pure carcinomas in situ), a sensitivity of 85.9% (82.7% including carcinomas in situ), and a specificity of 80.4% for this sign concerning malignancy. CONCLUSION. The presence of an adjacent vessel seen on subtraction images promises to be a good marker for malignancy and can therefore help increase the specificity of breast MRI.
- Open Access
- 19 March 2003
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 17 (4) , 493-498
A manipulator system for 14-gauge large core breast biopsies inside a high-field whole-body MR scanner
- 19 March 2003
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 17 (4) , 493-498
Open AccessA manipulator system for 14-gauge large core breast biopsies inside a high-field whole-body MR scanner
- 1 January 2003
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 13 (3) , 198-202
Interventionelle MR-Mammographie: Manipulatorgestützte Biopsie und interstitielle Lasertherapie von Tumoren der weiblichen Brust
- 1 January 2003
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 13 (3) , 198-202
Interventionelle MR-Mammographie: Manipulatorgestützte Biopsie und interstitielle Lasertherapie von Tumoren der weiblichen Brust
- 1 August 2000
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 35 (8) , 513-519
Robotic System for Biopsy and Therapy of Breast Lesions in a High-Field Whole-Body Magnetic Resonance Tomography Unit
Kaiser WA, Fischer H, Vagner J, Selig M. Robotic system for biopsy and therapy of breast lesions in a high-field whole-body magnetic resonance tomography unit. Invest Radiol 2000;35:513–519. With magnetic resonance mammography, significant progress has been achieved in the diagnosis of small breast cancers. However, biopsy and therapy of suspicious lesions must take place at a later time. Diagnosis and simultaneous biopsy and therapy in one single examination would considerably reduce costs, strain on the patient, and side effects. ROBITOM (Robotic system for biopsy and interventional therapy of mammary lesions) is used to approach a lesion found in the breast in an image-controlled manner under a high magnetic field (eg, 1.5 T). The robotic system works in the direct vicinity of the isocenter of a magnet and consists of a trocar, coaxial sleeve, biopsy needle, laser applicator, and a control and driving unit. It contains a rack, a driving unit along the three coaxes of space, and a gripping unit for instruments or biopsy sample removal. The system has six degrees of freedom. In vitro experiments in pig liver including eight targets (vitamin E capsules, 4 mm in diameter) were performed. All eight capsules were hit precisely by the robotic biopsy system. The procedure was performed directly in the isocenter of a 1.5-T whole-body scanner. The system allows the coordinates of a lesion in the breast to be approached in a high magnetic field without shifting the patient. A combination of imaging with biopsy and subsequent therapy (eg, laser therapy or cryotherapy) seems to be feasible in the future.
- 1 August 2000
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 35 (8) , 513-519
Robotic System for Biopsy and Therapy of Breast Lesions in a High-Field Whole-Body Magnetic Resonance Tomography Unit
Kaiser WA, Fischer H, Vagner J, Selig M. Robotic system for biopsy and therapy of breast lesions in a high-field whole-body magnetic resonance tomography unit. Invest Radiol 2000;35:513–519. With magnetic resonance mammography, significant progress has been achieved in the diagnosis of small breast cancers. However, biopsy and therapy of suspicious lesions must take place at a later time. Diagnosis and simultaneous biopsy and therapy in one single examination would considerably reduce costs, strain on the patient, and side effects. ROBITOM (Robotic system for biopsy and interventional therapy of mammary lesions) is used to approach a lesion found in the breast in an image-controlled manner under a high magnetic field (eg, 1.5 T). The robotic system works in the direct vicinity of the isocenter of a magnet and consists of a trocar, coaxial sleeve, biopsy needle, laser applicator, and a control and driving unit. It contains a rack, a driving unit along the three coaxes of space, and a gripping unit for instruments or biopsy sample removal. The system has six degrees of freedom. In vitro experiments in pig liver including eight targets (vitamin E capsules, 4 mm in diameter) were performed. All eight capsules were hit precisely by the robotic biopsy system. The procedure was performed directly in the isocenter of a 1.5-T whole-body scanner. The system allows the coordinates of a lesion in the breast to be approached in a high magnetic field without shifting the patient. A combination of imaging with biopsy and subsequent therapy (eg, laser therapy or cryotherapy) seems to be feasible in the future.