CJCarl Jones

Carl Jones

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Carl Jones has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Larger polyethylene glenospheres in reverse shoulder arthroplasty: are they safe?

    by Carl W. Jones, Matthew Barrett, John Erickson, Idah Chatindiara, Peter Poon


  • Open Access

    The Dislocated Hip Hemiarthroplasty: Current Concepts of Etiological factors and Management

    by Carl Jones, Nikolai Briffa, Joshua Jacob, Richard Hargrove

    Background: Hip hemiarthroplasty (HA) following an intracapsular neck of femur fracture is an increasingly common procedure as a result of an ageing population. Patients are often frail and so morbidity and mortality figures are significant. As a result the National Institute for Health and Clinical Excellence (NICE) has formulated guidelines and a Best Practice Tariff (BPT) in an attempt to improve the care of such patients. Dislocation following HA is a potentially devastating complication with a reported incidence ranging from 1 to 15%. Multiple causative factors have been cited and studied in an effort to reduce the incidence of this complication which has a high rate of recurrence following the first episode and is associated with a high mortality rate and significant financial burden on the health economy. This paper reviews the available literature in an effort to identify the most pertinent factors affecting dislocation rates and thus reduce the incidence of this serious complication.Methods: A comprehensive review of the literature was performed using the search engine PubMed with the keywords ‘hip’, ‘hemiarthroplasty’ and ‘dislocation’. Two hundred and forty three articles were identified and assessed by the 3 authors independently. Data from fifty-two articles pertinent to the review on hemiarthroplasty dislocation epidemiology, risk factors and management were extracted in a standardised fashion.Results: Following review of the papers multiple causative factors relating to HA dislocation were identified and grouped into 4 broad categories for analysis. The factors with the strongest correlation with dislocation included patient cognition, previous failed surgery, delay to surgery, surgical approach and femoral offset.Conclusion: Hip hemiarthroplasty remains the gold standard for elderly patients with intracapsular neck of femur fractures. In each individual case the factors most strongly associated with postoperative dislocation should be recognised. Delays to surgery should be minimised and the posterior approach avoided. In addition to good surgical technique, particular attention should be paid to restoring the patient’s native femoral offset and post operatively those with cognitive impairment should be closely monitored.


  • Open Access

    The management of paediatric diaphyseal femoral fractures: a modern approach

    by Al-Achraf Khoriati, Carl Jones, Yael Gelfer, Alex Trompeter

    The definitive treatment of paediatric femoral diaphyseal fractures remains controversial. Modalities of treatment vary mostly according to age, with fracture pattern and site having a lesser impact. Current evidence is reflective of this variation with most evidence cited by the American Academy of Orthopedic Surgeons being level 4 or 5. The authors present a review of the most up-to-date evidence relating to the treatment of these fractures in each age group. In an attempt to clarify the current trends, we have produced an algorithm for decision-making based on the experience from our own tertiary referral level 1 major trauma centre.


  • The variability in the external rotation axis of the distal femur: an MRI-based anatomical study

    by Carl Jones, Zuhair Nawaz, Abdel Hassan, Simon White, Arshad Khaleel

    Commonly used total knee arthroplasty (TKA) systems utilising measured resection techniques default to 5°–7° valgus for the distal cut relative to the anatomical axis and 3° external rotation of the femoral component relative to posterior condylar axis (PCA). Rotational errors of the femoral component are associated with pain, patella maltracking and a poorer outcome. We analysed MRI scans from patients undergoing TKA using patient-specific instrumentation to assess coronal and rotational alignment from landmarks identified on the scans. One hundred and eight scans in 59 males and 49 females were studied with age range 35–93 years (mean 67.9 years). We found 91 % of patients had a femoral valgus angle between 5° and 7° (mean angles 5.9°), while only 24 % had an external rotation angle between 2.5° and 3.5° relative to PCA. There was no statistical significance in rotation between males and females although outliers tended to be female. Mean Whiteside’s angle was 92.9° (87.8–98). This study highlights the variations in external rotation between patients undergoing TKA using the PCA as a reference for rotation. This may be a contributing factor in implant malalignment and patient dissatisfaction.


  • Open Access

    An anomalous bifid distal ulna

    by C. Jones, H. Li, N. Ellahee

    INTRODUCTION: We report a case of an osteochondroma in the form of an anomalous bifid distal ulna following mal-union of an epiphyseal injury. There has been no previous case of this reported in the medical literature. PRESENTATION OF CASE: A 19-year-old man presented with wrist stiffness and complete loss of pronation and supination twelve months after having undergone open reduction and internal fixation for a volarly displaced distal radius fracture. Further investigation with a CT scan showed a bifid distal ulna. As this was not present on plain radiographs one year prior, it was proposed that this was an osteochrondromatous growth caused by injury to the distal ulnar epiphysis. An operation was performed to excise one of the distal ulna heads, and reconstruct the TFCC to allow improved rotational movements. At one year follow-up, the patient has made an almost full recovery without complication. DISCUSSION: We postulate that the patient sustained an occult physeal injury resulting in an osteochondromatous lesion that grew towards the joint effectively forming a second ulna head. CONCLUSION: This is a unique case of the development of a bifid distal ulna due to physeal injury one year prior. Such a lesion has not previously been described in the distal ulna.


  • Open Access

    A ganglion cyst at the elbow causing superficial radial nerve compression: a case report

    by John McFarlane, Ravi Trehan, Miguel Oliveira, Carl Jones, Simon Blease, Paul Davey

    We report a rare case of a ganglion cyst at the elbow causing neurological symptoms by stretching the superficial radial nerve alone. Ganglia associated with radial nerve palsy at the elbow have been reported previously involving the deep branch of the posterior interosseous nerve and the superficial radial nerve, but not the superficial radial nerve alone.