CBChris Beltran

Chris Beltran

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Chris Beltran has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Image quality of an investigational imaging panel for use with the imaging beam line cone‐beam CT

    by Chris Beltran

    The purpose of this study was to measure and compare the contrast‐to‐noise ratio (CNR) as a function of dose for the cone‐beam CT (CBCT) produced by the imaging beam line (IBL) for the standard and an investigational imaging panel. Two Siemens Artiste linear accelerators were modified at our institution such that the MV‐CBCT would operate under an investigational IBL. The imaging panel from one of the machines was replaced with an investigational imaging panel. After the modification, a set of CBCT for a large and small phantom consisting of eight tissue‐equivalent inserts was acquired for the standard imager and for the investigational imager with and without the standard copper plate. Ten dose settings for each phantom using the IBL in combination with the standard and investigational imaging panel were acquired. The CNR for each tissue‐equivalent insert was calculated. Resolution measurements in line pairs per mm (lp/mm) of the CBCT for the various imaging panel setups were made. In addition, CBCT images of two patients that were imaged with each panel configuration were displayed for a group of physicians and therapists who were asked to identify the best and worst CBCT for each patient. This was used as a qualitative judge of practical image quality. The CNR of the muscle insert for the large phantom with 1.5 cGy at isocenter was 1.3 for the standard imager, 1.5 for the investigational imager with the copper plate, and 1.9 without the plate. Under the same conditions, the CNR of the trabecular bone insert was 5.9, 7.3, and 9.7, respectively. For the small phantom with the same dose to isocenter, the CNR for muscle was 1.7, 2.1, and 3.3, respectively. For the trabecular bone, the CNR was 8.1, 9.6, and 12.1 respectively. The resolution for 1 cGy at isocenter was 0.37 lp/mm for the standard imager, 0.32 and 0.33 for the investigational imager with and without the copper plate. The qualitative test ranked the CBCT of the investigational imager without the copper plate to be the best image, and the standard imager to be the worst. The investigational imaging panel improves image quality as compared to the standard imager for IBL CBCTs. A 1 cGy IBL CBCT, no matter which imager is used, is sufficient for bony anatomy localization. The investigational imager without the copper plate was judged clinically to produce the best IBL CBCT. PACS numbers: 87.57.Q, 87.57.cj


  • Open Access

    Dependence of intrafraction motion on fraction duration for pediatric patients with brain tumors

    by Chris Beltran, Thomas E. Merchant

    The purpose of this study was to quantify the intrafraction motion of pediatric patients with brain tumors during radiation therapy and investigate any correlation between motion, use of general anesthesia, and daily treatment duration. 100 pediatric patients with a mean age of 8.5 years (range: 1.0 to 17.8) were included in this prospective study. Forty-one patients required general anesthesia during treatment, mean age 4.8 years; 59 patients did not, mean age 11.2 years. Each patient had an intracranial tumor and was treated in the supine position with a thermoplastic facemask and headrest for immobilization. A pretreatment localization CBCT was acquired for each treatment fraction and a post-treatment CBCT was acquired every other fraction. If the magnitude of the patient's position pre-CBCT offset was >= 2 mm, the position was corrected. The difference between the patient's position based on the post-CBCT and the assumed position at the start of treatment (either the pre-CBCT offset if the magnitude was < 2 mm, or 0 offset due to correction) was determined and labeled intrafraction motion. Correlations between daily treatment duration and intrafraction motion were examined. There was an average of 14.2 post-CBCTs acquired per patient. The magnitude of the mean intrafraction motion was 1.2 +/- 0.8 mm for patients requiring general anesthesia, and 1.5 +/- 1.2 mm for those without (p < 0.001). The mean offset in each direction was less than 0.5 mm for both cohorts. There was no correlation between daily treatment duration and the magnitude of intrafraction motion. The intrafraction motion of pediatric patients undergoing external beam therapy for intracranial tumors is small, < 2 mm, and is independent of the daily treatment duration.


  • Open Access

    Role of adaptive radiation therapy for pediatric patients with diffuse pontine glioma

    by Chris Beltran, Saumya Sharma, Thomas E. Merchant

    We investigate the role of adaptive radiation therapy in pediatric patients with diffuse pontine glioma and the impact of steroid-related weight gain on treatment parameters utilizing cone-beam CT. Fifteen patients with diffuse pontine glioma were treated with three-dimensional conformal radiation therapy and enrolled on a daily localization protocol. The median age was 6 years (range: 2–13 years). Patient charts were examined to obtain the prescribed daily dose of dexamethasone and weight. The original treatment plan was recalculated based on the data obtained from the daily cone-beam CT. The changes in target and critical structure doses were calculated using gEUD. Correlations between prescribed dexamethasone, weight gain, source-to-skin distance (SSD) changes and dosimetric changes were investigated. Eleven of the 15 patients gained weight during radiation therapy, with an average gain of 2.2 kg (8.0%). The mean gEUD decreased was 0.57 Gy (range: 0.24–1.4 Gy) for the PTV, and the mean gEUD increase for critical structures was 1.14%. No strong correlations between prescribed dexamethasone doses, weight gain and dosimetric changes were found. Change in SSD vs. dose to PTV was correlated (R2=0.51) . Weight gain and changes to the external surface are apparent in these patients; however, the dosimetric changes to the target and critical structures were small and in most cases did not warrant an adaptive plan. The potential exists for a decrease in target dose in these patients; therefore, they should be monitored to assess for replanning when necessary. PACS number: 87.53Jw


    • 30 January 2011
      • Vol. 12  (2) , 3421

    Role of adaptive radiation therapy for pediatric patients with diffuse pontine glioma.

    by Chris Beltran, Saumya Sharma, Thomas E Merchant

    We investigate the role of adaptive radiation therapy in pediatric patients with diffuse pontine glioma and the impact of steroid-related weight gain on treatment parameters utilizing cone-beam CT. Fifteen patients with diffuse pontine glioma were treated with three-dimensional conformal radiation therapy and enrolled on a daily localization protocol. The median age was 6 years (range: 2-13 years). Patient charts were examined to obtain the prescribed daily dose of dexamethasone and weight. The original treatment plan was recalculated based on the data obtained from the daily cone-beam CT. The changes in target and critical structure doses were calculated using gEUD. Correlations between prescribed dexamethasone, weight gain, source-to-skin distance (SSD) changes and dosimetric changes were investigated. Eleven of the 15 patients gained weight during radiation therapy, with an average gain of 2.2 kg (8.0%). The mean gEUD decreased was 0.57 Gy (range: 0.24-1.4 Gy) for the PTV, and the mean gEUD increase for critical structures was 1.14%. No strong correlations between prescribed dexamethasone doses, weight gain and dosimetric changes were found. Change in SSD vs. dose to PTV was correlated (R² = 0.51). Weight gain and changes to the external surface are apparent in these patients; however, the dosimetric changes to the target and critical structures were small and in most cases did not warrant an adaptive plan. The potential exists for a decrease in target dose in these patients; therefore, they should be monitored to assess for replanning when necessary.


  • Open Access

    Daily image‐guided localization for neuroblastoma

    by Chris Beltran, Atmaram S. Pai Panandiker, Matthew J. Krasin, Thomas E. Merchant

    The purpose was to quantify the setup margin for pediatric patients with neuroblastoma using cone beam CT imaging (CBCT) and ultrasound localization. Ten patients, with a median age of 4.3 years (1.8 to 7.9) underwent daily pretreatment localization CBCT and every other day post‐treatment CBCT to calculate interfractional and intrafraction movement. Localization was based on CBCT to treatment planning CT registration in the lumbar spine region. Each subject was treated in the supine position under IV general anesthesia using intensity‐modulated radiation therapy. Patients were repositioned based on the daily pretreatment CBCT. Required setup margins based on inter‐ and intrafraction positioning errors were calculated based on weekly and daily imaging scenarios. Four patients had ultrasound localization of the kidneys performed before the CBCT. Correlation between daily CBCT and ultrasound was investigated. A lateral, longitudinal and vertical setup margin of 5.4, 5.6, and 5.9 mm is required without daily CBCT. When daily CBCT was incorporated, the setup margin was reduced to 1.5, 2.1, and 1.7 mm. There was no correlation between the suggested ultrasound shifts and the shifts based on the CBCT. Daily localization based on CBCT of the lumbar spine can reduce the required setup margin for neuroblastoma patients, thereby reducing normal tissue exposure for this young patient population. The internal margin needs further investigation before PTV reduction can be made. Ultrasound localization was highly variable and not correlated to CBCT shifts.PACS number: 87.53.Jw