Brian L. Davis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Brian L. Davis has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Metin Yavuz
Ohio College of Podiatric Medicine, Independence, OH 44131, USA
4 shared publicationsGeorgeanne Botek
C Department of Orthopedic Surgery, Cleveland Clinic, Cleveland, OH 44195, USA
3 shared publicationsAhmet Erdemir
Biomedical Engineering, Cleveland Clinic, Cleveland, Ohio
1 shared publication- Antonie J. van Den Bogert
Cleveland State University
1 shared publication Azita Tajaddini
A Department of Biomedical Engineering, Cleveland Clinic, Cleveland, OH 44195, USA
1 shared publicationDong Gil Lee
Lerner Research Institute, Department of Biomedical Engineering, Cleveland, OH 44195, USA
1 shared publication
Latest Publications
- 28 January 2010
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 132 (2) , 025001
Design and Validation of a General Purpose Robotic Testing System for Musculoskeletal Applications
Orthopaedic research on in vitro forces applied to bones, tendons, and ligaments during joint loading has been difficult to perform because of limitations with existing robotic simulators in applying full-physiological loading to the joint under investigation in real time. The objectives of the current work are as follows: (1) describe the design of a musculoskeletal simulator developed to support in vitro testing of cadaveric joint systems, (2) provide component and system-level validation results, and (3) demonstrate the simulator’s usefulness for specific applications of the foot-ankle complex and knee. The musculoskeletal simulator allows researchers to simulate a variety of loading conditions on cadaver joints via motorized actuators that simulate muscle forces while simultaneously contacting the joint with an external load applied by a specialized robot. Multiple foot and knee studies have been completed at the Cleveland Clinic to demonstrate the simulator’s capabilities. Using a variety of general-use components, experiments can be designed to test other musculoskeletal joints as well (e.g., hip, shoulder, facet joints of the spine). The accuracy of the tendon actuators to generate a target force profile during simulated walking was found to be highly variable and dependent on stance position. Repeatability (the ability of the system to generate the same tendon forces when the same experimental conditions are repeated) results showed that repeat forces were within the measurement accuracy of the system. It was determined that synchronization system accuracy was and was based on timing measurements from the robot and tendon actuators. The positioning error of the robot ranged from to , depending on measurement condition (e.g., loaded or unloaded, quasistatic or dynamic motion, centralized movements or extremes of travel, maximum value, or root-mean-square, and -, - or -axis motion). Algorithms and methods for controlling specimen interactions with the robot (with and without muscle forces) to duplicate physiological loading of the joints through iterative pseudo-fuzzy logic and real-time hybrid control are described. Results from the tests of the musculoskeletal simulator have demonstrated that the speed and accuracy of the components, the synchronization timing, the force and position control methods, and the system software can adequately replicate the biomechanics of human motion required to conduct meaningful cadaveric joint investigations.- 28 January 2010
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 132 (2) , 025001
Design and Validation of a General Purpose Robotic Testing System for Musculoskeletal Applications
Orthopaedic research on in vitro forces applied to bones, tendons, and ligaments during joint loading has been difficult to perform because of limitations with existing robotic simulators in applying full-physiological loading to the joint under investigation in real time. The objectives of the current work are as follows: (1) describe the design of a musculoskeletal simulator developed to support in vitro testing of cadaveric joint systems, (2) provide component and system-level validation results, and (3) demonstrate the simulator’s usefulness for specific applications of the foot-ankle complex and knee. The musculoskeletal simulator allows researchers to simulate a variety of loading conditions on cadaver joints via motorized actuators that simulate muscle forces while simultaneously contacting the joint with an external load applied by a specialized robot. Multiple foot and knee studies have been completed at the Cleveland Clinic to demonstrate the simulator’s capabilities. Using a variety of general-use components, experiments can be designed to test other musculoskeletal joints as well (e.g., hip, shoulder, facet joints of the spine). The accuracy of the tendon actuators to generate a target force profile during simulated walking was found to be highly variable and dependent on stance position. Repeatability (the ability of the system to generate the same tendon forces when the same experimental conditions are repeated) results showed that repeat forces were within the measurement accuracy of the system. It was determined that synchronization system accuracy was and was based on timing measurements from the robot and tendon actuators. The positioning error of the robot ranged from to , depending on measurement condition (e.g., loaded or unloaded, quasistatic or dynamic motion, centralized movements or extremes of travel, maximum value, or root-mean-square, and -, - or -axis motion). Algorithms and methods for controlling specimen interactions with the robot (with and without muscle forces) to duplicate physiological loading of the joints through iterative pseudo-fuzzy logic and real-time hybrid control are described. Results from the tests of the musculoskeletal simulator have demonstrated that the speed and accuracy of the components, the synchronization timing, the force and position control methods, and the system software can adequately replicate the biomechanics of human motion required to conduct meaningful cadaveric joint investigations.- 6 August 2009
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 131 (9) , 091007
Prediction of Plantar Shear Stress Distribution by Artificial Intelligence Methods
Shear forces under the human foot are thought to be responsible for various foot pathologies such as diabetic plantar ulcers and athletic blisters. Frictional shear forces might also play a role in the metatarsalgia observed among hallux valgus (HaV) and rheumatoid arthritis (RA) patients. Due to the absence of commercial devices capable of measuring shear stress distribution, a number of linear models were developed. All of these have met with limited success. This study used nonlinear methods, specifically neural network and fuzzy logic schemes, to predict the distribution of plantar shear forces based on vertical loading parameters. In total, 73 subjects were recruited; 17 had diabetic neuropathy, 14 had HaV, 9 had RA, 11 had frequent foot blisters, and 22 were healthy. A feed-forward neural network (NN) and adaptive neurofuzzy inference system (NFIS) were built. These systems were then applied to a custom-built platform, which collected plantar pressure and shear stress data as subjects walked over the device. The inputs to both models were peak pressure, peak pressure-time integral, and time to peak pressure, and the output was peak resultant shear. Root-mean-square error (RMSE) values were calculated to test the models’ accuracy. RMSE/actual shear ratio varied between 0.27 and 0.40 for NN predictions. Similarly, NFIS estimations resulted in a 0.28–0.37 ratio for local peak values in all subject groups. On the other hand, error percentages for global peak shear values were found to be in the range 11.4–44.1. These results indicate that there is no direct relationship between pressure and shear magnitudes. Future research should aim to decrease error levels by introducing shear stress dependent variables into the models.
- 6 August 2009
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 131 (9) , 091007
Prediction of Plantar Shear Stress Distribution by Artificial Intelligence Methods
Shear forces under the human foot are thought to be responsible for various foot pathologies such as diabetic plantar ulcers and athletic blisters. Frictional shear forces might also play a role in the metatarsalgia observed among hallux valgus (HaV) and rheumatoid arthritis (RA) patients. Due to the absence of commercial devices capable of measuring shear stress distribution, a number of linear models were developed. All of these have met with limited success. This study used nonlinear methods, specifically neural network and fuzzy logic schemes, to predict the distribution of plantar shear forces based on vertical loading parameters. In total, 73 subjects were recruited; 17 had diabetic neuropathy, 14 had HaV, 9 had RA, 11 had frequent foot blisters, and 22 were healthy. A feed-forward neural network (NN) and adaptive neurofuzzy inference system (NFIS) were built. These systems were then applied to a custom-built platform, which collected plantar pressure and shear stress data as subjects walked over the device. The inputs to both models were peak pressure, peak pressure-time integral, and time to peak pressure, and the output was peak resultant shear. Root-mean-square error (RMSE) values were calculated to test the models’ accuracy. RMSE/actual shear ratio varied between 0.27 and 0.40 for NN predictions. Similarly, NFIS estimations resulted in a 0.28–0.37 ratio for local peak values in all subject groups. On the other hand, error percentages for global peak shear values were found to be in the range 11.4–44.1. These results indicate that there is no direct relationship between pressure and shear magnitudes. Future research should aim to decrease error levels by introducing shear stress dependent variables into the models.
- 1 August 2009
- Published by SAGE Publications in Foot & Ankle International
- Vol. 30 (8) , 767-772
Assessment of the Effects of Diabetes on Midfoot Joint Pressures Using a Robotic Gait Simulator
Background: One of the more serious diabetic complications is Charcot neuroarthropathy (CN), a disease that results in arch collapse and permanent foot deformity. However, very little is known about the etiology of CN. From a mechanical standpoint, it is likely that there is a “vicious circle” in terms of (i) arch collapse causing increased midfoot joint pressures, and (ii) increased joint contact pressures exacerbating the collapse of midfoot bones. This study focused on assessment of peak joint pressure difference between diabetic and non-diabetic cadaver feet during simulated walking. We hypothesized that joint pressures are higher for diabetics than normal population. Materials and Methods: Sixteen cadaver foot specimens (eight control and eight diabetic specimens) were used in this study. Human gait at 25% of typical walking speed (averaged stance duration of 3.2s) was simulated by a custom-designed Universal Musculoskeletal Simulator. Four medial midfoot joint pressures (the first metatarsocuneiform, the medial naviculocuneiform, the middle naviculocuneiform, and the first intercuneiform) were measured dynamically during full stance. Results: The pressures in each of the four measured midfoot joints were significantly greater in the diabetic feet ( p = 0.015, p = 0.025, p < 0.001, and p = 0.545, respectively). Conclusion: Across all four tested joints, the diabetic cadaver specimens had, on average, 46% higher peak pressures than the control cadaver feet during the simulated stance phase. Clinical Relevance: This finding suggests that diabetic patients could be predisposed to arch collapse even before there are visible signs of bone or joint abnormalities.
- 1 August 2009
- Published by SAGE Publications in Foot & Ankle International
- Vol. 30 (8) , 767-772
Assessment of the Effects of Diabetes on Midfoot Joint Pressures Using a Robotic Gait Simulator
Background: One of the more serious diabetic complications is Charcot neuroarthropathy (CN), a disease that results in arch collapse and permanent foot deformity. However, very little is known about the etiology of CN. From a mechanical standpoint, it is likely that there is a “vicious circle” in terms of (i) arch collapse causing increased midfoot joint pressures, and (ii) increased joint contact pressures exacerbating the collapse of midfoot bones. This study focused on assessment of peak joint pressure difference between diabetic and non-diabetic cadaver feet during simulated walking. We hypothesized that joint pressures are higher for diabetics than normal population. Materials and Methods: Sixteen cadaver foot specimens (eight control and eight diabetic specimens) were used in this study. Human gait at 25% of typical walking speed (averaged stance duration of 3.2s) was simulated by a custom-designed Universal Musculoskeletal Simulator. Four medial midfoot joint pressures (the first metatarsocuneiform, the medial naviculocuneiform, the middle naviculocuneiform, and the first intercuneiform) were measured dynamically during full stance. Results: The pressures in each of the four measured midfoot joints were significantly greater in the diabetic feet ( p = 0.015, p = 0.025, p < 0.001, and p = 0.545, respectively). Conclusion: Across all four tested joints, the diabetic cadaver specimens had, on average, 46% higher peak pressures than the control cadaver feet during the simulated stance phase. Clinical Relevance: This finding suggests that diabetic patients could be predisposed to arch collapse even before there are visible signs of bone or joint abnormalities.
- 1 January 2008
- Published by Elsevier in Journal of Biomechanics
- Vol. 41 (3) , 556-559
Temporal characteristics of plantar shear distribution: Relevance to diabetic patients
- 1 January 2008
- Published by Elsevier in Journal of Biomechanics
- Vol. 41 (3) , 556-559
Temporal characteristics of plantar shear distribution: Relevance to diabetic patients
- Open Access
- 1 October 2007
- Published by American Diabetes Association in Diabetes Care
- Vol. 30 (10) , 2643-2645
Peak Plantar Pressure and Shear Locations
- 1 October 2007
- Published by American Diabetes Association in Diabetes Care
- Vol. 30 (10) , 2643-2645
Open AccessPeak Plantar Pressure and Shear Locations
- 1 January 2007
- Published by Elsevier in Journal of Biomechanics
- Vol. 40 (13) , 3045-3049
Plantar shear stress distributions: Comparing actual and predicted frictional forces at the foot–ground interface
- 1 January 2007
- Published by Elsevier in Journal of Biomechanics
- Vol. 40 (13) , 3045-3049
Plantar shear stress distributions: Comparing actual and predicted frictional forces at the foot–ground interface