Kausik Sarkar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kausik Sarkar has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Amit Katiyar
Mech. Eng., Univ. of Delaware, Newark, DE 19716
6 shared publications Amit Katiyar
Department of Mechanical Engineering, University of Delaware, 130 Academy Street, Newark, Delaware 19701, USA
4 shared publicationsPankaj Jain
3 shared publicationsFlemming Forsberg
Department of Radiology, Thomas Jefferson University , 132 South 10th Street, Philadelphia, Pennsylvania 19107
2 shared publicationsKrishna Sarker
Biological Sci., Univ. of Delaware, Newark, DE 19716
1 shared publicationNishith Aggarwal
Department of Mechanical Engineering, University of Delaware, Newark, DE-19716, USA
1 shared publication
Latest Publications
- 1 September 2012
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 132 (3_Suppleme) , 2037
Effects of encapsulation damping on frequency dependent subharmonic threshold for contrast microbubbles
- 1 September 2012
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 132 (3_Suppleme) , 2037
Effects of encapsulation damping on frequency dependent subharmonic threshold for contrast microbubbles
- 1 November 2011
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 130 (5) , 3137-3147
Excitation threshold for subharmonic generation from contrast microbubbles
Six models of contrast microbubbles are investigated to determine the excitation threshold for subharmonic generation. The models are applied to a commercial contrast agent; its characteristic parameters according to each model are determined using experimentally measured ultrasound attenuation. In contrast to the classical perturbative result, the minimum threshold for subharmonic generation is not always predicted at excitation with twice the resonance frequency; instead it occurs over a range of frequencies from resonance to twice the resonance frequency. The quantitative variation of the threshold with frequency depends on the model and the bubble radius. All models are transformed into a common interfacial rheological form, where the encapsulation is represented by two radius dependent surface properties—effective surface tension and surface dilatational viscosity. Variation of the effective surface tension with radius, specifically having an upper limit (resulting from strain softening or rupture of the encapsulation during expansion), plays a critical role. Without the upper limit, the predicted threshold is extremely large, especially near the resonance frequency. Having a lower limit on surface tension (e.g., zero surface tension in the buckled state) increases the threshold value at twice the resonance frequency, in some cases shifting the minimum threshold toward resonance.
- 1 November 2011
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 130 (5) , 3137-3147
Excitation threshold for subharmonic generation from contrast microbubbles
Six models of contrast microbubbles are investigated to determine the excitation threshold for subharmonic generation. The models are applied to a commercial contrast agent; its characteristic parameters according to each model are determined using experimentally measured ultrasound attenuation. In contrast to the classical perturbative result, the minimum threshold for subharmonic generation is not always predicted at excitation with twice the resonance frequency; instead it occurs over a range of frequencies from resonance to twice the resonance frequency. The quantitative variation of the threshold with frequency depends on the model and the bubble radius. All models are transformed into a common interfacial rheological form, where the encapsulation is represented by two radius dependent surface properties—effective surface tension and surface dilatational viscosity. Variation of the effective surface tension with radius, specifically having an upper limit (resulting from strain softening or rupture of the encapsulation during expansion), plays a critical role. Without the upper limit, the predicted threshold is extremely large, especially near the resonance frequency. Having a lower limit on surface tension (e.g., zero surface tension in the buckled state) increases the threshold value at twice the resonance frequency, in some cases shifting the minimum threshold toward resonance.
- 1 October 2011
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 130 (4_Suppleme) , 2539
Inhibition of breast cancer cell proliferation by low-intensity pulsed ultrasound (LIPUS)
- 1 October 2011
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 130 (4_Suppleme) , 2539
Inhibition of breast cancer cell proliferation by low-intensity pulsed ultrasound (LIPUS)
- 1 October 2011
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 130 (4_Suppleme) , 2503
Role of effective surface tension on the frequency dependent subharmonic threshold for contrast microbubbles
- 1 October 2011
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 130 (4_Suppleme) , 2503
Role of effective surface tension on the frequency dependent subharmonic threshold for contrast microbubbles
- 19 August 2011
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 683, 149-171
Inertial effects on the dynamics, streamline topology and interfacial stresses due to a drop in shear
Deformation of a viscous drop in shear at finite inertia and the streamlines around it are numerically investigated. Inertia destroys the closed streamlines found in Stokes flow. It creates reversed streamlines and streamlines spiralling around the vorticity axis. Spiralling streamlines spiral either towards the central shear plane or away from it depending on the viscosity ratio and the inertia. The zones of open or reversed streamlines as well as streamlines spiralling towards or away from the central shear plane are delineated for varying viscosity ratio and Reynolds number. In contrast to the infinite extent of the closed Stokes streamlines around a rigid sphere in shear, the region of the spiralling streamlines in the vorticity direction both for a rigid sphere and a drop shrinks with inertia. Inertia increases deformation, and introduces oscillations in drop shape. An approximate analysis explains the scaling of oscillation frequency and damping with Reynolds and capillary numbers. The steady-state drop inclination angle with the flow axis increases with increasing Reynolds number for small Reynolds number. But it decreases at higher Reynolds number, especially for larger capillary numbers. For smaller capillary numbers, drop inclination reaches higher than $4{5}^{\ensuremath{\circ} } $ (the direction of maximum extension), critically affecting the interfacial stresses due to the drop. It changes the sign of first and second normal interfacial stress differences (and thereby these components of the effective stresses of an emulsion of such drops). Increasing viscosity ratio orients the drop towards the flow axis, which increases the critical Reynolds number above which the drop inclination reaches more than $4{5}^{\ensuremath{\circ} } $ .- 19 August 2011
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 683, 149-171
Inertial effects on the dynamics, streamline topology and interfacial stresses due to a drop in shear
Deformation of a viscous drop in shear at finite inertia and the streamlines around it are numerically investigated. Inertia destroys the closed streamlines found in Stokes flow. It creates reversed streamlines and streamlines spiralling around the vorticity axis. Spiralling streamlines spiral either towards the central shear plane or away from it depending on the viscosity ratio and the inertia. The zones of open or reversed streamlines as well as streamlines spiralling towards or away from the central shear plane are delineated for varying viscosity ratio and Reynolds number. In contrast to the infinite extent of the closed Stokes streamlines around a rigid sphere in shear, the region of the spiralling streamlines in the vorticity direction both for a rigid sphere and a drop shrinks with inertia. Inertia increases deformation, and introduces oscillations in drop shape. An approximate analysis explains the scaling of oscillation frequency and damping with Reynolds and capillary numbers. The steady-state drop inclination angle with the flow axis increases with increasing Reynolds number for small Reynolds number. But it decreases at higher Reynolds number, especially for larger capillary numbers. For smaller capillary numbers, drop inclination reaches higher than $4{5}^{\ensuremath{\circ} } $ (the direction of maximum extension), critically affecting the interfacial stresses due to the drop. It changes the sign of first and second normal interfacial stress differences (and thereby these components of the effective stresses of an emulsion of such drops). Increasing viscosity ratio orients the drop towards the flow axis, which increases the critical Reynolds number above which the drop inclination reaches more than $4{5}^{\ensuremath{\circ} } $ .- 1 April 2011
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 129 (4_Suppleme) , 2513
Subharmonic response from ultrasound contrast microbubbles for noninvasive blood pressure estimation.
- 1 April 2011
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 129 (4_Suppleme) , 2513
Subharmonic response from ultrasound contrast microbubbles for noninvasive blood pressure estimation.
- 1 April 2011
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 129 (4) , 2325-2335
Modeling subharmonic response from contrast microbubbles as a function of ambient static pressure
Variation of subharmonic response from contrast microbubbles with ambient pressure is numerically investigated for non-invasive monitoring of organ-level blood pressure. Previously, several contrast microbubbles both in vitro and in vivo registered approximately linear (5–15 dB) subharmonic response reduction with 188 mm Hg change in ambient pressure. In contrast, simulated subharmonic response from a single microbubble is seen here to either increase or decrease with ambient pressure. This is shown using the code BUBBLESIM for encapsulated microbubbles, and then the underlying dynamics is investigated using a free bubble model. The ratio of the excitation frequency to the natural frequency of the bubble is the determining parameter—increasing ambient pressure increases natural frequency thereby changing this ratio. For frequency ratio below a lower critical value, increasing ambient pressure monotonically decreases subharmonic response. Above an upper critical value of the same ratio, increasing ambient pressure increases subharmonic response; in between, the subharmonic variation is non-monotonic. The precise values of frequency ratio for these three different trends depend on bubble radius and excitation amplitude. The modeled increase or decrease of subharmonic with ambient pressure, when one happens, is approximately linear only for certain range of excitation levels. Possible reasons for discrepancies between model and previous experiments are discussed.
- 1 April 2011
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 129 (4) , 2325-2335
Modeling subharmonic response from contrast microbubbles as a function of ambient static pressure
Variation of subharmonic response from contrast microbubbles with ambient pressure is numerically investigated for non-invasive monitoring of organ-level blood pressure. Previously, several contrast microbubbles both in vitro and in vivo registered approximately linear (5–15 dB) subharmonic response reduction with 188 mm Hg change in ambient pressure. In contrast, simulated subharmonic response from a single microbubble is seen here to either increase or decrease with ambient pressure. This is shown using the code BUBBLESIM for encapsulated microbubbles, and then the underlying dynamics is investigated using a free bubble model. The ratio of the excitation frequency to the natural frequency of the bubble is the determining parameter—increasing ambient pressure increases natural frequency thereby changing this ratio. For frequency ratio below a lower critical value, increasing ambient pressure monotonically decreases subharmonic response. Above an upper critical value of the same ratio, increasing ambient pressure increases subharmonic response; in between, the subharmonic variation is non-monotonic. The precise values of frequency ratio for these three different trends depend on bubble radius and excitation amplitude. The modeled increase or decrease of subharmonic with ambient pressure, when one happens, is approximately linear only for certain range of excitation levels. Possible reasons for discrepancies between model and previous experiments are discussed.
- 1 October 2010
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 128 (4_Suppleme) , 2280
Excitation thresholds for subharmonic response of ultrasound contrast microbubbles.
Nonlinear dynamics of encapsulated contrast microbubbles generates subharmonic response at stronger acoustic excitations. The response depends on environmental conditions such as ambient pressure. It has therefore been proposed that the subharmonic response could offer a novel means for non‐invasive monitoring of organ‐level blood pressure. For a free bubble, there exists a threshold excitation pressure for subharmonic response, the threshold being minimum at twice the resonance frequency of the free bubble. The stabilizing encapsulation of a contrast microbubble significantly alters the behavior of a bubble. Several models of encapsulation have been developed and their predictions compared with measured response from contrast microbubbles. Here, we use these models to study the threshold pressure for initiation of subharmonic scattered response. We will show that the encapsulation significantly affects the threshold and the variation of subharmonic response with other parameters such as ambient pressure, excitation, and bubble radius.
- 1 October 2010
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 128 (4_Suppleme) , 2280
Excitation thresholds for subharmonic response of ultrasound contrast microbubbles.
Nonlinear dynamics of encapsulated contrast microbubbles generates subharmonic response at stronger acoustic excitations. The response depends on environmental conditions such as ambient pressure. It has therefore been proposed that the subharmonic response could offer a novel means for non‐invasive monitoring of organ‐level blood pressure. For a free bubble, there exists a threshold excitation pressure for subharmonic response, the threshold being minimum at twice the resonance frequency of the free bubble. The stabilizing encapsulation of a contrast microbubble significantly alters the behavior of a bubble. Several models of encapsulation have been developed and their predictions compared with measured response from contrast microbubbles. Here, we use these models to study the threshold pressure for initiation of subharmonic scattered response. We will show that the encapsulation significantly affects the threshold and the variation of subharmonic response with other parameters such as ambient pressure, excitation, and bubble radius.
- 1 October 2010
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 128 (4) , 2364
Effects of ultrasound on osteoblast proliferation and its mechanisms triggered by calcium transport.
Bone fracture healing is a set of complex sequential physiological processes that involves several cellular activities. FDA has approved the application of low‐intensity pulsed ultrasound for accelerated healing of fractures. However, currently the cellulareffects of ultrasound and how ultrasoundeffects healing are not completely understood. We are studying the effects of ultrasound on osteoblast cellsin vitro toward this goal. Results of cell proliferation under pulsed ultrasound excitation (0.5–5 MHz, 1–500 mW/cm2, 200 μm, 1 kHz PRF) for a duration of 5–30 min daily will be presented. BrdU and MTS assays were used for the quantification of cell proliferation. We found a significant increase in cell proliferation for the intensity variation of 1–100 mW/cm2. At higher intensities (about 500 mW/cm2) of excitation, cells die. Intracellular calcium storage and its flux through cellularmembrane are believed to play a critical role in cell response to mechanical stimuli. We will present results of cell proliferation when calcium transport through the voltage sensitive calcium channels (L‐type and T‐type) and mechano‐sensitive cation‐selective channels was blocked. Preliminary data suggest the role of T‐type calcium channel toward enhancement of cell proliferation.
- 1 October 2010
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 128 (4) , 2364
Effects of ultrasound on osteoblast proliferation and its mechanisms triggered by calcium transport.
Bone fracture healing is a set of complex sequential physiological processes that involves several cellular activities. FDA has approved the application of low‐intensity pulsed ultrasound for accelerated healing of fractures. However, currently the cellulareffects of ultrasound and how ultrasoundeffects healing are not completely understood. We are studying the effects of ultrasound on osteoblast cellsin vitro toward this goal. Results of cell proliferation under pulsed ultrasound excitation (0.5–5 MHz, 1–500 mW/cm2, 200 μm, 1 kHz PRF) for a duration of 5–30 min daily will be presented. BrdU and MTS assays were used for the quantification of cell proliferation. We found a significant increase in cell proliferation for the intensity variation of 1–100 mW/cm2. At higher intensities (about 500 mW/cm2) of excitation, cells die. Intracellular calcium storage and its flux through cellularmembrane are believed to play a critical role in cell response to mechanical stimuli. We will present results of cell proliferation when calcium transport through the voltage sensitive calcium channels (L‐type and T‐type) and mechano‐sensitive cation‐selective channels was blocked. Preliminary data suggest the role of T‐type calcium channel toward enhancement of cell proliferation.
- 1 March 2010
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 343 (1) , 42-47
Stability analysis of an encapsulated microbubble against gas diffusion
- 1 March 2010
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 343 (1) , 42-47
Stability analysis of an encapsulated microbubble against gas diffusion