Sabine F. Bensamoun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sabine F. Bensamoun has a total of 136 co-authors. Here are the top co-authors by number of shared publications:
Fabrice Charleux
ACRIM-Polyclinique Saint Côme
13 shared publications- Philippe Pouletaut
Biomécanique et Bioingénierie
10 shared publications John R. Hawse
Department of Biochemistry and Molecular Biology Mayo Clinic Rochester Minnesota USA
7 shared publicationsLudovic Robert
Radiology Unit ACRIM‐Polyclinique Saint Côme Compiègne France
7 shared publicationsMalayannan Subramaniam
Department of Biochemistry and Molecular Biology Mayo Clinic Rochester Minnesota USA
7 shared publicationsF. Charleux
6 shared publications
Latest Publications
- Open Access
- 26 August 2026
- Published by Springer Nature in European Spine Journal
- p. 1-16
Thoracolumbar fascia ultrasound and elastography biomarkers in low back pain: a systematic review of associations and responsiveness to intervention
Background and aim: Traditional imaging methods often fail to identify the causes of nonspecific low back pain (NSLBP). The thoracolumbar fascia (TLF) has gained attention as a potential target for assessment with Quantitative Ultrasound (QUS). This systematic review examines the relationships between TLF QUS biomarkers (stiffness, shear strain, morphology, and microstructure) and NSLBP and how these biomarkers respond to interventions. Methods: Adhering to PRISMA 2020 guidelines, searches were conducted in MEDLINE, EMBASE, CENTRAL, and Scopus up to February 2026 for studies evaluating TLF QUS biomarkers in adults with NSLBP. Risk of bias was assessed using RoB 2, ROBINS-I, and NOS. Due to methodological heterogeneity, a narrative synthesis was performed. Findings: Fourteen studies involving approximately 880 participants met the inclusion criteria. In chronic NSLBP, several studies reported greater TLF thickness, altered echogenicity or microstructural texture parameters, and differences in stiffness compared with asymptomatic controls. However, stiffness findings were inconsistent across elastography modalities, with both higher and lower stiffness-related measures reported. Functional mobility findings also varied by clinical population and measurement protocol: studies in acute LBP generally reported reduced deformation, whereas studies in chronic LBP reported either reduced or increased shear strain. Preliminary intervention studies indicated changes in TLF thickness and selected stiffness-related measures following manual interventions, whereas single-session massage did not produce detectable changes in shear strain measures. Interpretation: QUS studies have identified differences in TLF morphology, mechanical properties, mobility, and microstructural texture parameters between some individuals with NSLBP and asymptomatic controls. The direction and magnitude of these differences are not uniform and vary across populations, imaging modalities, and acquisition protocols. The available findings may be consistent with different patterns of fascial mechanical behavior, but the existence of distinct biological or clinically actionable TLF phenotypes remains hypothetical and requires prospective validation. Evidence regarding responsiveness to intervention is preliminary, and the clinical utility of these parameters for diagnosis, treatment selection, or outcome monitoring has not yet been established.
- 26 August 2026
- Published by Springer Nature in European Spine Journal
- p. 1-16
Open AccessThoracolumbar fascia ultrasound and elastography biomarkers in low back pain: a systematic review of associations and responsiveness to intervention
Background and aim: Traditional imaging methods often fail to identify the causes of nonspecific low back pain (NSLBP). The thoracolumbar fascia (TLF) has gained attention as a potential target for assessment with Quantitative Ultrasound (QUS). This systematic review examines the relationships between TLF QUS biomarkers (stiffness, shear strain, morphology, and microstructure) and NSLBP and how these biomarkers respond to interventions. Methods: Adhering to PRISMA 2020 guidelines, searches were conducted in MEDLINE, EMBASE, CENTRAL, and Scopus up to February 2026 for studies evaluating TLF QUS biomarkers in adults with NSLBP. Risk of bias was assessed using RoB 2, ROBINS-I, and NOS. Due to methodological heterogeneity, a narrative synthesis was performed. Findings: Fourteen studies involving approximately 880 participants met the inclusion criteria. In chronic NSLBP, several studies reported greater TLF thickness, altered echogenicity or microstructural texture parameters, and differences in stiffness compared with asymptomatic controls. However, stiffness findings were inconsistent across elastography modalities, with both higher and lower stiffness-related measures reported. Functional mobility findings also varied by clinical population and measurement protocol: studies in acute LBP generally reported reduced deformation, whereas studies in chronic LBP reported either reduced or increased shear strain. Preliminary intervention studies indicated changes in TLF thickness and selected stiffness-related measures following manual interventions, whereas single-session massage did not produce detectable changes in shear strain measures. Interpretation: QUS studies have identified differences in TLF morphology, mechanical properties, mobility, and microstructural texture parameters between some individuals with NSLBP and asymptomatic controls. The direction and magnitude of these differences are not uniform and vary across populations, imaging modalities, and acquisition protocols. The available findings may be consistent with different patterns of fascial mechanical behavior, but the existence of distinct biological or clinically actionable TLF phenotypes remains hypothetical and requires prospective validation. Evidence regarding responsiveness to intervention is preliminary, and the clinical utility of these parameters for diagnosis, treatment selection, or outcome monitoring has not yet been established.
- Open Access
- 24 October 2025
- Published by Centre pour la Communication Scientifique Directe (CCSD) in Multidisciplinary Biomechanics Journal
- Vol. 50th congr (Biomechani)
Evaluation of image quality parameters in lung using MR elastography technique
- 24 October 2025
- Published by Centre pour la Communication Scientifique Directe (CCSD) in Multidisciplinary Biomechanics Journal
- Vol. 50th congr (Biomechani)
Open AccessEvaluation of image quality parameters in lung using MR elastography technique
- Open Access
Age-Related Changes in Longitudinal and Transversal Elastic Properties of Murine Skeletal Muscle Fibers
- 20 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (9) , 2851-2858
Quantification of Lung Stiffness Using Magnetic Resonance Elastography (MRE): Clinical Validation for Smokers
Objective: Tobacco-related pathologies are the most preventable diseases. The purpose is to provide personalized cartography of smoker lung stiffness using non-irradiating imaging modalities, MRI and MRE (magnetic resonance imaging/elastography). Methods: Thirty-four smokers were divided into five groups distributed with a range of pack-years (PY) of 10. All patients underwent three imaging tests (CT: computed tomography, MRI, MRE) to make possible measurements of lung density, with two modalities (CT, MR), and stiffness. CT lung density was measured using the Hounsfield number. MR density was obtained from a fast gradient echo sequence and validated with an in vitro 3D abdominal phantom. The MRE test was performed with a motion-encoding gradient (Z direction), a spin-echo echo-planar sequence and four offsets. A pneumatic driver (frequency: 50 Hz) was placed on the right lung and four axial phase images were recorded. Post-processing was then performed to record a personalized stiffness cartography. Results: CT density significantly increased in relation to PY, showing denser tissue for the heavy smokers. As MR density acquisition is less accurate than CT, a slight increase in lung density was obtained. MRE tests revealed a significant increase in stiffness with pack-year. Patient-specific lung stiffness showed inhomogeneous distribution of values. Conclusion: MRE could provide a personalized cartography of stiffness for regular uptake of the lung's mechanical behavior in smokers. The stiffness could become a biomarker for preventing future lung disease. Significance: MRE test could be an alternative to CT test for the follow-up of smokers.
- 20 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (9) , 2851-2858
Quantification of Lung Stiffness Using Magnetic Resonance Elastography (MRE): Clinical Validation for Smokers
Objective: Tobacco-related pathologies are the most preventable diseases. The purpose is to provide personalized cartography of smoker lung stiffness using non-irradiating imaging modalities, MRI and MRE (magnetic resonance imaging/elastography). Methods: Thirty-four smokers were divided into five groups distributed with a range of pack-years (PY) of 10. All patients underwent three imaging tests (CT: computed tomography, MRI, MRE) to make possible measurements of lung density, with two modalities (CT, MR), and stiffness. CT lung density was measured using the Hounsfield number. MR density was obtained from a fast gradient echo sequence and validated with an in vitro 3D abdominal phantom. The MRE test was performed with a motion-encoding gradient (Z direction), a spin-echo echo-planar sequence and four offsets. A pneumatic driver (frequency: 50 Hz) was placed on the right lung and four axial phase images were recorded. Post-processing was then performed to record a personalized stiffness cartography. Results: CT density significantly increased in relation to PY, showing denser tissue for the heavy smokers. As MR density acquisition is less accurate than CT, a slight increase in lung density was obtained. MRE tests revealed a significant increase in stiffness with pack-year. Patient-specific lung stiffness showed inhomogeneous distribution of values. Conclusion: MRE could provide a personalized cartography of stiffness for regular uptake of the lung's mechanical behavior in smokers. The stiffness could become a biomarker for preventing future lung disease. Significance: MRE test could be an alternative to CT test for the follow-up of smokers.
- 2 November 2024
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 115, 110269
Monitoring of lung stiffness for long-COVID patients using magnetic resonance elastography (MRE)
- 2 November 2024
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 115, 110269
Monitoring of lung stiffness for long-COVID patients using magnetic resonance elastography (MRE)
- Open Access
- 22 June 2024
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 44 (3) , 337-356
Multiscale Mechanical Modeling of Skeletal Muscle: A Systemic Review of the Literature
Purpose: From the myofibrils to the whole muscle scale, muscle micro-constituents exhibit passive and active mechanical properties, potentially coupled to electrical, chemical, and thermal properties. Experimental characterization of some of these properties is currently not available for all muscle constituents. Multiscale multiphysics models have recently gained interest as a numerical alternative to investigate the healthy and diseased physiological behavior of the skeletal muscle. Methods: This paper refers to the multiscale mechanical models proposed in the literature to investigate the mechanical properties and behavior of skeletal muscles. More specifically, we focus on the scale transition methods, constitutive laws and experimental data implemented in these models. Results: Using scale transition methods such as homogenization, coupled to appropriate constitutive behavior of the constituents, these models explore the mechanisms of ageing, myopathies, sportive injuries, and muscle contraction. Conclusion: Emerging trends include the development of multiphysics simulations and the coupling of modeling with the acquisition of experimental data at different scales, with increasing focus to little known constituents such as the extracellular matrix and the protein titin.
- 22 June 2024
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 44 (3) , 337-356
Open AccessMultiscale Mechanical Modeling of Skeletal Muscle: A Systemic Review of the Literature
Purpose: From the myofibrils to the whole muscle scale, muscle micro-constituents exhibit passive and active mechanical properties, potentially coupled to electrical, chemical, and thermal properties. Experimental characterization of some of these properties is currently not available for all muscle constituents. Multiscale multiphysics models have recently gained interest as a numerical alternative to investigate the healthy and diseased physiological behavior of the skeletal muscle. Methods: This paper refers to the multiscale mechanical models proposed in the literature to investigate the mechanical properties and behavior of skeletal muscles. More specifically, we focus on the scale transition methods, constitutive laws and experimental data implemented in these models. Results: Using scale transition methods such as homogenization, coupled to appropriate constitutive behavior of the constituents, these models explore the mechanisms of ageing, myopathies, sportive injuries, and muscle contraction. Conclusion: Emerging trends include the development of multiphysics simulations and the coupling of modeling with the acquisition of experimental data at different scales, with increasing focus to little known constituents such as the extracellular matrix and the protein titin.
- 7 December 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 150, 106298
Multiscale analysis of Klf10's impact on the passive mechanical properties of murine skeletal muscle
- 7 December 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 150, 106298
Multiscale analysis of Klf10's impact on the passive mechanical properties of murine skeletal muscle