TLThomas Letzel

Thomas Letzel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Thomas Letzel has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Achroma: a software strategy for analysing (a-)typical mass-spectrometric data

    by Michael Krappmann, Thomas Letzel

    Today, (bio-)analytical researchers use various software tools for improving data analysis and the evaluation of their experimental results. Bioinformaticians typically program these software tools; however, analysts and bioinformaticians have distinct views on these data. Achroma is a software tool for the analysis of spectrometric data; it is our hope that explaining the software strategy and the working modules behind Achroma may give analysts a better understanding of how (bio-)informaticians work out software solutions, thus facilitating the interaction between these two expert groups. Achroma is based on a model-view-controller (MVC) software architecture. Furthermore, Achroma has a modular structure and each module has its own MVC architecture. Typically, each module delivers just one specific function to the user. Finally, every module is embedded within Achroma as a small “stand alone” software application. Analytically, Achroma software is a tool to handle typical and untypical mass spectrometric data. Achroma was originally programmed to circumvent problems with mass spectrometric vendor software in the analysis of data from new experimental strategies. Specifically, existing software enables the data analysis from continuous-flow mixing systems monitoring enzyme–inhibitor reactions only manually and indirectly. This data-handling bottleneck is resolved in Achroma. The principles behind this implementation are described in detail for two modules—the ‘chromatogram comparison’ and ‘signal recognition’ modules. Further specific examples of data analysis are presented, such as signal recognition, chromatogram smoothing and signal area calculation. We regard such understanding between the analysts' and programmers' worlds as essential for future improvements in analytical software.


  • Functional proteomics: application of mass spectrometry to the study of enzymology in complex mixtures

    by Johanna Graßmann, Romy K. Scheerle, Thomas Letzel

    This review covers recent developments in mass spectrometry-based applications dealing with functional proteomics with special emphasis on enzymology. The introduction of mass spectrometry into this research field has led to an enormous increase in knowledge in recent years. A major challenge is the identification of “biologically active substances” in complex mixtures. These biologically active substances are, on the one hand, potential regulators of enzymes. Elucidation of function and identity of those regulators may be accomplished by different strategies, which are discussed in this review. The most promising approach thereby seems to be the one-step procedure, because it enables identification of the functionality and identity of biologically active substances in parallel and thus avoids misinterpretation. On the other hand, besides the detection of regulators, the identification of endogenous substrates for known enzymes is an emerging research field, but in this case studies are quite rare. Moreover, the term biologically active substances may also encompass proteins with diverse biological functions. Elucidation of the functionality of those—so far unknown—proteins in complex mixtures is another branch of functional proteomics and those investigations will also be discussed in this review. Figure Mass spectrometric monitoring of enzymatic reactions


  • Enzymatic conversion continuously monitored with a robotic nanoESI-MS tool: experimental status

    by Romy K. Scheerle, Johanna Graßmann, Thomas Letzel

    The presented study describes an adaptation of enzymatic assays to miniaturized and automated nanoelectrospray ionization (nanoESI)-mass spectrometry (MS). The system consists of a liquid handling robot including an ESI chip source and offers several advantages for the investigation of enzymatic reactions. Therewith different parameters can be tested rapidly and automatically. Thus the technique provides a basis for the efficient development of enzymatic assays using MS detection. In the present project the miniaturized setup was applied to become appropriate for the investigation of various enzymatic assays since real-time measurements using automated nanospray robots are not reported in detail so far. The reaction of hen egg white lysozyme (HEWL) and the saccharide hexa-N-acetylchitohexaose (GlcNAc)6 was used as an exemplary model system. The generation of a stable nanoelectrospray using aqueous solution with enzymes/proteins was typically the main difficulty. Thus various parameters were systematically tested and adjusted to overcome these instabilities. This resulted in moderate, but improved, spray stability. Moreover, the new adjustments were applied to further enzymatic assays (chitinase, chymotrypsin and acetylcholinesterase). In doing so, they were tested whether they are applicable in universal manner. These assays reveal additional findings like a partial reduction of enzymatic activity in the nanoESI setup. The observed complicacies in spraying pure aqueous solutions and the partial enzyme inactivation will be discussed in detail as well as possible approaches to overcome them.