Ryan C. Arnold
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ryan C. Arnold has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Joseph E. Parrillo
4 shared publications- Stephen Trzeciak
Stephen Trzeciak, MD, MPH, is a Professor and Chair, Department of Medicine, Cooper University Health Care, Cooper Medical School of Rowan University, Camden, New Jersey, USA
4 shared publications Nathan I. Shapiro
3 shared publicationsR. Phillip Dellinger
3 shared publicationsStephen Trzeciak
3 shared publicationsAlan E. Jones
2 shared publications
Latest Publications
- 1 October 2012
- Published by Elsevier in Journal of Critical Care
- Vol. 27 (5) , 531.e1-531.e7
Discordance between microcirculatory alterations and arterial pressure in patients with hemodynamic instability
- 1 October 2012
- Published by Elsevier in Journal of Critical Care
- Vol. 27 (5) , 531.e1-531.e7
Discordance between microcirculatory alterations and arterial pressure in patients with hemodynamic instability
- Open Access
- 22 September 2011
- Published by Springer Nature in Critical Care
- Vol. 15 (5) , R223
The association of near-infrared spectroscopy-derived tissue oxygenation measurements with sepsis syndromes, organ dysfunction and mortality in emergency department patients with sepsis
Introduction: Near-infrared spectroscopy (NIRS) noninvasively measures peripheral tissue oxygen saturation (StO2). NIRS may be utilized along with a vascular occlusion test, in which limb blood flow is temporarily occluded and released, to quantify a tissue bed's rate of oxygen exchange during ischemia and recovery. The objective of this study was to test the hypothesis that NIRS-derived StO2 measures (StO2 initial, StO2 occlusion and StO2 recovery) identify patients who are in shock and at increased risk of organ dysfunction (Sequential Organ Failure Assessment (SOFA) score ≥ 2 at 24 hours) and dying in the hospital. Methods: This prospective, observational study comprised a convenience sample of three cohorts of adult patients (age > 17 years) at three urban university emergency departments: (1) a septic shock cohort (systolic blood pressure < 90 after fluid challenge; the "SHOCK" cohort, n = 58), (2) a sepsis without shock cohort (the "SEPSIS" cohort, n = 60) and emergency department patients without infection (n = 50). We measured the StO2 initial, StO2 occlusion and StO2 recovery slopes for all patients. Outcomes were sepsis syndrome severity, organ dysfunction (SOFA score at 24 hours) and in-hospital mortality. Results: Among the 168 patients enrolled, mean initial StO2 was lower in the SHOCK cohort than in the SEPSIS cohort (76% vs 81%), with an impaired occlusion slope (-10.2 and 5.2%/minute vs -13.1 and 4.4%/minute) and an impaired recovery slope (2.4 and 1.6%/second vs 3.9 and 1.7%/second) (P < 0.001 for all). The recovery slope was well-correlated with SOFA score at 24 hours (-0.35; P < 0.001), with a promising area under the curve (AUC) for mortality of 0.81. The occlusion slope correlation with SOFA score at 24 hours was 0.21 (P < 0.02), with a fair mortality AUC of 0.70. The initial StO2 was significantly but less strongly correlated with SOFA score at 24 hours (-0.18; P < 0.04), with a poor mortality AUC of 0.56. Conclusions: NIRS measurements for the StO2 initial, StO2 occlusion and StO2 recovery slope were abnormal in patients with septic shock compared to sepsis patients. The recovery slope was most strongly associated with organ dysfunction and mortality. Further validation is warranted. Trial registration: NCT01062685
- 22 September 2011
- Published by Springer Nature in Critical Care
- Vol. 15 (5) , R223
Open AccessThe association of near-infrared spectroscopy-derived tissue oxygenation measurements with sepsis syndromes, organ dysfunction and mortality in emergency department patients with sepsis
Introduction: Near-infrared spectroscopy (NIRS) noninvasively measures peripheral tissue oxygen saturation (StO2). NIRS may be utilized along with a vascular occlusion test, in which limb blood flow is temporarily occluded and released, to quantify a tissue bed's rate of oxygen exchange during ischemia and recovery. The objective of this study was to test the hypothesis that NIRS-derived StO2 measures (StO2 initial, StO2 occlusion and StO2 recovery) identify patients who are in shock and at increased risk of organ dysfunction (Sequential Organ Failure Assessment (SOFA) score ≥ 2 at 24 hours) and dying in the hospital. Methods: This prospective, observational study comprised a convenience sample of three cohorts of adult patients (age > 17 years) at three urban university emergency departments: (1) a septic shock cohort (systolic blood pressure < 90 after fluid challenge; the "SHOCK" cohort, n = 58), (2) a sepsis without shock cohort (the "SEPSIS" cohort, n = 60) and emergency department patients without infection (n = 50). We measured the StO2 initial, StO2 occlusion and StO2 recovery slopes for all patients. Outcomes were sepsis syndrome severity, organ dysfunction (SOFA score at 24 hours) and in-hospital mortality. Results: Among the 168 patients enrolled, mean initial StO2 was lower in the SHOCK cohort than in the SEPSIS cohort (76% vs 81%), with an impaired occlusion slope (-10.2 and 5.2%/minute vs -13.1 and 4.4%/minute) and an impaired recovery slope (2.4 and 1.6%/second vs 3.9 and 1.7%/second) (P < 0.001 for all). The recovery slope was well-correlated with SOFA score at 24 hours (-0.35; P < 0.001), with a promising area under the curve (AUC) for mortality of 0.81. The occlusion slope correlation with SOFA score at 24 hours was 0.21 (P < 0.02), with a fair mortality AUC of 0.70. The initial StO2 was significantly but less strongly correlated with SOFA score at 24 hours (-0.18; P < 0.04), with a poor mortality AUC of 0.56. Conclusions: NIRS measurements for the StO2 initial, StO2 occlusion and StO2 recovery slope were abnormal in patients with septic shock compared to sepsis patients. The recovery slope was most strongly associated with organ dysfunction and mortality. Further validation is warranted. Trial registration: NCT01062685
- 31 August 2009
- Published by Elsevier in Resuscitation
- Vol. 80 (8) , 893-897
Continuous cardiac index monitoring: A prospective observational study of agreement between a pulmonary artery catheter and a calibrated minimally invasive technique
- 31 August 2009
- Published by Elsevier in Resuscitation
- Vol. 80 (8) , 893-897
Continuous cardiac index monitoring: A prospective observational study of agreement between a pulmonary artery catheter and a calibrated minimally invasive technique
- 1 July 2009
- Published by Wolters Kluwer Health in Shock
- Vol. 32 (1) , 35-39
MULTICENTER STUDY OF EARLY LACTATE CLEARANCE AS A DETERMINANT OF SURVIVAL IN PATIENTS WITH PRESUMED SEPSIS
We sought to determine (a) if early lactate clearance is associated with improved survival in emergency department patients with severe sepsis and (b) the concordance between central venous oxygen saturation (ScvO2) optimization and lactate clearance during early sepsis resuscitation. Within a multicenter shock research network that uses quantitative resuscitation for severe sepsis, we analyzed prospectively collected registries of consecutive emergency department patients diagnosed with severe sepsis at three urban hospitals. Inclusion criteria are as follows: (a) age older than 17 years, (b) two or more systemic inflammation criteria, (c) systolic blood pressure 90 mmHg or less after fluid challenge or initial lactate of 4 mmol/L or greater, and (d ) initial and repeat lactate measurement within 6 h of resuscitation initiation. We stratified patients into two groups defined a priori based on previously published data: (a) lactate clearance--repeat lactate decrease by 10% or greater from initial (or both initial and repeat levels < or = 2.0 mmol/L), and (b) lactate non-clearance--repeat lactate decrease by less than 10% from initial. The primary outcome was in-hospital mortality. Among 166 patients, lactate non-clearance occurred in 15 (9%) of 166. Mortality was 60% for lactate nonclearance versus 19% for lactate clearance, P < 0.001. On multivariate analysis, lactate non-clearance was an independent predictor of death (odds ratio, 4.9 [confidence interval, 1.5-15.9]). We found discordance between ScvO2 optimization and lactate clearance; 79% of lactate non-clearance had concomitant ScvO2 of 70% or greater. In this multicenter cohort of sepsis patients, failing to clear lactate during resuscitation carried a high risk of death, and ScvO2 optimization did not reliably exclude lactate non-clearance. These data provide rationale for a clinical trial of lactate clearance as a distinct end point of early sepsis resuscitation.
- 1 July 2009
- Published by Wolters Kluwer Health in Shock
- Vol. 32 (1) , 35-39
MULTICENTER STUDY OF EARLY LACTATE CLEARANCE AS A DETERMINANT OF SURVIVAL IN PATIENTS WITH PRESUMED SEPSIS
We sought to determine (a) if early lactate clearance is associated with improved survival in emergency department patients with severe sepsis and (b) the concordance between central venous oxygen saturation (ScvO2) optimization and lactate clearance during early sepsis resuscitation. Within a multicenter shock research network that uses quantitative resuscitation for severe sepsis, we analyzed prospectively collected registries of consecutive emergency department patients diagnosed with severe sepsis at three urban hospitals. Inclusion criteria are as follows: (a) age older than 17 years, (b) two or more systemic inflammation criteria, (c) systolic blood pressure 90 mmHg or less after fluid challenge or initial lactate of 4 mmol/L or greater, and (d ) initial and repeat lactate measurement within 6 h of resuscitation initiation. We stratified patients into two groups defined a priori based on previously published data: (a) lactate clearance--repeat lactate decrease by 10% or greater from initial (or both initial and repeat levels < or = 2.0 mmol/L), and (b) lactate non-clearance--repeat lactate decrease by less than 10% from initial. The primary outcome was in-hospital mortality. Among 166 patients, lactate non-clearance occurred in 15 (9%) of 166. Mortality was 60% for lactate nonclearance versus 19% for lactate clearance, P < 0.001. On multivariate analysis, lactate non-clearance was an independent predictor of death (odds ratio, 4.9 [confidence interval, 1.5-15.9]). We found discordance between ScvO2 optimization and lactate clearance; 79% of lactate non-clearance had concomitant ScvO2 of 70% or greater. In this multicenter cohort of sepsis patients, failing to clear lactate during resuscitation carried a high risk of death, and ScvO2 optimization did not reliably exclude lactate non-clearance. These data provide rationale for a clinical trial of lactate clearance as a distinct end point of early sepsis resuscitation.
- 24 June 2009
- Published by Springer Nature in Intensive Care Medicine
- Vol. 35 (10) , 1761-1766
Point-of-care assessment of microvascular blood flow in critically ill patients
Objective Sublingual microvascular videomicroscopy can assess tissue perfusion in critically ill patients; however, data analysis is currently limited to delayed off-line evaluation. We hypothesized that a real-time point-of-care (POC) determination of the microcirculatory flow index (MFI), an established metric for assessing microcirculatory perfusion, agrees well with the conventional off-line analysis. Design Prospective observational study. Setting Urban academic intensive care unit. Participants A heterogeneous population of critically ill patients. Measurements and results A single operator performed side stream darkfield videomicroscopy of the sublingual microcirculation and made a POC determination of MFI in real-time on a portable bedside monitor by assigning a score (0 = no flow to 3 = normal) to each quadrant of the image and averaging the four values. After image processing, de-identification and randomization, the same operator, blinded to the previous interpretation, repeated the MFI assessment by viewing an AVI-formatted image sequence on a 94 cm 1,080 pixel LCD monitor (reference standard). There were 205 paired measurements in 18 subjects. The POC and reference standard MFI had good agreement by Bland–Altman analysis [mean difference of −0.031, SD = 0.198 (95% CI, −0.43 to 0.37)]. The POC assessment was 94% sensitive and 92% specific for detecting impaired microvascular flow (defined a priori as an MFI < 2.5 based on previously published data). Conclusions A POC determination of MFI had good agreement with conventional off-line analysis, and was highly sensitive and specific for detecting impaired microvascular flow. This real-time technique may be useful in future clinical trials targeting impaired microcirculatory perfusion in critically ill patients.
- 24 June 2009
- Published by Springer Nature in Intensive Care Medicine
- Vol. 35 (10) , 1761-1766
Point-of-care assessment of microvascular blood flow in critically ill patients
Objective Sublingual microvascular videomicroscopy can assess tissue perfusion in critically ill patients; however, data analysis is currently limited to delayed off-line evaluation. We hypothesized that a real-time point-of-care (POC) determination of the microcirculatory flow index (MFI), an established metric for assessing microcirculatory perfusion, agrees well with the conventional off-line analysis. Design Prospective observational study. Setting Urban academic intensive care unit. Participants A heterogeneous population of critically ill patients. Measurements and results A single operator performed side stream darkfield videomicroscopy of the sublingual microcirculation and made a POC determination of MFI in real-time on a portable bedside monitor by assigning a score (0 = no flow to 3 = normal) to each quadrant of the image and averaging the four values. After image processing, de-identification and randomization, the same operator, blinded to the previous interpretation, repeated the MFI assessment by viewing an AVI-formatted image sequence on a 94 cm 1,080 pixel LCD monitor (reference standard). There were 205 paired measurements in 18 subjects. The POC and reference standard MFI had good agreement by Bland–Altman analysis [mean difference of −0.031, SD = 0.198 (95% CI, −0.43 to 0.37)]. The POC assessment was 94% sensitive and 92% specific for detecting impaired microvascular flow (defined a priori as an MFI < 2.5 based on previously published data). Conclusions A POC determination of MFI had good agreement with conventional off-line analysis, and was highly sensitive and specific for detecting impaired microvascular flow. This real-time technique may be useful in future clinical trials targeting impaired microcirculatory perfusion in critically ill patients.
- 1 December 2004
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 32 (Supplement) , A156
MICROCIRCULATORY PERFUSION IN SEVERE SEPSIS CORRELATES WITH HEMODYNAMIC PARAMETERS
- 1 December 2004
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 32 (Supplement) , A156
MICROCIRCULATORY PERFUSION IN SEVERE SEPSIS CORRELATES WITH HEMODYNAMIC PARAMETERS
- 1 December 2004
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 32 (Supplement) , A156
MICROCIRCULATORY PERFUSION IN SEVERE SEPSIS DOES NOT CORRELATE WITH LACTATE
- 1 December 2004
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 32 (Supplement) , A156
MICROCIRCULATORY PERFUSION IN SEVERE SEPSIS DOES NOT CORRELATE WITH LACTATE