Martin Scheer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Martin Scheer has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Uta Drebber
4 shared publicationsA. C. Kübler
Klinik und Poliklinik für Zahnärztliche Chirurgie und für Mund-, Kiefer- und Plastische Gesichtschirurgie der Universität zu Köln
3 shared publicationsJ. E. Zöller
Universität zu Köln
2 shared publicationsJoachim E. Zoeller
2 shared publicationsJoerg Neugebauer
2 shared publications- Jörg Neugebauer
Max Planck Institute for Sustainable Materials, Düsseldorf, Germany
2 shared publications
Latest Publications
- 10 October 2016
- Published by Editora Napoleao Ltda ME in The International Journal of Oral and Maxillofacial Implants
- Vol. 1 (4) , 776
Comparação de Modelos e Medidas de Torque de Várias Chaves Manuais
- 10 October 2016
- Published by Editora Napoleao Ltda ME in The International Journal of Oral and Maxillofacial Implants
- Vol. 1 (4) , 776
Comparação de Modelos e Medidas de Torque de Várias Chaves Manuais
- 3 February 2012
- Vol. 27 (1) , 128-37
Accuracy of a newly developed open-source system for dental implant planning.
To evaluate the accuracy of a newly developed open-source system for three-dimensional dental implant planning and fully guided dental implant placement. Forty-eight implant positions were planned for eight partially edentulous anatomical patient equivalent models with an open-source implant planning system on the basis of cone beam computed tomography (CBCT) scans. The virtual software planning leads to an output of four different coordinates for each implant position; with these, surgical guides were manufactured using a coordinate-transfer apparatus. During the surgical simulation, drills and implants were fully guided as they were inserted by means of the harmonized components of the vendor's sleeve-in-sleeve system. After follow-up CBCT investigation and reference marker-based software registration, linear horizontal, vertical, and maximal 3D deviations, as well as angular deviations, between the virtual planning data and the surgical results were calculated. The mean three-dimensional deviation values for the final implant positions were 671 μm (95% confidence interval [CI] 452 to 891 μm) at the implant base and 808 μm (95% CI 646 to 971 μm) at the implant tip. Mean vertical deviations were 273 μm (95% CI 200 to 345 μm). Mean angular deviations of 1.9 degrees (95% CI 1.4 to 2.4 degrees) were measured. The open-source implant planning system described in this study demonstrated a level of accuracy that is equal or superior to most descriptions of the literature on computer-aided implant dentistry, allows for predictable implant positioning, and has the potential to reduce postoperative impairment versus conventional implant insertion.
- 3 February 2012
- Vol. 27 (1) , 128-37
Accuracy of a newly developed open-source system for dental implant planning.
To evaluate the accuracy of a newly developed open-source system for three-dimensional dental implant planning and fully guided dental implant placement. Forty-eight implant positions were planned for eight partially edentulous anatomical patient equivalent models with an open-source implant planning system on the basis of cone beam computed tomography (CBCT) scans. The virtual software planning leads to an output of four different coordinates for each implant position; with these, surgical guides were manufactured using a coordinate-transfer apparatus. During the surgical simulation, drills and implants were fully guided as they were inserted by means of the harmonized components of the vendor's sleeve-in-sleeve system. After follow-up CBCT investigation and reference marker-based software registration, linear horizontal, vertical, and maximal 3D deviations, as well as angular deviations, between the virtual planning data and the surgical results were calculated. The mean three-dimensional deviation values for the final implant positions were 671 μm (95% confidence interval [CI] 452 to 891 μm) at the implant base and 808 μm (95% CI 646 to 971 μm) at the implant tip. Mean vertical deviations were 273 μm (95% CI 200 to 345 μm). Mean angular deviations of 1.9 degrees (95% CI 1.4 to 2.4 degrees) were measured. The open-source implant planning system described in this study demonstrated a level of accuracy that is equal or superior to most descriptions of the literature on computer-aided implant dentistry, allows for predictable implant positioning, and has the potential to reduce postoperative impairment versus conventional implant insertion.
- 1 May 2011
- Published by Elsevier in Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology
- Vol. 111 (5) , 568-577
Autofluorescence imaging of potentially malignant mucosa lesions
- 1 May 2011
- Published by Elsevier in Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology
- Vol. 111 (5) , 568-577
Autofluorescence imaging of potentially malignant mucosa lesions
- 1 January 2011
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 69 (1) , 222-226
Combined Intra- and Extracranial Cryptococcal Infection of a 20-Year-Old Patient in Right Temporal Area
- 1 January 2011
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 69 (1) , 222-226
Combined Intra- and Extracranial Cryptococcal Infection of a 20-Year-Old Patient in Right Temporal Area
- 11 October 2009
- Published by Springer Nature in Oral and Maxillofacial Surgery
- Vol. 14 (1) , 53-57
Expression of cyclooxygenase-2 (COX-2) in an advanced metastasized hypopharyngeal carcinoma and cultured tumor cells
The inducible enzyme cyclooxygenase-2 (COX-2) catalyzes PGE2 production and plays an important role in the progression of many solid cancers. However, the role of COX-2 expression in cervical lymph node metastases of head and neck cancer has not been clarified yet. We comment on a male patient aged 53 who was admitted to an ENT-department with acute bleeding from an advanced hypopharyngeal carcinoma and a frontotemporal mass. Prior to palliative intended radiotherapy, the metastasis was resected. During the procedure, a small amount of tumor tissue was harvested for primary tumor cell culture. COX-2 overexpression was demonstrated in the primary tumor tissue, the metastasis, in the cultured tumor cells by standard immunohistochemistry, as well as cytochemistry. A simultaneous expression of COX-2 in head and neck carcinoma was presented for the first time. Besides the prognostic impact in oral carcinogenesis, this COX-2 role of biomarker for aggressive head and neck squamous cell carcinomas should be further evaluated. Additionally, treatment of hypopharyngeal carcinomas with selective COX-2 inhibitors could be beneficial when administered in combination with radiochemotherapy.
- 11 October 2009
- Published by Springer Nature in Oral and Maxillofacial Surgery
- Vol. 14 (1) , 53-57
Expression of cyclooxygenase-2 (COX-2) in an advanced metastasized hypopharyngeal carcinoma and cultured tumor cells
The inducible enzyme cyclooxygenase-2 (COX-2) catalyzes PGE2 production and plays an important role in the progression of many solid cancers. However, the role of COX-2 expression in cervical lymph node metastases of head and neck cancer has not been clarified yet. We comment on a male patient aged 53 who was admitted to an ENT-department with acute bleeding from an advanced hypopharyngeal carcinoma and a frontotemporal mass. Prior to palliative intended radiotherapy, the metastasis was resected. During the procedure, a small amount of tumor tissue was harvested for primary tumor cell culture. COX-2 overexpression was demonstrated in the primary tumor tissue, the metastasis, in the cultured tumor cells by standard immunohistochemistry, as well as cytochemistry. A simultaneous expression of COX-2 in head and neck carcinoma was presented for the first time. Besides the prognostic impact in oral carcinogenesis, this COX-2 role of biomarker for aggressive head and neck squamous cell carcinomas should be further evaluated. Additionally, treatment of hypopharyngeal carcinomas with selective COX-2 inhibitors could be beneficial when administered in combination with radiochemotherapy.
- 10 July 2009
- Vol. 24 (3) , 469-76
Comparison of torque measurements and clinical handling of various surgical motors.
Modern implant dentistry requires the application of torque during various treatment steps. This study investigated seven different surgical motors for the accuracy of the applied torque and their reliability. The following surgical motors were evaluated: Chiropro 980 (Bienair), INTRAsurg 300 and INTRAsurg 500 (KaVo), Osseocare (Nobel Biocare), Surgic XT (NSK), Elcomed SA-200 C (W and H), and Osseo System (XO Dentalcare). The torque was measured during typical surgical and prosthetic procedures using a special load transfer mechanism for a torque gauge. For each setting, 30 measurements were made and means were calculated. The highest percentage shortfall was 20.5% at a set torque of 11.4 Ncm (absolute deviation of -2.4 Ncm). The highest percentage by which a torque was exceeded was 54.6% (absolute deviation of 5.5 Ncm). The lowest value for absolute shortfall was found to be -5.6 Ncm at a set torque of 45 Ncm. The highest absolute exceeded was 15 Ncm at a set torque of 40 Ncm. Potentially problematic torque values were identified in the low-torque-value setting, as the implant position may be changed if a machine driver applies excessive torque to the first-stage healing screw. In addition, in the indication of immediate loading in the high-set-torque group, torque values above the critical value of 50 Ncm may be unwittingly applied while working with a set torque of 40 Ncm. For most of the clinically relevant torque settings, precise values were measured, although a few devices delivered potentially problematic torque values for some of the indications.
- 10 July 2009
- Vol. 24 (3) , 469-76
Comparison of torque measurements and clinical handling of various surgical motors.
Modern implant dentistry requires the application of torque during various treatment steps. This study investigated seven different surgical motors for the accuracy of the applied torque and their reliability. The following surgical motors were evaluated: Chiropro 980 (Bienair), INTRAsurg 300 and INTRAsurg 500 (KaVo), Osseocare (Nobel Biocare), Surgic XT (NSK), Elcomed SA-200 C (W and H), and Osseo System (XO Dentalcare). The torque was measured during typical surgical and prosthetic procedures using a special load transfer mechanism for a torque gauge. For each setting, 30 measurements were made and means were calculated. The highest percentage shortfall was 20.5% at a set torque of 11.4 Ncm (absolute deviation of -2.4 Ncm). The highest percentage by which a torque was exceeded was 54.6% (absolute deviation of 5.5 Ncm). The lowest value for absolute shortfall was found to be -5.6 Ncm at a set torque of 45 Ncm. The highest absolute exceeded was 15 Ncm at a set torque of 40 Ncm. Potentially problematic torque values were identified in the low-torque-value setting, as the implant position may be changed if a machine driver applies excessive torque to the first-stage healing screw. In addition, in the indication of immediate loading in the high-set-torque group, torque values above the critical value of 50 Ncm may be unwittingly applied while working with a set torque of 40 Ncm. For most of the clinically relevant torque settings, precise values were measured, although a few devices delivered potentially problematic torque values for some of the indications.
- 19 October 2006
- Published by Springer Nature in Mund-,Kiefer- und Gesichtschirurgie
- Vol. 10 (6) , 403-407
Pimecrolimus (ELIDEL®) zur Behandlung des Lichen planus mucosae
Im Rahmen der Studie wurden insgesamt fünf Patienten mit histologisch gesichertem oralem Lichen planus (OLP) angewiesen, über vier Wochen zweimal täglich 1%ige Pimecrolimus-Creme auf die betroffenen Areale aufzutragen. Vor Beginn der Behandlung und nach 7, 14, 28 und 42 Tagen wurden die Schleimhautareale klinisch beurteilt und fotografiert. Anhand einer visuellen Analog-Skala (VAS) sollten die Patienten wöchentlich das Ausmaß der Beschwerden bewerten. Die eingeschlossenen Patienten (Durchschnittsalter 65,6 Jahre) waren alle weiblich und litten an einem OLP des Planum buccale. Der Vergleich der VAS-Scores unter der Behandlung zeigte eine signifikante Reduktion der Beschwerden (p = 0,0014). Klinisch war eine deutliche Abnahme der Rötung der betroffenen Areale erkennbar. Von 4 der 5 Patientinnen wurde die mangelnde Haftung der Pimecrolimus-Creme beklagt. Obgleich keine vollständige Remission erreicht werden konnte, gingen die entzündlichen Beschwerden und die Rötung der betroffenen Schleimhautareale durch die Lokalbehandlung mit Pimecrolimus zurück. Im Rahmen weiterer, kontrollierter Studien sollte die Wirksamkeit im Vergleich zur topischen Kortikoidtherapie evaluiert werden. Für die intraorale Anwendung sollte die Haftung auf der Schleimhaut verbessert werden. Oral lichen planus (OLP) is a common chronic inflammatory disorder with criteria of auto-reactive disease. Treatment consists on topical application of corticosteroids, vitamin A derivates or cyclosporin. Calcineurin inhibitors as tacrolimus and pimecrolimus decrease the production of cytokines and inhibit T-cell proliferation. These substances have recently been introduced for local therapy of chronic inflammatory skin disorders. The aim of our study was to evaluate the effectiveness and side effects of local pimecrolimus in OLP. A group of five patients with histological proven OLP were treated with topical pimecrolimus 1% ointment twice daily to the affected area. Prior to treatment and after 7, 14, 28 and 42 days the lesions were assessed clinically and by photographs. The discomfort scores were evaluated by visual analogue scale (VAS) weekly. All five patients (median age 65.6 years) were female and showed involvement of the buccal mucosa. All lesions showed a reduction of inflammation activity during the treating period. The VAS scores decreased significantly under treatment (p = 0,0014). Pimecrolimus ointment was tolerated well with no signs of itching or burning. However, 4 out of 5 patients complained about the reduced adherence properties of the cream. Although no complete remission of OLP has been observed in our series, signs of inflammatory activity of OLP as redness and burning sensations were reduced by topical pimecrolimus. Further controlled randomized studies have to be conducted to compare topical pimecrolimus with topical corticosteroid as standard therapy. The adherence properties of pimecrolimus 1% cream should be improved for intra-oral application.
- 19 October 2006
- Published by Springer Nature in Mund-,Kiefer- und Gesichtschirurgie
- Vol. 10 (6) , 403-407
Pimecrolimus (ELIDEL®) zur Behandlung des Lichen planus mucosae
Im Rahmen der Studie wurden insgesamt fünf Patienten mit histologisch gesichertem oralem Lichen planus (OLP) angewiesen, über vier Wochen zweimal täglich 1%ige Pimecrolimus-Creme auf die betroffenen Areale aufzutragen. Vor Beginn der Behandlung und nach 7, 14, 28 und 42 Tagen wurden die Schleimhautareale klinisch beurteilt und fotografiert. Anhand einer visuellen Analog-Skala (VAS) sollten die Patienten wöchentlich das Ausmaß der Beschwerden bewerten. Die eingeschlossenen Patienten (Durchschnittsalter 65,6 Jahre) waren alle weiblich und litten an einem OLP des Planum buccale. Der Vergleich der VAS-Scores unter der Behandlung zeigte eine signifikante Reduktion der Beschwerden (p = 0,0014). Klinisch war eine deutliche Abnahme der Rötung der betroffenen Areale erkennbar. Von 4 der 5 Patientinnen wurde die mangelnde Haftung der Pimecrolimus-Creme beklagt. Obgleich keine vollständige Remission erreicht werden konnte, gingen die entzündlichen Beschwerden und die Rötung der betroffenen Schleimhautareale durch die Lokalbehandlung mit Pimecrolimus zurück. Im Rahmen weiterer, kontrollierter Studien sollte die Wirksamkeit im Vergleich zur topischen Kortikoidtherapie evaluiert werden. Für die intraorale Anwendung sollte die Haftung auf der Schleimhaut verbessert werden. Oral lichen planus (OLP) is a common chronic inflammatory disorder with criteria of auto-reactive disease. Treatment consists on topical application of corticosteroids, vitamin A derivates or cyclosporin. Calcineurin inhibitors as tacrolimus and pimecrolimus decrease the production of cytokines and inhibit T-cell proliferation. These substances have recently been introduced for local therapy of chronic inflammatory skin disorders. The aim of our study was to evaluate the effectiveness and side effects of local pimecrolimus in OLP. A group of five patients with histological proven OLP were treated with topical pimecrolimus 1% ointment twice daily to the affected area. Prior to treatment and after 7, 14, 28 and 42 days the lesions were assessed clinically and by photographs. The discomfort scores were evaluated by visual analogue scale (VAS) weekly. All five patients (median age 65.6 years) were female and showed involvement of the buccal mucosa. All lesions showed a reduction of inflammation activity during the treating period. The VAS scores decreased significantly under treatment (p = 0,0014). Pimecrolimus ointment was tolerated well with no signs of itching or burning. However, 4 out of 5 patients complained about the reduced adherence properties of the cream. Although no complete remission of OLP has been observed in our series, signs of inflammatory activity of OLP as redness and burning sensations were reduced by topical pimecrolimus. Further controlled randomized studies have to be conducted to compare topical pimecrolimus with topical corticosteroid as standard therapy. The adherence properties of pimecrolimus 1% cream should be improved for intra-oral application.
- 19 August 2005
- Published by Springer Nature in Mund-,Kiefer- und Gesichtschirurgie
- Vol. 9 (5) , 282-289
Endosonographische Darstellung der Tumordicke von oralen Plattenepithelkarzinomen und deren Einfluss auf die Inzidenz von Lymphknotenmetastasen
- 19 August 2005
- Published by Springer Nature in Mund-,Kiefer- und Gesichtschirurgie
- Vol. 9 (5) , 282-289
Endosonographische Darstellung der Tumordicke von oralen Plattenepithelkarzinomen und deren Einfluss auf die Inzidenz von Lymphknotenmetastasen
- 1 June 2004
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 32 (3) , 166-169
Primary intraosseous carcinoma of the jaws arising from an odontogenic cyst – a case report
- 1 June 2004
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 32 (3) , 166-169
Primary intraosseous carcinoma of the jaws arising from an odontogenic cyst – a case report
- 1 April 2004
- Published by S. Karger AG in Oncology Research and Treatment
- Vol. 27 (2) , 187-193
Chemoprevention of Oral Squamous Cell Carcinomas
Among individuals with a history of head and neck cancer and tobacco abuse the risk of second primary cancers in the upper aerodigestive tract is high. Chemoprevention of oral squamous cell carcinomas is based on two conditions: Premalignant mucosa lesions are treated with chemopreventive agents in order to prevent malignant conversion (primary prevention). In secondary prevention of oral cancer, after curative therapy patients are treated by chemoprevention in order to reduce the rate of second primaries. This paper presents a comprehensive clinical review of oral cancer prevention studies, highlighting the agents mostly used, such as beta-carotene, alpha-tocopherol, ascorbic acid, and retinoids. Although most intervention trials showed good overall response with these substances, high relapse rates and serious side effects, in most cases related to the retinoid compounds were noticed. In addition, in all prospective randomized chemoprevention trials (CARET, ATBC and PHS) no significant evidence of benefit for supplementation with alpha-tocopherol, beta-carotene or retinyl palmitate was reported.
- 1 April 2004
- Published by S. Karger AG in Oncology Research and Treatment
- Vol. 27 (2) , 187-193
Chemoprevention of Oral Squamous Cell Carcinomas
Among individuals with a history of head and neck cancer and tobacco abuse the risk of second primary cancers in the upper aerodigestive tract is high. Chemoprevention of oral squamous cell carcinomas is based on two conditions: Premalignant mucosa lesions are treated with chemopreventive agents in order to prevent malignant conversion (primary prevention). In secondary prevention of oral cancer, after curative therapy patients are treated by chemoprevention in order to reduce the rate of second primaries. This paper presents a comprehensive clinical review of oral cancer prevention studies, highlighting the agents mostly used, such as beta-carotene, alpha-tocopherol, ascorbic acid, and retinoids. Although most intervention trials showed good overall response with these substances, high relapse rates and serious side effects, in most cases related to the retinoid compounds were noticed. In addition, in all prospective randomized chemoprevention trials (CARET, ATBC and PHS) no significant evidence of benefit for supplementation with alpha-tocopherol, beta-carotene or retinyl palmitate was reported.