CSChristian F. J. Stappert

Christian F. J. Stappert

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Christian F. J. Stappert has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 23 May 2012
      • Vol. 27  (3) , 537-43

    Marginal accuracy of three implant-ceramic abutment configurations.

    by Marta Baldassarri, Jenni Hjerppe, Davide Romeo, Stefan Fickl, Van P Thompson, Christian F J Stappert

    Microgaps at the implant-abutment interface allow for microbial colonization, which can lead to peri-implant tissue inflammation. This study sought to determine the marginal accuracy of three different implant-zirconium oxide (zirconia) abutment configurations and one implant?titanium abutment configuration. Three combinations of implants with custom-made zirconia abutments were analyzed (n = 5/group): NobelProcera abutments/titanium inserts on Replace Select Tapered TiUnite implants (Nobel Biocare) (NP); Encode abutments/NanoTite Tapered Certain implants (Biomet 3i) (B3i); Astra Tech Dental Atlantis abutments/Biomet 3i NanoTite Tapered Certain implants (At). Five custom-made Encode titanium abutments/NanoTite Tapered Certain implants (Ti) were used as a control group. All abutments were fabricated with computer-aided design/computer-assisted manufacture. One-hundred twenty vertical gap measurements were made per sample using scanning electron microscopy (15 scans x 4 aspects of each specimen [buccal, mesial, palatal, distal] x 2 measurements). Analysis of variance was used to compare the marginal fit values among the four groups, the specimens within each group, and the four aspects of each specimen. Mean (± standard deviation) gap values were 8.4 ± 5.6 Μm (NP), 5.7 ± 1.9 Μm (B3i), 11.8 ± 2.6 Μm (At), and 1.6 ± 0.5 Μm (Ti). A significant difference was found between B3i and At. No difference resulted between NP with the other two groups. Gap values were significantly smaller for Ti relative to all zirconia systems. For each ceramic abutment configuration, the fit was significantly different among the five specimens. For 12 of the 15 ceramic abutment specimens, gap values sorted by aspect were significantly different. The implant?titanium abutment connection showed significantly better fit than all implant?zirconia abutment configurations, which demonstrated mean gaps that were approximately three to seven times larger than those in the titanium abutment system.


  • Reliability and fatigue failure modes of implant‐supported aluminum‐oxide fixed dental prostheses

    by Christian F. J. Stappert, Marta Baldassarri, Yu Zhang, Felix Hänssler, Elizabeth D. Rekow, Van P. Thompson

    Objectives: To investigate failure modes and reliability of implant‐supported aluminum‐oxide three‐unit fixed dental prostheses (FDPs) using two different veneering porcelains.Material and methods: Thirty‐six aluminum‐oxide FDP frameworks were computer‐aided designed and computer‐aided manufactured and either hand‐veneered(n = 18) or over‐pressed(n = 18). All FDPs were adhesively luted to custom‐made zirconium‐oxide‐abutments attached to dental implant fixtures (regular platform 4 × 13 mm). Specimens were stored in water before mechanical testing. A step‐stress accelerated life test (SSALT) with three load/cycles varying profiles was developed based on initial single‐load‐to‐failure testing. Failure was defined by veneer chipping or chipping in combination with framework fracture. SSALT was performed on each FDP inclined 30° with respect to the applied load direction. For all specimens, failure modes were analyzed using polarized reflected light microscopy and scanning electron microscopy. Reliability was computed using Weibull analysis software (Reliasoft).Results: The dominant failure mode for the over‐pressed FDPs was buccal chipping of the porcelain in the loading area of the pontic, while hand‐veneered specimens failed mainly by combined failure modes in the veneering porcelain, framework, and abutments. Chipping of the porcelain occurred earlier in the over‐pressed specimens (350 N/85 k, load/cycles) than in the hand‐veneered ones (600 N/110 k) (profile I). Given a mission at 300 N load and 100 or 200 k cycles, the computed Weibull reliability (two‐sided at 90% confidence bounds) was 0.99(1/0.98) and 0.99(1/0.98) for hand‐veneered FDPs and 0.45(0.76/0.10) and 0.05(0.63/0) for over‐pressed FDPs, respectively.Conclusions: In the range of average clinical loads (300–700 N), hand‐veneered aluminum‐oxide FDPs showed significantly less failure by chipping of the veneer than the over‐pressed. Hand‐veneered FDPs under fatigue loading failed at loads ≥600 N.


  • Reliability and failure modes of implant-supported zirconium-oxide fixed dental prostheses related to veneering techniques

    by Marta Baldassarri, Yu Zhang, Van P. Thompson, Elizabeth D. Rekow, Christian F.J. Stappert


  • Effect of mouth-motion fatigue and thermal cycling on the marginal accuracy of partial coverage restorations made of various dental materials

    by Christian F.J. Stappert, Somsak Chitmongkolsuk, Nelson R.F.A. Silva, Wael Att, Joerg R. Strub


  • Masticatory fatigue, fracture resistance, and marginal discrepancy of ceramic partial crowns with and without coverage of compromised cusps.

    by Christian F J Stappert, Pia Abe, Volker Kurths, Thomas Gerds, Jörg R Strub

    To evaluate preparation designs of compromised cusps and whether or not they influence masticatory fatigue, fracture resistance, and marginal discrepancy of ceramic partial-coverage restorations (PCRs) luted on mandibular molars. Sixty-four caries-free molars were equally divided into four groups. Control group NP received no preparation (NP). Group B-IN received a basic inlay (IN) preparation with buccal (B) cusp conservation and occlusal reduction of both lingual cusps. Group B-ON was prepared in the same way, except buccal cusps were prepared with an angle of 45 degrees to the occlusal plane (buccal onlay). Group B-OV preparation was similar to group B-ON, but buccal cusps received a further shoulder preparation on the buccal aspect (buccal overlap). Forty-eight all-ceramic IPS e.max Press PCRs were fabricated and luted adhesively. Specimens underwent mouth-motion fatigue (1.2 million cycles, 1.6 Hz, 49 N) and 5500 thermal cycles (5 degrees C/55 degrees C). Fracture patterns were observed. Surviving specimens were loaded until fracture. Marginal discrepancies were examined. Only one specimen of group B-ON fractured during fatigue. Median fracture loads (N) [IQR = x(.25) - x(.75)]: group NP = 1604 N [1182-1851 N], group B-IN = 1307 N [1262-1587N], group B-ON = 1396 N [817-1750N], group B-OV = 1205 N [1096-1542N]. No significant differences in fracture resistance were found between restored molars and unprepared teeth (p _ 0.18). Different preparation designs showed no significant influence on PCR fracture resistance. Mouth-motion fatigue caused a significanty decrease of marginal accuracy in groups B-IN (p = 0.009) and B-ON (p = 0.008). Marginal discrepancy values of groups B-IN and B-OV were significantly different after fatigue (p = 0.045). Ceramic coverage of compromised cusps did not demonstrate an increase of fracture resistance after fatigue when compared to less invasive partial-coverage restorations. However, enhanced exposure of restoration margins to occlusal wear could result in more extensive marginal discrepancies.


    • 1 December 2007
      • Vol. 20  (6) , 380-4

    Marginal accuracy of press-ceramic veneers influenced by preparation design and fatigue.

    by Christian F J Stappert, Ummuhan Ozden, Wael Att, Thomas Alexander Gerds, Joerg R Strub

    To investigate the influence of preparation design and mouth motion fatigue on the marginal accuracy of press-ceramic veneers bonded to human maxillary central incisors. Forty-eight extracted human maxillary central incisors divided in three groups of 16 specimens each, received veneer preparations. In Group WP a window preparation (WP) was performed. Specimens in Group IOP were prepared with an incisal overlap (IOP) of 2 mm without palatal chamfer. For Group CVP, specimens received a complete-veneer preparation (CVP) of 3 mm incisal reduction and 2 mm palatal extension. Veneers were fabricated with IPS Empress and bonded adhesively with dual polymerizing composite Variolink II. The discrepancies of marginal fit were examined on epoxy replicas before and after mouth motion fatigue at x200 magnification. The mean (geometrical) (95% confidence limits) marginal accuracy after cementation was recorded as follows: WP-46 (43-49) microm, IOP-46 (44-49) microm and CVP-54 (51-58) microm. Fatigue led to a significant decrease of marginal accuracy in all groups (P < 0.036) [WP-47 (44-50) microm, IOP-51 (48-53) microm and CVP-63 (59-67) microm]. Group CVP demonstrated significantly higher marginal gap values than groups WP and IOP, before and after fatigue (P < 0.004). No significant differences were found between groups WP and IOP.


    • 1 June 2007
      • Vol. 19  (5) , 300-1

    Tooth structure preservation by extended veneer restorations.

    by Christian F J Stappert

    • 1 February 2007
      • Vol. 20  (1) , 21-6

    All-ceramic partial coverage restorations on natural molars. Masticatory fatigue loading and fracture resistance.

    by Christian F J Stappert, Petra C Guess, Somsak Chitmongkolsuk, Thomas Alexander Gerds, Jorg R Strub

    To determine the reliability and fracture resistance of adhesively luted all-ceramic partial coverage restorations (PCR) on natural upper molars after masticatory fatigue loading. 64 maxillary molars were divided into four groups of 16 specimens each. Control Group NP remained unprepared. Teeth in Groups EM, EX and PC were prepared equally according to standardized guidelines and restored with the following PCR: Group EM = IPS Empress; Group EX = IPS e.max Press; Group PC = ProCAD/Cerec 3. The 48 PCR were all bonded adhesively with dual polymerizing composite (Variolink II). All specimens were subjected to cyclic mechanical loading (1.2 million cycles, 1.6 Hz, invariable occlusal load 49 N) with thermal cycling (5 degrees C/55 degrees C, dwell time 60 seconds, 5500 cycles) in a mastication simulator. Failure was defined by bulk fracture of a specimen. Subcritical crack patterns were observed. Surviving specimens were loaded until fracture in a universal testing machine. The load to fracture values (N) (1.5 mm/minute crosshead speed) were automatically recorded by controlling software. Statistical analysis of the data was performed by Kruskal Wallis test (ANOVA) (alpha = 0.05) and pair-wise Wilcoxon rank sum test (alpha = 0.05). All specimens survived mastication simulation. The following median fracture resistance values (N) (IQR = x.25-x.75) were recorded: Group-NP 1960 (1481-2228), Group-EM 1400 (1043-1722), Group-EX 1489 (1114-1751), Group-PC 2134 (2052-2391). The load-to-fracture values of Groups NP and PC in particular were significantly higher (P < 0.05) than those of Groups EM and EX. ProCAD restorations demonstrated the best predictability of failure (SD <). Within the limitations of this study, maxillary molars restored with ProCAD PCR showed a similar fracture resistance when compared to natural teeth. Since the majority of IPS e.max Press and ProCad restorations survived loads within the range of physiological mastication forces, both materials appeared to be suitable for the predictable use of posterior partial crowns.


    • 1 January 2007
      • Vol. 117  (5) , 474-82

    [Marginal accuracy of pressed ceramic full veneers with different preparation techniques before and after simulated jaw movement].

    by Christian F J Stappert, Jan Derks, Thomas Gerds, Jörg R Strub

    This in-vitro study investigated the marginal accuracy of press-ceramic full veneers with different preparation designs. Measurements of the marginal gap were performed after adhesive cementation as well as after mouth motion fatigue of the veneers. 64 extracted human maxillary central incisors were divided into four groups of 16 specimens each and prepared as follows: Group SZ = enamel (S) restricted 0.5 mm deep preparation with a high palatal shoulder (contact point on tooth structure [Z]), Group SK = enamel (S) restricted 0.5 mm deep preparation with a low palatal shoulder (contact point on ceramic [K]), Group DZ = dentine (D) included 1 mm deep preparation with a high palatal shoulder (contact point on tooth structure), Group DK = dentine included 1 mm deep preparation with a low palatal shoulder (contact point on ceramic). IPS e.max Press ceramic was used to fabricate the full veneers. Restorations were adhesively luted with a dual-polymerizing resin-cementVariolinkII* (*Ivoclar-Vivadent AG). Specimens underwent fatigue in a masticatory simulator (1.2 million cycles; 49 N), including thermal cycling (5500; 5 degrees C/55 degrees C). Computer-aided measurements of the marginal accuracy using stereo-light-microscopy (200x) resulted in mean values of 56 pm to 64 pm after adhesive luting. Masticatory simulation did not cause significant changes of mean marginal accuracies. In comparison, neither the adhesive cementation of the veneers to mainly enamel or dentin nor the position of load application did demonstrate a significant influence on the marginal fit in the given investigation period. Based on the used measurement methods, mouth motion fatigue of the restorations did not demonstrate a significant change of marginal fit.

  • Partial coverage restoration systems on molars – comparison of failure load after exposure to a mastication simulator

    by C. F. J. Stappert, P. C. Guess, S. Chitmongkolsuk, T. Gerds, J. R. Strub

    This in vitro study evaluated the failure load of partial coverage restorations (PCR) made of various materials cemented on natural molars after exposure to the mastication simulator. Sixty-four maxillary molars were divided into four groups of 16 test specimens each. The specimens in one group remained unprepared (group NP); the teeth in the other groups were prepared equally according to standardized guidelines and restored with the following PCR: Group GO (Gold-Pontor-MPF; Metaux Precieux SA, Metalor, Neuchatel, Switzerland), group TA (Targis; Ivoclar Vivadent AG, Schaan, Liechtenstein) and group EM (IPS-Empress; Ivoclar Vivadent AG). The restorations in group GO were cemented conventionally, while those in groups TA and EM were luted adhesively. Groups NP and GO served as control groups. All test specimens were subjected to 1.2 million cycles (F = 49 N) in a mastication simulator. Subsequently, all test specimens were loaded occlusally until fracture occurred using an universal testing machine. All specimens withstood the masticating simulation. The median (IQR = x(0.25)-x(0.75)) failure loads were as follows: group NP: 1960.3(1480.5-2227.5) N, group TA: 1478.6(1293.4-1856.7) N and group EM: 1400.1(1043.1-1721.6) N. All test specimens of group GO achieved fracture strength values which exceeded a fracture load of 5500 N. The values of group GO were statistically significantly higher than those of groups NP, TA and EM (P < 0.00001). Furthermore, the results of group NP were significantly higher (P = 0.0226) than those of group EM. The results of groups NP and TA (P = 0.2022) as well as of groups TA and EM (P = 0.5340) did not differ significantly. The median values of all PCR systems obtained were within the limits of clinical acceptance. Long-term clinical investigations which take additional parameters into consideration are required before the composite-based Targis(R) (Ivoclar Vivadent AG) material can be recommended for indirect PCR.