Olga I. Ornatsky
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Olga I. Ornatsky has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Mitchell A. Winnik
2 shared publicationsScott D. Tanner
Chemistry Department, University of Toronto, 80 St. George Street, Toronto, Ontario, Canada M5S 3H6
2 shared publicationsVladimir Baranov
2 shared publicationsD. R. Bandura
Department of Chemistry, University of Toronto, Toronto, Canada, and Lehrstuhl für Analytische Chemie, Ruhr-Universität Bochum, D-44780 Bochum, Germany
1 shared publicationD.R. Bandura
1 shared publicationDmitry Bandura
1 shared publication
Latest Publications
- Top Cited Papers
- 1 September 2010
- Published by Elsevier in Journal of Immunological Methods
- Vol. 361 (1-2) , 1-20
Highly multiparametric analysis by mass cytometry
- 1 September 2010
- Published by Elsevier in Journal of Immunological Methods
- Vol. 361 (1-2) , 1-20
Top Cited PapersHighly multiparametric analysis by mass cytometry
- 1 July 2008
- Published by Elsevier in Journal of Immunological Methods
- Vol. 336 (1) , 56-63
Element-tagged immunoassay with ICP-MS detection: Evaluation and comparison to conventional immunoassays
- 1 July 2008
- Published by Elsevier in Journal of Immunological Methods
- Vol. 336 (1) , 56-63
Element-tagged immunoassay with ICP-MS detection: Evaluation and comparison to conventional immunoassays
- 5 March 2008
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (7) , 2539-2547
Study of Cell Antigens and Intracellular DNA by Identification of Element-Containing Labels and Metallointercalators Using Inductively Coupled Plasma Mass Spectrometry
The enumeration of absolute cell numbers and cell proliferation in clinical samples is important for diagnostic and research purposes. Detection of cellular DNA with fluorescent dyes is the most commonly used approach for cell enumeration in cytometry. Inductively coupled plasma mass spectrometry (ICPMS) has been recently introduced to the field of protein and cell surface antigen identification via ICPMS-linked immunoassays using element-labeled affinity reagents such as gold and lanthanide-conjugated antibodies. In the present work, we describe novel methods for using metallointercalators that irreversibly bind DNA and low concentrations of rare earth metals added to cell growth media for rapid and sensitive measurement of cell numbers by mass spectrometry. We show that Ir- and Rh-containing metallointercalators are useful reagents for labeling cells and normalizing signals when studying antigen expression on different types and numbers of cells. Results are presented for solution analysis performed by conventional ICPMS and compared to measurements obtained on the novel flow cytometer mass spectrometer (FC−MS) instrument, designed to analyze multiple antigens and DNA simultaneously in single cells.
- 5 March 2008
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (7) , 2539-2547
Study of Cell Antigens and Intracellular DNA by Identification of Element-Containing Labels and Metallointercalators Using Inductively Coupled Plasma Mass Spectrometry
The enumeration of absolute cell numbers and cell proliferation in clinical samples is important for diagnostic and research purposes. Detection of cellular DNA with fluorescent dyes is the most commonly used approach for cell enumeration in cytometry. Inductively coupled plasma mass spectrometry (ICPMS) has been recently introduced to the field of protein and cell surface antigen identification via ICPMS-linked immunoassays using element-labeled affinity reagents such as gold and lanthanide-conjugated antibodies. In the present work, we describe novel methods for using metallointercalators that irreversibly bind DNA and low concentrations of rare earth metals added to cell growth media for rapid and sensitive measurement of cell numbers by mass spectrometry. We show that Ir- and Rh-containing metallointercalators are useful reagents for labeling cells and normalizing signals when studying antigen expression on different types and numbers of cells. Results are presented for solution analysis performed by conventional ICPMS and compared to measurements obtained on the novel flow cytometer mass spectrometer (FC−MS) instrument, designed to analyze multiple antigens and DNA simultaneously in single cells.
- 14 September 2006
- Vol. 1, 1-9
Messenger RNA Detection in Leukemia Cell lines by Novel Metal-Tagged in situ Hybridization using Inductively Coupled Plasma Mass Spectrometry
Conventional gene expression profiling relies on using fluorescent detection of hybridized probes. Physical characteristics of fluorophores impose limitations on achieving a highly multiplex gene analysis of single cells. Our work demonstrates the feasibility of using metal-tagged in situ hybridization for mRNA detection by inductively coupled plasma mass spectrometry (ICP-MS). ICP-MS as an analytical detector has a number of unique and relevant properties: 1) metals and their stable isotopes generate non-overlapping distinct signals that can be detected simultaneously; 2) these signals can be measured over a wide dynamic range; 3) ICP-MS is quantitative and very sensitive. We used commercial antibodies conjugated to europium (Eu) and gold together with biotinylated oligonucleotide probes reacted with terbium-labeled streptavidin to demonstrate simultaneous mRNA and protein detection by ICP-MS in leukemia cells.
- 14 September 2006
- Vol. 1, 1-9
Messenger RNA Detection in Leukemia Cell lines by Novel Metal-Tagged in situ Hybridization using Inductively Coupled Plasma Mass Spectrometry
Conventional gene expression profiling relies on using fluorescent detection of hybridized probes. Physical characteristics of fluorophores impose limitations on achieving a highly multiplex gene analysis of single cells. Our work demonstrates the feasibility of using metal-tagged in situ hybridization for mRNA detection by inductively coupled plasma mass spectrometry (ICP-MS). ICP-MS as an analytical detector has a number of unique and relevant properties: 1) metals and their stable isotopes generate non-overlapping distinct signals that can be detected simultaneously; 2) these signals can be measured over a wide dynamic range; 3) ICP-MS is quantitative and very sensitive. We used commercial antibodies conjugated to europium (Eu) and gold together with biotinylated oligonucleotide probes reacted with terbium-labeled streptavidin to demonstrate simultaneous mRNA and protein detection by ICP-MS in leukemia cells.
- 1 January 2006
- Published by Elsevier in Journal of Immunological Methods
- Vol. 308 (1-2) , 68-76
Multiple cellular antigen detection by ICP-MS
- 1 January 2006
- Published by Elsevier in Journal of Immunological Methods
- Vol. 308 (1-2) , 68-76
Multiple cellular antigen detection by ICP-MS
- 16 December 2003
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 19 (1) , 96-100
Characterization of phosphorus content of biological samples by ICP-DRC-MS: potential tool for cancer research
Phosphorus and sulfur are detected as phosphorus oxide and sulfur oxide ions (PO+ and SO+), produced by oxidation reactions with O2 performed in the reaction cell of the inductively coupled plasma dynamic reaction cell mass spectrometer (ICP-DRC-MS), at sub-ng mL−1 detection limits. This allows pM mL−1 detection of phospho-proteins, with S used as an internal standard (see ref. 9). The method was applied to digests (in HCl) of in-vitro tyrosine kinase assays, both as an evaluation of kinase autophosphorylation and phosphorylation of substrate. Detecting the phosphorus/sulfur ratio (via measured PO+/SO+) in cell cultures is shown to provide a distinguishable difference between malignant cell lines and primary cultures. The PO+/SO+ ratio for human colorectal adenocarcinoma (CRC) tissue samples compared with matched normal (N) tissue samples from the same patients is shown to be higher, at (PO+/SO+)CRC/(PO+/SO+)N = 1.75 ± 0.18 (n = 4). Samples used in this analysis were of needle biopsy amounts (0.2–0.5 mg), with a greater than 70% tumor burden in CRC. The phospho-protein phosvitin is detected directly from dried one-dimensional polyacrylamide gels using laser ablation ICP-MS by detecting phosphorus at sub-nM amounts. The phosphorus detection limit for direct ablation, assessed from ablating gel doped with P and blank gel, is 0.6 µg g−1 in gel. Direct detection of sulfur from the gels is obscured by the high sulfur background for the blank gels, which is attributed to the sulfur-containing catalysts used in polymerization and to sodium dodecyl sulfate (SDS) used for protein denaturing.
- 16 December 2003
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 19 (1) , 96-100
Characterization of phosphorus content of biological samples by ICP-DRC-MS: potential tool for cancer research
Phosphorus and sulfur are detected as phosphorus oxide and sulfur oxide ions (PO+ and SO+), produced by oxidation reactions with O2 performed in the reaction cell of the inductively coupled plasma dynamic reaction cell mass spectrometer (ICP-DRC-MS), at sub-ng mL−1 detection limits. This allows pM mL−1 detection of phospho-proteins, with S used as an internal standard (see ref. 9). The method was applied to digests (in HCl) of in-vitro tyrosine kinase assays, both as an evaluation of kinase autophosphorylation and phosphorylation of substrate. Detecting the phosphorus/sulfur ratio (via measured PO+/SO+) in cell cultures is shown to provide a distinguishable difference between malignant cell lines and primary cultures. The PO+/SO+ ratio for human colorectal adenocarcinoma (CRC) tissue samples compared with matched normal (N) tissue samples from the same patients is shown to be higher, at (PO+/SO+)CRC/(PO+/SO+)N = 1.75 ± 0.18 (n = 4). Samples used in this analysis were of needle biopsy amounts (0.2–0.5 mg), with a greater than 70% tumor burden in CRC. The phospho-protein phosvitin is detected directly from dried one-dimensional polyacrylamide gels using laser ablation ICP-MS by detecting phosphorus at sub-nM amounts. The phosphorus detection limit for direct ablation, assessed from ablating gel doped with P and blank gel, is 0.6 µg g−1 in gel. Direct detection of sulfur from the gels is obscured by the high sulfur background for the blank gels, which is attributed to the sulfur-containing catalysts used in polymerization and to sodium dodecyl sulfate (SDS) used for protein denaturing.