Masaru Ishii
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Masaru Ishii has a total of 210 co-authors. Here are the top co-authors by number of shared publications:
- Gregory D. Hager
The Department of Computer Science, Johns Hopkins University, Baltimore, USA
5 shared publications - Russell H. Taylor
Department of Computer Science, Johns Hopkins University
5 shared publications - Gregory D. Hager
Johns Hopkins University, Baltimore, MD, 21211, USA
4 shared publications - David A. Lipson
GSK, Collegeville, PA, USA
3 shared publications Gary Gallia
3 shared publications- Gary L. Gallia
Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland
3 shared publications
Latest Publications
- Open Access
Outcomes for Sinonasal Undifferentiated Carcinoma (SNUC): An International Multi-Center Retrospective Cohort Study
Background: Sinonasal undifferentiated carcinoma (SNUC) is an extremely rare, high-grade, and aggressive tumor of the sinonasal tract. Due to the rarity of this malignancy, current treatment guidelines are based on small and often/mainly single-center retrospective datasets. In the absence of a universally accepted standard of care for SNUC, treatment approaches vary across countries and institutions, reflecting real-world clinical practice. The primary aim of this study was to describe real-world treatment and outcomes for patients with confirmed SNUC. Methods: This was an international, multi-center, retrospective, observational cohort study that pooled patients into the largest SNUC dataset to date. Fifteen centers were enrolled to contribute data, including seven from Europe, four from the United States, three from the United Kingdom, and one from Canada. In the absence of a universally accepted standard of care for SNUC, treatment approaches varied across countries and institutions, reflecting real-world clinical practice. Patients included were those with histologically confirmed SNUC who were treated between 1997 and 2021. Results: This study yielded 485 patients treated for SNUC. The median age at diagnosis was 55.6 years (IQR: 44.5–67.6), and 63.7% were male. Most cases presented at advanced stages, with 70.8% as T4a or T4b. Overall survival (OS) outcomes were available for 412 patients, with a median follow-up of 26.0 months. The 5- and 10-year OS were 47.2% (95% CI: 40.8–53.3%) and 39.6% (95% CI: 32.5–46.6%), respectively. Advanced age, dichotomized T-stage (T4a/b vs. T1–3), M-stage, and orbital involvement were significant poor prognostic factors on univariable analysis (p’s < 0.01). On multivariable analysis, orbital involvement (HR: 2.73, 95% CI: 1.42–5.27, p = 0.003) and distance metastasis stage (HR: 3.00, 95% CI: 1.25–7.21, p = 0.014) were both independently associated with worse OS. Conclusions: This observational study presents the largest multi-center cohort analysis of SNUC to date, providing new insights into prognostic factors for a rare cancer treated at global centers of excellence. Orbital involvement and the presence of metastases are candidate independent risk factors associated with poorer OS.
Open AccessOutcomes for Sinonasal Undifferentiated Carcinoma (SNUC): An International Multi-Center Retrospective Cohort Study
Background: Sinonasal undifferentiated carcinoma (SNUC) is an extremely rare, high-grade, and aggressive tumor of the sinonasal tract. Due to the rarity of this malignancy, current treatment guidelines are based on small and often/mainly single-center retrospective datasets. In the absence of a universally accepted standard of care for SNUC, treatment approaches vary across countries and institutions, reflecting real-world clinical practice. The primary aim of this study was to describe real-world treatment and outcomes for patients with confirmed SNUC. Methods: This was an international, multi-center, retrospective, observational cohort study that pooled patients into the largest SNUC dataset to date. Fifteen centers were enrolled to contribute data, including seven from Europe, four from the United States, three from the United Kingdom, and one from Canada. In the absence of a universally accepted standard of care for SNUC, treatment approaches varied across countries and institutions, reflecting real-world clinical practice. Patients included were those with histologically confirmed SNUC who were treated between 1997 and 2021. Results: This study yielded 485 patients treated for SNUC. The median age at diagnosis was 55.6 years (IQR: 44.5–67.6), and 63.7% were male. Most cases presented at advanced stages, with 70.8% as T4a or T4b. Overall survival (OS) outcomes were available for 412 patients, with a median follow-up of 26.0 months. The 5- and 10-year OS were 47.2% (95% CI: 40.8–53.3%) and 39.6% (95% CI: 32.5–46.6%), respectively. Advanced age, dichotomized T-stage (T4a/b vs. T1–3), M-stage, and orbital involvement were significant poor prognostic factors on univariable analysis (p’s < 0.01). On multivariable analysis, orbital involvement (HR: 2.73, 95% CI: 1.42–5.27, p = 0.003) and distance metastasis stage (HR: 3.00, 95% CI: 1.25–7.21, p = 0.014) were both independently associated with worse OS. Conclusions: This observational study presents the largest multi-center cohort analysis of SNUC to date, providing new insights into prognostic factors for a rare cancer treated at global centers of excellence. Orbital involvement and the presence of metastases are candidate independent risk factors associated with poorer OS.
- Open Access
Did you just see that? Arbitrary view synthesis for egocentric replay of operating room workflows from ambient sensors
Observing surgical practice has historically relied on fixed vantage points or recollections, leaving the egocentric visual perspectives that guide clinical decisions undocumented. Fixed-camera video can capture surgical workflows at the room-scale, but cannot reconstruct what each team member actually saw. Thus, these videos only provide limited insights into how decisions that affect surgical safety, training, and workflow optimization are made. Here we introduce EgoSurg, the first framework to reconstruct the dynamic, egocentric replays for any operating room (OR) staff directly from wall-mounted fixed-camera video, and thus, without intervention to clinical workflow. EgoSurg couples geometry-driven neural rendering with diffusion-based view enhancement, enabling high-visual fidelity synthesis of arbitrary and egocentric viewpoints at any moment. In evaluation across multi-site surgical cases and controlled studies, EgoSurg reconstructs person-specific visual fields and arbitrary viewpoints with high visual quality and fidelity. By transforming existing OR camera infrastructure into a navigable dynamic 3D record, EgoSurg establishes a new foundation for immersive surgical data science, enabling surgical practice to be visualized, experienced, and analyzed from every angle.
Open AccessDid you just see that? Arbitrary view synthesis for egocentric replay of operating room workflows from ambient sensors
Observing surgical practice has historically relied on fixed vantage points or recollections, leaving the egocentric visual perspectives that guide clinical decisions undocumented. Fixed-camera video can capture surgical workflows at the room-scale, but cannot reconstruct what each team member actually saw. Thus, these videos only provide limited insights into how decisions that affect surgical safety, training, and workflow optimization are made. Here we introduce EgoSurg, the first framework to reconstruct the dynamic, egocentric replays for any operating room (OR) staff directly from wall-mounted fixed-camera video, and thus, without intervention to clinical workflow. EgoSurg couples geometry-driven neural rendering with diffusion-based view enhancement, enabling high-visual fidelity synthesis of arbitrary and egocentric viewpoints at any moment. In evaluation across multi-site surgical cases and controlled studies, EgoSurg reconstructs person-specific visual fields and arbitrary viewpoints with high visual quality and fidelity. By transforming existing OR camera infrastructure into a navigable dynamic 3D record, EgoSurg establishes a new foundation for immersive surgical data science, enabling surgical practice to be visualized, experienced, and analyzed from every angle.
- 24 April 2025
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 20 (10) , 2087-2093
The quiet eye phenomenon in minimally invasive surgery
Purpose The quiet eye (QE) behavior is a gaze behavior that has been extensively studied in sports training and has been associated with higher level of expertise in multiple sports. In this paper, we report our observations of this gaze behavior in two minimally invasive surgery settings and we report how this behavior changes based on task success and the surgeon’s expertise level. Methods We investigated the QE behavior in two independently collected data sets in a sinus surgery setting and a robotic surgery setting. The sinus surgery data set was used to study how the QE behavior changes in successful and unsuccessful tasks. The robotic surgery data set was used to study how the QE behavior changes based on the surgeon’s expertise level. Results Using the sinus surgery data set, our results show that the QE behavior is more likely to occur and that its duration is significantly longer, in successful tasks, compared with unsuccessful ones. Using the robotic surgery data set, our results show similar trends in tasks performed by experienced surgeons, compared with less experienced ones. Conclusion The results of our study open the door to use the QE behavior in training and skill assessment in the explored minimally invasive surgery settings. Training novices to adopt the QE behavior can potentially improve their motor skill learning, replicating the success of doing so in sports training. In addition, the well-defined characteristics of the QE behavior can provide an explainable way to distinguish between different skill levels in minimally invasive surgery.
- 24 April 2025
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 20 (10) , 2087-2093
The quiet eye phenomenon in minimally invasive surgery
Purpose The quiet eye (QE) behavior is a gaze behavior that has been extensively studied in sports training and has been associated with higher level of expertise in multiple sports. In this paper, we report our observations of this gaze behavior in two minimally invasive surgery settings and we report how this behavior changes based on task success and the surgeon’s expertise level. Methods We investigated the QE behavior in two independently collected data sets in a sinus surgery setting and a robotic surgery setting. The sinus surgery data set was used to study how the QE behavior changes in successful and unsuccessful tasks. The robotic surgery data set was used to study how the QE behavior changes based on the surgeon’s expertise level. Results Using the sinus surgery data set, our results show that the QE behavior is more likely to occur and that its duration is significantly longer, in successful tasks, compared with unsuccessful ones. Using the robotic surgery data set, our results show similar trends in tasks performed by experienced surgeons, compared with less experienced ones. Conclusion The results of our study open the door to use the QE behavior in training and skill assessment in the explored minimally invasive surgery settings. Training novices to adopt the QE behavior can potentially improve their motor skill learning, replicating the success of doing so in sports training. In addition, the well-defined characteristics of the QE behavior can provide an explainable way to distinguish between different skill levels in minimally invasive surgery.
- Open Access
A Quantitative Evaluation of Dense 3D Reconstruction of Sinus Anatomy from Monocular Endoscopic Video
Generating accurate 3D reconstructions from endoscopic video is a promising avenue for longitudinal radiation-free analysis of sinus anatomy and surgical outcomes. Several methods for monocular reconstruction have been proposed, yielding visually pleasant 3D anatomical structures by retrieving relative camera poses with structure-from-motion-type algorithms and fusion of monocular depth estimates. However, due to the complex properties of the underlying algorithms and endoscopic scenes, the reconstruction pipeline may perform poorly or fail unexpectedly. Further, acquiring medical data conveys additional challenges, presenting difficulties in quantitatively benchmarking these models, understanding failure cases, and identifying critical components that contribute to their precision. In this work, we perform a quantitative analysis of a self-supervised approach for sinus reconstruction using endoscopic sequences paired with optical tracking and high-resolution computed tomography acquired from nine ex-vivo specimens. Our results show that the generated reconstructions are in high agreement with the anatomy, yielding an average point-to-mesh error of 0.91 mm between reconstructions and CT segmentations. However, in a point-to-point matching scenario, relevant for endoscope tracking and navigation, we found average target registration errors of 6.58 mm. We identified that pose and depth estimation inaccuracies contribute equally to this error and that locally consistent sequences with shorter trajectories generate more accurate reconstructions. These results suggest that achieving global consistency between relative camera poses and estimated depths with the anatomy is essential. In doing so, we can ensure proper synergy between all components of the pipeline for improved reconstructions that will facilitate clinical application of this innovative technology.
Open AccessA Quantitative Evaluation of Dense 3D Reconstruction of Sinus Anatomy from Monocular Endoscopic Video
Generating accurate 3D reconstructions from endoscopic video is a promising avenue for longitudinal radiation-free analysis of sinus anatomy and surgical outcomes. Several methods for monocular reconstruction have been proposed, yielding visually pleasant 3D anatomical structures by retrieving relative camera poses with structure-from-motion-type algorithms and fusion of monocular depth estimates. However, due to the complex properties of the underlying algorithms and endoscopic scenes, the reconstruction pipeline may perform poorly or fail unexpectedly. Further, acquiring medical data conveys additional challenges, presenting difficulties in quantitatively benchmarking these models, understanding failure cases, and identifying critical components that contribute to their precision. In this work, we perform a quantitative analysis of a self-supervised approach for sinus reconstruction using endoscopic sequences paired with optical tracking and high-resolution computed tomography acquired from nine ex-vivo specimens. Our results show that the generated reconstructions are in high agreement with the anatomy, yielding an average point-to-mesh error of 0.91 mm between reconstructions and CT segmentations. However, in a point-to-point matching scenario, relevant for endoscope tracking and navigation, we found average target registration errors of 6.58 mm. We identified that pose and depth estimation inaccuracies contribute equally to this error and that locally consistent sequences with shorter trajectories generate more accurate reconstructions. These results suggest that achieving global consistency between relative camera poses and estimated depths with the anatomy is essential. In doing so, we can ensure proper synergy between all components of the pipeline for improved reconstructions that will facilitate clinical application of this innovative technology.
- 11 April 2022
- Published by SAGE Publications in Facial Plastic Surgery & Aesthetic Medicine
- Vol. 24 (6) , 436-442
Visual Attention to Facial Defects Predicts Willingness to Pay for Reconstructive Surgery
Background: The relationship between the value of reconstructive surgery and the visual attention drawn by facial deformity has not been studied. Objectives: We hypothesized that willingness to pay (WTP) for reconstructive surgery would increase as visual attention to deformity increased in a Mohs defect eye-tracking model. Methods: We conducted a randomized observational study. Eighty casual observers participated in timed eye-tracking trials utilizing preoperative and postoperative photographs from 32 patients with facial Mohs defects. Fixation on each defect was quantified in milliseconds. For each photograph, casual observers reported how much they would be willing to pay for a perfect reconstruction and rated defect severity and patient attractiveness. The associations between defect fixation time and WTP, attractiveness, and severity were modeled using a multivariate mixed-effects model. Results: Increased defect fixation time was associated with increased WTP (regression coefficient = 0.332651, p < 0.001), decreased attractiveness (regression coefficient = −0.221779, p < 0.001), and increased severity (regression coefficient = 0.363111, p < 0.001). As defect fixation time increased, WTP increased exponentially. Conclusions: Observer WTP for facial reconstruction increases exponentially as defects become more distracting. These findings justify the dedication of health care resources to reconstructive procedures that decrease attentional distraction to the greatest extent possible.
- 11 April 2022
- Published by SAGE Publications in Facial Plastic Surgery & Aesthetic Medicine
- Vol. 24 (6) , 436-442
Visual Attention to Facial Defects Predicts Willingness to Pay for Reconstructive Surgery
Background: The relationship between the value of reconstructive surgery and the visual attention drawn by facial deformity has not been studied. Objectives: We hypothesized that willingness to pay (WTP) for reconstructive surgery would increase as visual attention to deformity increased in a Mohs defect eye-tracking model. Methods: We conducted a randomized observational study. Eighty casual observers participated in timed eye-tracking trials utilizing preoperative and postoperative photographs from 32 patients with facial Mohs defects. Fixation on each defect was quantified in milliseconds. For each photograph, casual observers reported how much they would be willing to pay for a perfect reconstruction and rated defect severity and patient attractiveness. The associations between defect fixation time and WTP, attractiveness, and severity were modeled using a multivariate mixed-effects model. Results: Increased defect fixation time was associated with increased WTP (regression coefficient = 0.332651, p < 0.001), decreased attractiveness (regression coefficient = −0.221779, p < 0.001), and increased severity (regression coefficient = 0.363111, p < 0.001). As defect fixation time increased, WTP increased exponentially. Conclusions: Observer WTP for facial reconstruction increases exponentially as defects become more distracting. These findings justify the dedication of health care resources to reconstructive procedures that decrease attentional distraction to the greatest extent possible.
- Open Access
- 31 March 2022
- Published by Wiley in The Laryngoscope
- Vol. 133 (3) , 500-505
Eye Tracking and Motion Data Predict Endoscopic Sinus Surgery Skill
Objective: Endoscopic surgery has a considerable learning curve due to dissociation of the visual‐motor axes, coupled with decreased tactile feedback and mobility. In particular, endoscopic sinus surgery (ESS) lacks objective skill assessment metrics to provide specific feedback to trainees. This study aims to identify summary metrics from eye tracking, endoscope motion, and tool motion to objectively assess surgeons' ESS skill.Methods: In this cross‐sectional study, expert and novice surgeons performed ESS tasks of inserting an endoscope and tool into a cadaveric nose, touching an anatomical landmark, and withdrawing the endoscope and tool out of the nose. Tool and endoscope motion were collected using an electromagnetic tracker, and eye gaze was tracked using an infrared camera. Three expert surgeons provided binary assessments of low/high skill. 20 summary statistics were calculated for eye, tool, and endoscope motion and used in logistic regression models to predict surgical skill.Results: 14 metrics (10 eye gaze, 2 tool motion, and 2 endoscope motion) were significantly different between surgeons with low and high skill. Models to predict skill for 6/9 ESS tasks had an AUC >0.95. A combined model of all tasks (AUC 0.95, PPV 0.93, NPV 0.89) included metrics from eye tracking data and endoscope motion, indicating that these metrics are transferable across tasks.Conclusions: Eye gaze, endoscope, and tool motion data can provide an objective and accurate measurement of ESS surgical performance. Incorporation of these algorithmic techniques intraoperatively could allow for automated skill assessment for trainees learning endoscopic surgery.Level of Evidence: N/A Laryngoscope, 133:500–505, 2023
- 31 March 2022
- Published by Wiley in The Laryngoscope
- Vol. 133 (3) , 500-505
Open AccessEye Tracking and Motion Data Predict Endoscopic Sinus Surgery Skill
Objective: Endoscopic surgery has a considerable learning curve due to dissociation of the visual‐motor axes, coupled with decreased tactile feedback and mobility. In particular, endoscopic sinus surgery (ESS) lacks objective skill assessment metrics to provide specific feedback to trainees. This study aims to identify summary metrics from eye tracking, endoscope motion, and tool motion to objectively assess surgeons' ESS skill.Methods: In this cross‐sectional study, expert and novice surgeons performed ESS tasks of inserting an endoscope and tool into a cadaveric nose, touching an anatomical landmark, and withdrawing the endoscope and tool out of the nose. Tool and endoscope motion were collected using an electromagnetic tracker, and eye gaze was tracked using an infrared camera. Three expert surgeons provided binary assessments of low/high skill. 20 summary statistics were calculated for eye, tool, and endoscope motion and used in logistic regression models to predict surgical skill.Results: 14 metrics (10 eye gaze, 2 tool motion, and 2 endoscope motion) were significantly different between surgeons with low and high skill. Models to predict skill for 6/9 ESS tasks had an AUC >0.95. A combined model of all tasks (AUC 0.95, PPV 0.93, NPV 0.89) included metrics from eye tracking data and endoscope motion, indicating that these metrics are transferable across tasks.Conclusions: Eye gaze, endoscope, and tool motion data can provide an objective and accurate measurement of ESS surgical performance. Incorporation of these algorithmic techniques intraoperatively could allow for automated skill assessment for trainees learning endoscopic surgery.Level of Evidence: N/A Laryngoscope, 133:500–505, 2023
- 15 November 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 8 (06) , 065001-13
Reconstructing the nasal septum from instrument motion during septoplasty surgery
Purpose: Surgery involves modifying anatomy to achieve a goal. Reconstructing anatomy can facilitate surgical care through surgical planning, real-time decision support, or anticipating outcomes. Tool motion is a rich source of data that can be used to quantify anatomy. Our work develops and validates a method for reconstructing the nasal septum from unstructured motion of the Cottle elevator during the elevation phase of septoplasty surgery, without need to explicitly delineate the surface of the septum. Approach: The proposed method uses iterative closest point registration to initially register a template septum to the tool motion. Subsequently, statistical shape modeling with iterative most likely oriented point registration is used to fit the reconstructed septum to Cottle tip position and orientation during flap elevation. Regularization of the shape model and transformation is incorporated. The proposed methods were validated on 10 septoplasty surgeries performed on cadavers by operators of varying experience level. Preoperative CT images of the cadaver septums were segmented as ground truth. Results: We estimated reconstruction error as the difference between the projections of the Cottle tip onto the surface of the reconstructed septum and the ground-truth septum segmented from the CT image. We found translational differences of 2.74 ( 2.06 − 2.81 ) mm and a rotational differences of 8.95 ( 7.11 − 10.55 ) deg between the reconstructed septum and the ground-truth septum [median (interquartile range)], given the optimal regularization parameters. Conclusions: Accurate reconstruction of the nasal septum can be achieved from tool tracking data during septoplasty surgery on cadavers. This enables understanding of the septal anatomy without need for traditional medical imaging. This result may be used to facilitate surgical planning, intraoperative care, or skills assessment.
- 15 November 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 8 (06) , 065001-13
Reconstructing the nasal septum from instrument motion during septoplasty surgery
Purpose: Surgery involves modifying anatomy to achieve a goal. Reconstructing anatomy can facilitate surgical care through surgical planning, real-time decision support, or anticipating outcomes. Tool motion is a rich source of data that can be used to quantify anatomy. Our work develops and validates a method for reconstructing the nasal septum from unstructured motion of the Cottle elevator during the elevation phase of septoplasty surgery, without need to explicitly delineate the surface of the septum. Approach: The proposed method uses iterative closest point registration to initially register a template septum to the tool motion. Subsequently, statistical shape modeling with iterative most likely oriented point registration is used to fit the reconstructed septum to Cottle tip position and orientation during flap elevation. Regularization of the shape model and transformation is incorporated. The proposed methods were validated on 10 septoplasty surgeries performed on cadavers by operators of varying experience level. Preoperative CT images of the cadaver septums were segmented as ground truth. Results: We estimated reconstruction error as the difference between the projections of the Cottle tip onto the surface of the reconstructed septum and the ground-truth septum segmented from the CT image. We found translational differences of 2.74 ( 2.06 − 2.81 ) mm and a rotational differences of 8.95 ( 7.11 − 10.55 ) deg between the reconstructed septum and the ground-truth septum [median (interquartile range)], given the optimal regularization parameters. Conclusions: Accurate reconstruction of the nasal septum can be achieved from tool tracking data during septoplasty surgery on cadavers. This enables understanding of the septal anatomy without need for traditional medical imaging. This result may be used to facilitate surgical planning, intraoperative care, or skills assessment.
- 3 September 2021
- Published by SAGE Publications in Facial Plastic Surgery & Aesthetic Medicine
- Vol. 23 (5) , 393-394
Selfies and Surgery: How Photo Editing Impacts Perceptions of Facial Plastic Surgery Capabilities
Facial Plastic Surgery & Aesthetic Medicine
- 3 September 2021
- Published by SAGE Publications in Facial Plastic Surgery & Aesthetic Medicine
- Vol. 23 (5) , 393-394
Selfies and Surgery: How Photo Editing Impacts Perceptions of Facial Plastic Surgery Capabilities
Facial Plastic Surgery & Aesthetic Medicine
- Open Access
Dense Depth Estimation in Monocular Endoscopy with Self-supervised Learning Methods
We present a self-supervised approach to training convolutional neural networks for dense depth estimation from monocular endoscopy data without a priori modeling of anatomy or shading. Our method only requires monocular endoscopic videos and a multi-view stereo method, e.g., structure from motion, to supervise learning in a sparse manner. Consequently, our method requires neither manual labeling nor patient computed tomography (CT) scan in the training and application phases. In a cross-patient experiment using CT scans as groundtruth, the proposed method achieved submillimeter mean residual error. In a comparison study to recent self-supervised depth estimation methods designed for natural video on in vivo sinus endoscopy data, we demonstrate that the proposed approach outperforms the previous methods by a large margin. The source code for this work is publicly available online at https://github.com/lppllppl920/EndoscopyDepthEstimation-Pytorch.
Open AccessDense Depth Estimation in Monocular Endoscopy with Self-supervised Learning Methods
We present a self-supervised approach to training convolutional neural networks for dense depth estimation from monocular endoscopy data without a priori modeling of anatomy or shading. Our method only requires monocular endoscopic videos and a multi-view stereo method, e.g., structure from motion, to supervise learning in a sparse manner. Consequently, our method requires neither manual labeling nor patient computed tomography (CT) scan in the training and application phases. In a cross-patient experiment using CT scans as groundtruth, the proposed method achieved submillimeter mean residual error. In a comparison study to recent self-supervised depth estimation methods designed for natural video on in vivo sinus endoscopy data, we demonstrate that the proposed approach outperforms the previous methods by a large margin. The source code for this work is publicly available online at https://github.com/lppllppl920/EndoscopyDepthEstimation-Pytorch.
- 27 March 2017
- Published by Wiley in The Laryngoscope
- Vol. 127 (8) , 1735-1741
Assessment of frozen section margin analysis during olfactory neuroblastoma surgery
Objectives: 1) assess the performance of the intraoperative frozen section procedure to correctly classify biopsies obtained during olfactory neuroblastoma (ONB) surgery; 2) define the relationship between posttest probabilities and pretest probabilities from frozen section analysis; and 3) review incorrectly classified specimens.Study Design: Study of diagnostic accuracy.Methods: We searched our institution's pathology database for patients who had ONB surgery between January 1, 2000 and November 16, 2012. We only included patients who had a definitive diagnosis of ONB prior to surgery and frozen sections obtained during surgery. All frozen sections in this study had corresponding permanent sections available to serve as a gold standard. This database was analyzed to obtain classification statistics. The confidence intervals for classification performance were obtained using the bootstrap sampling method. Confidence intervals for posttest probability curves were derived using the Taylor series expansion. Finally, we obtained and reviewed the slides from ambiguous or incorrect reads.Results: A total of 459 specimens from 33 patients were analyzed. We found the following performance characteristics: sensitivity: 0.89 (0.81, 0.94); specificity: 0.96 (0.94, 0.98); accuracy: 0.95 (0.92, 0.96); likelihood ratio positive: 24.4 (14.5, 44.1); prevalence: 0.20 (0.17, 0.25); positive predictive value: 0.86 (0.78, 0.92); and negative predictive value: 0.97 (0.95, 0.99). Histopathologic review revealed that crush artifacts and inadequate specimen size were major sources of incorrect reads.Conclusion: We found frozen section assessment of ONB specimens to be an excellent tool for the assessment of intraoperative margins.Level of Evidence: NA. Laryngoscope, 127:1735–1741, 2017
- 27 March 2017
- Published by Wiley in The Laryngoscope
- Vol. 127 (8) , 1735-1741
Assessment of frozen section margin analysis during olfactory neuroblastoma surgery
Objectives: 1) assess the performance of the intraoperative frozen section procedure to correctly classify biopsies obtained during olfactory neuroblastoma (ONB) surgery; 2) define the relationship between posttest probabilities and pretest probabilities from frozen section analysis; and 3) review incorrectly classified specimens.Study Design: Study of diagnostic accuracy.Methods: We searched our institution's pathology database for patients who had ONB surgery between January 1, 2000 and November 16, 2012. We only included patients who had a definitive diagnosis of ONB prior to surgery and frozen sections obtained during surgery. All frozen sections in this study had corresponding permanent sections available to serve as a gold standard. This database was analyzed to obtain classification statistics. The confidence intervals for classification performance were obtained using the bootstrap sampling method. Confidence intervals for posttest probability curves were derived using the Taylor series expansion. Finally, we obtained and reviewed the slides from ambiguous or incorrect reads.Results: A total of 459 specimens from 33 patients were analyzed. We found the following performance characteristics: sensitivity: 0.89 (0.81, 0.94); specificity: 0.96 (0.94, 0.98); accuracy: 0.95 (0.92, 0.96); likelihood ratio positive: 24.4 (14.5, 44.1); prevalence: 0.20 (0.17, 0.25); positive predictive value: 0.86 (0.78, 0.92); and negative predictive value: 0.97 (0.95, 0.99). Histopathologic review revealed that crush artifacts and inadequate specimen size were major sources of incorrect reads.Conclusion: We found frozen section assessment of ONB specimens to be an excellent tool for the assessment of intraoperative margins.Level of Evidence: NA. Laryngoscope, 127:1735–1741, 2017