Allon Goldberg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Allon Goldberg has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Stacey Schepens
Wayne State University
3 shared publicationsMelissa Wallace
2 shared publicationsAllison Casby
1 shared publicationCarly E. Siskind
Department of Neurology and Center for Molecular Medicine and Genetics, School of Medicine, Wayne State University, 421 E. Canfield Rd, Detroit, MI 48201, USA
1 shared publicationGerry E. Conti
Department of Health Care Sciences, Program in Occupational Therapy, Human Movement Laboratory, Wayne State University, 259 Mack Ave., Detroit, MI 48201, USA
1 shared publicationJames William Russell
Department of Neurology, University of Maryland, Baltimore, MD
1 shared publication
Latest Publications
- 1 August 2012
- Published by Springer Nature in Aging Clinical and Experimental Research
- Vol. 24 (4) , 339-344
The five-times-sit-to-stand test: validity, reliability and detectable change in older females
Background and aims: The five-timessit- to-stand test (FTSST) is a physical performance test commonly-used in clinical geriatric studies. The relationship between FTSST times and dynamic balance has not been widely investigated in older adults. The main objective of this study was to evaluate the validity of the FTSST as a measure of dynamic balance in older adults. A second objective was to quantify relative and absolute reliability, as well as minimum detectable change (MDC) of the FTSST in older adults. Methods: Twenty-nine females (mean age, 73.6 years) performed two trials of the FTSST, timed up and go (TUG), and functional reach (FR) tests. Validity of the FTSST as a measure of dynamic balance was evaluated by quantifying strength of relationships between the FTSST and two measures of dynamic balance, TUG and FR, using Pearson’s correlation coefficient. Measures of relative [intraclass correlation coefficient (ICC)] and absolute [standard error of measurement (SEM)] reliability, as well as the MDC at the 95% confidence level (MDC95) were computed for the FTSST. Results: The Pearson’s correlation coefficient between FTSST and TUG (r=0.64, pConclusions: The FTSST is a valid measure of dynamic balance and functional mobility in older adults. The high ICC and low SEM and SEM% suggest excellent relative and absolute reliability and reproducibility of the FTSST in older adults. Change in FTSST performance should exceed 2.5 seconds to be considered real change beyond measurement error.
- 1 August 2012
- Published by Springer Nature in Aging Clinical and Experimental Research
- Vol. 24 (4) , 339-344
The five-times-sit-to-stand test: validity, reliability and detectable change in older females
Background and aims: The five-timessit- to-stand test (FTSST) is a physical performance test commonly-used in clinical geriatric studies. The relationship between FTSST times and dynamic balance has not been widely investigated in older adults. The main objective of this study was to evaluate the validity of the FTSST as a measure of dynamic balance in older adults. A second objective was to quantify relative and absolute reliability, as well as minimum detectable change (MDC) of the FTSST in older adults. Methods: Twenty-nine females (mean age, 73.6 years) performed two trials of the FTSST, timed up and go (TUG), and functional reach (FR) tests. Validity of the FTSST as a measure of dynamic balance was evaluated by quantifying strength of relationships between the FTSST and two measures of dynamic balance, TUG and FR, using Pearson’s correlation coefficient. Measures of relative [intraclass correlation coefficient (ICC)] and absolute [standard error of measurement (SEM)] reliability, as well as the MDC at the 95% confidence level (MDC95) were computed for the FTSST. Results: The Pearson’s correlation coefficient between FTSST and TUG (r=0.64, pConclusions: The FTSST is a valid measure of dynamic balance and functional mobility in older adults. The high ICC and low SEM and SEM% suggest excellent relative and absolute reliability and reproducibility of the FTSST in older adults. Change in FTSST performance should exceed 2.5 seconds to be considered real change beyond measurement error.
- 1 October 2011
- Published by Springer Nature in Aging Clinical and Experimental Research
- Vol. 23 (5-6) , 406-412
Measurement error and minimum detectable change in 4-meter gait speed in older adults
Background and aims: Gait speed is a commonly-used assessment and outcomes measure in geriatric clinical and research settings. Although relative reliability of usual gait speed has been well studied in community-dwelling older adults, less emphasis has been placed on a measure of absolute reliability (the standard error of measurement [SEM]), and on an associated clinically relevant index of real change in gait speed, minimum detectable change (MDC). The purpose of this study was to quantify measurement error and MDC for usual gait speed over 4 meters in community-dwelling older adults ambulating at intermediate and fast speeds. Methods: Community-dwelling older adults ambulating at intermediate gait speed (IGS), (n=15, mean age 74.2 yrs) and fast gait speed (FGS), (n=15, mean age 72.1) were included in this study. Participants performed two trials of gait speed over a distance of 4 meters. SEM and MDC at the 95% confidence level (MDC95) were computed for the IGS and FGS groups. Results: Mean gait speed was 85.4 cm/s (IGS) and 129.9 cm/s (FGS). Measurement error (95 was computed as 10.8 cm/s and 14.4 cm/s for the IGS and FGS groups, respectively. Conclusions: To be considered real change beyond the bounds of measurement error, change in 4-meter gait speed should exceed 10.8 cm/s (for intermediate speed ambulators) or 14.4 cm/s (for fast speed ambulators). Low measurement error in assessing 4-meter gait speed in community-dwelling older adults suggests that gait speed assessed over short distances has excellent reproducibility across trials. Low minimum change values suggest that 4-meter gait speed may be responsive and sensitive to change.
- 1 October 2011
- Published by Springer Nature in Aging Clinical and Experimental Research
- Vol. 23 (5-6) , 406-412
Measurement error and minimum detectable change in 4-meter gait speed in older adults
Background and aims: Gait speed is a commonly-used assessment and outcomes measure in geriatric clinical and research settings. Although relative reliability of usual gait speed has been well studied in community-dwelling older adults, less emphasis has been placed on a measure of absolute reliability (the standard error of measurement [SEM]), and on an associated clinically relevant index of real change in gait speed, minimum detectable change (MDC). The purpose of this study was to quantify measurement error and MDC for usual gait speed over 4 meters in community-dwelling older adults ambulating at intermediate and fast speeds. Methods: Community-dwelling older adults ambulating at intermediate gait speed (IGS), (n=15, mean age 74.2 yrs) and fast gait speed (FGS), (n=15, mean age 72.1) were included in this study. Participants performed two trials of gait speed over a distance of 4 meters. SEM and MDC at the 95% confidence level (MDC95) were computed for the IGS and FGS groups. Results: Mean gait speed was 85.4 cm/s (IGS) and 129.9 cm/s (FGS). Measurement error (95 was computed as 10.8 cm/s and 14.4 cm/s for the IGS and FGS groups, respectively. Conclusions: To be considered real change beyond the bounds of measurement error, change in 4-meter gait speed should exceed 10.8 cm/s (for intermediate speed ambulators) or 14.4 cm/s (for fast speed ambulators). Low measurement error in assessing 4-meter gait speed in community-dwelling older adults suggests that gait speed assessed over short distances has excellent reproducibility across trials. Low minimum change values suggest that 4-meter gait speed may be responsive and sensitive to change.
- 1 April 2011
- Published by Elsevier in Gait & Posture
- Vol. 33 (4) , 737-739
Minimum detectable change for single-leg-stance-time in older adults
- 1 April 2011
- Published by Elsevier in Gait & Posture
- Vol. 33 (4) , 737-739
Minimum detectable change for single-leg-stance-time in older adults
- 16 December 2010
- Vol. 33 (3) , 122-7
Concurrent validity and reliability of the maximum step length test in older adults.
This study assessed concurrent validity of the Maximum Step Length (MSL) test as a measure of falls risk and balance-impairment for community-dwelling older adults. A secondary purpose was to determine intra- and interrater reliability and standard error of measurement of the MSL test. Thirty-five community-dwelling adults aged 60 or older provided a 12-month falls history. Functional measures included the MSL test, Single Limb Stance Time, Functional Reach test, Timed Up and Go test, and a test of trunk position sense. Pearson correlation coefficient, intraclass correlation coefficient (a coefficient of relative reliability), and standard error of measurement (a measure of absolute reliability) were calculated as indices of concurrent validity and reliability of the MSL test. Minimal detectable change was also calculated; this represents actual change beyond that of measurement error or random variation in stepping performance. Correlations between MSL score and clinical balance measures and self-reported number of falls in the past 12 months ranged from fair to good. Same-day and 1-month intrarater test-retest reliability of the MSL test was excellent. Same-day interrater reliability between 2 raters was also excellent. Measurement error of the MSL test was low. Minimal detectable change for the MSL test at the 95% confidence level was 7.32 inches. The MSL test appears to be a valid and reliable measure of balance-impairment and falls risk in older adults. Clinicians should consider incorporating the MSL test into their battery of falls risk assessment tools. Use of this test as a screening measure may reduce the incidence of falls in community-dwelling older adults. Real change in performance requires a difference of more than 7.32 inches between trials; differences less than this should be interpreted as being due to measurement error or random variation in stepping performance.
- 16 December 2010
- Vol. 33 (3) , 122-7
Concurrent validity and reliability of the maximum step length test in older adults.
This study assessed concurrent validity of the Maximum Step Length (MSL) test as a measure of falls risk and balance-impairment for community-dwelling older adults. A secondary purpose was to determine intra- and interrater reliability and standard error of measurement of the MSL test. Thirty-five community-dwelling adults aged 60 or older provided a 12-month falls history. Functional measures included the MSL test, Single Limb Stance Time, Functional Reach test, Timed Up and Go test, and a test of trunk position sense. Pearson correlation coefficient, intraclass correlation coefficient (a coefficient of relative reliability), and standard error of measurement (a measure of absolute reliability) were calculated as indices of concurrent validity and reliability of the MSL test. Minimal detectable change was also calculated; this represents actual change beyond that of measurement error or random variation in stepping performance. Correlations between MSL score and clinical balance measures and self-reported number of falls in the past 12 months ranged from fair to good. Same-day and 1-month intrarater test-retest reliability of the MSL test was excellent. Same-day interrater reliability between 2 raters was also excellent. Measurement error of the MSL test was low. Minimal detectable change for the MSL test at the 95% confidence level was 7.32 inches. The MSL test appears to be a valid and reliable measure of balance-impairment and falls risk in older adults. Clinicians should consider incorporating the MSL test into their battery of falls risk assessment tools. Use of this test as a screening measure may reduce the incidence of falls in community-dwelling older adults. Real change in performance requires a difference of more than 7.32 inches between trials; differences less than this should be interpreted as being due to measurement error or random variation in stepping performance.
- 15 November 2010
- Published by Elsevier in Journal of the Neurological Sciences
- Vol. 298 (1-2) , 91-95
Deficits in stepping response time are associated with impairments in balance and mobility in people with Huntington disease
- 15 November 2010
- Published by Elsevier in Journal of the Neurological Sciences
- Vol. 298 (1-2) , 91-95
Deficits in stepping response time are associated with impairments in balance and mobility in people with Huntington disease
- 1 July 2008
- Published by Elsevier in Journal of the Neurological Sciences
- Vol. 270 (1-2) , 165-171
Standing balance and trunk position sense in impaired glucose tolerance (IGT)-related peripheral neuropathy
- 1 July 2008
- Published by Elsevier in Journal of the Neurological Sciences
- Vol. 270 (1-2) , 165-171
Standing balance and trunk position sense in impaired glucose tolerance (IGT)-related peripheral neuropathy
- Open Access
- 1 October 2005
- Published by Oxford University Press (OUP) in The Journals of Gerontology, Series A: Biological Sciences and Medical Sciences
- Vol. 60 (10) , 1310-1314
Trunk Repositioning Errors Are Increased in Balance-Impaired Older Adults
Background. Controlling the flexing trunk is critical in recovering from a loss of balance and avoiding a fall. To investigate the relationship between trunk control and balance in older adults, we measured trunk repositioning accuracy in young and balance-impaired and unimpaired older adults. Methods. Young adults (N = 8, mean age 24.3 years) and two groups of community-dwelling older adults defined by unipedal stance time (UST)—a balance-unimpaired group (UST > 30 seconds, N = 7, mean age 73.9 years) and a balance-impaired group (UST < 5 seconds, N = 8, mean age 79.6 years)—were tested in standing trunk control ability by reproducing a ∼30° trunk flexion angle under three visual-surface conditions: eyes opened and closed on the floor, and eyes opened on foam. Errors in reproducing the angle were defined as trunk repositioning errors (TREs). Clinical measures related to balance, trunk extensor strength, and self-reported disability were obtained. Results. TREs were significantly greater in the balance-impaired group than in the other groups, even when controlling for trunk extensor strength and body mass. In older adults, there were significant correlations between TREs and three clinical measures of balance and fall risk, UST and maximum step length (−0.65 to −0.75), and Timed Up & Go score (0.55), and between TREs and age (0.63–0.76). In each group TREs were similar under the three visual-surface conditions. Test–retest reliability for TREs was good to excellent (intraclass correlation coefficients ≥0.74). Conclusions. Older balance-impaired adults have larger TREs, and thus poorer trunk control, than do balance-unimpaired older individuals. TREs are reliable and valid measures of underlying balance impairment in older adults, and may eventually prove to be useful in predicting the ability to recover from losses of balance and to avoid falls.
- 1 October 2005
- Published by Oxford University Press (OUP) in The Journals of Gerontology, Series A: Biological Sciences and Medical Sciences
- Vol. 60 (10) , 1310-1314
Open AccessTrunk Repositioning Errors Are Increased in Balance-Impaired Older Adults
Background. Controlling the flexing trunk is critical in recovering from a loss of balance and avoiding a fall. To investigate the relationship between trunk control and balance in older adults, we measured trunk repositioning accuracy in young and balance-impaired and unimpaired older adults. Methods. Young adults (N = 8, mean age 24.3 years) and two groups of community-dwelling older adults defined by unipedal stance time (UST)—a balance-unimpaired group (UST > 30 seconds, N = 7, mean age 73.9 years) and a balance-impaired group (UST < 5 seconds, N = 8, mean age 79.6 years)—were tested in standing trunk control ability by reproducing a ∼30° trunk flexion angle under three visual-surface conditions: eyes opened and closed on the floor, and eyes opened on foam. Errors in reproducing the angle were defined as trunk repositioning errors (TREs). Clinical measures related to balance, trunk extensor strength, and self-reported disability were obtained. Results. TREs were significantly greater in the balance-impaired group than in the other groups, even when controlling for trunk extensor strength and body mass. In older adults, there were significant correlations between TREs and three clinical measures of balance and fall risk, UST and maximum step length (−0.65 to −0.75), and Timed Up & Go score (0.55), and between TREs and age (0.63–0.76). In each group TREs were similar under the three visual-surface conditions. Test–retest reliability for TREs was good to excellent (intraclass correlation coefficients ≥0.74). Conclusions. Older balance-impaired adults have larger TREs, and thus poorer trunk control, than do balance-unimpaired older individuals. TREs are reliable and valid measures of underlying balance impairment in older adults, and may eventually prove to be useful in predicting the ability to recover from losses of balance and to avoid falls.