Frederic Leblond
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Frederic Leblond has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Brian W. Pogue
Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
8 shared publications - Brian Campbell Wilson
Department of Medical Biophysics, University Health Network, University of Toronto, Toronto, ON M5G 1L7, Canada
3 shared publications - Kenneth M. Tichauer
Lawson Research Institute, St. Joseph’s Health Care London, London, ON, Canada
3 shared publications - David W. Roberts
Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
2 shared publications - Hamid Dehghani
University of Birmingham
2 shared publications - Keith D. Paulsen
Thayer School of Engineering, Dartmouth College
2 shared publications
Latest Publications
- 21 June 2012
- Published by Optica Publishing Group in Optics Letters
- Vol. 37 (13) , 2559-2561
Multiple-gate time domain diffuse fluorescence tomography allows more sparse tissue sampling without compromising image quality
Diffuse fluorescence tomography systems that employ highly sensitive photo-multiplier tubes for single-photon detection are pushing the sensitivity limits of the field. However, each of these detectors only offers a single data projection to be collected, implying these imaging systems either require many detectors or long scan times to collect full data sets for image reconstruction. This study presents a method of utilizing the time-resolved collection capabilities of time-correlated single-photon counting techniques to increase spatial resolution and to reduce the number of data projections to produce reliable fluorescence reconstructions. Experimental tissue phantom results demonstrate that using data at 10 time gates in the fluorescence reconstructions for only 40 data projections provided superior image accuracy when compared to reconstructions on 320 continuous-wave data projections.
- 21 June 2012
- Published by Optica Publishing Group in Optics Letters
- Vol. 37 (13) , 2559-2561
Multiple-gate time domain diffuse fluorescence tomography allows more sparse tissue sampling without compromising image quality
Diffuse fluorescence tomography systems that employ highly sensitive photo-multiplier tubes for single-photon detection are pushing the sensitivity limits of the field. However, each of these detectors only offers a single data projection to be collected, implying these imaging systems either require many detectors or long scan times to collect full data sets for image reconstruction. This study presents a method of utilizing the time-resolved collection capabilities of time-correlated single-photon counting techniques to increase spatial resolution and to reduce the number of data projections to produce reliable fluorescence reconstructions. Experimental tissue phantom results demonstrate that using data at 10 time gates in the fluorescence reconstructions for only 40 data projections provided superior image accuracy when compared to reconstructions on 320 continuous-wave data projections.
- 17 May 2012
- Published by Optica Publishing Group in Optics Letters
- Vol. 37 (11) , 1817-1819
A spectrally constrained dual-band normalization technique for protoporphyrin IX quantification in fluorescence-guided surgery
We report a dual-band normalization technique for in vivo quantification of the metabolic biomarker, protoporphyrin IX (PpIX), during brain tumor resection procedures. The accuracy of the approach was optimized in tissue simulating phantoms with varying absorption and scattering properties, validated with fluorimetric assessments on ex vivo brain tissue, and tested on human data acquired in vivo during fluorescence-guided surgery of brain tumors. The results demonstrate that the dual-band normalization technique allows PpIX concentrations to be accurately quantified by correction with reflectance data recorded and integrated within only two narrow wavelength intervals. The simplicity of the method lends itself to the enticing prospect that the method could be applicable to wide-field applications in quantitative fluorescence imaging and dosimetry in photodynamic therapy.
- 17 May 2012
- Published by Optica Publishing Group in Optics Letters
- Vol. 37 (11) , 1817-1819
A spectrally constrained dual-band normalization technique for protoporphyrin IX quantification in fluorescence-guided surgery
We report a dual-band normalization technique for in vivo quantification of the metabolic biomarker, protoporphyrin IX (PpIX), during brain tumor resection procedures. The accuracy of the approach was optimized in tissue simulating phantoms with varying absorption and scattering properties, validated with fluorimetric assessments on ex vivo brain tissue, and tested on human data acquired in vivo during fluorescence-guided surgery of brain tumors. The results demonstrate that the dual-band normalization technique allows PpIX concentrations to be accurately quantified by correction with reflectance data recorded and integrated within only two narrow wavelength intervals. The simplicity of the method lends itself to the enticing prospect that the method could be applicable to wide-field applications in quantitative fluorescence imaging and dosimetry in photodynamic therapy.
- 5 October 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (21) , 6823-6837
Analytic expression of fluorescence ratio detection correlates with depth in multi-spectral sub-surface imaging
Here we derived analytical solutions to diffuse light transport in biological tissue based on spectral deformation of diffused near-infrared measurements. These solutions provide a closed-form mathematical expression which predicts that the depth of a fluorescent molecule distribution is linearly related to the logarithm of the ratio of fluorescence at two different wavelengths. The slope and intercept values of the equation depend on the intrinsic values of absorption and reduced scattering of tissue. This linear behavior occurs if the following two conditions are satisfied: the depth is beyond a few millimeters and the tissue is relatively homogeneous. We present experimental measurements acquired with a broad-beam non-contact multi-spectral fluorescence imaging system using a hemoglobin-containing diffusive phantom. Preliminary results confirm that a significant correlation exists between the predicted depth of a distribution of protoporphyrin IX molecules and the measured ratio of fluorescence at two different wavelengths. These results suggest that depth assessment of fluorescence contrast can be achieved in fluorescence-guided surgery to allow improved intra-operative delineation of tumor margins.
- 5 October 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (21) , 6823-6837
Analytic expression of fluorescence ratio detection correlates with depth in multi-spectral sub-surface imaging
Here we derived analytical solutions to diffuse light transport in biological tissue based on spectral deformation of diffused near-infrared measurements. These solutions provide a closed-form mathematical expression which predicts that the depth of a fluorescent molecule distribution is linearly related to the logarithm of the ratio of fluorescence at two different wavelengths. The slope and intercept values of the equation depend on the intrinsic values of absorption and reduced scattering of tissue. This linear behavior occurs if the following two conditions are satisfied: the depth is beyond a few millimeters and the tissue is relatively homogeneous. We present experimental measurements acquired with a broad-beam non-contact multi-spectral fluorescence imaging system using a hemoglobin-containing diffusive phantom. Preliminary results confirm that a significant correlation exists between the predicted depth of a distribution of protoporphyrin IX molecules and the measured ratio of fluorescence at two different wavelengths. These results suggest that depth assessment of fluorescence contrast can be achieved in fluorescence-guided surgery to allow improved intra-operative delineation of tumor margins.
- Open Access
- 19 September 2011
- Published by Optica Publishing Group in Optics Letters
- Vol. 36 (19) , 3723-3725
Toward whole-body optical imaging of rats using single-photon counting fluorescence tomography
We used single-photon counting (SPC) detection for diffuse fluorescence tomography to image nanomolar (nM) concentrations of reporter dyes through a rat. Detailed phantom data are presented to show that every centimeter increase in tissue thickness leads to 1 order of magnitude decrease in the minimum fluorophore concentration detectable for a given detector sensitivity. Specifically, here, detection of Alexa Fluor 647 dyes is shown to be achievable for concentrations as low as () through more than in tissue phantoms, which indicates that this is feasible in larger rodent models. Because it is possible to detect sub-nM fluorescent inclusions with SPC technology in rats, it follows that it is possible to localize subpicomolar fluorophore concentrations in mice, putting the concentration sensitivity limits on the same order as nuclear medicine methods.- 19 September 2011
- Published by Optica Publishing Group in Optics Letters
- Vol. 36 (19) , 3723-3725
Open AccessToward whole-body optical imaging of rats using single-photon counting fluorescence tomography
We used single-photon counting (SPC) detection for diffuse fluorescence tomography to image nanomolar (nM) concentrations of reporter dyes through a rat. Detailed phantom data are presented to show that every centimeter increase in tissue thickness leads to 1 order of magnitude decrease in the minimum fluorophore concentration detectable for a given detector sensitivity. Specifically, here, detection of Alexa Fluor 647 dyes is shown to be achievable for concentrations as low as () through more than in tissue phantoms, which indicates that this is feasible in larger rodent models. Because it is possible to detect sub-nM fluorescent inclusions with SPC technology in rats, it follows that it is possible to localize subpicomolar fluorophore concentrations in mice, putting the concentration sensitivity limits on the same order as nuclear medicine methods. - 10 February 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7883, 78833P-78833
ALA-induced PpIX spectroscopy for brain tumor image-guided surgery
Maximizing the extent of brain tumor resection correlates with improved survival and quality of life outcomes in patients. Optimal surgical resection requires accurate discrimination between normal and abnormal, cancerous tissue. We present our recent experience using quantitative optical spectroscopy in 5-aminolevulinic acid (ALA)-induced protoporphyrin IX (PpIX) fluorescence-guided resection. Exogenous administration of ALA leads to preferential accumulation in tumor tissue of the fluorescent compound, PpIX, which can be used for in vivo surgical guidance. Using the state of the art approach with a fluorescence surgical microscope, we have been able to visualize a subset of brain tumors, but the sensitivity and accuracy of fluorescence detection for tumor tissue with this system are low. To take full advantage of the biological selectivity of PpIX accumulation in brain tumors, we used a quantitative optical spectroscopy system for in vivo measurements of PpIX tissue concentrations. We have shown that, using our quantitative approach for determination of biomarker concentrations, ALA-induced PpIX fluorescence-guidance can achieve accuracies of greater than 90% for most tumor histologies. Here we show multivariate analysis of fluorescence and diffuse reflectance signals in brain tumors with comparable diagnostic performance to our previously reported quantitative approach. These results are promising, since they show that technological improvements in current fluorescence-guided surgical technologies and more biologically relevant approaches are required to take full advantage of fluorescent biomarkers, achieve better tumor identification, increase extent of resection, and subsequently, lead to improve survival and quality of life in patients.
- 10 February 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7883, 78833P-78833
ALA-induced PpIX spectroscopy for brain tumor image-guided surgery
Maximizing the extent of brain tumor resection correlates with improved survival and quality of life outcomes in patients. Optimal surgical resection requires accurate discrimination between normal and abnormal, cancerous tissue. We present our recent experience using quantitative optical spectroscopy in 5-aminolevulinic acid (ALA)-induced protoporphyrin IX (PpIX) fluorescence-guided resection. Exogenous administration of ALA leads to preferential accumulation in tumor tissue of the fluorescent compound, PpIX, which can be used for in vivo surgical guidance. Using the state of the art approach with a fluorescence surgical microscope, we have been able to visualize a subset of brain tumors, but the sensitivity and accuracy of fluorescence detection for tumor tissue with this system are low. To take full advantage of the biological selectivity of PpIX accumulation in brain tumors, we used a quantitative optical spectroscopy system for in vivo measurements of PpIX tissue concentrations. We have shown that, using our quantitative approach for determination of biomarker concentrations, ALA-induced PpIX fluorescence-guidance can achieve accuracies of greater than 90% for most tumor histologies. Here we show multivariate analysis of fluorescence and diffuse reflectance signals in brain tumors with comparable diagnostic performance to our previously reported quantitative approach. These results are promising, since they show that technological improvements in current fluorescence-guided surgical technologies and more biologically relevant approaches are required to take full advantage of fluorescent biomarkers, achieve better tumor identification, increase extent of resection, and subsequently, lead to improve survival and quality of life in patients.
- Open Access
- 29 November 2010
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 1 (5) , 1514-1531
Singular value decomposition metrics show limitations of detector design in diffuse fluorescence tomography
The spatial resolution and recovered contrast of images reconstructed from diffuse fluorescence tomography data are limited by the high scattering properties of light propagation in biological tissue. As a result, the image reconstruction process can be exceedingly vulnerable to inaccurate prior knowledge of tissue optical properties and stochastic noise. In light of these limitations, the optimal source-detector geometry for a fluorescence tomography system is non-trivial, requiring analytical methods to guide design. Analysis of the singular value decomposition of the matrix to be inverted for image reconstruction is one potential approach, providing key quantitative metrics, such as singular image mode spatial resolution and singular data mode frequency as a function of singular mode. In the present study, these metrics are used to analyze the effects of different sources of noise and model errors as related to image quality in the form of spatial resolution and contrast recovery. The image quality is demonstrated to be inherently noise-limited even when detection geometries were increased in complexity to allow maximal tissue sampling, suggesting that detection noise characteristics outweigh detection geometry for achieving optimal reconstructions.
- 29 November 2010
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 1 (5) , 1514-1531
Open AccessSingular value decomposition metrics show limitations of detector design in diffuse fluorescence tomography
The spatial resolution and recovered contrast of images reconstructed from diffuse fluorescence tomography data are limited by the high scattering properties of light propagation in biological tissue. As a result, the image reconstruction process can be exceedingly vulnerable to inaccurate prior knowledge of tissue optical properties and stochastic noise. In light of these limitations, the optimal source-detector geometry for a fluorescence tomography system is non-trivial, requiring analytical methods to guide design. Analysis of the singular value decomposition of the matrix to be inverted for image reconstruction is one potential approach, providing key quantitative metrics, such as singular image mode spatial resolution and singular data mode frequency as a function of singular mode. In the present study, these metrics are used to analyze the effects of different sources of noise and model errors as related to image quality in the form of spatial resolution and contrast recovery. The image quality is demonstrated to be inherently noise-limited even when detection geometries were increased in complexity to allow maximal tissue sampling, suggesting that detection noise characteristics outweigh detection geometry for achieving optimal reconstructions.
- Top Cited Papers
- 1 January 2010
- Published by Elsevier in Journal of Photochemistry and Photobiology B: Biology
- Vol. 98 (1) , 77-94
Pre-clinical whole-body fluorescence imaging: Review of instruments, methods and applications
- 1 January 2010
- Published by Elsevier in Journal of Photochemistry and Photobiology B: Biology
- Vol. 98 (1) , 77-94
Top Cited PapersPre-clinical whole-body fluorescence imaging: Review of instruments, methods and applications
- 27 May 2009
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 26 (6) , 1444-1457
Early-photon fluorescence tomography: spatial resolution improvements and noise stability considerations
In vivo tissue imaging using near-infrared light suffers from low spatial resolution and poor contrast recovery because of highly scattered photon transport. For diffuse optical tomography (DOT) and fluorescence molecular tomography (FMT), the resolution is limited to about 5–10% of the diameter of the tissue being imaged, which puts it in the range of performance seen in nuclear medicine. This paper introduces the mathematical formalism explaining why the resolution of FMT can be significantly improved when using instruments acquiring fast time-domain optical signals. This is achieved through singular-value analysis of the time-gated inverse problem based on weakly diffused photons. Simulations relevant to mouse imaging are presented showing that, in stark contrast to steady-state imaging, early time-gated intensities (within or ) can in principle be used to resolve small fluorescent targets (radii from ) separated by less than .- 27 May 2009
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 26 (6) , 1444-1457
Early-photon fluorescence tomography: spatial resolution improvements and noise stability considerations
In vivo tissue imaging using near-infrared light suffers from low spatial resolution and poor contrast recovery because of highly scattered photon transport. For diffuse optical tomography (DOT) and fluorescence molecular tomography (FMT), the resolution is limited to about 5–10% of the diameter of the tissue being imaged, which puts it in the range of performance seen in nuclear medicine. This paper introduces the mathematical formalism explaining why the resolution of FMT can be significantly improved when using instruments acquiring fast time-domain optical signals. This is achieved through singular-value analysis of the time-gated inverse problem based on weakly diffused photons. Simulations relevant to mouse imaging are presented showing that, in stark contrast to steady-state imaging, early time-gated intensities (within or ) can in principle be used to resolve small fluorescent targets (radii from ) separated by less than .- 12 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7164
Brain tumor resection guided by fluorescence imaging
We present the methods that are being used in the scope of an on-going clinical trial designed to assess the usefulness of ALA-PpIX fluorescence imaging when used in conjunction with pre-operative MRI. The overall objective is to develop imaging-based neuronavigation approaches to aid in maximizing the completeness of brain tumor resection, thereby improving patient survival rate. In this paper we present the imaging methods that are used, emphasizing technical aspects relating to the fluorescence optical microscope, including initial validation approaches based on phantom and small-animal experiments. The surgical workflow is then described in detail based on a high-grade glioma resection we performed.
- 12 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7164
Brain tumor resection guided by fluorescence imaging
We present the methods that are being used in the scope of an on-going clinical trial designed to assess the usefulness of ALA-PpIX fluorescence imaging when used in conjunction with pre-operative MRI. The overall objective is to develop imaging-based neuronavigation approaches to aid in maximizing the completeness of brain tumor resection, thereby improving patient survival rate. In this paper we present the imaging methods that are used, emphasizing technical aspects relating to the fluorescence optical microscope, including initial validation approaches based on phantom and small-animal experiments. The surgical workflow is then described in detail based on a high-grade glioma resection we performed.
- 8 February 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6434, 64340S
Improved quantification of fluorescence in 3-D in a realistic mouse phantom
Advanced imaging systems and theoretical models have been developed to quantify fluorescence, and this theoretical framework involves numerical-based solutions of a set of coupled diffusion equations. One key to advancing this modality is the extension of the imaging into realistic tissue geometries, which can be dynamically updated from data from other high resolution modalities. Here we explore the quantification of fluorescence in a three-dimensional (3-D) mouse phantom tagged with heterogeneous optical properties. A finite element model for the diffusion equation was used to approximate light propagation along with Newton's method for image reconstruction, to recover 3-D images of fluorescent yield. Using measurements generated on a brain tumor in a mouse with 2% noise, our results show that only 11.4% of the expected fluorescent yield could be recovered without any prior knowledge about the spatial structure of the domain. Using a parameter reduction scheme based upon prior spatial information of the location and size of the tumor, 100% of the expected value could be estimated. These preliminary results indicate that image guided fluorescence spectroscopy has the ability to provide accurate fluorescence recovery, whereas diffuse imaging based recovery is limited in the ability to quantify.
- 8 February 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6434, 64340S
Improved quantification of fluorescence in 3-D in a realistic mouse phantom
Advanced imaging systems and theoretical models have been developed to quantify fluorescence, and this theoretical framework involves numerical-based solutions of a set of coupled diffusion equations. One key to advancing this modality is the extension of the imaging into realistic tissue geometries, which can be dynamically updated from data from other high resolution modalities. Here we explore the quantification of fluorescence in a three-dimensional (3-D) mouse phantom tagged with heterogeneous optical properties. A finite element model for the diffusion equation was used to approximate light propagation along with Newton's method for image reconstruction, to recover 3-D images of fluorescent yield. Using measurements generated on a brain tumor in a mouse with 2% noise, our results show that only 11.4% of the expected fluorescent yield could be recovered without any prior knowledge about the spatial structure of the domain. Using a parameter reduction scheme based upon prior spatial information of the location and size of the tumor, 100% of the expected value could be estimated. These preliminary results indicate that image guided fluorescence spectroscopy has the ability to provide accurate fluorescence recovery, whereas diffuse imaging based recovery is limited in the ability to quantify.