Stefano Di Domenico
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stefano Di Domenico has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Gregorio Santori
Department of Surgical Sciences and Integrated Diagnostics (DISC), University of Genoa, 16132 Genoa, Italy
4 shared publications - Maximiliano Gelli
Department of Anaesthesia, Surgery and Interventional Radiology, Gustave Roussy Hospital, University of Paris-Saclay, Villejuif, France
4 shared publications U. Valente
Department of Transplantation, San Martino University Hospital, Genoa, Italy
4 shared publicationsUmberto Valente
Department of General Surgery and Organ Transplantation, San Martino University Hospital, Largo Rosanna Benzi 10, 16132 Genoa, Italy
4 shared publicationsE. Andorno
Department of Transplantation, San Martino University Hospital, Genoa, Italy
3 shared publicationsG. Bottino
2 shared publications
Latest Publications
- Open Access
ARDUINO-BASED ORGAN PERFUSION SYSTEM
Laboratory equipment could be expensive and their cost can be unsustainable for scientists with limited financial resources. In order to overcome these impediments and to improve our experimental studies on liver resection in rats, a multipurpose organ perfusion system was projected and realized using low-cost components. The device is based on Arduino boards, an easy-to-use and open-source microcontroller, that receives digital and analog inputs, can produce digital outputs and it is programmable in C++. Our perfusion system is composed of: 1) the main control unit that receives pressure data from two independent pressure transducers commonly used in the OR, it receives input from two potentiometers, seven switches, and a push-button; it can display data with an LCD and it can control the speed and the direction of two independent peristaltic-pump, 2) a motor unit composed by peristaltic pumps controlled by two stepper motors, 3) a thermostatic unit that received data from temperature probe and can control up to three heating units. The pulsating flow generated by the peristaltic pump can be flattened by a dampener unit to simulate the portal flow, and the interposition of a hollow-fiber micro-oxygenator can increase the pO2 of the perfusion fluid in the arterial line. This cheap system is designed to measure the compliance of regenerating rat liver at increasing and decreasing portal and arterial flow during normothermic ex-vivo perfusion. However the system can be easily rearranged to perform different kinds of organ perfusion: subnormothermic o hypothermic ex-vivo preservation tests can be done by adding a Peltier-based cooling module. Indeed the main control unit can be programmed to control the flow rate based on pressure data to realize peritoneal perfusion or isolated limb perfusion.
Open AccessARDUINO-BASED ORGAN PERFUSION SYSTEM
Laboratory equipment could be expensive and their cost can be unsustainable for scientists with limited financial resources. In order to overcome these impediments and to improve our experimental studies on liver resection in rats, a multipurpose organ perfusion system was projected and realized using low-cost components. The device is based on Arduino boards, an easy-to-use and open-source microcontroller, that receives digital and analog inputs, can produce digital outputs and it is programmable in C++. Our perfusion system is composed of: 1) the main control unit that receives pressure data from two independent pressure transducers commonly used in the OR, it receives input from two potentiometers, seven switches, and a push-button; it can display data with an LCD and it can control the speed and the direction of two independent peristaltic-pump, 2) a motor unit composed by peristaltic pumps controlled by two stepper motors, 3) a thermostatic unit that received data from temperature probe and can control up to three heating units. The pulsating flow generated by the peristaltic pump can be flattened by a dampener unit to simulate the portal flow, and the interposition of a hollow-fiber micro-oxygenator can increase the pO2 of the perfusion fluid in the arterial line. This cheap system is designed to measure the compliance of regenerating rat liver at increasing and decreasing portal and arterial flow during normothermic ex-vivo perfusion. However the system can be easily rearranged to perform different kinds of organ perfusion: subnormothermic o hypothermic ex-vivo preservation tests can be done by adding a Peltier-based cooling module. Indeed the main control unit can be programmed to control the flow rate based on pressure data to realize peritoneal perfusion or isolated limb perfusion.
- Open Access
Arduino-based lab equipment: building a multipurpose pressure transducer device
Background Lab equipments could be expensive and their cost can be unsustainable for scientist with limited financial resources. In order to overcome these impediments and to improve our experimental studies on liver resection in rat, a multipurpose pressure measurement device was project and realized using low cost components. Materials and Methods The device is based on an Arduino board, an easy-to-use and open-source microcontroller, that receives analog inputs from an instrumental amplifier connected to a disposable pressure traducer. The analogic inputs are converted to digital values and an LCD can visualize the pressure values calculated from the digital inputs. Programs has been written using C++ within the Arduino IDE, while the pressure data has been recorded on PC using data-logging freeware. Calibration has been performed using a water column as standard. Measure agreement was studied by comparing this device with a water column and with a standard clinical monitoring system. Results The final device it is handy and portable, it costs less the 20 euros and both the hardware and the software are easy modifiable. Calibration procedures resulted in reliable measurements as showed by the Bland-Altman measure agreement analysis. Discussion and conclusion The final device meets the goals of the original project and offers pressure measurements that are enough accurate for our studies on liver regeneration. In a wider contest the present article shows the potentiality of the open-source-hardware movement to increase the opportunities for scientists and educators.
Open AccessArduino-based lab equipment: building a multipurpose pressure transducer device
Background Lab equipments could be expensive and their cost can be unsustainable for scientist with limited financial resources. In order to overcome these impediments and to improve our experimental studies on liver resection in rat, a multipurpose pressure measurement device was project and realized using low cost components. Materials and Methods The device is based on an Arduino board, an easy-to-use and open-source microcontroller, that receives analog inputs from an instrumental amplifier connected to a disposable pressure traducer. The analogic inputs are converted to digital values and an LCD can visualize the pressure values calculated from the digital inputs. Programs has been written using C++ within the Arduino IDE, while the pressure data has been recorded on PC using data-logging freeware. Calibration has been performed using a water column as standard. Measure agreement was studied by comparing this device with a water column and with a standard clinical monitoring system. Results The final device it is handy and portable, it costs less the 20 euros and both the hardware and the software are easy modifiable. Calibration procedures resulted in reliable measurements as showed by the Bland-Altman measure agreement analysis. Discussion and conclusion The final device meets the goals of the original project and offers pressure measurements that are enough accurate for our studies on liver regeneration. In a wider contest the present article shows the potentiality of the open-source-hardware movement to increase the opportunities for scientists and educators.
- Open Access
- 1 October 2019
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2019 (10) , rjz275
Inferior vena cava resection without reconstruction for retroperitoneal malignancies
Inferior vena cava (IVC) involvement in retroperitoneal malignancies is a rare occurrence and radical surgery with major vascular resection represents the only potential curative treatment. IVC replacement after resection is still controversial and only small series and few prospective data are available. We report a series of three patients affected by retroperitoneal masses involving IVC treated with vena cava resection without replacement. All patients were treated by a radical R0 surgical procedure associated with infrarenal IVC resection and no reconstruction. Based on preoperative radiologic imaging and intraoperative findings, one patient also underwent right nephrectomy, while another patient underwent left renal vein ligation without nephrectomy. Neither early nor late severe post-operative complications related to the absence of IVC outflow were observed. Resection without replacement of the infrarenal IVC results in acceptable morbidity, thus specific risks related to the use of prosthetic grafts can be avoided.
- 1 October 2019
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2019 (10) , rjz275
Open AccessInferior vena cava resection without reconstruction for retroperitoneal malignancies
Inferior vena cava (IVC) involvement in retroperitoneal malignancies is a rare occurrence and radical surgery with major vascular resection represents the only potential curative treatment. IVC replacement after resection is still controversial and only small series and few prospective data are available. We report a series of three patients affected by retroperitoneal masses involving IVC treated with vena cava resection without replacement. All patients were treated by a radical R0 surgical procedure associated with infrarenal IVC resection and no reconstruction. Based on preoperative radiologic imaging and intraoperative findings, one patient also underwent right nephrectomy, while another patient underwent left renal vein ligation without nephrectomy. Neither early nor late severe post-operative complications related to the absence of IVC outflow were observed. Resection without replacement of the infrarenal IVC results in acceptable morbidity, thus specific risks related to the use of prosthetic grafts can be avoided.
- 1 October 2016
- Published by Elsevier in European Journal of Surgical Oncology
- Vol. 42 (10) , S215
Hipec in the management of metachronous peritoneal carcinomatosis: A single-center retrospective analysis
- 1 October 2016
- Published by Elsevier in European Journal of Surgical Oncology
- Vol. 42 (10) , S215
Hipec in the management of metachronous peritoneal carcinomatosis: A single-center retrospective analysis
- Open Access
- 5 January 2012
- Published by Hindawi Limited in Case Reports in Urology
- Vol. 2012, 1-3
CEUS Retrograde Cystography Is Helpful in Percutaneous Drainage of Complex Posttransplant Lymphocele
After monolateral dual kidney transplantation, a 69 years old male patient developed symptomatic lymphocele with mild hydroureteronephrosis, impaired renal function, and right inferior limb oedema. A percutaneous ultrasound-guided drainage of the fluid collection was planned, but the complex mutual relations between the collection and the renal hilus did not allow to identify a suitable route for a safe drainage insertion during conventional ultrasound examination. A retrograde cystography using echographic contrast agent was, therefore, performed, and it clarified the position of both ureters and the renal vessels, permitting an harmless ultrasound-guided percutaneous lymphocele drainage. In conclusion contrast-enhanced ultrasound retrograde cystography may be helpful in percutaneous drainage of complex posttransplant lymphocele.
- 5 January 2012
- Published by Hindawi Limited in Case Reports in Urology
- Vol. 2012, 1-3
Open AccessCEUS Retrograde Cystography Is Helpful in Percutaneous Drainage of Complex Posttransplant Lymphocele
After monolateral dual kidney transplantation, a 69 years old male patient developed symptomatic lymphocele with mild hydroureteronephrosis, impaired renal function, and right inferior limb oedema. A percutaneous ultrasound-guided drainage of the fluid collection was planned, but the complex mutual relations between the collection and the renal hilus did not allow to identify a suitable route for a safe drainage insertion during conventional ultrasound examination. A retrograde cystography using echographic contrast agent was, therefore, performed, and it clarified the position of both ureters and the renal vessels, permitting an harmless ultrasound-guided percutaneous lymphocele drainage. In conclusion contrast-enhanced ultrasound retrograde cystography may be helpful in percutaneous drainage of complex posttransplant lymphocele.
- Open Access
- 8 July 2011
- Published by Elsevier in Digestive and Liver Disease
- Vol. 43 (10) , 814-822
Early effects of portal flow modulation after extended liver resection in rat
- 8 July 2011
- Published by Elsevier in Digestive and Liver Disease
- Vol. 43 (10) , 814-822
Open AccessEarly effects of portal flow modulation after extended liver resection in rat
- Open Access
- 1 January 2011
- Published by Baishideng Publishing Group Inc. in World Journal of Gastrointestinal Surgery
- Vol. 3 (7) , 110-102
Hepatic flow optimization in full right split liver transplantation
Split liver transplantation for two adults offers a valuable opportunity to expand the donor pool for adult recipients. However, its application is mainly hampered by the physiological limits of these partial grafts. Small for size syndrome is a major concern during transplantation with partial graft and different techniques have been developed in living donor liver transplantation to prevent the graft dysfunction. Herein, we report the first application of synergic approaches to optimise the hepatic hemodynamic in a split liver graft for two adults. A Caucasian woman underwent liver transplantation for alcoholic cirrhosis (MELD 21) with a full right liver graft (S5-S8) without middle hepatic vein. Minor and accessory inferior hepatic veins were preserved by splitting the vena cava; V5 and V8 were anastomosed with a donor venous iliac patch. After implantation, a 16G catheter was advanced in the main portal trunk. Inflow modulation was achieved by splenic artery ligation. Intraportal infusion of PGE1 was started intraoperatively and discontinued after 5 d. Graft function was immediate with normalization of liver test after 7 d. Nineteen months after transplantation, liver function is normal and graft volume is 110% of the recipient standard liver volume. Optimisation of the venous outflow, inflow modulation and intraportal infusion of PGE1 may represent a valuable synergic strategy to prevent the graft dysfunction and it may increase the safety of split liver graft for two adults.
- 1 January 2011
- Published by Baishideng Publishing Group Inc. in World Journal of Gastrointestinal Surgery
- Vol. 3 (7) , 110-102
Open AccessHepatic flow optimization in full right split liver transplantation
Split liver transplantation for two adults offers a valuable opportunity to expand the donor pool for adult recipients. However, its application is mainly hampered by the physiological limits of these partial grafts. Small for size syndrome is a major concern during transplantation with partial graft and different techniques have been developed in living donor liver transplantation to prevent the graft dysfunction. Herein, we report the first application of synergic approaches to optimise the hepatic hemodynamic in a split liver graft for two adults. A Caucasian woman underwent liver transplantation for alcoholic cirrhosis (MELD 21) with a full right liver graft (S5-S8) without middle hepatic vein. Minor and accessory inferior hepatic veins were preserved by splitting the vena cava; V5 and V8 were anastomosed with a donor venous iliac patch. After implantation, a 16G catheter was advanced in the main portal trunk. Inflow modulation was achieved by splenic artery ligation. Intraportal infusion of PGE1 was started intraoperatively and discontinued after 5 d. Graft function was immediate with normalization of liver test after 7 d. Nineteen months after transplantation, liver function is normal and graft volume is 110% of the recipient standard liver volume. Optimisation of the venous outflow, inflow modulation and intraportal infusion of PGE1 may represent a valuable synergic strategy to prevent the graft dysfunction and it may increase the safety of split liver graft for two adults.
- 1 May 2010
- Published by Elsevier in Transplantation Proceedings
- Vol. 42 (4) , 1061-1065
Biochemical and Morphologic Effects After Extended Liver Resection in Rats: Preliminary Results
- 1 May 2010
- Published by Elsevier in Transplantation Proceedings
- Vol. 42 (4) , 1061-1065
Biochemical and Morphologic Effects After Extended Liver Resection in Rats: Preliminary Results
- Open Access
- 1 April 2010
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 29 (4) , 651-654
Sonographically guided jejunostomy replacement.
- 1 April 2010
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 29 (4) , 651-654
Open AccessSonographically guided jejunostomy replacement.
- 1 May 2009
- Published by Elsevier in Transplantation Proceedings
- Vol. 41 (4) , 1286-1289
A 20-Year Period of Orthotopic Liver Transplantation Activity in a Single Center: A Time Series Analysis Performed Using the R Statistical Software
- 1 May 2009
- Published by Elsevier in Transplantation Proceedings
- Vol. 41 (4) , 1286-1289
A 20-Year Period of Orthotopic Liver Transplantation Activity in a Single Center: A Time Series Analysis Performed Using the R Statistical Software