Pawel A. Penczek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Pawel A. Penczek has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Christian M.T. Spahn
Institut für Medizinische Physik und Biophysik, Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin, Germany
4 shared publicationsJames K. Stoops
Department of Biochemistry and Molecular Biology, and †Department of Pathology, The University of Texas-Houston Medical School, Houston, Texas 77030 USA; and ‡Institut für Biochemie, Charité Universitaetsmedizin, 10117 Berlin, Germany
2 shared publicationsJia Fang
Department of Biochemistry and Molecular Biology, The University of Texas Medical School, 6431 Fannin MSB 6.220, Houston, TX 77054, USA
2 shared publicationsMarek Kimmel
Rice University, Department of Statistics, 6100 Main Street, Houston, TX 77005, USA
2 shared publications- Stefan Raunser
Department of Structural Biochemistry, Max Planck Institute of Molecular Physiology
2 shared publications Zhengfan Yang
Department of Biochemistry and Molecular Biology, University of Texas-Houston Medical School, 6431 Fannin Street, MSB 6.218, Houston, TX 77030, USA
2 shared publications
Latest Publications
- Open Access
- 15 September 2020
- Published by International Union of Crystallography (IUCr) in IUCrJ
- Vol. 7 (6) , 995-1008
Reliable cryo-EM resolution estimation with modified Fourier shell correlation
A modified Fourier shell correlation (mFSC) methodology is introduced that is aimed at addressing two fundamental problems that mar the use of the FSC: the strong influence of mask-induced artifacts on resolution estimation and the lack of assessment of FSC uncertainties stemming from the inability to determine the associated number of degrees of freedom. It is shown that by simply changing the order of the steps in which the FSC is computed, the correlations induced by masking of the input data can be eliminated. In addition, to further reduce artifacts, a smooth Gaussian window function is used to outline the regions of reciprocal space within which the mFSC is computed. Next, it is shown that the number of degrees of freedom (ndf) of the system is approximated well by combining the ndf associated with the Gaussian window in reciprocal space with further reduction of the ndf owing to the use of the mask in real space. It is demonstrated through the application of the mFSC to both single-particle and helical structures that the mFSC yields reliable, mask-induced artifact-free results as a result of the introduced modifications. Since the adverse effect of the mask is eliminated, it also becomes possible to compute robust local resolutions both per voxel of a 3D map as well as, in a newly developed approach, per functional subunit, segment or even larger secondary element of the studied complex.
- 15 September 2020
- Published by International Union of Crystallography (IUCr) in IUCrJ
- Vol. 7 (6) , 995-1008
Open AccessReliable cryo-EM resolution estimation with modified Fourier shell correlation
A modified Fourier shell correlation (mFSC) methodology is introduced that is aimed at addressing two fundamental problems that mar the use of the FSC: the strong influence of mask-induced artifacts on resolution estimation and the lack of assessment of FSC uncertainties stemming from the inability to determine the associated number of degrees of freedom. It is shown that by simply changing the order of the steps in which the FSC is computed, the correlations induced by masking of the input data can be eliminated. In addition, to further reduce artifacts, a smooth Gaussian window function is used to outline the regions of reciprocal space within which the mFSC is computed. Next, it is shown that the number of degrees of freedom (ndf) of the system is approximated well by combining the ndf associated with the Gaussian window in reciprocal space with further reduction of the ndf owing to the use of the mask in real space. It is demonstrated through the application of the mFSC to both single-particle and helical structures that the mFSC yields reliable, mask-induced artifact-free results as a result of the introduced modifications. Since the adverse effect of the mask is eliminated, it also becomes possible to compute robust local resolutions both per voxel of a 3D map as well as, in a newly developed approach, per functional subunit, segment or even larger secondary element of the studied complex.
- Open Access
- 16 July 2018
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 7
Membrane insertion of α-xenorhabdolysin in near-atomic detail
α-Xenorhabdolysins (Xax) are α-pore-forming toxins (α-PFT) that form 1–1.3 MDa large pore complexes to perforate the host cell membrane. PFTs are used by a variety of bacterial pathogens to attack host cells. Due to the lack of structural information, the molecular mechanism of action of Xax toxins is poorly understood. Here, we report the cryo-EM structure of the XaxAB pore complex from Xenorhabdus nematophila and the crystal structures of the soluble monomers of XaxA and XaxB. The structures reveal that XaxA and XaxB are built similarly and appear as heterodimers in the 12–15 subunits containing pore, classifying XaxAB as bi-component α-PFT. Major conformational changes in XaxB, including the swinging out of an amphipathic helix are responsible for membrane insertion. XaxA acts as an activator and stabilizer for XaxB that forms the actual transmembrane pore. Based on our results, we propose a novel structural model for the mechanism of Xax intoxication.
- 16 July 2018
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 7
Open AccessMembrane insertion of α-xenorhabdolysin in near-atomic detail
α-Xenorhabdolysins (Xax) are α-pore-forming toxins (α-PFT) that form 1–1.3 MDa large pore complexes to perforate the host cell membrane. PFTs are used by a variety of bacterial pathogens to attack host cells. Due to the lack of structural information, the molecular mechanism of action of Xax toxins is poorly understood. Here, we report the cryo-EM structure of the XaxAB pore complex from Xenorhabdus nematophila and the crystal structures of the soluble monomers of XaxA and XaxB. The structures reveal that XaxA and XaxB are built similarly and appear as heterodimers in the 12–15 subunits containing pore, classifying XaxAB as bi-component α-PFT. Major conformational changes in XaxB, including the swinging out of an amphipathic helix are responsible for membrane insertion. XaxA acts as an activator and stabilizer for XaxB that forms the actual transmembrane pore. Based on our results, we propose a novel structural model for the mechanism of Xax intoxication.
- Top Cited Papers
A Primer to Single-Particle Cryo-Electron Microscopy
- 1 May 2014
- Published by Elsevier in Ultramicroscopy
- Vol. 140, 9-19
CTER—Rapid estimation of CTF parameters with error assessment
- 1 May 2014
- Published by Elsevier in Ultramicroscopy
- Vol. 140, 9-19
CTER—Rapid estimation of CTF parameters with error assessment
- Top Cited Papers
Iterative Stable Alignment and Clustering of 2D Transmission Electron Microscope Images
- 1 February 2012
- Published by Elsevier in Journal of Structural Biology
- Vol. 177 (2) , 302-313
Real-space processing of helical filaments in SPARX
- 1 February 2012
- Published by Elsevier in Journal of Structural Biology
- Vol. 177 (2) , 302-313
Real-space processing of helical filaments in SPARX
- 1 October 2009
- Published by Elsevier in Current Opinion in Structural Biology
- Vol. 19 (5) , 623-631
Exploring conformational modes of macromolecular assemblies by multiparticle cryo-EM
- 1 October 2009
- Published by Elsevier in Current Opinion in Structural Biology
- Vol. 19 (5) , 623-631
Exploring conformational modes of macromolecular assemblies by multiparticle cryo-EM
- Open Access
Heterogeneity of Large Macromolecular Complexes Revealed by 3D Cryo-EM Variance Analysis
- 1 August 2008
- Published by Elsevier in Ultramicroscopy
- Vol. 108 (9) , 959-969
Cryo-EM image alignment based on nonuniform fast Fourier transform
- 1 August 2008
- Published by Elsevier in Ultramicroscopy
- Vol. 108 (9) , 959-969
Cryo-EM image alignment based on nonuniform fast Fourier transform