Andrij Abramyuk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andrij Abramyuk has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Sergey V. Tokalov
Biological and Molecular Imaging, OncoRay - National Center for Radiation Research in Oncology, Medical Faculty Carl Gustav Carus, TU Dresden, Dresden, Germany
4 shared publications Klaus Zöphel
OncoRay – Center for Radiation Research in Oncology, Biological and Molecular Imaging, Medical Faculty and University Hospital Carl Gustav Carus, TU Dresden, Germany
3 shared publicationsNasreddin Abolmaali
OncoRay – Center for Radiation Research in Oncology, Biological and Molecular Imaging, Medical Faculty and University Hospital Carl Gustav Carus, TU Dresden, Germany
3 shared publicationsArne Koch
OncoRay - Molecular and Biological Imaging, Medical Faculty Carl Gustav Carus, Dresden University of Technology, Dresden, Germany
2 shared publicationsGunter Wolf
OncoRay – Center for Radiation Research in Oncology, Biological and Molecular Imaging, Medical Faculty and University Hospital Carl Gustav Carus, TU Dresden, Germany
2 shared publicationsKornelia Szluha Lazanyi
OncoRay - Center for Radiation Research in Oncology, Biological and Molecular Imaging, Medical Faculty and University Hospital Carl Gustav Carus, TU Dresden, Germany
2 shared publications
Latest Publications
- 31 December 2010
- Published by Elsevier in Lung Cancer
- Vol. 70 (3) , 280-285
Usefulness of dynamic contrast enhanced computed tomography in patients with non-small-cell lung cancer scheduled for radiation therapy
- 31 December 2010
- Published by Elsevier in Lung Cancer
- Vol. 70 (3) , 280-285
Usefulness of dynamic contrast enhanced computed tomography in patients with non-small-cell lung cancer scheduled for radiation therapy
- 1 September 2010
- Published by SAGE Publications in Acta Radiologica
- Vol. 51 (7) , 793-799
Preliminary assessment of dynamic contrast-enhanced CT implementation in pretreatment FDG-PET/CT for outcome prediction in head and neck tumors
Background: Recently published data show some controversy concerning the impact of [18F]-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) in predicting head and neck tumors (HNT) outcome. Assessment of tumor blood supply parameters using dynamic contrast-enhanced CT (DCE-CT) may deliver additional information concerning this important question. Purpose: To evaluate the contribution of DCE-CT implemented in pretherapeutic FDG-PET/CT protocol for prognosis prediction in patients with HNT. Material and Methods: Ten consecutive patients (median age 50 years, range 47–74 years) with histologically proven HNT underwent FDG-PET/CT with DCE-CT before treatment. FDG uptake was measured by maximum standardized uptake value (SUVmax). Relative tumor blood volume (rTBV) was determined from DCE-CT using Patlak analysis. Intratumoral heterogeneity was assessed by means of lacunarity analysis. Obtained values were compared with time-to-progression and overall survival. PET and DCE-CT images were compared on a pixel-by-pixel basis using Pearson coefficient of correlation. Results: Three patients with lower FDG uptake (SUVmax: 8±1) and five patients with higher FDG uptake (SUVmax: 15±4, P=0.004) were free of local recurrence for 24 months. Two groups of patients with significantly differing lower (group A: 0.37±0.02, n=6) and higher (group B: 0.52±0.01, n=4; P2=0.1). Conclusion: FDG-PET/CT and DCT-CT are complementary methods for surveillance assessment in patients with HNT. Implementation of DCE-CT in the pretreatment FDG-PET/CT protocol may improve tumor outcome prediction.
- 1 September 2010
- Published by SAGE Publications in Acta Radiologica
- Vol. 51 (7) , 793-799
Preliminary assessment of dynamic contrast-enhanced CT implementation in pretreatment FDG-PET/CT for outcome prediction in head and neck tumors
Background: Recently published data show some controversy concerning the impact of [18F]-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) in predicting head and neck tumors (HNT) outcome. Assessment of tumor blood supply parameters using dynamic contrast-enhanced CT (DCE-CT) may deliver additional information concerning this important question. Purpose: To evaluate the contribution of DCE-CT implemented in pretherapeutic FDG-PET/CT protocol for prognosis prediction in patients with HNT. Material and Methods: Ten consecutive patients (median age 50 years, range 47–74 years) with histologically proven HNT underwent FDG-PET/CT with DCE-CT before treatment. FDG uptake was measured by maximum standardized uptake value (SUVmax). Relative tumor blood volume (rTBV) was determined from DCE-CT using Patlak analysis. Intratumoral heterogeneity was assessed by means of lacunarity analysis. Obtained values were compared with time-to-progression and overall survival. PET and DCE-CT images were compared on a pixel-by-pixel basis using Pearson coefficient of correlation. Results: Three patients with lower FDG uptake (SUVmax: 8±1) and five patients with higher FDG uptake (SUVmax: 15±4, P=0.004) were free of local recurrence for 24 months. Two groups of patients with significantly differing lower (group A: 0.37±0.02, n=6) and higher (group B: 0.52±0.01, n=4; P2=0.1). Conclusion: FDG-PET/CT and DCT-CT are complementary methods for surveillance assessment in patients with HNT. Implementation of DCE-CT in the pretreatment FDG-PET/CT protocol may improve tumor outcome prediction.
- 1 June 2009
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 91 (3) , 399-404
Is pre-therapeutical FDG-PET/CT capable to detect high risk tumor subvolumes responsible for local failure in non-small cell lung cancer?
- 1 June 2009
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 91 (3) , 399-404
Is pre-therapeutical FDG-PET/CT capable to detect high risk tumor subvolumes responsible for local failure in non-small cell lung cancer?
- 1 January 2009
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 85 (9) , 747-751
Fusion of images in multistep analysis of neovascularisation
Purpose: The aim of our study was to develop a method for the fusion of images received after repeated staining of the same sample taking into account spatial differences between the images. Material and methods: A method of objective fusion performance was investigated on the images receiving during multistep staining of the xenograft tumour cross-sections. Results: It was shown that several images receiving from different steps of staining procedures may be successfully fused by fluorescent marking of slide position with Trout red blood cells before analysis. Conclusions: Proposed technique provides an accurate rigid fusion of light and fluorescent images receiving during multistep image analysis under microscope and may be applied for study of neovascularisation.
- 1 January 2009
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 85 (9) , 747-751
Fusion of images in multistep analysis of neovascularisation
Purpose: The aim of our study was to develop a method for the fusion of images received after repeated staining of the same sample taking into account spatial differences between the images. Material and methods: A method of objective fusion performance was investigated on the images receiving during multistep staining of the xenograft tumour cross-sections. Results: It was shown that several images receiving from different steps of staining procedures may be successfully fused by fluorescent marking of slide position with Trout red blood cells before analysis. Conclusions: Proposed technique provides an accurate rigid fusion of light and fluorescent images receiving during multistep image analysis under microscope and may be applied for study of neovascularisation.
- 1 January 2009
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 85 (9) , 781-786
Distribution of fluorescent microspheres in vascular space and parenchymal organs of intact nude rats
To assess kinetics of elimination of different sized microspheres (MS) from the blood pool and tendency of their distribution in parenchymal organs of intact nude rats. A mixture of 1 microm and 3 microm MS in phosphate-buffered saline was injected intravenously into eight rats under intraperitoneal anaesthesia. Blood samples were collected before, just after and in 2, 5 and 10 min after MS injection. Dynamics of MS elimination from blood pool was evaluated with flow cytometry. After euthanasia, histological sections were prepared and distributions of MS through the liver, spleen, kidney and lung were analysed with fluorescence microscopy and flow cytometry. The number of microspheres registered in the intravascular space showed a marked exponential decrease over time independent of MS size. Different amounts and proportions of 1 microm and 3 microm MS were revealed in lung, liver, spleen and kidneys of the rats. Most of 1 microm MS were localised in liver and spleen. In contrast, 3 microm MS were detected predominantly in lung. 1 microm and 3 microm MS may be assumed as free circulating particles only for a short period of time after injection. Their elimination kinetics seems to be tightly linked to specific tissue properties such a pulmonary vasoconstriction and phagocytosis.
- 1 January 2009
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 85 (9) , 781-786
Distribution of fluorescent microspheres in vascular space and parenchymal organs of intact nude rats
To assess kinetics of elimination of different sized microspheres (MS) from the blood pool and tendency of their distribution in parenchymal organs of intact nude rats. A mixture of 1 microm and 3 microm MS in phosphate-buffered saline was injected intravenously into eight rats under intraperitoneal anaesthesia. Blood samples were collected before, just after and in 2, 5 and 10 min after MS injection. Dynamics of MS elimination from blood pool was evaluated with flow cytometry. After euthanasia, histological sections were prepared and distributions of MS through the liver, spleen, kidney and lung were analysed with fluorescence microscopy and flow cytometry. The number of microspheres registered in the intravascular space showed a marked exponential decrease over time independent of MS size. Different amounts and proportions of 1 microm and 3 microm MS were revealed in lung, liver, spleen and kidneys of the rats. Most of 1 microm MS were localised in liver and spleen. In contrast, 3 microm MS were detected predominantly in lung. 1 microm and 3 microm MS may be assumed as free circulating particles only for a short period of time after injection. Their elimination kinetics seems to be tightly linked to specific tissue properties such a pulmonary vasoconstriction and phagocytosis.
- 1 May 2008
- Published by Springer Nature in Bulletin of Experimental Biology and Medicine
- Vol. 145 (5) , 626-628
Retrospective analysis of radiation load during examination of cancer patients by 68Ga-DOTATOC and 18F-FDG positron emission tomography
We present retrospective analysis of the results of examinations of 1338 cancer patients by 68Ga-DOTATOC and 18F-FDG positron emission and computer-aided tomography. It was shown that complex devices for positron emission and computer-aided tomography provide more informative data than individual methods. The protocol for examination by methods of positron emission and computer-aided tomography in each case is determined by clinical requirements and risk of extra exposure of the patient.
- 1 May 2008
- Published by Springer Nature in Bulletin of Experimental Biology and Medicine
- Vol. 145 (5) , 626-628
Retrospective analysis of radiation load during examination of cancer patients by 68Ga-DOTATOC and 18F-FDG positron emission tomography
We present retrospective analysis of the results of examinations of 1338 cancer patients by 68Ga-DOTATOC and 18F-FDG positron emission and computer-aided tomography. It was shown that complex devices for positron emission and computer-aided tomography provide more informative data than individual methods. The protocol for examination by methods of positron emission and computer-aided tomography in each case is determined by clinical requirements and risk of extra exposure of the patient.