XWXizeng Wu

Xizeng Wu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xizeng Wu has a total of 47 co-authors. Here are the top co-authors by number of shared publications:

  • Hong Liu

    Center for Bioengineering School of Electrical and Computer Engineering University of Oklahoma Norman, OK, USA

    24 shared publications
  • Aimin Yan

    Department of Radiology University of Alabama at Birmingham Birmingham, AL, USA

    16 shared publications
  • Hong Liu

    Advanced Medical Imaging Center and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019, USA

    9 shared publications
  • Aimin Yan

    Department of Radiology, University of Alabama at Birmingham, Birmingham, AL 35233, USA

    6 shared publications
  • Bin Zheng

    School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK, 73019, USA

    4 shared publications
  • Yuhua Li

    Center for Bioengineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK, USA

    4 shared publications

Latest Publications

  • Predicting fringe visibility in dual-phase grating interferometry with polychromatic X-ray sources

    by Aimin Yan, Xizeng Wu, Hong Liu

    Dual phase grating X-ray interferometry is radiation dose-efficient as compared to common Talbot-Lau grating interferometry. The authors developed a general quantitative theory to predict the fringe visibility in dual-phase grating X-ray interferometry with polychromatic X-ray sources. The derived formulas are applicable to setups with phase gratings of any phase modulation and with either monochromatic or polychromatic X-rays. Numerical simulations are presented to validate the derived formulas. The theory provides useful tools for design optimization of dual-phase grating X-ray interferometers.


  • Sample phase gradient and fringe phase shift in triple phase grating X-ray interferometry

    by Aimin Yan, Xizeng Wu, Hong Liu

    Triple phase grating X-ray interferometry is a promising new technique of grating based X-ray differential phase contrast imaging. Accurate retrieval of sample phase gradients from measured interference fringe shifts is a key task in X-ray interferometry. To fulfill this task in triple phase grating X-ray interferometry with monochromatic X-ray sources, the authors derived exact formulas relating sample phase gradient to fringe phase shift. These formulas not only provide a design optimization tool for triple phase grating interferometry, but also lay a foundation for quantitative phase contrast imaging.


  • Sample phase gradient and fringe phase shift in dual phase grating X-ray interferometry

    by Aimin Yan, Xizeng Wu, Hong Liu

    One of the key tasks in grating based x-ray phase contrast imaging is to accurately retrieve local phase gradients of a sample from measured intensity fringe shifts. To fulfill this task in dual phase grating interferometry, one needs to know the exact mathematical relationship between the two. In this work, using intuitive analysis of the sample-generated fringe shifts based on the beat pattern formation mechanism, the authors derived the formulas relating sample phase gradients to fringe phase shifts. These formulas provide also a design optimization tool for dual phase grating interferometry.


  • Open Access

    Clarification on generalized Lau condition for X-ray interferometers based on dual phase gratings

    by Aimin Yan, Xizeng Wu, Hong Liu

    To implement dual phase grating x-ray interferometry with x-ray tubes, one needs to incorporate an absorbing source grating. In order to attain good fringe visibility, the period of a source grating should be subject to a stringent condition. In literature some authors claim that the Lau-condition in Talbot-Lau interferometry can be literally transferred to dual phase grating interferometry. In this work we show that this statement in literature is incorrect. Instead, through an intuitive geometrical analysis of fringe formation, we derived a new generalized Lau-condition that provides a useful design tool for implementation of dual phase grating interferometry.


  • Open Access

    Impact of a single distance phase retrieval algorithm on spatial resolution in X-ray inline phase sensitive imaging

    by Muhammad U. Ghani, Bradley Gregory, Farid Omoumi, Bin Zheng, Aimin Yan, Xizeng Wu, Hong Liu

    A single-projection based phase retrieval method based on the phase attenuation duality principle (PAD) was used to compare the spatial resolution of the acquired phase sensitive and PAD processed phase retrieved images. An inline phase sensitive prototype was used to acquire the phase sensitive images. The prototype incorporates a micro-focus x-ray source and a flat panel detector with a 50 μ m pixel pitch. A phantom composed of a 2 cm thick 50–50 adipose-glandular mimicking slab sandwiched with a 0.82 cm thick slanted PMMA sharp edge was used. Phase sensitive image of the phantom was acquired at 120 kV, 3.35 mAs with a 16 μ m tube focal spot size under a geometric magnification (M) of 2.5. The PAD based method was applied to the acquired phase sensitive image for the retrieval of phase values. With necessary data processing, modulation transfer function (MTF) curves were determined for the estimation and comparison of the spatial resolution. The PAD processed phase retrieved values of the phantom were in good agreement with the theoretically calculated values. Phase sensitive images showed higher spatial resolution at all spatial frequencies compared to the phase retrieved images. It was noted that the high-frequency signal components in the retrieved image were suppressed that resulted in lower MTF values. When compared to the phase sensitive image, the cutoff resolution (10% MTF) for phase retrieved image dropped 32% from 15.6 lp/mm (32 μ m) to 10.6 lp/mm (47 μ m). The resolution offered by this phase sensitive prototype is radiographically enough to detect breast cancer.


  • Quantitative theory of X-ray interferometers based on dual phase grating: fringe period and visibility

    by Aimin Yan, Xizeng Wu, Hong Liu

    In most of grating x-ray interferometry one needs an absorbing grating as the analyzer to measure high-resolution interference fringes. Dual phase grating interferometry is a technique to get rid of the absorbing grating for radiation dose reduction. The authors present a quantitative theory of dual grating x-ray interferometry. The theory elucidates the fringe formation mechanism. The derived formulas of fringe period and fringe visibility provide useful tools for design optimization of dual phase grating interferometers.


  • Detectability comparison of simulated tumors in digital breast tomosynthesis using high-energy X-ray inline phase sensitive and commercial imaging systems

    by Muhammad U. Ghani, Molly D. Wong, Farid H. Omoumi, Bin Zheng, Laurie L. Fajardo, Aimin Yan, Xizeng Wu, Hong Liu


  • Open Access

    Beam hardening correction in polychromatic x-ray grating interferometry

    by Aimin Yan, Xizeng Wu, Hong Liu

    The beam hardening is one of the two causes of the fringe shift distortion in polychromatic X-ray grating interferometry. Based on the assumption of the uniform energy dependence, we developed a novel analytic approach to accurately retrieve the monochromatic attenuation function and fringe phase shift from the polychromatic measurement. This approach provides a useful tool for precise measurement of sample electron density distribution in X-ray grating interferometry.


  • Detectability comparison between a high energy x-ray phase sensitive and mammography systems in imaging phantoms with varying glandular-adipose ratios

    by Muhammad U Ghani, Molly D Wong, Di Wu, Bin Zheng, Laurie L Fajardo, Aimin Yan, Janis Fuh, Xizeng Wu, Hong Liu

    The objective of this study was to demonstrate the potential benefits of using high energy x-rays in comparison with the conventional mammography imaging systems for phase sensitive imaging of breast tissues with varying glandular-adipose ratios. This study employed two modular phantoms simulating the glandular (G) and adipose (A) breast tissue composition in 50 G–50 A and 70 G–30 A percentage densities. Each phantom had a thickness of 5 cm with a contrast detail test pattern embedded in the middle. For both phantoms, the phase contrast images were acquired using a micro-focus x-ray source operated at 120 kVp and 4.5 mAs, with a magnification factor ( M ) of 2.5 and a detector with a 50 µ m pixel pitch. The mean glandular dose delivered to the 50 G–50 A and 70 G–30 A phantom sets were 1.33 and 1.3 mGy, respectively. A phase retrieval algorithm based on the phase attenuation duality that required only a single phase contrast image was applied. Conventional low energy mammography images were acquired using GE Senographe DS and Hologic Selenia systems utilizing their automatic exposure control (AEC) settings. In addition, the automatic contrast mode (CNT) was also used for the acquisition with the GE system. The AEC mode applied higher dose settings for the 70 G–30 A phantom set. As compared to the phase contrast images, the dose levels for the AEC mode acquired images were similar while the dose levels for the CNT mode were almost double. The observer study, contrast-to-noise ratio and figure of merit comparisons indicated a large improvement with the phase retrieved images in comparison to the AEC mode images acquired with the clinical systems for both density levels. As the glandular composition increased, the detectability of smaller discs decreased with the clinical systems, particularly with the GE system, even at higher dose settings. As compared to the CNT mode (double dose) images, the observer study also indicated that the phase retrieved images provided similar or improved detection for all disc sizes except for the disk diameters of 2 mm and 1 mm for the 50 G–50 A phantom and 3 mm and 0.5 mm for the 70 G–30 A phantom. This study demonstrated the potential of utilizing a high energy phase sensitive x-ray imaging system to improve lesion detection and reduce radiation dose when imaging breast tissues with varying glandular compositions.


  • Open Access

    Polychromatic X-ray effects on fringe phase shifts in grating interferometry

    by Aimin Yan, Xizeng Wu, Hong Liu

    In order to quantitatively determine the projected electron densities of a sample, one needs to extract the monochromatic fringe phase shifts from the polychromatic fringe phase shifts measured in the grating interferometry with incoherent X-ray sources. In this work the authors propose a novel analytic approach that allows to directly compute the monochromatic fringe shifts from the polychromatic fringe shifts. This approach is validated with numerical simulations of several grating interferometry setups. This work provides a useful tool in quantitative imaging for biomedical and material science applications.