William W. Moses
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
William W. Moses has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
W.-S. Choong
Lawrence Berkeley National Laboratory, Berkeley, CA, USA
2 shared publicationsWilliam M. Higgins
Radiation Monitoring Devices, Watertown, MA 02472. telephone: 617-926-1167; fax: 617-926-9980
2 shared publicationsAlex Lempicki
ALEM Associates, Watertown, MA 02472 USA
1 shared publication- Austin Kuhn
Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104. telephone: 215-573-3958
1 shared publication - Benjamin W. Sturm
Lawrence LivermoreNational Laboratory, Livermore
1 shared publication C. Jackson
SensL, Cork, Ireland
1 shared publication
Latest Publications
- 14 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 57 (3) , 1570-1576
Optimization of a LSO-Based Detector Module for Time-of-Flight PET
We have explored methods for optimizing the timing resolution of an LSO-based detector module for a single-ring, “demonstration” time-of-flight PET camera. By maximizing the area that couples the scintillator to the PMT and minimizing the average path length that the scintillation photons travel, a single detector timing resolution of 218 ps fwhm is measured, which is considerably better than the ~385 ps fwhm obtained by commercial LSO or LYSO TOF detector modules. We explored different surface treatments (saw-cut, mechanically polished, and chemically etched) and reflector materials (Teflon tape, ESR, Lumirror, Melinex, white epoxy, and white paint), and found that for our geometry, a chemically etched surface had 5% better timing resolution than the saw-cut or mechanically polished surfaces, and while there was little dependence on the timing resolution between the various reflectors, white paint and white epoxy were a few percent better. Adding co-dopants to LSO shortened the decay time from 40 ns to ~30 ns but maintained the same or higher total light output. This increased the initial photoelectron rate and so improved the timing resolution by 15%. Using photomultiplier tubes with higher quantum efficiency (blue sensitivity index of 13.5 rather than 12) improved the timing resolution by an additional 5%. By choosing the optimum surface treatment (chemically etched), reflector (white paint), LSO composition (co-doped), and PMT (13.5 blue sensitivity index), the coincidence timing resolution of our detector module was reduced from 309 ps to 220 ps fwhm.
- 14 June 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 57 (3) , 1570-1576
Optimization of a LSO-Based Detector Module for Time-of-Flight PET
We have explored methods for optimizing the timing resolution of an LSO-based detector module for a single-ring, “demonstration” time-of-flight PET camera. By maximizing the area that couples the scintillator to the PMT and minimizing the average path length that the scintillation photons travel, a single detector timing resolution of 218 ps fwhm is measured, which is considerably better than the ~385 ps fwhm obtained by commercial LSO or LYSO TOF detector modules. We explored different surface treatments (saw-cut, mechanically polished, and chemically etched) and reflector materials (Teflon tape, ESR, Lumirror, Melinex, white epoxy, and white paint), and found that for our geometry, a chemically etched surface had 5% better timing resolution than the saw-cut or mechanically polished surfaces, and while there was little dependence on the timing resolution between the various reflectors, white paint and white epoxy were a few percent better. Adding co-dopants to LSO shortened the decay time from 40 ns to ~30 ns but maintained the same or higher total light output. This increased the initial photoelectron rate and so improved the timing resolution by 15%. Using photomultiplier tubes with higher quantum efficiency (blue sensitivity index of 13.5 rather than 12) improved the timing resolution by an additional 5%. By choosing the optimum surface treatment (chemically etched), reflector (white paint), LSO composition (co-doped), and PMT (13.5 blue sensitivity index), the coincidence timing resolution of our detector module was reduced from 309 ps to 220 ps fwhm.
- 1 October 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2009 (10823654) , 3491-3495
OpenPET: A flexible electronics system for radiotracer imaging
We present the design for OpenPET, an electronics readout system designed for prototype radiotracer imaging instruments. The critical requirements are that it have sufficient performance, channel count, channel density, and power consumption to service a complete camera, and yet be simple, flexible, and customizable enough to be used with almost any detector or camera design. A unique feature of this system is that each analog input is processed independently. Each input can be configured to accept signals of either polarity as well as either differential or ground referenced signals. Each signal is digitized by a continuously sampled ADC, which is processed by an FPGA to extract pulse height information. A leading edge discriminator creates a timing edge that is ¿time stamped¿ by a TDC implemented inside the FPGA. This digital information from each channel is sent to an FPGA that services 16 analog channels, and information from multiple channels is processed by this FPGA to perform logic for crystal lookup, DOI calculation, calibration, etc. As this processing is software controlled, it can be modified / customized easily. The system is be open source, meaning that all technical data (specifications, schematics and board layout files, source code, and instructions) will be publicly available.
- 1 October 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2009 (10823654) , 3491-3495
OpenPET: A flexible electronics system for radiotracer imaging
We present the design for OpenPET, an electronics readout system designed for prototype radiotracer imaging instruments. The critical requirements are that it have sufficient performance, channel count, channel density, and power consumption to service a complete camera, and yet be simple, flexible, and customizable enough to be used with almost any detector or camera design. A unique feature of this system is that each analog input is processed independently. Each input can be configured to accept signals of either polarity as well as either differential or ground referenced signals. Each signal is digitized by a continuously sampled ADC, which is processed by an FPGA to extract pulse height information. A leading edge discriminator creates a timing edge that is ¿time stamped¿ by a TDC implemented inside the FPGA. This digital information from each channel is sent to an FPGA that services 16 analog channels, and information from multiple channels is processed by this FPGA to perform logic for crystal lookup, DOI calculation, calibration, etc. As this processing is software controlled, it can be modified / customized easily. The system is be open source, meaning that all technical data (specifications, schematics and board layout files, source code, and instructions) will be publicly available.
- 1 January 2009
- Published by Springer Nature in MRS Proceedings
- Vol. 1164
Studies of Non-Proportionality in Alkali Halide and Strontium Iodide Scintillators Using SLYNCI
- 1 January 2009
- Published by Springer Nature in MRS Proceedings
- Vol. 1164
Studies of Non-Proportionality in Alkali Halide and Strontium Iodide Scintillators Using SLYNCI
- 1 October 2007
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 580 (2) , 919-924
Recent advances and future advances in time-of-flight PET
- 1 October 2007
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 580 (2) , 919-924
Recent advances and future advances in time-of-flight PET
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3 (10823654) , 1570-1573
CeBr3 for Time-of-Flight PET
In this paper we report on our investigation of the CeBr3 timing properties for Time-of-Flight (TOF) Positron Emission Tomography (PET). The TOF detection can significantly improve the signal-to-noise ratio in a reconstructed PET image and reduce the number of events necessary to do the reconstruction. In order to achieve TOF PET, a scintillator must have good timing resolution and good light output. We have investigated seven CeBr3 samples of different height, ranging from 3 mm to 37 mm. Two Hamamatsu R4998 fast photomultipliers were used for most experiments. Each sample was measured against a common standard (LaBr3:5%Ce) and the average timing resolution was found to be about 166 ps (fwhm). The two reference (LaBr3:5%Ce) crystals measured against each other gave the timing resolution of 170 ps. The best time resolution of 108 ps (fwhm) was measured for two CeBr3 samples (3 and 12 mm height). The longest sample (37 mm) provided 215 ps (fwhm). Two such samples working in coincidence would give about 252 ps timing resolution (fwhm, calculated). We have also measured TOF, where the source was moved between the two detectors and the change in a timing peak position was registered. The results show that a shift of 5 cm could be easily resolved by such a system.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3 (10823654) , 1570-1573
CeBr3 for Time-of-Flight PET
In this paper we report on our investigation of the CeBr3 timing properties for Time-of-Flight (TOF) Positron Emission Tomography (PET). The TOF detection can significantly improve the signal-to-noise ratio in a reconstructed PET image and reduce the number of events necessary to do the reconstruction. In order to achieve TOF PET, a scintillator must have good timing resolution and good light output. We have investigated seven CeBr3 samples of different height, ranging from 3 mm to 37 mm. Two Hamamatsu R4998 fast photomultipliers were used for most experiments. Each sample was measured against a common standard (LaBr3:5%Ce) and the average timing resolution was found to be about 166 ps (fwhm). The two reference (LaBr3:5%Ce) crystals measured against each other gave the timing resolution of 170 ps. The best time resolution of 108 ps (fwhm) was measured for two CeBr3 samples (3 and 12 mm height). The longest sample (37 mm) provided 215 ps (fwhm). Two such samples working in coincidence would give about 252 ps timing resolution (fwhm, calculated). We have also measured TOF, where the source was moved between the two detectors and the change in a timing peak position was registered. The results show that a shift of 5 cm could be easily resolved by such a system.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3 (10823654) , 1538-1540
Scintillation Properties of SrHfO/sub 3/:Ce/sup 3+/ and BaHfO/sub 3/:Ce/sup 3+/ Ceramics
In this paper we report on the scintillation properties of cerium doped strontium - and barium hafnate. Radioluminescence, pulse height, scintillation decay and timing spectra are presented. Radioluminescence spectra of SrHfO3:Ce3+ and BaHfO3:Ce3+ consist of a broad band due to Ce3+ emission peaking at 410 nm and 400 nm, respectively. The light yield of BaHfO3:Ce3+ and SrHfO3:Ce3+ transparent optical ceramic is approximately 40,000 photons/MeV when compared to a crystal of BGO. The principal decay time constant for SrHfO3:Ce3+ and BaHfO3:Ce3+ is 15 and 16 ns, respectively. A timing resolution of 276 ps (FWHM) was obtained with transparent optical ceramic of SrHfO3:Ce3+.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3 (10823654) , 1538-1540
Scintillation Properties of SrHfO/sub 3/:Ce/sup 3+/ and BaHfO/sub 3/:Ce/sup 3+/ Ceramics
In this paper we report on the scintillation properties of cerium doped strontium - and barium hafnate. Radioluminescence, pulse height, scintillation decay and timing spectra are presented. Radioluminescence spectra of SrHfO3:Ce3+ and BaHfO3:Ce3+ consist of a broad band due to Ce3+ emission peaking at 410 nm and 400 nm, respectively. The light yield of BaHfO3:Ce3+ and SrHfO3:Ce3+ transparent optical ceramic is approximately 40,000 photons/MeV when compared to a crystal of BGO. The principal decay time constant for SrHfO3:Ce3+ and BaHfO3:Ce3+ is 15 and 16 ns, respectively. A timing resolution of 276 ps (FWHM) was obtained with transparent optical ceramic of SrHfO3:Ce3+.