Sebastian G. Russo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Sebastian G. Russo has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Christoph Eich
Kinder- und Jugendkrankenhaus auf der Bult
3 shared publications - Michael Quintel
Department of Anesthesiology, University Medical Center Goettingen, 37075 Goettingen, Germany
3 shared publications A. Timmermann
Universitätsmedizin Göttingen
2 shared publicationsC. Eich
2 shared publications- Katrin Schwerdtfeger
Department of Anaesthesiology, University Hospital Göttingen, 370799 Göttingen, Germany
2 shared publications - Kay B. Leissner
Harvard Medical School, VA Boston Healthcare System, Anesthesiology and Perioperative Medicine
2 shared publications
Latest Publications
- 4 July 2017
- Published by Wiley in Pediatric Anesthesia
- Vol. 27 (8) , 816-820
Ultrasound assessment of gastric emptying after breakfast in healthy preschool children
Summary: Background: In current guidelines, 6 hours of fasting is recommended for solids to limit the risk of pulmonary aspiration during anesthesia in children. Ultrasonography has recently been introduced to evaluate gastric volumes in children in the context of preanesthetic fasting. Therefore, in this study, we firstly evaluated the precision of ultrasound assessment of gastric volume in an experimental setting and secondly studied gastric emptying times after a normal breakfast in healthy preschool children using ultrasound.Methods: In a preliminary experiment, a pear‐shaped elastic balloon was filled and emptied in 50 mL steps from 0 to 500 mL with water. After each step, the balloon antral area was measured using ultrasonography. Thereafter, gastric emptying was examined in healthy preschool children after normal breakfast by sonographic measurements of the gastric antral area in right lateral decubitus position at two consecutive timepoints. Correlation coefficients (Pearson, 95% CI) between the balloon antral area and the balloon volume or gastric antral area and fasting time were calculated and gastric emptying time was extrapolated by linear regression. Data are presented as mean (range).Results: In the balloon experiment, the balloon volume correlated significantly with the balloon antral area (63 measurements, r=.96, P<.0001, 95% CI 0.93 to 0.97). In the preschool child measurements, a total of 30 children (age 47 (36‐66) months) were included. The gastric antral area correlated significantly with fasting time (r=−.69, P<.0001, 95% CI −0.8 to −0.51). The first gastric antral area after breakfast was significantly higher when compared to the second gastric antral area before lunch (10.4 ± 3.7 (1.7‐17.8) vs 5.5 ± 2.6 (1.4‐11.8) cm2; mean difference −5.04, 95% CI −6.3 to −3.8, P<.0001). The calculated mean gastric emptying time was 236 minutes.Conclusion: The results of the balloon experiment showed a high correlation between balloon antral area and balloon volume. In the preschool child measurements, gastric antral area correlated with fasting time, and the mean gastric emptying time was lower than 4 hours after breakfast. These results support a more liberal perioperative fasting regimen after a light meal or breakfast in routine pediatric anesthesia.
- 4 July 2017
- Published by Wiley in Pediatric Anesthesia
- Vol. 27 (8) , 816-820
Ultrasound assessment of gastric emptying after breakfast in healthy preschool children
Summary: Background: In current guidelines, 6 hours of fasting is recommended for solids to limit the risk of pulmonary aspiration during anesthesia in children. Ultrasonography has recently been introduced to evaluate gastric volumes in children in the context of preanesthetic fasting. Therefore, in this study, we firstly evaluated the precision of ultrasound assessment of gastric volume in an experimental setting and secondly studied gastric emptying times after a normal breakfast in healthy preschool children using ultrasound.Methods: In a preliminary experiment, a pear‐shaped elastic balloon was filled and emptied in 50 mL steps from 0 to 500 mL with water. After each step, the balloon antral area was measured using ultrasonography. Thereafter, gastric emptying was examined in healthy preschool children after normal breakfast by sonographic measurements of the gastric antral area in right lateral decubitus position at two consecutive timepoints. Correlation coefficients (Pearson, 95% CI) between the balloon antral area and the balloon volume or gastric antral area and fasting time were calculated and gastric emptying time was extrapolated by linear regression. Data are presented as mean (range).Results: In the balloon experiment, the balloon volume correlated significantly with the balloon antral area (63 measurements, r=.96, P<.0001, 95% CI 0.93 to 0.97). In the preschool child measurements, a total of 30 children (age 47 (36‐66) months) were included. The gastric antral area correlated significantly with fasting time (r=−.69, P<.0001, 95% CI −0.8 to −0.51). The first gastric antral area after breakfast was significantly higher when compared to the second gastric antral area before lunch (10.4 ± 3.7 (1.7‐17.8) vs 5.5 ± 2.6 (1.4‐11.8) cm2; mean difference −5.04, 95% CI −6.3 to −3.8, P<.0001). The calculated mean gastric emptying time was 236 minutes.Conclusion: The results of the balloon experiment showed a high correlation between balloon antral area and balloon volume. In the preschool child measurements, gastric antral area correlated with fasting time, and the mean gastric emptying time was lower than 4 hours after breakfast. These results support a more liberal perioperative fasting regimen after a light meal or breakfast in routine pediatric anesthesia.
- 19 May 2016
- Published by Elsevier in Journal of Clinical Anesthesia
- Vol. 33, 330-336
A comparison between the GlideScope® classic and GlideScope® direct video laryngoscopes and direct laryngoscopy for nasotracheal intubation
- 19 May 2016
- Published by Elsevier in Journal of Clinical Anesthesia
- Vol. 33, 330-336
A comparison between the GlideScope® classic and GlideScope® direct video laryngoscopes and direct laryngoscopy for nasotracheal intubation
- Open Access
- 29 January 2016
- Published by Springer Nature in BMC Emergency Medicine
- Vol. 16 (1) , 8
Use of the GlideScope®-Ranger for pre-hospital intubations by anaesthesia trained emergency physicians – an observational study
Pre-hospital endotracheal intubation is more difficult than in the operating room (OR). Therefore, enhanced airway management devices such as video laryngoscopes may be helpful to improve the success rate of pre-hospital intubation. We describe the use of the Glidescope®-Ranger (GS-R) as an alternative airway tool used at the discretion of the emergency physician (EP) in charge. During a 3.5 year period, the GS-R was available to be used either as the primary or backup tool for pre-hospital intubation by anaesthesia trained EP with limited expertise using angulated videolaryngoscopes. During this period 672 patients needed pre-hospital intubation of which the GS-R was used in 56 cases. The overall GS-R success rate was 66 % (range of 34–100 % among EP). The reasons for difficulties or failure included inexperience of the EP with the GS-R, impaired view due to secretion, vomitus, blood or the inability to see the screen in very bright environment due to sunlight. Special expertise and substantial training is needed to successfully accomplish tracheal intubation with the GS-R in the pre-hospital setting. Providers inexperienced with DL as well as video-assisted intubation should not expect to be able to perform tracheal intubation easily just because a videolaryngoscope is available. Additionally, indirect laryngoscopy might be difficult or even impossible to achieve in the pre-hospital setting due to impeding circumstances such as blood, secretions or bright sun-light. Therefore, videolaryngoscopes, here the GS-R, should not be considered as the “Holy Grail” of endotracheal intubation, neither for the experts nor for inexperienced providers.
- 29 January 2016
- Published by Springer Nature in BMC Emergency Medicine
- Vol. 16 (1) , 8
Open AccessUse of the GlideScope®-Ranger for pre-hospital intubations by anaesthesia trained emergency physicians – an observational study
Pre-hospital endotracheal intubation is more difficult than in the operating room (OR). Therefore, enhanced airway management devices such as video laryngoscopes may be helpful to improve the success rate of pre-hospital intubation. We describe the use of the Glidescope®-Ranger (GS-R) as an alternative airway tool used at the discretion of the emergency physician (EP) in charge. During a 3.5 year period, the GS-R was available to be used either as the primary or backup tool for pre-hospital intubation by anaesthesia trained EP with limited expertise using angulated videolaryngoscopes. During this period 672 patients needed pre-hospital intubation of which the GS-R was used in 56 cases. The overall GS-R success rate was 66 % (range of 34–100 % among EP). The reasons for difficulties or failure included inexperience of the EP with the GS-R, impaired view due to secretion, vomitus, blood or the inability to see the screen in very bright environment due to sunlight. Special expertise and substantial training is needed to successfully accomplish tracheal intubation with the GS-R in the pre-hospital setting. Providers inexperienced with DL as well as video-assisted intubation should not expect to be able to perform tracheal intubation easily just because a videolaryngoscope is available. Additionally, indirect laryngoscopy might be difficult or even impossible to achieve in the pre-hospital setting due to impeding circumstances such as blood, secretions or bright sun-light. Therefore, videolaryngoscopes, here the GS-R, should not be considered as the “Holy Grail” of endotracheal intubation, neither for the experts nor for inexperienced providers.
- Open Access
- 24 July 2015
- Published by Springer Nature in BMC Medical Education
- Vol. 15 (1) , 1-8
Effect of CRM team leader training on team performance and leadership behavior in simulated cardiac arrest scenarios: a prospective, randomized, controlled study
Effective team leadership in cardiopulmonary resuscitation (CPR) is well recognized as a crucial factor influencing performance. Generally, leadership training focuses on task requirements for leading as well as non-leading team members. We provided crisis resource management (CRM) training only for designated team leaders of advanced life support (ALS) trained teams. This study assessed the impact of the CRM team leader training on CPR performance and team leader verbalization. Forty-five teams of four members each were randomly assigned to one of two study groups: CRM team leader training (CRM-TL) and additional ALS-training (ALS add-on). After an initial lecture and three ALS skill training tutorials (basic life support, airway management and rhythm recognition/defibrillation) of 90-min each, one member of each team was randomly assigned to act as the team leader in the upcoming CPR simulation. Team leaders of the CRM-TL groups attended a 90-min CRM-TL training. All other participants received an additional 90-min ALS skill training. A simulated CPR scenario was videotaped and analyzed regarding no-flow time (NFT) percentage, adherence to the European Resuscitation Council 2010 ALS algorithm (ADH), and type and rate of team leader verbalizations (TLV). CRM-TL teams showed shorter, albeit statistically insignificant, NFT rates compared to ALS-Add teams (mean difference 1.34 (95 % CI −2.5, 5.2), p = 0.48). ADH scores in the CRM-TL group were significantly higher (difference −6.4 (95 % CI −10.3, −2.4), p = 0.002). Significantly higher TLV proportions were found for the CRM-TL group: direct orders (difference −1.82 (95 % CI −2.4, −1.2), p < 0.001); undirected orders (difference −1.82 (95 % CI −2.8, −0.9), p < 0.001); planning (difference −0.27 (95 % CI −0.5, −0.05) p = 0.018) and task assignments (difference −0.09 (95 % CI −0.2, −0.01), p = 0.023). Training only the designated team leaders in CRM improves performance of the entire team, in particular guideline adherence and team leader behavior. Emphasis on training of team leader behavior appears to be beneficial in resuscitation and emergency medical course performance.
- 24 July 2015
- Published by Springer Nature in BMC Medical Education
- Vol. 15 (1) , 1-8
Open AccessEffect of CRM team leader training on team performance and leadership behavior in simulated cardiac arrest scenarios: a prospective, randomized, controlled study
Effective team leadership in cardiopulmonary resuscitation (CPR) is well recognized as a crucial factor influencing performance. Generally, leadership training focuses on task requirements for leading as well as non-leading team members. We provided crisis resource management (CRM) training only for designated team leaders of advanced life support (ALS) trained teams. This study assessed the impact of the CRM team leader training on CPR performance and team leader verbalization. Forty-five teams of four members each were randomly assigned to one of two study groups: CRM team leader training (CRM-TL) and additional ALS-training (ALS add-on). After an initial lecture and three ALS skill training tutorials (basic life support, airway management and rhythm recognition/defibrillation) of 90-min each, one member of each team was randomly assigned to act as the team leader in the upcoming CPR simulation. Team leaders of the CRM-TL groups attended a 90-min CRM-TL training. All other participants received an additional 90-min ALS skill training. A simulated CPR scenario was videotaped and analyzed regarding no-flow time (NFT) percentage, adherence to the European Resuscitation Council 2010 ALS algorithm (ADH), and type and rate of team leader verbalizations (TLV). CRM-TL teams showed shorter, albeit statistically insignificant, NFT rates compared to ALS-Add teams (mean difference 1.34 (95 % CI −2.5, 5.2), p = 0.48). ADH scores in the CRM-TL group were significantly higher (difference −6.4 (95 % CI −10.3, −2.4), p = 0.002). Significantly higher TLV proportions were found for the CRM-TL group: direct orders (difference −1.82 (95 % CI −2.4, −1.2), p < 0.001); undirected orders (difference −1.82 (95 % CI −2.8, −0.9), p < 0.001); planning (difference −0.27 (95 % CI −0.5, −0.05) p = 0.018) and task assignments (difference −0.09 (95 % CI −0.2, −0.01), p = 0.023). Training only the designated team leaders in CRM improves performance of the entire team, in particular guideline adherence and team leader behavior. Emphasis on training of team leader behavior appears to be beneficial in resuscitation and emergency medical course performance.
- Open Access
- 22 May 2014
- Published by Springer Nature in BMC Medical Education
- Vol. 14 (1) , 104
A prospective, blinded evaluation of a video-assisted ‘4-stage approach’ during undergraduate student practical skills training
Background: The 4-stage approach (4-SA) is used as a didactic method for teaching practical skills in international courses on resuscitation and the structured care of trauma patients. The aim of this study was to evaluate objective and subjective learning success of a video-assisted 4-SA in teaching undergraduate medical students. Methods: The participants were medical students learning the principles of the acute treatment of trauma patients in their multidiscipline course on emergency and intensive care medicine. The participants were quasi- randomly divided into two groups. The 4-SA was used in both groups. In the control group, all four steps were presented by an instructor. In the study group, the first two steps were presented as a video. At the end of the course a 5-minute objective, structured clinical examination (OSCE) of a simulated trauma patient was conducted. The test results were divided into objective results obtained through a checklist with 9 dichotomous items and the assessment of the global performance rated subjectively by the examiner on a Likert scale from 1 to 6. Results: 313 students were recruited; the results of 256 were suitable for analysis. The OSCE results were excellent in both groups and did not differ significantly (control group: median 9, interquantil range (IQR) 8–9, study group: median 9, IQR 8–9; p = 0.29). The global performance was rated significantly better for the study group (median 1, IQR 1–2 vs. median 2, IQR 1–3; p < 0.01). The relative knowledge increase, stated by the students in their evaluation after the course, was greater in the study group (85% vs. 80%). Conclusion: It is possible to employ video assistance in the classical 4-SA with comparable objective test results in an OSCE. The global performance was significantly improved with use of video assistance.
- 22 May 2014
- Published by Springer Nature in BMC Medical Education
- Vol. 14 (1) , 104
Open AccessA prospective, blinded evaluation of a video-assisted ‘4-stage approach’ during undergraduate student practical skills training
Background: The 4-stage approach (4-SA) is used as a didactic method for teaching practical skills in international courses on resuscitation and the structured care of trauma patients. The aim of this study was to evaluate objective and subjective learning success of a video-assisted 4-SA in teaching undergraduate medical students. Methods: The participants were medical students learning the principles of the acute treatment of trauma patients in their multidiscipline course on emergency and intensive care medicine. The participants were quasi- randomly divided into two groups. The 4-SA was used in both groups. In the control group, all four steps were presented by an instructor. In the study group, the first two steps were presented as a video. At the end of the course a 5-minute objective, structured clinical examination (OSCE) of a simulated trauma patient was conducted. The test results were divided into objective results obtained through a checklist with 9 dichotomous items and the assessment of the global performance rated subjectively by the examiner on a Likert scale from 1 to 6. Results: 313 students were recruited; the results of 256 were suitable for analysis. The OSCE results were excellent in both groups and did not differ significantly (control group: median 9, interquantil range (IQR) 8–9, study group: median 9, IQR 8–9; p = 0.29). The global performance was rated significantly better for the study group (median 1, IQR 1–2 vs. median 2, IQR 1–3; p < 0.01). The relative knowledge increase, stated by the students in their evaluation after the course, was greater in the study group (85% vs. 80%). Conclusion: It is possible to employ video assistance in the classical 4-SA with comparable objective test results in an OSCE. The global performance was significantly improved with use of video assistance.
- 1 March 2014
- Published by Springer Nature in Notfall + Rettungsmedizin
- Vol. 17 (2) , 105-112
Atemwegsmanagement bei Kindern in Notfallsituationen
- 1 March 2014
- Published by Springer Nature in Notfall + Rettungsmedizin
- Vol. 17 (2) , 105-112
Atemwegsmanagement bei Kindern in Notfallsituationen
- 19 August 2013
- Published by Wiley in Anaesthesia
- Vol. 68 (11) , 1124-1131
Transfer of airway skills from manikin training to patient: success of ventilation with facemask or LMA ‐Supreme TM by medical students
Summary: During emergency care, the ability to ventilate the patient's lungs is a crucial skill. Supraglottic airway devices have an established role in emergency care, and manikin trials have shown that placement is easy even for inexperienced users. However, there is current discussion as to what extent these results can be transferred to patients. We studied the transfer of skills learnt on a manikin to the clinical situation in novice medical students during their anaesthesia rotation. They were required to ventilate the lungs of a manikin using a facemask and then position a supraglottic airway device ( LMA ‐Supreme™) and ventilate the lungs. This process was then repeated on anaesthetised patients, with standard ventilator settings to assess adequacy of ventilation. Sixty‐three students participated in the manikin study. The success rate for ventilating the lungs was 100% for both devices, but the mean ( SD ) time to achieve successful ventilation was 27.8 (24.4) s with the facemask compared with 38.6 (22.0) s with the LMA ‐Supreme (p = 0.008). Fifty‐one of the students progressed to the second part of the study. In anaesthetised patients, the success rate for ventilating the lungs was lower for the facemask, 27/41 (66%) compared with the LMA ‐Supreme 37/41 (90%, p = 0.006). For 26 students who succeeded with both devices, the tidal volume was lower using the facemask, 431 (192) ml compared with the LMA ‐Supreme 751 (221) ml (p = 0.001), but the time to successful ventilation did not differ, 60.0 (26.2) s vs 57.3 (26.6) s (p = 0.71). We conclude that the results obtained in manikin studies cannot be transferred directly to the clinical situation and that guidelines should take this into account. Based on our findings, a supraglottic airway device may be preferable to a facemask as the first choice for inexperienced emergency caregivers.
- 19 August 2013
- Published by Wiley in Anaesthesia
- Vol. 68 (11) , 1124-1131
Transfer of airway skills from manikin training to patient: success of ventilation with facemask or LMA ‐Supreme TM by medical students
Summary: During emergency care, the ability to ventilate the patient's lungs is a crucial skill. Supraglottic airway devices have an established role in emergency care, and manikin trials have shown that placement is easy even for inexperienced users. However, there is current discussion as to what extent these results can be transferred to patients. We studied the transfer of skills learnt on a manikin to the clinical situation in novice medical students during their anaesthesia rotation. They were required to ventilate the lungs of a manikin using a facemask and then position a supraglottic airway device ( LMA ‐Supreme™) and ventilate the lungs. This process was then repeated on anaesthetised patients, with standard ventilator settings to assess adequacy of ventilation. Sixty‐three students participated in the manikin study. The success rate for ventilating the lungs was 100% for both devices, but the mean ( SD ) time to achieve successful ventilation was 27.8 (24.4) s with the facemask compared with 38.6 (22.0) s with the LMA ‐Supreme (p = 0.008). Fifty‐one of the students progressed to the second part of the study. In anaesthetised patients, the success rate for ventilating the lungs was lower for the facemask, 27/41 (66%) compared with the LMA ‐Supreme 37/41 (90%, p = 0.006). For 26 students who succeeded with both devices, the tidal volume was lower using the facemask, 431 (192) ml compared with the LMA ‐Supreme 751 (221) ml (p = 0.001), but the time to successful ventilation did not differ, 60.0 (26.2) s vs 57.3 (26.6) s (p = 0.71). We conclude that the results obtained in manikin studies cannot be transferred directly to the clinical situation and that guidelines should take this into account. Based on our findings, a supraglottic airway device may be preferable to a facemask as the first choice for inexperienced emergency caregivers.
- 1 March 2013
- Published by Georg Thieme Verlag KG in Journal Club AINS
- Vol. 2 (01) , 12-13
Intensivmedizin: Einfluss des Organversagens auf die Mortalität
Das Multiorganversagen ist die häufig letal verlaufende Endstrecke einer kritischen Erkrankung auf der Intensivstation. Der SOFA-Score (Sequential Organ Failure Assessment) wurde entwickelt, um quantitativ den Zeitverlauf von Organversagen zu erfassen. Veränderungen des SOFA-Scores haben prognostischen Wert und können die Effektivität therapeutischer Maßnahmen evaluieren helfen. Die vorliegende Arbeit zeigt, dass anhand von Veränderungen der Organfunktion in den ersten Tagen auf der Intensivstation der klinische Verlauf kritisch kranker Patienten abgeschätzt werden kann.
- 1 March 2013
- Published by Georg Thieme Verlag KG in Journal Club AINS
- Vol. 2 (01) , 12-13
Intensivmedizin: Einfluss des Organversagens auf die Mortalität
Das Multiorganversagen ist die häufig letal verlaufende Endstrecke einer kritischen Erkrankung auf der Intensivstation. Der SOFA-Score (Sequential Organ Failure Assessment) wurde entwickelt, um quantitativ den Zeitverlauf von Organversagen zu erfassen. Veränderungen des SOFA-Scores haben prognostischen Wert und können die Effektivität therapeutischer Maßnahmen evaluieren helfen. Die vorliegende Arbeit zeigt, dass anhand von Veränderungen der Organfunktion in den ersten Tagen auf der Intensivstation der klinische Verlauf kritisch kranker Patienten abgeschätzt werden kann.
- 1 December 2012
- Published by Springer Nature in Der Anaesthesist
- Vol. 61 (12) , 1017-1026
Videolaryngoskopie olé!
In den letzten Jahren haben verschiedene Videolaryngoskopiesysteme Einzug in die anästhesiologische Praxis gehalten. Aufgrund der technischen Konzeption dieser Systeme (stärker angulierte Spatelform bzw. nahe der Spatelspitze befindliche Kameraoptik) ist die Sicht auf die laryngealen Strukturen sowohl bei normalen als auch bei schwierigen Laryngoskopieverhältnissen häufig besser als bei der direkten Laryngoskopie. Gleichzeitig bietet die Visualisierung des Intubationsvorgangs gute Möglichkeiten in Ausbildung und Supervision. Mit der zunehmenden Verbreitung der Videolaryngoskopie könnten die direkte laryngoskopische und die flexible fiberoptische Intubation in den Hintergrund gedrängt werden. Dieser Beitrag beschreibt die aktuellen Entwicklungen und diskutiert, warum die Expertise in der direkten Laryngoskopie und in der Intubation mithilfe der flexiblen Fiberoptik trotz zunehmender Verbreitung der Videolaryngoskopie v. a. für Experten im Bereich der Atemwegssicherung aufrechterhalten werden sollte. A number of video laryngoscopy systems have been introduced into anesthetic practice in recent years. Due to the technical concepts of these systems exposure of the laryngeal structures is usually better than with direct laryngoscopy, both in normal airways as well as in those that are difficult to manage. With the increasing use of video laryngoscopy it seems as if direct laryngoscopy and flexible fibrescopic intubation are at risk of becoming redundant. This article describes current developments and discusses why expertise in direct laryngoscopy and flexible fibrescopic intubation should be maintained, particularly by experts in airway management. The English full text version of this article is available in SpringerLink (under “Supplemental”).
- 1 December 2012
- Published by Springer Nature in Der Anaesthesist
- Vol. 61 (12) , 1017-1026
Videolaryngoskopie olé!
In den letzten Jahren haben verschiedene Videolaryngoskopiesysteme Einzug in die anästhesiologische Praxis gehalten. Aufgrund der technischen Konzeption dieser Systeme (stärker angulierte Spatelform bzw. nahe der Spatelspitze befindliche Kameraoptik) ist die Sicht auf die laryngealen Strukturen sowohl bei normalen als auch bei schwierigen Laryngoskopieverhältnissen häufig besser als bei der direkten Laryngoskopie. Gleichzeitig bietet die Visualisierung des Intubationsvorgangs gute Möglichkeiten in Ausbildung und Supervision. Mit der zunehmenden Verbreitung der Videolaryngoskopie könnten die direkte laryngoskopische und die flexible fiberoptische Intubation in den Hintergrund gedrängt werden. Dieser Beitrag beschreibt die aktuellen Entwicklungen und diskutiert, warum die Expertise in der direkten Laryngoskopie und in der Intubation mithilfe der flexiblen Fiberoptik trotz zunehmender Verbreitung der Videolaryngoskopie v. a. für Experten im Bereich der Atemwegssicherung aufrechterhalten werden sollte. A number of video laryngoscopy systems have been introduced into anesthetic practice in recent years. Due to the technical concepts of these systems exposure of the laryngeal structures is usually better than with direct laryngoscopy, both in normal airways as well as in those that are difficult to manage. With the increasing use of video laryngoscopy it seems as if direct laryngoscopy and flexible fibrescopic intubation are at risk of becoming redundant. This article describes current developments and discusses why expertise in direct laryngoscopy and flexible fibrescopic intubation should be maintained, particularly by experts in airway management. The English full text version of this article is available in SpringerLink (under “Supplemental”).
- 1 December 2012
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 109 (6) , 996-1004
Magnetic resonance imaging study of the in vivo position of the extraglottic airway devices i-gel™ and LMA-Supreme™ in anaesthetized human volunteers
Exact information on the anatomical in situ position of extraglottic airway (EGA) devices is lacking. We used magnetic resonance imaging (MRI) to visualize the positions of the i-gel™ and the LMA-Supreme™ (LMA-S) relative to skeletal and soft-tissue structures. Twelve volunteers participated in this randomized, prospective, cross-over study. Native MRI scans were performed before induction of anaesthesia. Anaesthesia was induced, and the two EGAs were inserted in a randomized sequence. Their positions were assessed functionally, optically by fibrescope, and with MRI scans of the head and neck. The LMA-S protruded deeper into the upper oesophageal sphincter than the i-gel™ (P<0.001). Both devices reduced the area of the glottic aperture (P<0.001), and the LMA-S had the largest effect (P=0.049). The i-gel™ significantly compressed the tongue (P<0.001). Both devices displaced the hyoid bone ventrally (P<0.001); the i-gel™ to a greater degree (P=0.029). The fibreoptically determined position of the bowl of the devices was identical. The LMA-S and i-gel™ differ significantly with regard to in situ position and spatial relationship with adjacent structures assessed by MRI, despite similar clinical and fibreoptical findings. This could be relevant with regard to risk of aspiration, glottic narrowing, and airway resistance and soft-tissue morbidity.
- 1 December 2012
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 109 (6) , 996-1004
Magnetic resonance imaging study of the in vivo position of the extraglottic airway devices i-gel™ and LMA-Supreme™ in anaesthetized human volunteers
Exact information on the anatomical in situ position of extraglottic airway (EGA) devices is lacking. We used magnetic resonance imaging (MRI) to visualize the positions of the i-gel™ and the LMA-Supreme™ (LMA-S) relative to skeletal and soft-tissue structures. Twelve volunteers participated in this randomized, prospective, cross-over study. Native MRI scans were performed before induction of anaesthesia. Anaesthesia was induced, and the two EGAs were inserted in a randomized sequence. Their positions were assessed functionally, optically by fibrescope, and with MRI scans of the head and neck. The LMA-S protruded deeper into the upper oesophageal sphincter than the i-gel™ (P<0.001). Both devices reduced the area of the glottic aperture (P<0.001), and the LMA-S had the largest effect (P=0.049). The i-gel™ significantly compressed the tongue (P<0.001). Both devices displaced the hyoid bone ventrally (P<0.001); the i-gel™ to a greater degree (P=0.029). The fibreoptically determined position of the bowl of the devices was identical. The LMA-S and i-gel™ differ significantly with regard to in situ position and spatial relationship with adjacent structures assessed by MRI, despite similar clinical and fibreoptical findings. This could be relevant with regard to risk of aspiration, glottic narrowing, and airway resistance and soft-tissue morbidity.