Roberto P. Benzo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Roberto P. Benzo has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Frank C. Sciurba
Division of Pulmonary, Allergy, and Critical Care Medicine, University of Pittsburgh, Pittsburgh, PA, USA
3 shared publications Albert Hofman
Harvard School of Public Health, Boston, MA
1 shared publicationGeorge A. Kelley
Department of Community Medicine, West Virginia University, Morgantown USA
1 shared publicationLaura Recchi
Department of Medicine, West Virginia University, Morgantown USA
1 shared publicationSanjay A. Patel
1 shared publication- Sanjay A. Patel
Division of Pulmonary, Allergy, and Critical Care Medicine, University of Pittsburgh, Pittsburgh, PA, USA
1 shared publication
Latest Publications
- 1 August 2007
- Published by Elsevier in Respiratory Medicine
- Vol. 101 (8) , 1790-1797
Complications of lung resection and exercise capacity: A meta-analysis
- 1 August 2007
- Published by Elsevier in Respiratory Medicine
- Vol. 101 (8) , 1790-1797
Complications of lung resection and exercise capacity: A meta-analysis
- 1 March 2007
- Published by Wolters Kluwer Health in Journal of Cardiopulmonary Rehabilitation and Prevention
- Vol. 27 (2) , 61-64
Pulmonary Rehabilitation in Lung Cancer
- 1 March 2007
- Published by Wolters Kluwer Health in Journal of Cardiopulmonary Rehabilitation and Prevention
- Vol. 27 (2) , 61-64
Pulmonary Rehabilitation in Lung Cancer
- 1 January 2007
- Published by Taylor & Francis in COPD: Journal of Chronic Obstructive Pulmonary Disease
- Vol. 4 (2) , 107-112
Activity Monitoring and Energy Expenditure in COPD Patients: A Validation Study
There is increasing interest in the objective measurement of physical activity in chronic obstructive pulmonary disease (COPD) patients due to the close relationship between physical activity level, health, disability and mortality. We aimed to (a) determine the validity and reproducibility of an activity monitor that integrates accelerometry with multiple physiologic sensors in the determination of energy expenditure in COPD subjects and (b) to document the independent contribution of the additional physiologic sensors to accelerometry measures in improving true energy expenditure determination. Eight subjects (4 male, FEV1 56.4 ± 14.1%, RV 145.0 ± 75.7%) performed 2 separate 6-minute walk and 2 incremental shuttle walk exercise tests. Energy expenditure was calculated during each exercise test using the physiologic activity monitor and compared to a validated exhaled breath metabolic system. Test-retest reproducibility of physiologic activity monitor during the walking tests was comparable to an exhaled breath metabolic system. Physiologic sensor data significantly improved the explained variance in energy expenditure determination (r2 = 0.88) compared to accelerometry data alone (r2 = 0.68). This physiologic activity monitor provides a valid and reproducible estimate of energy expenditure during slow to moderate paced walking in a laboratory setting and represents an objective method to assess activity in COPD subjects.
- 1 January 2007
- Published by Taylor & Francis in COPD: Journal of Chronic Obstructive Pulmonary Disease
- Vol. 4 (2) , 107-112
Activity Monitoring and Energy Expenditure in COPD Patients: A Validation Study
There is increasing interest in the objective measurement of physical activity in chronic obstructive pulmonary disease (COPD) patients due to the close relationship between physical activity level, health, disability and mortality. We aimed to (a) determine the validity and reproducibility of an activity monitor that integrates accelerometry with multiple physiologic sensors in the determination of energy expenditure in COPD subjects and (b) to document the independent contribution of the additional physiologic sensors to accelerometry measures in improving true energy expenditure determination. Eight subjects (4 male, FEV1 56.4 ± 14.1%, RV 145.0 ± 75.7%) performed 2 separate 6-minute walk and 2 incremental shuttle walk exercise tests. Energy expenditure was calculated during each exercise test using the physiologic activity monitor and compared to a validated exhaled breath metabolic system. Test-retest reproducibility of physiologic activity monitor during the walking tests was comparable to an exhaled breath metabolic system. Physiologic sensor data significantly improved the explained variance in energy expenditure determination (r2 = 0.88) compared to accelerometry data alone (r2 = 0.68). This physiologic activity monitor provides a valid and reproducible estimate of energy expenditure during slow to moderate paced walking in a laboratory setting and represents an objective method to assess activity in COPD subjects.