YCYung Sung Cheng

Yung Sung Cheng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yung Sung Cheng has a total of 89 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effects of size and shape on filtration of TiO2 nanoparticles

    by Yung Sung Cheng, Yue Zhou

    Titanium dioxide (TiO2) is one of the most widely used nanoscale materials to date and could result in human exposures. The main objective of this study was to perform detailed characterization of TiO2 agglomerate particles and how these properties influence particle penetration in a screen filter. Transmission electron microscope (TEM) photos showed compact agglomerates of nanoscale primary particles. The projected area diameter was close to the mobility diameter, where the length was about 25% larger than the mobility diameter. The mean aspect ratio of TiO2 agglomerate was constant between 1.39 and 1.55. Using the tandem differential mobility analyzer-aerosol particles mass analyzer (DMA-APM) technique, we were able to measure aerodynamic diameter, mass, and fractal dimension. The value of fractal dimension based on mass and mobility diameter was 2.8. Penetration of classified TiO2 particles through a screen filter was measured. Penetration increased with increasing mobility diameter and flow rate indicating that diffusion and interception were the main filtration mechanism. The measured physical dimensions, mobility diameter, and aerodynamic diameter were used in a single-fiber filtration theory for the fan model filter to predict the penetration of TiO2 particles. The interception parameter was the key to estimate the penetration. Experimental penetration data were in best agreement with the model in which the maximum length was used to calculate the interception model. This result was consistent with the assumption that the rotation time of a non-spherical particle of small aspect ratio was much less than the transport time for the particle to pass through the filter fiber. © 2017 American Association for Aerosol Research


  • Mechanisms of Pharmaceutical Aerosol Deposition in the Respiratory Tract

    by Yung Sung Cheng

    Aerosol delivery is noninvasive and is effective in much lower doses than required for oral administration. Currently, there are several types of therapeutic aerosol delivery systems, including the pressurized metered-dose inhaler, the dry powder inhaler, the medical nebulizer, the solution mist inhaler, and the nasal sprays. Both oral and nasal inhalation routes are used for the delivery of therapeutic aerosols. Following inhalation therapy, only a fraction of the dose reaches the expected target area. Knowledge of the amount of drug actually deposited is essential in designing the delivery system or devices to optimize the delivery efficiency to the targeted region of the respiratory tract. Aerosol deposition mechanisms in the human respiratory tract have been well studied. Prediction of pharmaceutical aerosol deposition using established lung deposition models has limited success primarily because they underestimated oropharyngeal deposition. Recent studies of oropharyngeal deposition of several drug delivery systems identify other factors associated with the delivery system that dominates the transport and deposition of the oropharyngeal region. Computational fluid dynamic simulation of the aerosol transport and deposition in the respiratory tract has provided important insight into these processes. Investigation of nasal spray deposition mechanisms is also discussed.


  • Thoracic Fraction of Inhaled Fiber Aerosol

    by Yung Sung Cheng, Wei-Chung Su

    Size-selective sampling is a health-related method to collect airborne particles based on penetration of inhaled particles into different regions of the human respiratory tract; thus, it is the most relevant sampling method to correlate health risks with occupational exposure. The current practice of sampling asbestos and other fibers is not a size-selective method. The thoracic size fraction, defined as the portion of inhaled particles that can penetrate through the larynx, has been suggested as the most relevant size-selective sampling method for fiber aerosol. The thoracic fraction is based on 1-deposition of inhaled spherical particles in the human extrathoracic airways for mouth breathing and corrected for the particle inhalability. There is no comparable information for fiber aerosols; therefore, there is no technical basis to ascertain whether the current thoracic fraction definition is suitable for fiber aerosols. No human data are available from controlled experiments of inhaled fiber aerosols for the obvious reason that most fiber materials are potentially hazardous when inhaled. Our approach was to measure penetration of fiber aerosol in realistic human oropharyngeal airway replicas and to compare that with data from spherical particles. We showed that realistic human oral airway replicas (including the oral cavity, pharynx, and larynx regions) provided useful spherical and fiber particle deposition in the human head airway. These data could be used to test the thoracic fraction curves. The spherical penetration is in agreement with human in vivo data used to establish the thoracic fraction curve. Fiber penetrations through the larynx of two human oral airway replicas were higher than those for spherical particles for the same aerodynamic diameter using the same replicas. The thoracic curve as defined for spherical particles, therefore, may not include some fibers that could penetrate to the thoracic region.


  • Letter to the Editor

    by Yung Sung Cheng, Yue Zhou

    (2011). Letter to the Editor. Journal of Occupational and Environmental Hygiene: Vol. 8, No. 9, pp. D88-D88.

  • Dermal and ocular exposure systems for the development of models of sulfur mustard-induced injury

    by Waylon M. Weber, Dean A. Kracko, Mericka R. Lehman, Christopher E. Cox, Yung-Sung Cheng, Gary R. Grotendorst, Jacob D. McDonald

    Sulfur mustard (SM) is a chemical threat agent for which the effects have no current treatment. Due to the ease of synthesis and dispersal of this material, the need to develop therapeutics is evident. The present article details the techniques used to develop SM laboratory exposure systems for the development of animal models of ocular and dermal injury. These models are critical to enable evaluation of SM injury and therapeutics against that injury. Iterative trials were conducted to optimize dermal and ocular injury models in guinea pigs and rabbits respectively. The goal was a homogeneous and diffuse ocular and dermal injury that compares to the human injury. Dermal exposures were conducted by either a flow-past or static vapor cup system. Ocular exposures were conducted by a static exposure system. Ocular and dermal exposures were conducted with vaporized SM. Vapor concentrations increased with time in the dermal and ocular exposure systems but were stable with varying amounts of applied SM. A dermal deposition estimation study was also conducted. Deposited volumes increased with exposure time.


  • Exposing Animals to Oxidant Gases: Nose Only vs. Whole Body

    by Yung Sung Cheng, Larry Bowen, Roy J. Rando, Edward M. Postlethwait, Giuseppe L. Squadrito, Sadis Matalon

    Inhalation experiments using laboratory animals are performed under controlled conditions to assess the toxicity of and to investigate interventional strategies to ameliorate injury resulting from oxidant gas exposures. A variety of dynamic inhalation exposure systems that use whole-body or nose-only exposure chambers have been developed for rodents. In a whole-body exposure chamber, the animals are immersed in the test atmosphere, whereas in nose-only or head-only exposure systems, exposures are localized primarily to the head and/or nasal regions. There are advantages and disadvantages with both types of exposure approaches. Considerations such as animal number, exposure duration, end points of study, and availability of test material should influence the selection of a particular exposure system.


  • Characterization of Florida red tide aerosol and the temporal profile of aerosol concentration

    by Yung Sung Cheng, Yue Zhou, Richard H. Pierce, Mike Henry, Daniel G. Baden


  • Personal Exposure to Aerosolized Red Tide Toxins (Brevetoxins)

    by Yung Sung Cheng, Yue Zhou, Jerome Naar, C. Mitch Irvin, Wei-Chung Su, Lora E. Fleming, Barbara Kirkpatrick, Richard H. Pierce, Lorraine C. Backer, Daniel G. Baden

    Florida red tides occur annually in the Gulf of Mexico from blooms of the marine dinoflagellate, Karenia brevis, which produces highly potent natural polyether toxins, brevetoxins. Several epidemiologic studies have demonstrated that human exposure to red tide aerosol could result in increased respiratory symptoms. Environmental monitoring of aerosolized brevetoxins was performed using a high-volume sampler taken hourly at fixed locations on Siesta Beach, Florida. Personal exposure was monitored using personal air samplers and taking nasal swab samples from the subjects who were instructed to spend 1 hr on Sarasota Beach during two sampling periods of an active Florida red tide event in March 2005, and in May 2008 when there was no red tide. Results showed that the aerosolized brevetoxins from the personal sampler were in modest agreement with the environmental concentration taken from a high-volume sampler. Analysis of nasal swab samples for brevetoxins demonstrated 68% positive samples in the March 2005 sampling period when air concentrations of brevetoxins were between 50 to 120 ng/m3 measured with the high-volume sampler. No swab samples showed detectable levels of brevetoxins in the May 2008 study, when all personal samples were below the limit of detection. However, there were no statistical correlations between the amounts of brevetoxins detected in the swab samples with either the environmental or personal concentration. Results showed that the personal sample might provide an estimate of individual exposure level. Nasal swab samples showed that brevetoxins indeed were inhaled and deposited in the nasal passage during the March 2005 red tide event.


  • PHYSICOCHEMICAL CHARACTERIZATION OF CAPSTONE DEPLETED URANIUM AEROSOLS II: PARTICLE SIZE DISTRIBUTIONS AS A FUNCTION OF TIME

    by Yung Sung Cheng, Judson L. Kenoyer, Raymond A. Guilmette, Mary Ann Parkhurst

    The Capstone Depleted Uranium (DU) Aerosol Study, which generated and characterized aerosols containing DU from perforation of armored vehicles with large-caliber DU penetrators, incorporated a sampling protocol to evaluate particle size distributions. Aerosol particle size distribution is an important parameter that influences aerosol transport and deposition processes as well as the dosimetry of the inhaled particles. These aerosols were collected on cascade impactor substrates using a pre-established time sequence following the firing event to analyze the uranium concentration and particle size of the aerosols as a function of time. The impactor substrates were analyzed using proportional counting, and the derived uranium content of each served as input to the evaluation of particle size distributions. Activity median aerodynamic diameters (AMADs) of the particle size distributions were evaluated using unimodal and bimodal models. The particle size data from the impactor measurements were quite variable. Most size distributions measured in the test based on activity had bimodal size distributions with a small particle size mode in the range of between 0.2 and 1.2 μm and a large size mode between 2 and 15 μm. In general, the evolution of particle size over time showed an overall decrease of average particle size from AMADs of 5 to 10 μm shortly after perforation to around 1 μm at the end of the 2-h sampling period. The AMADs generally decreased over time because of settling. Additionally, the median diameter of the larger size mode decreased with time. These results were used to estimate the dosimetry of inhaled DU particles.


  • Lung Deposition of Droplet Aerosols in Monkeys

    by Y. S. Cheng, H. Irshad, P. Kuehl, T. D. Holmes, R. Sherwood, C. H. Hobbs

    Nonhuman primates are often the animal models of choice to study the infectivity and therapy of inhaled infectious agents. Most animal models for inhaled infectious diseases use aerosol/droplets generated by an atomization technique such as a Collison nebulizer that produces particles in the size range of 1 to 3 μm in diameter. There are few data in the literature on deposition patterns in monkeys. Our study was designed to measure the deposition pattern in monkeys using droplets having diameters of 2 and 5 μm using an exposure system designed to expose monkeys to aerosols of infectious agents. Six cynomolgus monkeys were exposed to droplets. The aerosol solution was generated from a Vero cell supernate containing DMEM + 10% fetal bovine serum tagged with Tc-99m radiolabel. Collison and Retec nebulizers were used to generate small and large droplets, respectively. The particle size (as determined from a cascade impactor) showed an activity median aerodynamic diameter (AMAD) of 2.3 and 5.1 μm for the Collison and Retec nebulizer, respectively. The animals were anesthetized, placed in a plethysmography box, and exposed to the aerosol. The deposition pattern was determined using a gamma camera. Deposition in the head airways was 39% and 58% for 2.3- and 5.1-μm particle aerosols, respectively, whereas the deposition in the deep lung was 12% and 8%, respectively. This information will be useful in developing animal models for inhaled infectious agents.