Hao Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hao Sun has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Barry. B. Lee
Max Planck Institute for Biophysical Chemistry, Göttingen, Germany
2 shared publications - Dingcai Cao
Sections of Surgical Research and Ophthalmology and Visual Science, Department of Surgery, University of Chicago, Chicago, IL, USA
2 shared publications - Barry B. Lee
SUNY College of Optometry, New York, NY, USA
1 shared publication Brian Arvidson
Pacific University, College of Optometry, Forest Hill, Oregon, U.S.A
1 shared publicationMitchell W. Dul
Glaucoma Institute, State University of New York, State College of Optometry, New York, New York, U.S.A
1 shared publication- William H. Swanson
School of Optometry, Indiana University, Bloomington, IN, USA
1 shared publication
Latest Publications
- Open Access
- 1 October 2010
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 10 (12) , 26
Macaque ganglion cell responses to probe stimuli on modulated backgrounds
In the natural environment, visual targets have to be detected and identified on changing backgrounds. Here, responses of parasol (magnocellular) ganglion cells to probes on modulated backgrounds are described. At low frequency, the adaptation level of the background influences the probe response, but with increasing frequency there is a strong interaction with the response to the background per se, so that on- and off-center cell responses are modulated in different phases. Interactions with the background response include both thresholding effects (when the cell's firing is suppressed and no pulse response occurs) and saturation effects (when the background response is vigorous the pulse generates few additional spikes). At 30 Hz, the effect of the pulse is largely a suppression or phase shift of the background response. The data are relevant to the probed-sinewave paradigm, in which pulse detection thresholds are modulated with pulse phase relative to a sinusoidal background. The physiological substrates of the psychophysical results with the probed-sinewave paradigm appear complex, with on- and off-center cells likely to contribute to detection at different pulse phases.
- 1 October 2010
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 10 (12) , 26
Open AccessMacaque ganglion cell responses to probe stimuli on modulated backgrounds
In the natural environment, visual targets have to be detected and identified on changing backgrounds. Here, responses of parasol (magnocellular) ganglion cells to probes on modulated backgrounds are described. At low frequency, the adaptation level of the background influences the probe response, but with increasing frequency there is a strong interaction with the response to the background per se, so that on- and off-center cell responses are modulated in different phases. Interactions with the background response include both thresholding effects (when the cell's firing is suppressed and no pulse response occurs) and saturation effects (when the background response is vigorous the pulse generates few additional spikes). At 30 Hz, the effect of the pulse is largely a suppression or phase shift of the background response. The data are relevant to the probed-sinewave paradigm, in which pulse detection thresholds are modulated with pulse phase relative to a sinusoidal background. The physiological substrates of the psychophysical results with the probed-sinewave paradigm appear complex, with on- and off-center cells likely to contribute to detection at different pulse phases.
- Open Access
- 1 September 2010
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 10 (11) , 4
Combination of rod and cone inputs in parasol ganglion cells of the magnocellular pathway
This study investigates how rod and cone inputs are combined in the magnocellular (MC) pathway in the mesopic luminance range, when both rods and cones are active. Responses of parafoveal MC ganglion cells from macaque retina were measured as a function of temporal frequency (0.62–20 Hz) or contrast (0.05–0.55) at mesopic light levels (0.2, 2, 20, and 200 td). Stimuli were of three modulation types: (1) isolated rod stimuli (only rod signals were modulated), (2) isolated cone stimuli (only cone luminance signals from long- and middle-wavelength sensitive cones were modulated), and (3) combined rod and cone stimuli (both rod and cone luminance signals were modulated in phase, as with conventional stimuli). The results showed that under mesopic conditions, the relative rod and cone inputs to the MC cells varied with light level and they are combined linearly prior to saturation. Further, rod contrast gain is relatively stable over the mesopic range while cone contrast gain increased with light level. Finally, the measured rod and cone inputs are consistent with the measured human temporal contrast sensitivity functions under comparable stimulation conditions.
- 1 September 2010
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 10 (11) , 4
Open AccessCombination of rod and cone inputs in parasol ganglion cells of the magnocellular pathway
This study investigates how rod and cone inputs are combined in the magnocellular (MC) pathway in the mesopic luminance range, when both rods and cones are active. Responses of parafoveal MC ganglion cells from macaque retina were measured as a function of temporal frequency (0.62–20 Hz) or contrast (0.05–0.55) at mesopic light levels (0.2, 2, 20, and 200 td). Stimuli were of three modulation types: (1) isolated rod stimuli (only rod signals were modulated), (2) isolated cone stimuli (only cone luminance signals from long- and middle-wavelength sensitive cones were modulated), and (3) combined rod and cone stimuli (both rod and cone luminance signals were modulated in phase, as with conventional stimuli). The results showed that under mesopic conditions, the relative rod and cone inputs to the MC cells varied with light level and they are combined linearly prior to saturation. Further, rod contrast gain is relatively stable over the mesopic range while cone contrast gain increased with light level. Finally, the measured rod and cone inputs are consistent with the measured human temporal contrast sensitivity functions under comparable stimulation conditions.
- Open Access
- 1 February 2009
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 9 (2) , 15
The chromatic input to cells of the magnocellular pathway of primates
Parasol ganglion cells of the magnocellular (MC) pathway form the physiological substrate of a luminance channel underlying photometric tasks, but they also respond weakly to red-green chromatic modulation. This may take the form of a first-harmonic (1F) response to chromatic modulation at low temporal frequencies, and/or a second-harmonic (2F) response that is more marked at higher frequencies. It is shown here that both these responses originate from a receptive field component that is intermediate in size between center and surround, i.e., a discrete, chromatic receptive field is superimposed upon an achromatic center-surround structure. Its size is similar to the receptive field (center plus surround) of midget, parvocellular cells from the same retinal eccentricity. A 2F MC cell chromatic response component is shown to be present under cone silent substitution conditions, when only the middle- (M) or long-wavelength (L) cone is modulated. This and other features suggest it is a rectified response to a chromatic signal rather than a consequence of non-linear summation of M- and L-cone signals. A scheme is presented which could give rise to such responses. It is suggested that this chromatic input to MC cells can enhance motion signals to red-green borders close to equiluminance.
- 1 February 2009
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 9 (2) , 15
Open AccessThe chromatic input to cells of the magnocellular pathway of primates
Parasol ganglion cells of the magnocellular (MC) pathway form the physiological substrate of a luminance channel underlying photometric tasks, but they also respond weakly to red-green chromatic modulation. This may take the form of a first-harmonic (1F) response to chromatic modulation at low temporal frequencies, and/or a second-harmonic (2F) response that is more marked at higher frequencies. It is shown here that both these responses originate from a receptive field component that is intermediate in size between center and surround, i.e., a discrete, chromatic receptive field is superimposed upon an achromatic center-surround structure. Its size is similar to the receptive field (center plus surround) of midget, parvocellular cells from the same retinal eccentricity. A 2F MC cell chromatic response component is shown to be present under cone silent substitution conditions, when only the middle- (M) or long-wavelength (L) cone is modulated. This and other features suggest it is a rectified response to a chromatic signal rather than a consequence of non-linear summation of M- and L-cone signals. A scheme is presented which could give rise to such responses. It is suggested that this chromatic input to MC cells can enhance motion signals to red-green borders close to equiluminance.
- 1 November 2008
- Published by Elsevier in Vision Research
- Vol. 48 (26) , 2633-2641
Assessment of contrast gain signature in inferred magnocellular and parvocellular pathways in patients with glaucoma
- 1 November 2008
- Published by Elsevier in Vision Research
- Vol. 48 (26) , 2633-2641
Assessment of contrast gain signature in inferred magnocellular and parvocellular pathways in patients with glaucoma