Claudia S. López
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Claudia S. López has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Eric Barklis
Department of Molecular Microbiology and Immunology, Oregon Health and Sciences University
3 shared publications Guillaume Thibault
Knight Cancer Institute-CEDAR, Oregan Health & Science University, Portland, OR, United States; Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, United States
3 shared publicationsJessica L. Riesterer
Oregon Health and Science University Multiscale Microscopy Core Facility Portland, OR, USA
3 shared publicationsErin S Stempinski
Multiscale Microscopy Core, Oregon Health & Science University, Portland, OR, United States
2 shared publicationsErin Stempinski
Multiscale Microscopy Core, Oregon Health & Science University (OHSU), Portland, OR
2 shared publications- Jacob D. Eccles
University of Illinois at Chicago
2 shared publications
Latest Publications
- Open Access
- 24 July 2024
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 30 (Supplement)
Training Videos as Guidance for Workshops on Cryo-EM Facilities
The Pacific Northwest cryoEM Center (PNCC) was created in 2018 by NIH the Transformative High-Resolution Cryo-electron Microscopy Program (CryoEM) to ensure access and training to high end cryo-electron microscopes [ 1]. Over the past years PNCC has created hands-on training workshops, as well as remote activities, to train novice users on different aspects of the entire cryo-EM workflow [ 2]. In order to provide the best experience to trainees coming to PNCC we created a series of videos that were made available to the community via the PNCC YouTube channel [ 3].
- 24 July 2024
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 30 (Supplement)
Open AccessTraining Videos as Guidance for Workshops on Cryo-EM Facilities
The Pacific Northwest cryoEM Center (PNCC) was created in 2018 by NIH the Transformative High-Resolution Cryo-electron Microscopy Program (CryoEM) to ensure access and training to high end cryo-electron microscopes [ 1]. Over the past years PNCC has created hands-on training workshops, as well as remote activities, to train novice users on different aspects of the entire cryo-EM workflow [ 2]. In order to provide the best experience to trainees coming to PNCC we created a series of videos that were made available to the community via the PNCC YouTube channel [ 3].
- Open Access
- 22 July 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (Supplement) , 2099
Novel Genetically Encoded Peptide Tags for Correlative Imaging: Lessons Learned
With the development of new technology and software capable of acquiring data at different scales, correlative imaging is transforming how researchers obtain molecular and spatial information from specimens. Corelative light and electron microscopy (CLEM) results can be obtained by means of imaging by light microscopy with either transmission electron (TEM) or scanning electron (SEM) [ 1-2]. Over the past few years, cellular proteins have been labeled with reporters compatible with either light microscopy or electron microscopy; however, only a few of these reporters have been utilized for CLEM experiments. An example of such reporters are those based on the oxidation of diaminobenzidine (DAB) [ 3-5] as well as the use of antibodies for the detection of specific proteins by immuno-EM techniques [ 6-7].
- 22 July 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (Supplement) , 2099
Open AccessNovel Genetically Encoded Peptide Tags for Correlative Imaging: Lessons Learned
With the development of new technology and software capable of acquiring data at different scales, correlative imaging is transforming how researchers obtain molecular and spatial information from specimens. Corelative light and electron microscopy (CLEM) results can be obtained by means of imaging by light microscopy with either transmission electron (TEM) or scanning electron (SEM) [ 1-2]. Over the past few years, cellular proteins have been labeled with reporters compatible with either light microscopy or electron microscopy; however, only a few of these reporters have been utilized for CLEM experiments. An example of such reporters are those based on the oxidation of diaminobenzidine (DAB) [ 3-5] as well as the use of antibodies for the detection of specific proteins by immuno-EM techniques [ 6-7].
- 13 July 2023
- Published by Elsevier in Current Opinion in Chemical Biology
- Vol. 76, 102369
Characteristics of genetic tags for correlative light and electron microscopy
- 13 July 2023
- Published by Elsevier in Current Opinion in Chemical Biology
- Vol. 76, 102369
Characteristics of genetic tags for correlative light and electron microscopy
- 22 July 2022
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 28 (S1) , 1370
Automatic Sample Processing for vEM in a Mouse Model of Breast Cancer
- 22 July 2022
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 28 (S1) , 1370
Automatic Sample Processing for vEM in a Mouse Model of Breast Cancer
- 23 July 2020
- Published by Oxford University Press (OUP) in Microscopy Today
- Vol. 28 (4) , 24-29
Simple Methods to Correlate Light and Scanning Electron Microscopy
Based on technologies capable of data collection between the millimeter and nanometer scales, correlative imaging has been transforming how researchers obtain molecular and spatial information from specimens. Attempts to combine multidimensional data are often met with the challenge of overcoming suboptimal sample conditions such as reduced fluorescence signal, poor specimen preservation, anisotropic specimen deformation, and low specimen contrast. These issues motivated the development and use of enhanced sample preparation procedures, as well as specialized imaging software to overcome such challenges. In this work we present three simple methods to correlate optical and scanning electron microscopy images.
- 23 July 2020
- Published by Oxford University Press (OUP) in Microscopy Today
- Vol. 28 (4) , 24-29
Simple Methods to Correlate Light and Scanning Electron Microscopy
Based on technologies capable of data collection between the millimeter and nanometer scales, correlative imaging has been transforming how researchers obtain molecular and spatial information from specimens. Attempts to combine multidimensional data are often met with the challenge of overcoming suboptimal sample conditions such as reduced fluorescence signal, poor specimen preservation, anisotropic specimen deformation, and low specimen contrast. These issues motivated the development and use of enhanced sample preparation procedures, as well as specialized imaging software to overcome such challenges. In this work we present three simple methods to correlate optical and scanning electron microscopy images.
- Open Access
Multiscale cardiac imaging to capture the whole heart and its internal cellular architecture, with applications to congenital heart disease
Efficient cardiac pumping depends on the morphological structure of the heart, but also on its sub-cellular (ultrastructural) architecture, which enables cardiac contraction. In cases of congenital heart defects, localized sub-cellular disruptions in architecture that increase the risk of heart failure are only starting to be discovered. This is in part due to a lack of technologies that can image the three dimensional (3D) heart structure, assessing malformations; and its ultrastructure, assessing disruptions. We present here a multiscale, correlative imaging procedure that achieves high-resolution images of the whole heart, using 3D micro-computed tomography (micro-CT); and its ultrastructure, using 3D scanning electron microscopy (SEM). This combination of technologies has not been possible before in imaging the same cardiac sample due to the heart large size, even when studying small fetal and neonatal animal models (~5×5×5mm 3 ). Here, we achieved uniform fixation and staining of the whole heart, without losing ultrastructural preservation (at the nm resolution range). Our approach enables multiscale studies of cardiac architecture in models of congenital heart disease and beyond.
Open AccessMultiscale cardiac imaging to capture the whole heart and its internal cellular architecture, with applications to congenital heart disease
Efficient cardiac pumping depends on the morphological structure of the heart, but also on its sub-cellular (ultrastructural) architecture, which enables cardiac contraction. In cases of congenital heart defects, localized sub-cellular disruptions in architecture that increase the risk of heart failure are only starting to be discovered. This is in part due to a lack of technologies that can image the three dimensional (3D) heart structure, assessing malformations; and its ultrastructure, assessing disruptions. We present here a multiscale, correlative imaging procedure that achieves high-resolution images of the whole heart, using 3D micro-computed tomography (micro-CT); and its ultrastructure, using 3D scanning electron microscopy (SEM). This combination of technologies has not been possible before in imaging the same cardiac sample due to the heart large size, even when studying small fetal and neonatal animal models (~5×5×5mm 3 ). Here, we achieved uniform fixation and staining of the whole heart, without losing ultrastructural preservation (at the nm resolution range). Our approach enables multiscale studies of cardiac architecture in models of congenital heart disease and beyond.
- 1 January 2020
- Published by Elsevier
- Vol. 158, 163-181
A workflow for visualizing human cancer biopsies using large-format electron microscopy
- 1 January 2020
- Published by Elsevier
- Vol. 158, 163-181
A workflow for visualizing human cancer biopsies using large-format electron microscopy
- 1 June 2019
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 25 (S2) , 2678-2679
Correlation Of Imaging Technologies: Methodologies.
- 1 June 2019
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 25 (S2) , 2678-2679
Correlation Of Imaging Technologies: Methodologies.
- Open Access
- 31 May 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (5) , e0176839
Quantitating morphological changes in biological samples during scanning electron microscopy sample preparation with correlative super-resolution microscopy
Sample preparation is critical to biological electron microscopy (EM), and there have been continuous efforts on optimizing the procedures to best preserve structures of interest in the sample. However, a quantitative characterization of the morphological changes associated with each step in EM sample preparation is currently lacking. Using correlative EM and superresolution microscopy (SRM), we have examined the effects of different drying methods as well as osmium tetroxide (OsO4) post-fixation on cell morphology during scanning electron microscopy (SEM) sample preparation. Here, SRM images of the sample acquired under hydrated conditions were used as a baseline for evaluating morphological changes as the sample went through SEM sample processing. We found that both chemical drying and critical point drying lead to a mild cellular boundary retraction of ~60 nm. Post-fixation by OsO4 causes at least 40 nm additional boundary retraction. We also found that coating coverslips with adhesion molecules such as fibronectin prior to cell plating helps reduce cell distortion from OsO4 post-fixation. These quantitative measurements offer useful information for identifying causes of cell distortions in SEM sample preparation and improving current procedures.
- 31 May 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (5) , e0176839
Open AccessQuantitating morphological changes in biological samples during scanning electron microscopy sample preparation with correlative super-resolution microscopy
Sample preparation is critical to biological electron microscopy (EM), and there have been continuous efforts on optimizing the procedures to best preserve structures of interest in the sample. However, a quantitative characterization of the morphological changes associated with each step in EM sample preparation is currently lacking. Using correlative EM and superresolution microscopy (SRM), we have examined the effects of different drying methods as well as osmium tetroxide (OsO4) post-fixation on cell morphology during scanning electron microscopy (SEM) sample preparation. Here, SRM images of the sample acquired under hydrated conditions were used as a baseline for evaluating morphological changes as the sample went through SEM sample processing. We found that both chemical drying and critical point drying lead to a mild cellular boundary retraction of ~60 nm. Post-fixation by OsO4 causes at least 40 nm additional boundary retraction. We also found that coating coverslips with adhesion molecules such as fibronectin prior to cell plating helps reduce cell distortion from OsO4 post-fixation. These quantitative measurements offer useful information for identifying causes of cell distortions in SEM sample preparation and improving current procedures.