CBCatharina C. Boehme

Catharina C. Boehme

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Catharina C. Boehme has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Determine TB-LAM lateral flow urine antigen assay for HIV-associated tuberculosis: recommendations on the design and reporting of clinical studies

    by Stephen D Lawn, Keertan Dheda, Andrew D Kerkhoff, Jonathan G Peter, Susan Dorman, Catharina C Boehme, Mark P Nicol

    Detection of the Mycobacterium tuberculosis cell wall antigen lipoarabinomannan (LAM) in urine permits diagnoses of tuberculosis (TB) to be made in HIV-infected patients with advanced immunodeficiency. This can be achieved at the point-of-care within just 30 minutes using the Determine TB-LAM, which is a commercially available, lateral-flow urine ‘strip test’ assay. The assay has been shown to have useful diagnostic accuracy in patients enrolling in antiretroviral treatment services or in HIV-infected patients requiring admission to hospital medical wards in sub-Saharan Africa. Such patients have high mortality risk and have most to gain from rapid diagnosis of TB and immediate initiation of treatment. However, few studies using this assay have yet been reported and many questions remain concerning the correct use of the assay, interpretation of results, the role of the assay as an add-on test within existing diagnostic algorithms and the types of further studies needed. In this paper we address a series of questions with the aim of informing the design, conduct and interpretation of future studies. Specifically, we clarify which clinical populations are most likely to derive benefit from use of this assay and how patients enrolled in such studies might best be characterised. We describe the importance of employing a rigorous microbiological diagnostic reference standard in studies of diagnostic accuracy and discuss issues surrounding the specificity of the assay in different geographical areas and potential cross-reactivity with non-tuberculous mycobacteria and other organisms. We highlight the importance of careful procedures for urine collection and storage and the critical issue of how to read and interpret the test strips. Finally, we consider how the assay could be used in combination with other assays and outline the types of studies that are required to build the evidence base concerning its use.


  • Open Access

    Transforming TB Diagnosis: Can Patients and Control Programs Afford to Wait?

    by Elizabeth A. Talbot, Jean W. Pape, Lakshmi Sundaram, Catharina C. Boehme, Mark D. Perkins


  • Xpert MTB/RIF test for tuberculosis – Authors' reply

    by Mark D Perkins, David Alland, Mark P Nicol, Pamela Nabeta, Catharina C Boehme


  • Top Cited Papers
    Open Access

    Feasibility, diagnostic accuracy, and effectiveness of decentralised use of the Xpert MTB/RIF test for diagnosis of tuberculosis and multidrug resistance: a multicentre implementation study

    by Catharina C Boehme, Mark P Nicol, Pamela Nabeta, Joy S Michael, Eduardo Gotuzzo, Rasim Tahirli, Ma Tarcela Gler, Robert Blakemore, William Worodria, Christen Gray, et al.


  • Top Cited Papers

    Rapid Molecular Detection of Tuberculosis and Rifampin Resistance

    by Catharina C. Boehme, Pamela Nabeta, Doris Hillemann, Mark P. Nicol, Shubhada Shenai, Fiorella Krapp, Jenny Allen, Rasim Tahirli, Robert Blakemore, Roxana Rustomjee, et al.

    Global control of tuberculosis is hampered by slow, insensitive diagnostic methods, particularly for the detection of drug-resistant forms and in patients with human immunodeficiency virus infection. Early detection is essential to reduce the death rate and interrupt transmission, but the complexity and infrastructure needs of sensitive methods limit their accessibility and effect. We assessed the performance of Xpert MTB/RIF, an automated molecular test for Mycobacterium tuberculosis (MTB) and resistance to rifampin (RIF), with fully integrated sample processing in 1730 patients with suspected drug-sensitive or multidrug-resistant pulmonary tuberculosis. Eligible patients in Peru, Azerbaijan, South Africa, and India provided three sputum specimens each. Two specimens were processed with N-acetyl-L-cysteine and sodium hydroxide before microscopy, solid and liquid culture, and the MTB/RIF test, and one specimen was used for direct testing with microscopy and the MTB/RIF test. Among culture-positive patients, a single, direct MTB/RIF test identified 551 of 561 patients with smear-positive tuberculosis (98.2%) and 124 of 171 with smear-negative tuberculosis (72.5%). The test was specific in 604 of 609 patients without tuberculosis (99.2%). Among patients with smear-negative, culture-positive tuberculosis, the addition of a second MTB/RIF test increased sensitivity by 12.6 percentage points and a third by 5.1 percentage points, to a total of 90.2%. As compared with phenotypic drug-susceptibility testing, MTB/RIF testing correctly identified 200 of 205 patients (97.6%) with rifampin-resistant bacteria and 504 of 514 (98.1%) with rifampin-sensitive bacteria. Sequencing resolved all but two cases in favor of the MTB/RIF assay. The MTB/RIF test provided sensitive detection of tuberculosis and rifampin resistance directly from untreated sputum in less than 2 hours with minimal hands-on time. (Funded by the Foundation for Innovative New Diagnostics.)


  • Operational Feasibility of Using Loop-Mediated Isothermal Amplification for Diagnosis of Pulmonary Tuberculosis in Microscopy Centers of Developing Countries

    by Catharina C. Boehme, Pamela Nabeta, German Henostroza, Rubhana Raqib, Zeaur Rahim, Martina Gerhardt, Erica Sanga, Michael Hoelscher, Tsugunori Notomi, Tetsu Hase, et al.

    The characteristics of loop-mediated isothermal amplification (LAMP) make it a promising platform for the molecular detection of tuberculosis (TB) in developing countries. Here, we report on the first clinical evaluation of LAMP for the detection of pulmonary TB in microscopy centers in Peru, Bangladesh, and Tanzania to determine its operational applicability in such settings. A prototype LAMP assay with simplified manual DNA extraction was evaluated for accuracy and ease of use. The sensitivity of LAMP in smear- and culture-positive sputum specimens was 97.7% (173/177 specimens; 95% confidence interval [CI], 95.5 to 99.9%), and the sensitivity in smear-negative, culture-positive specimens was 48.8% (21/43 specimens; CI, 33.9 to 63.7%). The specificity in culture-negative samples was 99% (500/505 specimens; CI, 98.1 to 99.9%). The average hands-on time for testing six samples and two controls was 54 min, similar to that of sputum smear microscopy. The optimal amplification time was 40 min. No indeterminate results were reported, and the interreader variability was 0.4%. Despite the use of a single room without biosafety cabinets for all procedures, no DNA contamination was observed. The assay was robust, with high end-point stability and low rates of test failure. Technicians with no prior molecular experience easily performed the assay after 1 week of training, and opportunities for further simplification of the assay were identified.