TTTodd Thorsen

Todd Thorsen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Todd Thorsen has a total of 39 co-authors. Here are the top co-authors by number of shared publications:

  • Manuel Marquez

    NIST Center for Theoretical and Computational Nanosciences 2 , Gaithersburg, Maryland 20899, USA

    5 shared publications
  • Min-Cheol Kim

    Massachusetts Institute of Technology

    5 shared publications
  • Raymond H. W. Lam

    Department of Biomedical Engineering, College of Biomedicine, City University of Hong Kong, Hong Kong 999077, China

    5 shared publications
  • Yasmin Srivastava

    Massachusetts Institute of Technology 1 Department of Mechanical Engineering Cambridge, Massachusetts 02139-4307, USA

    4 shared publications
  • John Paul Urbanski

    Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA

    3 shared publications
  • Chien-Chih Huang

    Institute for Soldier Nanotechnologies, Massachusetts Institute of Technology, Cambridge, MA 02139, USA

    2 shared publications

Latest Publications

  • High-throughput dental biofilm growth analysis for multiparametric microenvironmental biochemical conditions using microfluidics

    by Raymond H. W. Lam, Xin Cui, Weijin Guo, Todd Thorsen

    Dental biofilm formation is not only a precursor to tooth decay, but also induces more serious systematic health problems such as cardiovascular disease and diabetes. Understanding the conditions promoting colonization and subsequent biofilm development involving complex bacteria coaggregation is particularly important. In this paper, we report a high-throughput microfluidic ‘artificial teeth’ device offering controls of multiple microenvironmental factors (e.g. nutrients, growth factors, dissolved gases, and seeded cell populations) for quantitative characteristics of long-term dental bacteria growth and biofilm development. This ‘artificial teeth’ device contains multiple (up to 128) incubation chambers to perform parallel cultivation and analyses (e.g. biofilm thickness, viable-dead cell ratio, and spatial distribution of multiple bacterial species) of bacteria samples under a matrix of different combinations of microenvironmental factors, further revealing possible developmental mechanisms of dental biofilms. Specifically, we applied the ‘artificial teeth’ to investigate the growth of two key dental bacteria, Streptococci species and Fusobacterium nucleatum, in the biofilm under different dissolved gas conditions and sucrose concentrations. Together, this high-throughput microfluidic platform can provide extended applications for general biofilm research, including screening of the biofilm properties developing under combinations of specified growth parameters such as seeding bacteria populations, growth medium compositions, medium flow rates and dissolved gas levels.


  • Open Access

    Ultrafast high-pressure AC electro-osmotic pumps for portable biomedical microfluidics

    by Chien-Chih Huang, Martin Z. Bazant, Todd Thorsen

    This paper details the development of an integrated AC electro-osmotic (ACEO) microfluidic pump for dilute electrolytes consisting of a long serpentine microchannel lined with three dimensional (3D) stepped electrode arrays. Using low AC voltage (1 V rms, 1 kHz), power (5 mW) and current (4.5 mA) in water, the pump is capable of generating a 1.3 kPa head pressure, a 100-fold increase over prior ACEO pumps, and a 1.3 mm/s effective slip velocity over the electrodes without flow reversal. The integrated ACEO pump can utilize low ionic strength solutions such as distilled water as the working solution to pump physiological strength (100 mM) biological solutions in separate microfluidic devices, with potential applications in portable or implantable biomedical microfluidic devices. As a proof-of-concept experiment, the use of the ACEO pumps for DNA hybridization in a microfluidic microarray is demonstrated.


  • Open Access

    Ultrafast High-pressure AC Electro-osmotic Pumps for Portable Biomedical Microfluidics

    by Chien-Chih Huang, Martin Z. Bazant, Todd Thorsen

    This paper details the development of an integrated AC electro-osmotic (ACEO) microfluidic pump for dilute electrolytes consisting of a long serpentine microchannel lined with three dimensional (3D) stepped electrode arrays. Using low AC voltage (1 Volt rms, 1 kHz), power (5 mW) and current (3.5 mA) in water, the pump is capable of generating a 1.4 kPa head pressure, a 100-fold increase over prior ACEO pumps, and a 1.37 mm/sec effective slip velocity over the electrodes without flow reversal. The integrated ACEO pump can utilize low ionic strength solutions such as distilled water as the working solution to pump physiological strength (100 mM) biological solutions in separate microfluidic devices, with potential applications in portable or implantable biomedical microfluidic devices. As a proof-of-concept experiment, the use of the ACEO pumps for DNA hybridization in a microfluidic microarray is demonstrated.

  • Open Access

    Culturing Aerobic and Anaerobic Bacteria and Mammalian Cells with a Microfluidic Differential Oxygenator

    by Raymond H. W. Lam, Min-Cheol Kim, Todd Thorsen

    In this manuscript, we report on the culture of anaerobic and aerobic species within a disposable multilayer polydimethylsiloxane (PDMS) microfluidic device with an integrated differential oxygenator. A gas-filled microchannel network functioning as an oxygen−nitrogen mixer generates differential oxygen concentration. By controlling the relative flow rate of the oxygen and nitrogen input gases, the dissolved oxygen (DO) concentration in proximal microchannels filled with culture media are precisely regulated by molecular diffusion. Sensors consisting of an oxygen-sensitive dye embedded in the fluid channels permit dynamic fluorescence-based monitoring of the DO concentration using low-cost light-emitting diodes. To demonstrate the general utility of the platform for both aerobic and anaerobic culture, three bacteria with differential oxygen requirements (E. coli, A. viscosus, and F. nucleatum), as well as a model mammalian cell line (murine embryonic fibroblast cells (3T3)), were cultured. Growth characteristics of the selected species were analyzed as a function of eight discrete DO concentrations, ranging from 0 ppm (anaerobic) to 42 ppm (fully saturated).


  • Microfluidic electrospinning of biphasic nanofibers with Janus morphology

    by Yasmin Srivastava, Manuel Marquez, Todd Thorsen

    In this paper a method of electrospinning conducting and nonconducting biphasic Janus nanofibers using microfluidic polydimethylsiloxane (PDMS)-based manifolds is described. Key benefits of using microfluidic devices for nanofiber synthesis include rapid prototyping, ease of fabrication, and the ability to spin multiple Janus fibers in parallel through arrays of individual microchannels. Biphasic Janus nanofibers of polyvinylpyrrolidone (PVP)+polypyrrole (PPy)/PVP nanofibers with an average diameter of 250nm were successfully fabricated using elastomeric microfluidic devices. Fiber characterization and confirmation of the Janus morphology was subsequently carried out using a combination of scanning electron microscopy, energy dispersion spectroscopy, and transmission electron microscopy.


  • Noninvasive Metabolic Profiling Using Microfluidics for Analysis of Single Preimplantation Embryos

    by John Paul Urbanski, Mark T. Johnson, David D. Craig, David L. Potter, David K. Gardner, Todd Thorsen

    Noninvasive analysis of metabolism at the single cell level will have many applications in evaluating cellular physiology. One clinically relevant application would be to determine the metabolic activities of embryos produced through assisted reproduction. There is increasing evidence that embryos with greater developmental capacity have distinct metabolic profiles. One of the standard techniques for evaluating embryonic metabolism has been to evaluate consumption and production of several key energetic substrates (glucose, pyruvate, and lactate) using microfluorometric enzymatic assays. These assays are performed manually using constriction pipets, which greatly limits the utility of this system. Through multilayer soft-lithography, we have designed a microfluidic device that can perform these assays in an automated fashion. Following manual loading of samples and enzyme cocktail reagents, this system performs sample and enzyme cocktail aliquotting, mixing of reagents, data acquisition, and data analysis without operator intervention. Optimization of design and operating regimens has resulted in the ability to perform serial measurements of glucose, pyruvate, and lactate in triplicate with submicroliter sample volumes within 5 min. The current architecture allows for automated analysis of 10 samples and intermittent calibration over a 3 h period. Standard curves generated for each metabolite have correlation coefficients that routinely exceed 0.99. With the use of a standard epifluorescent microscope and CCD camera, linearity is obtained with metabolite concentrations in the low micromolar range (low femtomoles of total analyte). This system is inherently flexible, being easily adapted for any NAD(P)H-based assay and scaled up in terms of sample ports. Open source JAVA-based software allows for simple alterations in routine algorithms. Furthermore, this device can be used as a standalone device in which media samples are loaded or be integrated into microfluidic culture systems for in line, real time metabolic evaluation. With the improved throughput and flexibility of this system, many barriers to evaluating metabolism of embryos and single cells are eliminated. As a proof of principle, metabolic activities of single murine embryos were evaluated using this device.


  • Electrospinning hollow and core/sheath nanofibers using hydrodynamic fluid focusing

    by Yasmin Srivastava, Christopher Rhodes, Manuel Marquez, Todd Thorsen


  • Building a better cell trap: Applying Lagrangian modeling to the design of microfluidic devices for cell biology

    by Min-Cheol Kim, Zhanhui Wang, Raymond H. W. Lam, Todd Thorsen

    In this report, we show how computational fluid dynamics can be applied to the design of efficient hydrodynamic cell traps in microfluidic devices. Modeled hydrodynamic trap designs included a large, multiple-aperture “C-type” sieve for trapping hundreds of cells, flat single-aperture arrays for single cells, and “U-type” hydrodynamic structures with one or two apertures to confine small clusters of cells (∼10–15 cells per trap). Using 3T3 cells as a model system, the motion of each individual cell was calculated using a one-way coupled Lagrangian method. The cell was assumed to be a solid sphere, and interactions with other cells were only considered when a cell sedimented in the trap. The ordinary differential equations were solved along the cell trajectory for the three components of the velocity and location vector by using the Rosenbrock method based on an adaptive time-stepping technique. Validation of the predictive value of modeling, using 3T3 cells flowed through microfluidic devices containing “U-type sieves” under the simulation flow parameters, showed excellent agreement between experiment and simulation with respect to cell number per trap and the uniformity of cell distribution within individual microchambers. For applications such as on-chip cell culture or high-throughput screening of cell populations within a lab-on-a-chip environment, Lagrangian simulations have the potential to greatly simplify the design process.


  • Multijet electrospinning of conducting nanofibers from microfluidic manifolds

    by Yasmin Srivastava, Manuel Marquez, Todd Thorsen

    We present a method for the electrospinning of conducting polymeric composite nanofibers using a poly(dimethyl siloxane) (PDMS)‐based microfluidic device. To scale‐up the process and spin multicomponent systems, we designed a unique multi‐spinnerette electrospinning device using microchannels cast in PDMS. Nanofibers of poly (vinylpyrrolidone) and its composite with polypyrrole were successfully prepared using one‐step and two‐step microfluidic electrospinning. The effect of processing variables on the morphology of the nanofibers formed using this devicewas also studied. SEM images showed that fiber diameter and morphology strongly depend on processing parameters such as concentration, applied electric field, feed rate, solvent, and ionic salt addition. FTIR spectroscopy and conductivity measurements reveal the polymerization of pyrrole in the matrix of poly(vinyl pyrrolidone). © 2007 Wiley Periodicals, Inc. J Appl Polym Sci 2007