James L. Stephenson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
James L. Stephenson has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Scott A. McLuckey
Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN 47907-2084, USA
4 shared publications Benjamin J. Cargile
Mass Spectrometry Research Program, Research Triangle Institute, Research Triangle Park, NC, USA
3 shared publicationsAmal S. Essader
Mass Spectrometry Research Program, Research Triangle Institute, Research Triangle Park, NC, USA
2 shared publicationsJonathan L. Bundy
Biomarker and Systems Biology Research Program, Research Triangle Institute, 3040 Cornwallis Road, Research Triangle Park, North Carolina 27709-2194 and Statistics and Epidemiology Division, Research Triangle Institute, 6110 Executive Boulevard, Suite 902, Rockville, Maryland 20852-3907
2 shared publicationsAmy Y. Siu
Biomarker and Systems Biology Research Program, Research Triangle Institute, 3040 Cornwallis Road, Research Triangle Park, North Carolina 27709-2194 and Statistics and Epidemiology Division, Research Triangle Institute, 6110 Executive Boulevard, Suite 902, Rockville, Maryland 20852-3907
1 shared publicationDana L. Talley
Mass Spectrometry Program, Research Triangle Institute, Research Triangle Park, NC, USA
1 shared publication
Latest Publications
- 15 December 2008
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 81 (2) , 557-566
Comprehensive Defensin Assay for Saliva
Defensins are highly basic cationic peptides that are important components of the innate and adaptive immune response pathways. In addition, these peptides are involved in CD8+ T cell response to HIV-1, increased pulmonary infection risk among cystic fibrosis patients, upregulated levels of HNP-5 for patients with ulcerative colitis and Crohn’s disease, and monitoring HNP-3 levels as a tumor classification scheme for cutaneous T cell lymphomas, and have promise in the pharmaceutical field as a new class of antibiotics. Here we present a parallel assay for the α (HNP1−3) and β (HBD1−2) classes of defensins in saliva that are naturally observed in the concentration range of 1 ng/mL to 10 μg/mL. The method utilizes solid phase extraction of saliva samples combined with liquid chromatography-tandem mass spectrometry to identify and quantitate defensin targets. The approach involves limited sample manipulation and is easily amenable to automation. The saliva samples analyzed are derived from a large cohort study focused on examining the role of polymorphisms in genes of innate and adaptive immunity in modulating the response to vaccination for two gastrointestinal tract infections: typhoid and cholera. The α-defensin levels observed range from 1 to 10 μg/mL and correlate well with known active concentrations against a wide variety of pathogens. The observed concentration range for β-defensins was between the detection limit and 33 ng/mL and had a sensitivity level that was comparable to immunoassay-based detection. This method is easily adapted for use in a clinical immunology setting and can be modified for other biological matrixes. This assay will facilitate examination of the production, secretion, and regulation of defensin peptides in a direct fashion to coordinate levels of these compounds with gender, age, response to vaccination, gene copy number, and oral health.
- 15 December 2008
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 81 (2) , 557-566
Comprehensive Defensin Assay for Saliva
Defensins are highly basic cationic peptides that are important components of the innate and adaptive immune response pathways. In addition, these peptides are involved in CD8+ T cell response to HIV-1, increased pulmonary infection risk among cystic fibrosis patients, upregulated levels of HNP-5 for patients with ulcerative colitis and Crohn’s disease, and monitoring HNP-3 levels as a tumor classification scheme for cutaneous T cell lymphomas, and have promise in the pharmaceutical field as a new class of antibiotics. Here we present a parallel assay for the α (HNP1−3) and β (HBD1−2) classes of defensins in saliva that are naturally observed in the concentration range of 1 ng/mL to 10 μg/mL. The method utilizes solid phase extraction of saliva samples combined with liquid chromatography-tandem mass spectrometry to identify and quantitate defensin targets. The approach involves limited sample manipulation and is easily amenable to automation. The saliva samples analyzed are derived from a large cohort study focused on examining the role of polymorphisms in genes of innate and adaptive immunity in modulating the response to vaccination for two gastrointestinal tract infections: typhoid and cholera. The α-defensin levels observed range from 1 to 10 μg/mL and correlate well with known active concentrations against a wide variety of pathogens. The observed concentration range for β-defensins was between the detection limit and 33 ng/mL and had a sensitivity level that was comparable to immunoassay-based detection. This method is easily adapted for use in a clinical immunology setting and can be modified for other biological matrixes. This assay will facilitate examination of the production, secretion, and regulation of defensin peptides in a direct fashion to coordinate levels of these compounds with gender, age, response to vaccination, gene copy number, and oral health.
- Open Access
- 10 July 2008
- Published by Wiley in Electrophoresis
- Vol. 29 (13) , 2768-2778
Calculation of the isoelectric point of tryptic peptides in the pH 3.5–4.5 range based on adjacent amino acid effects
Current algorithms for the calculation of peptide or protein pI, based on the charge associated with individual amino acids, can calculate pI values to within ±0.2 pI units. Here, we present a new pI calculation algorithm that takes into account the effect of adjacent amino acids on the pI value. The algorithm accounts for the effect of adjacent amino acids ± 3 residues away from a charged aspartic or glutamic acid, as well as effects on the free C terminus, and applies a correction term to the corresponding pK values. The correction increments are derived from a 5000‐peptide training set using a genetic optimization approach. The accuracy of the new pI values obtained with this method approaches the error associated with the manufacture of the IPG strip (<±0.03 pI units). The approach is demonstrated for cytosolic cell extracts derived from the breast‐cancer cell line DU4475, and from membrane preparations from human lung‐tissue samples. One potential application of a more highly accurate pI calculation is data filtering of MS/MS outputs that will allow for more complex database searches including gene finding, and validation, and detection of coding single‐nucleotide polymorphisms in their expressed form.
- 10 July 2008
- Published by Wiley in Electrophoresis
- Vol. 29 (13) , 2768-2778
Open AccessCalculation of the isoelectric point of tryptic peptides in the pH 3.5–4.5 range based on adjacent amino acid effects
Current algorithms for the calculation of peptide or protein pI, based on the charge associated with individual amino acids, can calculate pI values to within ±0.2 pI units. Here, we present a new pI calculation algorithm that takes into account the effect of adjacent amino acids on the pI value. The algorithm accounts for the effect of adjacent amino acids ± 3 residues away from a charged aspartic or glutamic acid, as well as effects on the free C terminus, and applies a correction term to the corresponding pK values. The correction increments are derived from a 5000‐peptide training set using a genetic optimization approach. The accuracy of the new pI values obtained with this method approaches the error associated with the manufacture of the IPG strip (<±0.03 pI units). The approach is demonstrated for cytosolic cell extracts derived from the breast‐cancer cell line DU4475, and from membrane preparations from human lung‐tissue samples. One potential application of a more highly accurate pI calculation is data filtering of MS/MS outputs that will allow for more complex database searches including gene finding, and validation, and detection of coding single‐nucleotide polymorphisms in their expressed form.
- 25 January 2005
- Published by Wiley in Proteomics
- Vol. 5 (1) , 24-34
A comparison of immobilized pH gradient isoelectric focusing and strong‐cation‐exchange chromatography as a first dimension in shotgun proteomics
Recently, we have developed a high‐resolution two‐dimensional separation strategy for the analysis of complex peptide mixtures. This methodology employs isoelectric focusing of peptides on immobilized pH gradient (IPG) gels in the first dimension, followed by reversed‐phase chromatography in the second dimension, and subsequent tandem mass spectrometry analysis. The traditional approach to this mixture problem employs strong‐cation‐exchange (SCX) chromatography in the first dimension. Here, we present a direct comparison of these two first‐dimensional techniques using complex protein samples derived from the testis of Rattus norvegicus. It was found that the use of immobilized pH gradients (narrow range pH 3.5–4.5) for peptide separation in the first dimension yielded 13% more protein identifications than the optimized off‐line SCX approach (employing the entire pI range of the sample). In addition, the IPG technique allows for a much more efficient use on mass spectrometer analysis time. Separation of a tryptic digest derived from a rat testis sample on a narrow range pH gradient (over the 3.5–4.5 pH range) yielded 7626 and 2750 peptides and proteins, respectively. Peptide and protein identification was performed with high confidence using SEQUEST in combination with a data filtering program employing pI and statistical based functions to remove false‐positives from the data.
- 25 January 2005
- Published by Wiley in Proteomics
- Vol. 5 (1) , 24-34
A comparison of immobilized pH gradient isoelectric focusing and strong‐cation‐exchange chromatography as a first dimension in shotgun proteomics
Recently, we have developed a high‐resolution two‐dimensional separation strategy for the analysis of complex peptide mixtures. This methodology employs isoelectric focusing of peptides on immobilized pH gradient (IPG) gels in the first dimension, followed by reversed‐phase chromatography in the second dimension, and subsequent tandem mass spectrometry analysis. The traditional approach to this mixture problem employs strong‐cation‐exchange (SCX) chromatography in the first dimension. Here, we present a direct comparison of these two first‐dimensional techniques using complex protein samples derived from the testis of Rattus norvegicus. It was found that the use of immobilized pH gradients (narrow range pH 3.5–4.5) for peptide separation in the first dimension yielded 13% more protein identifications than the optimized off‐line SCX approach (employing the entire pI range of the sample). In addition, the IPG technique allows for a much more efficient use on mass spectrometer analysis time. Separation of a tryptic digest derived from a rat testis sample on a narrow range pH gradient (over the 3.5–4.5 pH range) yielded 7626 and 2750 peptides and proteins, respectively. Peptide and protein identification was performed with high confidence using SEQUEST in combination with a data filtering program employing pI and statistical based functions to remove false‐positives from the data.
- 1 March 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (6) , 936-945
Immobilized pH gradients as a first dimension in shotgun proteomics and analysis of the accuracy of pI predictability of peptides
In this work, we demonstrate the potential use of immobilized pH gradient isoelectric focusing as a first dimension in shotgun proteomics. The high resolving power and resulting reduction in matrix ionization effects due to analyzing peptides with almost the exact same physiochemical properties, represents a significant improvement in performance over traditional strong cation‐exchange first‐dimensional analysis associated with the shotgun proteomics approach. For example, using this technology, we were able to identify more than 6000 peptides and > 1200 proteins from the cytosolic fraction of Escherichia coli from approximately 10 μg of material analyzed in the second‐dimensional liquid chromatography‐tandem mass spectrometry experiment. Sample loads on the order of 1 mg can be resolved to 0.25 isoelectric point (pI) units, which make it possible to analyze organisms with significantly larger genomes/proteomes. Accurate pI prediction can then be employed using currently available algorithms to very effectively filter data for peptide/protein identification, and thus lowering the false‐positive rate for cross‐correlation‐based peptide identification algorithms. By simplifying the protein mixture problem to tryptic peptides, the effect of specific amino acids on pI prediction can be evaluated as a function of their position in the peptide chain.
- 1 March 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (6) , 936-945
Immobilized pH gradients as a first dimension in shotgun proteomics and analysis of the accuracy of pI predictability of peptides
In this work, we demonstrate the potential use of immobilized pH gradient isoelectric focusing as a first dimension in shotgun proteomics. The high resolving power and resulting reduction in matrix ionization effects due to analyzing peptides with almost the exact same physiochemical properties, represents a significant improvement in performance over traditional strong cation‐exchange first‐dimensional analysis associated with the shotgun proteomics approach. For example, using this technology, we were able to identify more than 6000 peptides and > 1200 proteins from the cytosolic fraction of Escherichia coli from approximately 10 μg of material analyzed in the second‐dimensional liquid chromatography‐tandem mass spectrometry experiment. Sample loads on the order of 1 mg can be resolved to 0.25 isoelectric point (pI) units, which make it possible to analyze organisms with significantly larger genomes/proteomes. Accurate pI prediction can then be employed using currently available algorithms to very effectively filter data for peptide/protein identification, and thus lowering the false‐positive rate for cross‐correlation‐based peptide identification algorithms. By simplifying the protein mixture problem to tryptic peptides, the effect of specific amino acids on pI prediction can be evaluated as a function of their position in the peptide chain.
- 8 February 2002
- Published by Elsevier in Current Opinion in Biotechnology
- Vol. 13 (1) , 57-64
Ion/ion chemistry as a top-down approach for protein analysis
- 8 February 2002
- Published by Elsevier in Current Opinion in Biotechnology
- Vol. 13 (1) , 57-64
Ion/ion chemistry as a top-down approach for protein analysis
- 1 July 1998
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 33 (7) , 664-672
Charge manipulation for improved mass determination of high‐mass species and mixture components by electrospray mass spectrometry
- 1 July 1998
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 33 (7) , 664-672
Charge manipulation for improved mass determination of high‐mass species and mixture components by electrospray mass spectrometry
- Open Access
- 1 January 1998
- Published by Wiley in Mass Spectrometry Reviews
- Vol. 17 (6) , 369-407
Ion/ion chemistry of high‐mass multiply charged ions
- 1 January 1998
- Published by Wiley in Mass Spectrometry Reviews
- Vol. 17 (6) , 369-407
Open AccessIon/ion chemistry of high‐mass multiply charged ions
- 1 February 1996
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 10 (3) , 287-298
High Explosives Vapor Detection by Glow Discharge–Ion Trap Mass Spectrometry
- 1 February 1996
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 10 (3) , 287-298
High Explosives Vapor Detection by Glow Discharge–Ion Trap Mass Spectrometry