SCSung Hwan Cho

Sung Hwan Cho

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sung Hwan Cho has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • Yu-Hwa Lo

    University of California San Diego 1 Materials Science and Engineering Program La Jolla, California 92093-0418, USA

    8 shared publications
  • Frank S. Tsai

    University of California at San Diego 2 Department of Electrical and Computer Engineering La Jolla, California 92093–0407, USA

    6 shared publications
  • Wen Qiao

    University of California San Diego 2 Department of Electrical and Computer Engineering La Jolla, California 92093-0407, USA

    4 shared publications
  • Jessica Godin

    Department of Electrical & Computer Engineering, Jacobs School of Engineering, University of California at San Diego, La Jolla, CA, USA

    3 shared publications
  • Chun H. Chen

    B Department of Bioengineering, 9500 Gilman Drive, Jacobs School of Engineering, University of California San Diego, La Jolla, CA, USA

    2 shared publications
  • Chun Hao Chen

    Department of Bioengineering, Jacobs School of Engineering, University of California at San Diego, La Jolla, CA, USA

    2 shared publications

Latest Publications

  • Review Article: Recent advancements in optofluidic flow cytometer

    by Sung Hwan Cho, Jessica M. Godin, Chun-Hao Chen, Wen Qiao, Hosuk Lee, Yu-Hwa Lo

    There is an increasing need to develop optofluidic flow cytometers. Optofluidics, where optics and microfluidics work together to create novel functionalities on a small chip, holds great promise for lab-on-a-chip flow cytometry. The development of a low-cost, compact, handheld flow cytometer and microfluorescence-activated cell sorter system could have a significant impact on the field of point-of-care diagnostics, improving health care in, for example, underserved areas of Africa and Asia, that struggle with epidemics such as HIV/AIDS. In this paper, we review recent advancements in microfluidics, on-chip optics, novel detection architectures, and integrated sorting mechanisms.


  • Lab-on-a-chip flow cytometer employing color-space-time coding

    by Sung Hwan Cho, Wen Qiao, Frank S. Tsai, Kenichi Yamashita, Yu-Hwa Lo

    We describe a fluorescent detection technique for a lab-on-a-chip flow cytometer. Fluorescent emission is encoded into a time-dependent signal as a fluorescent cell or bead traverses a waveguide array with integrated spatial filters and color filters. Different from conventional colored filters with well-defined transmission spectral window, the integrated color filters are designed to have broad transmission characteristics, similar to the red-green-blue photoreceptors in the retina of human eye. This unique design allows us to detect multiple fluorescent colors with only three color filters based on the technique of color-space-time coding using only one single photomultiplier tube or avalanche photodetector.


  • Human mammalian cell sorting using a highly integrated micro-fabricated fluorescence-activated cell sorter (μFACS)

    by Sung Hwan Cho, Chun H. Chen, Frank S. Tsai, Jessica M. Godin, Yu-Hwa Lo

    We demonstrate a high performance microfabricated FACS system with highly integrated microfluidics, optics, acoustics, and electronics. Single cell manipulation at a high speed is made possible by the fast response time (∼0.1 ms) of the integrated PZT actuator and the nozzle structure at the sorting junction. A Teflon AF-coated optofluidic waveguide along the microfluidic channel guides the illumination light, enabling multi-spot detection, while a novel space-time coding technology enhances the detection sensitivity of the μFACS system. The real-time control loop system is implemented using a field-programmable-gate-array (FPGA) for automated and accurate sorting. The μFACS achieves a high purification enrichment factor: up to ∼230 fold for both polystyrene microbeads and suspended human mammalian cells (K562) at a high throughput (>1000 cells s−1). The sorting mechanism is independent of cell properties such as size, density, and shape, thus the presented system can be applied to sort out any pure sub-populations. This new lab-on-a-chip FACS system, therefore, holds promise to revolutionize microfluidic cytometers to meet cost, size, and performance goals.


  • Mammalian Cell Sorting Using μFACS

    by Sung Hwan Cho, Chun Hao Chen, Frank S. Tsai, Jessica Godin, Yu-Hwa Lo

    K562 mammalian cells are sorted using a highly integrated microfabricated fluorescence-activated cell sorter (μFACS). The sample cells are purified with an enrichment factor of 230 at a high throughput (>1,000 cells/sec)

  • Micro-fabricated fluorescence-activated cell sorter

    by Sung Hwan Cho, Chun H. Chen, Frank S. Tsai, Yu-Hwa Lo

    We demonstrate a high sensitivity, high throughput microfabricated cell sorting device with the integrated piezoelectric actuator and optofluidic waveguide on a chip. For automated sorting, field-programmable-gate-array (FPGA) embedded real time control loop system is built. The sorting is performed under high flow rate (~10 cm/sec), and the sorting system can achieve a high throughput (> 1 kHz) with high purity. Moreover, to enhance its sensitivity, Teflon AF coated liquid core waveguide (LCW) structure is demonstrated. Teflon AF has a lower refractive index (n=1.31) than water (n=1.33) and forms the cladding layer of the LCW. Incident light is confined and guided along the Teflon AF coated fluidic channel, and interact with samples flowing along the same channel. This enables flexible device design and gives high sensitivity to the fluorescence detection system. The preliminary results demonstrate sorting fluorescent beads at a sorting efficiency of ~70% with no false sorting.


  • Optofluidic Waveguides in Teflon AF-Coated PDMS Microfluidic Channels

    by Sung Hwan Cho, Jessica Godin, Yu-Hwa Lo

    We report a new method for fabricating an optofluidic waveguide that is compatible with polydimethylsiloxane (PDMS). The light path follows the microfluidic channels, an architecture that can maximize detection efficiency and make the most economic use of chip area in many lab-on-chip applications. The PDMS-based microfluidic channels are coated with Teflon amorphous fluoropolymers (Teflon AF) which has a lower refractive index (n = 1.31) than water (n = 1.33) to form a water/Teflon AF optical waveguide. Driven by a vacuum pump, the Teflon AF solution was flowed through the channels, leaving a thin (5-15 mum) layer of coating on the channel wall as the cladding layer of optical waveguides. This coating process resolves the limitations of spin-coating processes by reducing the elasticity mismatch between the Teflon AF cladding layer and the PDMS device body. We demonstrate that the resulting optofluidic waveguide confines and guides the laser light through the liquid core channel. Furthermore, the light in such a waveguide can be split when the fluid flow is split. This new method enables highly integrated biosensors such as lab-on-chip flow cytometers and micro-fabricated fluorescence-activated cell sorter with on-chip excitation.


  • Fabrication of aspherical polymer lenses using a tunable liquid-filled mold

    by Sung Hwan Cho, Frank S. Tsai, Wen Qiao, Nam-Hyong Kim, Yu-Hwa Lo

    We demonstrated a tunable molding process to fabricate aspherical polymer lenses that can reduce aberrations and the total length of an optical system. Radius of curvature and conic constant are shown to be the key parameters to characterize the lens profile. The good agreement between the measured profiles and the simulated profiles allows us to design and fabricate lenses of a wide range of user-specified properties. Compared to the conventional aspherical lens fabrication method using injection molding with a diamond-turned mold, the proposed method may yield savings in time and cost.


  • Fluidic Intraocular Lens With a Large Accommodation Range

    by Wen Qiao, Frank S. Tsai, Sung Hwan Cho, Huimin Yan, Yu-Hwa Lo

    Fluidic lenses with tunable focal distances were experimented in a human eye model as intraocular lenses (IOLs). Fluidic IOL shows superior performance to fixed or optic-shift accommodating IOLs because of their much wider accommodation range. Our results demonstrate that fluidic IOL can achieve an accommodation range of eight diopters, equivalent to the performance of young adults. Finite-element analysis shows that the required force for the fluidic IOL to achieve the desired amount of accommodation is comparable to the force generated from ciliary muscles of human eyes, as an initial indication that an implanted fluidic IOL may be controllable by eye muscles.


  • Microfluidic photonic integrated circuits

    by Sung Hwan Cho, Jessica Godin, Chun Hao Chen, Frank S. Tsai, Yu-Hwa Lo

    We report on the development of an inexpensive, portable lab-on-a-chip flow cytometer system in which microfluidics, photonics, and acoustics are integrated together to work synergistically. The system relies on fluid-filled twodimensional on-chip photonic components such as lenses, apertures, and slab waveguides to allow for illumination laser beam shaping, light scattering and fluorescence signal detection. Both scattered and fluorescent lights are detected by photodetectors after being collected and guided by the on-chip optics components (e.g. lenses and waveguides). The detected light signal is imported and amplified in real time and triggers the piezoelectric actuator so that the targeted samples are directed into desired reservoir for subsequent advanced analysis. The real-time, closed-loop control system is developed with field-programmable-gate-array (FPGA) implementation. The system enables high-throughput (1- 10kHz operation), high reliability and low-powered (<1mW) fluorescence activated cell sorting (FACS) on a chip. The microfabricated flow cytometer can potentially be used as a portable, inexpensive point-of-care device in resource poor environments.