Ewa Dabek-Zlotorzynska
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ewa Dabek-Zlotorzynska has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
Mahmoud M. Yassine
Analysis and Air Quality Section, Air Quality Research Division, Atmospheric Science and Technology Directorate, Science and Technology Branch, Environment Canada, Ottawa, Ontario, Canada K1A 0H3
3 shared publications- Amanda J. Wheeler
Menzies Institute for Medical Research, University of Tasmania, Hobart, TAS 7000, Australia
2 shared publications Heidi Chen
Environment Canada
2 shared publications- Jeffrey R. Brook
Air Quality Research Division, Science and Technology Branch, Environment Canada, Downsview, Ontario, Canada
2 shared publications - Lance Wallace
Independent Researcher, 428 Woodley Way, Santa Rosa, CA 95409, USA
2 shared publications Maria Piechowski
Analysis and Air Quality, Environmental Science and Technology Centre, Science and Technology Branch, Environment Canada, Ottawa, ON, Canada
2 shared publications
Latest Publications
- Open Access
- 19 August 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (8) , 1320
Assessment and Characterization of Alkylated PAHs in Selected Sites across Canada
Alkylated polycyclic aromatic hydrocarbons (alkyl-PAHs), dibenzothiophenes (DBTs), and unsubstituted polycyclic aromatic hydrocarbons (PAHs) are naturally present in fossil fuels. Thus, they can be considered as candidates for markers of pollution from petrogenic emissions such as those from traffic. Consequently, ambient air concentrations of alkyl-PAHs, DBTs, and PAHs at selected ambient air monitoring sites of various types (residential, near-road, urban-industrial, agricultural) in Montréal, Toronto, Hamilton, Edmonton, and Simcoe, were evaluated from 2015 to 2016 to study their profiles, trends, and assess potential primary emission source types. Alkyl-PAHs were the prevailing species at all sites and were most elevated at the high-traffic impacted near-road site in Toronto which was also accompanied by the highest unsubstituted PAH concentrations. Comparison of relative abundance ratios of alkyl-PAH and PAH groupings suggests that the profile differences amongst sites were small. Source attribution with cluster grouping suggested similar emission sources of alkyl-PAH and PAH at all sites, with the exception of Hamilton which was particularly impacted by additional emission sources of PAHs. The Principal Component Analysis further indicated distinct PAC profiles at HWY401 and HMT that have the same variability of “heavy PACs” but differ in “medium mass PAHs” sources. Seasonality affected the bulk species trends (alkylated naphthalenes, fluorenes, and phenanthrenes/anthracenes), especially at sites with lower concentrations of these species. This study findings confirm a notable contribution of traffic emissions to alkyl-PAH levels in urban ambient air at the studied Canadian sites, and show that enhanced speciation of alkyl-PAHs provides more data on ambient air quality and additional health risks, and can also help distinguish petrogenic-influenced sources from other sources.
- 19 August 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (8) , 1320
Open AccessAssessment and Characterization of Alkylated PAHs in Selected Sites across Canada
Alkylated polycyclic aromatic hydrocarbons (alkyl-PAHs), dibenzothiophenes (DBTs), and unsubstituted polycyclic aromatic hydrocarbons (PAHs) are naturally present in fossil fuels. Thus, they can be considered as candidates for markers of pollution from petrogenic emissions such as those from traffic. Consequently, ambient air concentrations of alkyl-PAHs, DBTs, and PAHs at selected ambient air monitoring sites of various types (residential, near-road, urban-industrial, agricultural) in Montréal, Toronto, Hamilton, Edmonton, and Simcoe, were evaluated from 2015 to 2016 to study their profiles, trends, and assess potential primary emission source types. Alkyl-PAHs were the prevailing species at all sites and were most elevated at the high-traffic impacted near-road site in Toronto which was also accompanied by the highest unsubstituted PAH concentrations. Comparison of relative abundance ratios of alkyl-PAH and PAH groupings suggests that the profile differences amongst sites were small. Source attribution with cluster grouping suggested similar emission sources of alkyl-PAH and PAH at all sites, with the exception of Hamilton which was particularly impacted by additional emission sources of PAHs. The Principal Component Analysis further indicated distinct PAC profiles at HWY401 and HMT that have the same variability of “heavy PACs” but differ in “medium mass PAHs” sources. Seasonality affected the bulk species trends (alkylated naphthalenes, fluorenes, and phenanthrenes/anthracenes), especially at sites with lower concentrations of these species. This study findings confirm a notable contribution of traffic emissions to alkyl-PAH levels in urban ambient air at the studied Canadian sites, and show that enhanced speciation of alkyl-PAHs provides more data on ambient air quality and additional health risks, and can also help distinguish petrogenic-influenced sources from other sources.
- Open Access
- 23 June 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (7) , 1012
Seasonal Aerosol Acidity, Liquid Water Content and Their Impact on Fine Urban Aerosol in SE Canada
This study explores the drivers of aerosol pH and their impact on the inorganic fraction and mass of aerosol in the S.E. Canadian urban environments of Hamilton and Toronto, Ontario. We find that inter-seasonal pH variability is mostly driven by temperature changes, which cause variations of up to one pH unit. Wintertime acidity is reduced, compared to summertime values. Because of this, the response of aerosol to precursors fundamentally changes between seasons, with a strong sensitivity of aerosol mass to levels of HNO3 in the wintertime. Liquid water content (LWC) fundamentally influences the aerosol sensitivity to NH3 and HNO3 levels. In the summertime, organic aerosol is mostly responsible for the LWC at Toronto, and ammonium sulfate for Hamilton; in the winter, LWC was mostly associated with ammonium nitrate at both sites. The combination of pH and LWC in the two sites also affects N dry deposition flux; NO3− fluxes were comparable between the two sites, but NH3 deposition flux at Toronto is almost twice what was seen in Hamilton; from November to March N deposition flux slows down leading to an accumulation of N as NO3− in the particle phase and an increase in PM2.5 levels. Given the higher aerosol pH in Toronto, aerosol masses at this site are more sensitive to the emission of HNO3 precursors compared to Hamilton. For both sites, NOx emissions should be better regulated to improve air quality during winter; this is specifically important for the Toronto site as it is thermodynamically more sensitive to the emissions of HNO3 precursors.
- 23 June 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (7) , 1012
Open AccessSeasonal Aerosol Acidity, Liquid Water Content and Their Impact on Fine Urban Aerosol in SE Canada
This study explores the drivers of aerosol pH and their impact on the inorganic fraction and mass of aerosol in the S.E. Canadian urban environments of Hamilton and Toronto, Ontario. We find that inter-seasonal pH variability is mostly driven by temperature changes, which cause variations of up to one pH unit. Wintertime acidity is reduced, compared to summertime values. Because of this, the response of aerosol to precursors fundamentally changes between seasons, with a strong sensitivity of aerosol mass to levels of HNO3 in the wintertime. Liquid water content (LWC) fundamentally influences the aerosol sensitivity to NH3 and HNO3 levels. In the summertime, organic aerosol is mostly responsible for the LWC at Toronto, and ammonium sulfate for Hamilton; in the winter, LWC was mostly associated with ammonium nitrate at both sites. The combination of pH and LWC in the two sites also affects N dry deposition flux; NO3− fluxes were comparable between the two sites, but NH3 deposition flux at Toronto is almost twice what was seen in Hamilton; from November to March N deposition flux slows down leading to an accumulation of N as NO3− in the particle phase and an increase in PM2.5 levels. Given the higher aerosol pH in Toronto, aerosol masses at this site are more sensitive to the emission of HNO3 precursors compared to Hamilton. For both sites, NOx emissions should be better regulated to improve air quality during winter; this is specifically important for the Toronto site as it is thermodynamically more sensitive to the emissions of HNO3 precursors.
- Open Access
- 16 July 2015
- Published by Springer Nature in Particle and Fibre Toxicology
- Vol. 12 (1) , 1-19
Cytotoxic and inflammatory potential of size-fractionated particulate matter collected repeatedly within a small urban area
Exposure to coarse, fine, and ultrafine particles is associated with adverse population health impacts. We investigated whether size-fractionated particles collected repeatedly in the vicinity of industrial (steel mills and associated coking operations, wastewater treatment), high traffic, and residential areas display systematic differences in biological potency. Particulate matter (PM10) samples collected at sites within Windsor, Ontario, were screened for biological potency in human A549 lung epithelial and murine J774A.1 macrophage-like cells using cytotoxicity bioassays (cellular ATP, resazurin reduction, lactate dehydrogenase (LDH) release), cytokine production, and transcript profiles. Potency was determined from the slope of each dose-effect relationship. Cytotoxic potency varied across size fractions and within a fraction across sites and sampling periods, suggesting that particle composition, in addition to size and mass, affected particle toxicity. While ATP and LDH profiles showed some similarity, resazurin reduction (a measure of metabolic activity) exhibited a unique pattern of response, indicating that the cytotoxicity assays were sensitive to distinct particle characteristics. Chemical speciation varied in relation to prevailing winds, consistent with enrichment of source emissions (e.g. higher metal and polycyclic aromatic hydrocarbon content downwind of the industrial site). Notwithstanding this variability, site-dependent differences in particle toxicity were evident, including greater potency of coarse fractions at the industrial site and of ultrafine particles at the traffic site (Site × Size interactions, p < 0.05). Regression of potency against particle constituents revealed correlations between resazurin reduction, induction of metal-responsive genes, and metal content, which were particularly strong for the coarse fraction, and between cytokine release and endotoxin, suggesting that these factors were important drivers of biological effects that explain, at least in part, the contrasting potencies of particles compared on an equivalent mass basis. The data show that 1) particle potency and composition can exhibit significant temporal variation in relation to source contributions; 2) sources may differentially impact the potency of specific size fractions; and 3) particle constituents, notably metals and endotoxin, may elicit distinct biological responses. Together, the data are consistent with the notion that sources and composition, in addition to size and mass concentration, are relevant to particle toxicity.
- 16 July 2015
- Published by Springer Nature in Particle and Fibre Toxicology
- Vol. 12 (1) , 1-19
Open AccessCytotoxic and inflammatory potential of size-fractionated particulate matter collected repeatedly within a small urban area
Exposure to coarse, fine, and ultrafine particles is associated with adverse population health impacts. We investigated whether size-fractionated particles collected repeatedly in the vicinity of industrial (steel mills and associated coking operations, wastewater treatment), high traffic, and residential areas display systematic differences in biological potency. Particulate matter (PM10) samples collected at sites within Windsor, Ontario, were screened for biological potency in human A549 lung epithelial and murine J774A.1 macrophage-like cells using cytotoxicity bioassays (cellular ATP, resazurin reduction, lactate dehydrogenase (LDH) release), cytokine production, and transcript profiles. Potency was determined from the slope of each dose-effect relationship. Cytotoxic potency varied across size fractions and within a fraction across sites and sampling periods, suggesting that particle composition, in addition to size and mass, affected particle toxicity. While ATP and LDH profiles showed some similarity, resazurin reduction (a measure of metabolic activity) exhibited a unique pattern of response, indicating that the cytotoxicity assays were sensitive to distinct particle characteristics. Chemical speciation varied in relation to prevailing winds, consistent with enrichment of source emissions (e.g. higher metal and polycyclic aromatic hydrocarbon content downwind of the industrial site). Notwithstanding this variability, site-dependent differences in particle toxicity were evident, including greater potency of coarse fractions at the industrial site and of ultrafine particles at the traffic site (Site × Size interactions, p < 0.05). Regression of potency against particle constituents revealed correlations between resazurin reduction, induction of metal-responsive genes, and metal content, which were particularly strong for the coarse fraction, and between cytokine release and endotoxin, suggesting that these factors were important drivers of biological effects that explain, at least in part, the contrasting potencies of particles compared on an equivalent mass basis. The data show that 1) particle potency and composition can exhibit significant temporal variation in relation to source contributions; 2) sources may differentially impact the potency of specific size fractions; and 3) particle constituents, notably metals and endotoxin, may elicit distinct biological responses. Together, the data are consistent with the notion that sources and composition, in addition to size and mass concentration, are relevant to particle toxicity.
- Open Access
- 23 April 2013
- Published by EDP Sciences
- Vol. 1, 23003
A First Assessment of the Elemental Composition of Atmospheric Aerosols in the Canadian Oil Sands Region
Canadian Oil Sands, which comprise 97% of Canada's 176 billion barrels of proven oil reserves, are located beneath 140,200 km 2 of boreal forests, prairies and wetlands, and are the second largest known deposit of crude oil in the world. As such, this region has experienced rapid industrial development, which resulted also in increasing industrial air emissions, primarily from bitumen upgrading and mine vehicle fleet operations. This rapid development has led to concerns regarding health risk to humans, and other terrestrial and aquatic wildlife associated with exposure to toxic contaminants, especially metals and polycyclic aromatic compounds (PACs) particularly along the Athabasca River and its watershed. Canada's Minister of the Environment announced that Environment Canada (EC) will jointly lead, in collaboration with Government of Alberta and relevant stakeholders, the development and implementation of an enhanced monitoring system in the Oil Sands region to provide information on the state of the air, water, land and biodiversity. This work presents preliminary data on the first assessment of elemental composition of fine particulate matter (particles<2.5 mm in diameter; PM 2.5) at 3 air quality sites in close proximity to Oil Sands processing activities. Since December 2010, integrated 24 hour air samples were collected every sixth day on a 47-mm Teflon filters using Thermo Fisher Partisol 2000-FRM samplers operated by the National Air Pollution Surveillance (NAPS) network that involves EC and the Canadian provinces and territories. All samples including laboratory, travel and field blanks were subjected to gravimetric determination of PM 2.5 mass and energy dispersive X-ray fluorescence (ED-XRF) analysis for 46 elements. Since ED-XRF is a non-destructive technique, PM 2.5 samples were subsequently analyzed for 37 trace elements including rare earth elements using inductively-coupled plasma mass spectrometry (ICP-MS) combined with microwave-assisted acid digestion. The resulting data will be discussed.
- 23 April 2013
- Published by EDP Sciences
- Vol. 1, 23003
Open AccessA First Assessment of the Elemental Composition of Atmospheric Aerosols in the Canadian Oil Sands Region
Canadian Oil Sands, which comprise 97% of Canada's 176 billion barrels of proven oil reserves, are located beneath 140,200 km 2 of boreal forests, prairies and wetlands, and are the second largest known deposit of crude oil in the world. As such, this region has experienced rapid industrial development, which resulted also in increasing industrial air emissions, primarily from bitumen upgrading and mine vehicle fleet operations. This rapid development has led to concerns regarding health risk to humans, and other terrestrial and aquatic wildlife associated with exposure to toxic contaminants, especially metals and polycyclic aromatic compounds (PACs) particularly along the Athabasca River and its watershed. Canada's Minister of the Environment announced that Environment Canada (EC) will jointly lead, in collaboration with Government of Alberta and relevant stakeholders, the development and implementation of an enhanced monitoring system in the Oil Sands region to provide information on the state of the air, water, land and biodiversity. This work presents preliminary data on the first assessment of elemental composition of fine particulate matter (particles<2.5 mm in diameter; PM 2.5) at 3 air quality sites in close proximity to Oil Sands processing activities. Since December 2010, integrated 24 hour air samples were collected every sixth day on a 47-mm Teflon filters using Thermo Fisher Partisol 2000-FRM samplers operated by the National Air Pollution Surveillance (NAPS) network that involves EC and the Canadian provinces and territories. All samples including laboratory, travel and field blanks were subjected to gravimetric determination of PM 2.5 mass and energy dispersive X-ray fluorescence (ED-XRF) analysis for 46 elements. Since ED-XRF is a non-destructive technique, PM 2.5 samples were subsequently analyzed for 37 trace elements including rare earth elements using inductively-coupled plasma mass spectrometry (ICP-MS) combined with microwave-assisted acid digestion. The resulting data will be discussed.
- Open Access
- 23 April 2013
- Published by EDP Sciences
- Vol. 1, 14005
Concentrations of Platinum Group Elements (Pt, Pd, Rh) in Airborne Particulate Matter (PM2.5and PM10-2.5) Collected at Selected Canadian Urban Sites: a Case Study
Increasing environmental concentrations of platinum group elements (PGEs), in particular platinum (Pt), palladium (Pd) and rhodium (Rh), from catalytic converters has been reported worldwide. Initially it was believed that the emitted PGEs remain in the roadside environment, but recent studies have shown that fine PGE-containing particles can be transported and distributed at regional and long-range levels. Therefore, the monitoring of PGEs in airborne particulate matter (PM) is important for the estimation of potential risks to human health and to the ecosystem. The aim of this study is to present the first results from an analysis on the concentration and distribution of Pt, Pd and Rh in PM collected on Teflon filters at two selected urban sites (Toronto, Ontario; Edmonton, Alberta) collected within the Canadian National Air Pollution Surveillance (NAPS) network. In this work, a quadruple inductively coupled plasma mass spectrometry (ICP-MS), combined with microwave assisted acid digestion using aqua regia was used. A cation exchange separation was used to alleviate the matrix-induced spectral and nonspectral interferences prior to ICP-MS analysis. To obtain sufficient material needed for PGEs analysis, fine PM (particles with aerodynamic diameter less than 2.5 mm; PM 2.5) and coarse PM (with aerodynamic diameter between 2.5 and 10 mm; PM 10-2.5) samples were combined into composite samples on a seasonal basis. The obtained results will be discussed and compared with literature data.
- 23 April 2013
- Published by EDP Sciences
- Vol. 1, 14005
Open AccessConcentrations of Platinum Group Elements (Pt, Pd, Rh) in Airborne Particulate Matter (PM2.5and PM10-2.5) Collected at Selected Canadian Urban Sites: a Case Study
Increasing environmental concentrations of platinum group elements (PGEs), in particular platinum (Pt), palladium (Pd) and rhodium (Rh), from catalytic converters has been reported worldwide. Initially it was believed that the emitted PGEs remain in the roadside environment, but recent studies have shown that fine PGE-containing particles can be transported and distributed at regional and long-range levels. Therefore, the monitoring of PGEs in airborne particulate matter (PM) is important for the estimation of potential risks to human health and to the ecosystem. The aim of this study is to present the first results from an analysis on the concentration and distribution of Pt, Pd and Rh in PM collected on Teflon filters at two selected urban sites (Toronto, Ontario; Edmonton, Alberta) collected within the Canadian National Air Pollution Surveillance (NAPS) network. In this work, a quadruple inductively coupled plasma mass spectrometry (ICP-MS), combined with microwave assisted acid digestion using aqua regia was used. A cation exchange separation was used to alleviate the matrix-induced spectral and nonspectral interferences prior to ICP-MS analysis. To obtain sufficient material needed for PGEs analysis, fine PM (particles with aerodynamic diameter less than 2.5 mm; PM 2.5) and coarse PM (with aerodynamic diameter between 2.5 and 10 mm; PM 10-2.5) samples were combined into composite samples on a seasonal basis. The obtained results will be discussed and compared with literature data.
- Open Access
- 23 April 2013
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 1, 05005
Development of a Novel Fiber Optic Sensor Combined with a Fluorescence Turn-on Probe for Cu (II) Detection
Existing staining-based methodology for the detection of metal ions is not well suited for real-time or in situ use. This is a significant problem, given that these ions can have a considerable impact on both human health and the environment. Thus, there is growing interest and need for simple, rapid and in-situ monitoring techniques for the purpose of detecting various target analytes (e.g. heavy metals), which is of a significant importance in many fields ranging from environmental monitoring to the study of intracellular processes. Among various sensors developed, optical fiber-optic sensors (FOS), based on fluorescence, are one class of sensors that address this goal [1]. Optical fibers are ideal for environmental sensing applications because of their ability to transmit optical signals to and from the sensing region without the use of free-space optics. In this work, we present, for the first time, a simple FOS incorporating novel fluorescence turn-on mechanism [2] that could detect Cu (II) as low as 10-4 M. Traditionally, fluorescence quenching or "turn-off" was used to detect Cu (II) [3]. In recent years, fluorescence "turn-on" emerges as a preferable tool. The developed fiber-optic sensor has two fiber leads and one probe head. One fiber lead includes 6 fibers for He-Ne laser excitation light delivery (e-fibers). Another fiber lead has one receiving fiber (r-fiber) connected to an Ocean Optics QE65000 scientific grade spectrometer, which is interrogated by a computer via USB connection. The SpectroSuite software is used to observe and to record all spectra. The probe head combines all fibers together to form a coaxial structure with the r-fiber placed in the center. The key component in the proposed fluorescent sensing system is a probe prepared by binding a receptor containing a zwitterionic chromophore (M1), through noncovalent interactions, to the fluorescent polymer (P1) resulting in quenching its emission. The sensing mechanism involves the release of P1 (a fluorescent indicator) from its non-fluorescent indicator/receptor (P1/M1) pair upon exposure to Cu (II). The zwitterionic chromophore (M1) was found to show high selectivity and sensitivity to Cu (II), making it an ideal receptor for the recognition of Cu (II) [4]. The optimum operating conditions and performance characteristics for the new sensor will be discussed.
- 23 April 2013
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 1, 05005
Open AccessDevelopment of a Novel Fiber Optic Sensor Combined with a Fluorescence Turn-on Probe for Cu (II) Detection
Existing staining-based methodology for the detection of metal ions is not well suited for real-time or in situ use. This is a significant problem, given that these ions can have a considerable impact on both human health and the environment. Thus, there is growing interest and need for simple, rapid and in-situ monitoring techniques for the purpose of detecting various target analytes (e.g. heavy metals), which is of a significant importance in many fields ranging from environmental monitoring to the study of intracellular processes. Among various sensors developed, optical fiber-optic sensors (FOS), based on fluorescence, are one class of sensors that address this goal [1]. Optical fibers are ideal for environmental sensing applications because of their ability to transmit optical signals to and from the sensing region without the use of free-space optics. In this work, we present, for the first time, a simple FOS incorporating novel fluorescence turn-on mechanism [2] that could detect Cu (II) as low as 10-4 M. Traditionally, fluorescence quenching or "turn-off" was used to detect Cu (II) [3]. In recent years, fluorescence "turn-on" emerges as a preferable tool. The developed fiber-optic sensor has two fiber leads and one probe head. One fiber lead includes 6 fibers for He-Ne laser excitation light delivery (e-fibers). Another fiber lead has one receiving fiber (r-fiber) connected to an Ocean Optics QE65000 scientific grade spectrometer, which is interrogated by a computer via USB connection. The SpectroSuite software is used to observe and to record all spectra. The probe head combines all fibers together to form a coaxial structure with the r-fiber placed in the center. The key component in the proposed fluorescent sensing system is a probe prepared by binding a receptor containing a zwitterionic chromophore (M1), through noncovalent interactions, to the fluorescent polymer (P1) resulting in quenching its emission. The sensing mechanism involves the release of P1 (a fluorescent indicator) from its non-fluorescent indicator/receptor (P1/M1) pair upon exposure to Cu (II). The zwitterionic chromophore (M1) was found to show high selectivity and sensitivity to Cu (II), making it an ideal receptor for the recognition of Cu (II) [4]. The optimum operating conditions and performance characteristics for the new sensor will be discussed.
- 24 July 2012
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 84 (15) , 6586-6594
Identification of Weak and Strong Organic Acids in Atmospheric Aerosols by Capillary Electrophoresis/Mass Spectrometry and Ultra-High-Resolution Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
A novel approach using a combination of capillary electrophoresis/mass spectrometry (CE/MS) and off-line Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) revealed the structural details of acidic constituents of atmospheric organic aerosol. Both techniques utilized electrospray ionization (ESI), a soft ionization method, to facilitate the analysis of complex mixtures of organic compounds. CE/ESI-MS using an UltraTrol LN-precoated capillary and acidic background electrolytes at different pH values (2.5 and 4.7) was used to differentiate between weak (carboxylic) and strong (sulfonic) organic acids. On the basis of the electrophoretic mobility, m/z constraints from CE/ESI(−)-MS, and elemental composition information retrieved from off-line FTICR-MS, a variety of aliphatic and aromatic carboxylic acids (CHO-bearing molecules), nitrogen-containing carboxylic acids (CHON-bearing molecules), organosulfates (CHOS-bearing molecules), and (nitrooxy)organosulfates (CHONS-bearing molecules) were tentatively identified in the Oasis-HLB-extracted urban PM2.5 (particulate matter with an aerodynamic diameter of Z/M2/3). The majorities of the identified compounds are products of atmospheric reactions and are known contributors to secondary organic aerosols.
- 24 July 2012
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 84 (15) , 6586-6594
Identification of Weak and Strong Organic Acids in Atmospheric Aerosols by Capillary Electrophoresis/Mass Spectrometry and Ultra-High-Resolution Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
A novel approach using a combination of capillary electrophoresis/mass spectrometry (CE/MS) and off-line Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) revealed the structural details of acidic constituents of atmospheric organic aerosol. Both techniques utilized electrospray ionization (ESI), a soft ionization method, to facilitate the analysis of complex mixtures of organic compounds. CE/ESI-MS using an UltraTrol LN-precoated capillary and acidic background electrolytes at different pH values (2.5 and 4.7) was used to differentiate between weak (carboxylic) and strong (sulfonic) organic acids. On the basis of the electrophoretic mobility, m/z constraints from CE/ESI(−)-MS, and elemental composition information retrieved from off-line FTICR-MS, a variety of aliphatic and aromatic carboxylic acids (CHO-bearing molecules), nitrogen-containing carboxylic acids (CHON-bearing molecules), organosulfates (CHOS-bearing molecules), and (nitrooxy)organosulfates (CHONS-bearing molecules) were tentatively identified in the Oasis-HLB-extracted urban PM2.5 (particulate matter with an aerodynamic diameter of Z/M2/3). The majorities of the identified compounds are products of atmospheric reactions and are known contributors to secondary organic aerosols.
- 1 February 2011
- Vol. 61 (2) , 142-56
Windsor, Ontario exposure assessment study: design and methods validation of personal, indoor, and outdoor air pollution monitoring.
The Windsor, Ontario Exposure Assessment Study evaluated the contribution of ambient air pollutants to personal and indoor exposures of adults and asthmatic children living in Windsor, Ontario, Canada. In addition, the role of personal, indoor, and outdoor air pollution exposures upon asthmatic children's respiratory health was assessed. Several active and passive sampling methods were applied, or adapted, for personal, indoor, and outdoor residential monitoring of nitrogen dioxide, volatile organic compounds, particulate matter (PM; PM < or = 2.5 microm [PM2.5] and < or = 10 microm [PM10] in aerodynamic diameter), elemental carbon, ultrafine particles, ozone, air exchange rates, allergens in settled dust, and particulate-associated metals. Participants completed five consecutive days of monitoring during the winter and summer of 2005 and 2006. During 2006, in addition to undertaking the air pollution measurements, asthmatic children completed respiratory health measurements (including peak flow meter tests and exhaled breath condensate) and tracked respiratory symptoms in a diary. Extensive quality assurance and quality control steps were implemented, including the collocation of instruments at the National Air Pollution Surveillance site operated by Environment Canada and at the Michigan Department of Environmental Quality site in Allen Park, Detroit, MI. During field sampling, duplicate and blank samples were also completed and these data are reported. In total, 50 adults and 51 asthmatic children were recruited to participate, resulting in 922 participant days of data. When comparing the methods used in the study with standard reference methods, field blanks were low and bias was acceptable, with most methods being within 20% of reference methods. Duplicates were typically within less than 10% of each other, indicating that study results can be used with confidence. This paper covers study design, recruitment, methodology, time activity diary, surveys, and quality assurance and control results for the different methods used.
- 1 February 2011
- Vol. 61 (2) , 142-56
Windsor, Ontario exposure assessment study: design and methods validation of personal, indoor, and outdoor air pollution monitoring.
The Windsor, Ontario Exposure Assessment Study evaluated the contribution of ambient air pollutants to personal and indoor exposures of adults and asthmatic children living in Windsor, Ontario, Canada. In addition, the role of personal, indoor, and outdoor air pollution exposures upon asthmatic children's respiratory health was assessed. Several active and passive sampling methods were applied, or adapted, for personal, indoor, and outdoor residential monitoring of nitrogen dioxide, volatile organic compounds, particulate matter (PM; PM < or = 2.5 microm [PM2.5] and < or = 10 microm [PM10] in aerodynamic diameter), elemental carbon, ultrafine particles, ozone, air exchange rates, allergens in settled dust, and particulate-associated metals. Participants completed five consecutive days of monitoring during the winter and summer of 2005 and 2006. During 2006, in addition to undertaking the air pollution measurements, asthmatic children completed respiratory health measurements (including peak flow meter tests and exhaled breath condensate) and tracked respiratory symptoms in a diary. Extensive quality assurance and quality control steps were implemented, including the collocation of instruments at the National Air Pollution Surveillance site operated by Environment Canada and at the Michigan Department of Environmental Quality site in Allen Park, Detroit, MI. During field sampling, duplicate and blank samples were also completed and these data are reported. In total, 50 adults and 51 asthmatic children were recruited to participate, resulting in 922 participant days of data. When comparing the methods used in the study with standard reference methods, field blanks were low and bias was acceptable, with most methods being within 20% of reference methods. Duplicates were typically within less than 10% of each other, indicating that study results can be used with confidence. This paper covers study design, recruitment, methodology, time activity diary, surveys, and quality assurance and control results for the different methods used.
- Open Access
- 16 August 2010
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 7 (8) , 3211-3224
Exploring Variation and Predictors of Residential Fine Particulate Matter Infiltration
Although individuals spend the majority of their time indoors, most epidemiological studies estimate personal air pollution exposures based on outdoor levels. This almost certainly results in exposure misclassification as pollutant infiltration varies between homes. However, it is often not possible to collect detailed measures of infiltration for individual homes in large-scale epidemiological studies and thus there is currently a need to develop models that can be used to predict these values. To address this need, we examined infiltration of fine particulate matter (PM2.5) and identified determinants of infiltration for 46 residential homes in Toronto, Canada. Infiltration was estimated using the indoor/outdoor sulphur ratio and information on hypothesized predictors of infiltration were collected using questionnaires and publicly available databases. Multiple linear regression was used to develop the models. Mean infiltration was 0.52 ± 0.21 with no significant difference across heating and non-heating seasons. Predictors of infiltration were air exchange, presence of central air conditioning, and forced air heating. These variables accounted for 38% of the variability in infiltration. Without air exchange, the model accounted for 26% of the variability. Effective modelling of infiltration in individual homes remains difficult, although key variables such as use of central air conditioning show potential as an easily attainable indicator of infiltration.
- 16 August 2010
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 7 (8) , 3211-3224
Open AccessExploring Variation and Predictors of Residential Fine Particulate Matter Infiltration
Although individuals spend the majority of their time indoors, most epidemiological studies estimate personal air pollution exposures based on outdoor levels. This almost certainly results in exposure misclassification as pollutant infiltration varies between homes. However, it is often not possible to collect detailed measures of infiltration for individual homes in large-scale epidemiological studies and thus there is currently a need to develop models that can be used to predict these values. To address this need, we examined infiltration of fine particulate matter (PM2.5) and identified determinants of infiltration for 46 residential homes in Toronto, Canada. Infiltration was estimated using the indoor/outdoor sulphur ratio and information on hypothesized predictors of infiltration were collected using questionnaires and publicly available databases. Multiple linear regression was used to develop the models. Mean infiltration was 0.52 ± 0.21 with no significant difference across heating and non-heating seasons. Predictors of infiltration were air exchange, presence of central air conditioning, and forced air heating. These variables accounted for 38% of the variability in infiltration. Without air exchange, the model accounted for 26% of the variability. Effective modelling of infiltration in individual homes remains difficult, although key variables such as use of central air conditioning show potential as an easily attainable indicator of infiltration.
- 24 November 2009
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 2 (2) , 129-134
Determination of benzene polycarboxylic acids in atmospheric aerosols and vehicular emissions by liquid chromatography-mass spectrometry
A simple, sensitive and reliable LC-ESI(−)/MS method was developed for determination of selected aromatic dicarboxylic acids (e.g. phthalic acid isomers) and tricarboxylic acids (e.g. trimellitic, trimesic) in atmospheric aerosols and vehicular emissions without complex sample pre-treatment. Gradient liquid chromatographic separation was performed on a Zorbax SB-Aq (150 × 2.1 mm i.d., 3.5 µm) column using a mobile phase consisting of 0.1% formic acid (eluent A) and methanol (eluent B). The Zorbax SB-Aq column was chosen as it was specifically designed to retain highly polar compounds, allowing the use of highly aqueous mobile phases. The method was demonstrated to be sensitive and precise. In the SIM mode, LODs for all target acids dissolved in double deionized water were in the range of 0.03–0.1 µg/L. The method showed a good inter-day precision of retention time (RSD <0.3%) and peak area (RSD <3%). Satisfactory recoveries, ranging from 89 to 107% for the spiked blanks and extracts of real samples, were obtained. The method has been successfully applied to the quantitative analysis of selected benzene polycarboxylic acids in urban atmospheric aerosols and particulate matter emitted from diesel- and gasoline-powered motors. Preliminary results suggest that 3-hydroxyphthalic acid may be used as a potential tracer for diesel engine emissions.
- 24 November 2009
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 2 (2) , 129-134
Determination of benzene polycarboxylic acids in atmospheric aerosols and vehicular emissions by liquid chromatography-mass spectrometry
A simple, sensitive and reliable LC-ESI(−)/MS method was developed for determination of selected aromatic dicarboxylic acids (e.g. phthalic acid isomers) and tricarboxylic acids (e.g. trimellitic, trimesic) in atmospheric aerosols and vehicular emissions without complex sample pre-treatment. Gradient liquid chromatographic separation was performed on a Zorbax SB-Aq (150 × 2.1 mm i.d., 3.5 µm) column using a mobile phase consisting of 0.1% formic acid (eluent A) and methanol (eluent B). The Zorbax SB-Aq column was chosen as it was specifically designed to retain highly polar compounds, allowing the use of highly aqueous mobile phases. The method was demonstrated to be sensitive and precise. In the SIM mode, LODs for all target acids dissolved in double deionized water were in the range of 0.03–0.1 µg/L. The method showed a good inter-day precision of retention time (RSD <0.3%) and peak area (RSD <3%). Satisfactory recoveries, ranging from 89 to 107% for the spiked blanks and extracts of real samples, were obtained. The method has been successfully applied to the quantitative analysis of selected benzene polycarboxylic acids in urban atmospheric aerosols and particulate matter emitted from diesel- and gasoline-powered motors. Preliminary results suggest that 3-hydroxyphthalic acid may be used as a potential tracer for diesel engine emissions.