Kemp Howard Kernstine
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kemp Howard Kernstine has a total of 283 co-authors. Here are the top co-authors by number of shared publications:
- Javier H. Campos
Perioperative Services, Department of Anesthesia, University of Iowa Carver College of Medicine, Iowa City, IA
3 shared publications Casandra A. Anderson
Department of Thoracic Surgery, City of Hope National Medical Center, Duarte, CA USA
2 shared publicationsDaniel T. DeArmond
2 shared publications- Kun Ge
Hebei University College of Life Sciences, Baoding 071002, China
2 shared publications - Li Zhong
Lung Cancer and Thoracic Oncology Program, City of Hope and Beckman Research Institute, 1500 Duarte Road, Duarte, CA 91010, USA
2 shared publications - Timothy L. Van Natta
Department of Surgery, Division of Cardiothoracic Surgery, Harbor-UCLA Medical Center, Box 423, 1000 W Carson St, Torrance, CA 90509, USA
2 shared publications
Latest Publications
- Open Access
- 1 January 2010
- Published by Springer Nature in BMC Biotechnology
- Vol. 10 (1) , 12
Protein microarray: sensitive and effective immunodetection for drug residues
Veterinary drugs such as clenbuterol (CL) and sulfamethazine (SM2) are low molecular weight (<1000 Da) compounds, or haptens, that are difficult to develop immunoassays due to their low immunogenicity. In this study, we conjugated the drugs to ovalbumin to increase their immunogenicity for antiserum production in rabbits and developed a protein microarray immunoassay for detection of clenbuterol and sulfamethazine. The sensitivity of this approach was then compared to traditional ELISA technique.
- 1 January 2010
- Published by Springer Nature in BMC Biotechnology
- Vol. 10 (1) , 12
Open AccessProtein microarray: sensitive and effective immunodetection for drug residues
Veterinary drugs such as clenbuterol (CL) and sulfamethazine (SM2) are low molecular weight (<1000 Da) compounds, or haptens, that are difficult to develop immunoassays due to their low immunogenicity. In this study, we conjugated the drugs to ovalbumin to increase their immunogenicity for antiserum production in rabbits and developed a protein microarray immunoassay for detection of clenbuterol and sulfamethazine. The sensitivity of this approach was then compared to traditional ELISA technique.
- 1 January 2010
- Published by Elsevier
Contributors
- Open Access
- 1 October 2009
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 4 (6) , 354-357
Robotic Fourth-Arm Enucleation of an Esophageal Leiomyoma and Review of Literature
Esophageal leiomyomas are resected in symptomatic and/or malignancy-suspicious cases. Traditionally, they have been removed by laparotomy or thoracotomy and more recently by thoracoscopy and laparoscopy. Mucosal injury is reported as high as 7% of cases but may be higher in unreported general practice. Robotic technology seems to offer advantages. We describe a robotic approach that seems to minimize mobilization of the esophagus, potentially decreasing the likelihood of mucosal injury and postoperative recovery time. We review the literature to evaluate the reports of mucosal injury with the open, minimally invasive, and robotic techniques and describe our own method. To improve efficiency, we use a four-arm technique.
- 1 October 2009
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 4 (6) , 354-357
Open AccessRobotic Fourth-Arm Enucleation of an Esophageal Leiomyoma and Review of Literature
Esophageal leiomyomas are resected in symptomatic and/or malignancy-suspicious cases. Traditionally, they have been removed by laparotomy or thoracotomy and more recently by thoracoscopy and laparoscopy. Mucosal injury is reported as high as 7% of cases but may be higher in unreported general practice. Robotic technology seems to offer advantages. We describe a robotic approach that seems to minimize mobilization of the esophagus, potentially decreasing the likelihood of mucosal injury and postoperative recovery time. We review the literature to evaluate the reports of mucosal injury with the open, minimally invasive, and robotic techniques and describe our own method. To improve efficiency, we use a four-arm technique.
- Open Access
- 1 October 2009
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 4 (6) , 297-298
Minimally Invasive Ivor-Lewis Esophagectomy
- 1 October 2009
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 4 (6) , 297-298
Open AccessMinimally Invasive Ivor-Lewis Esophagectomy
- 1 March 2009
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 87 (3) , 891-892
Invited Commentary
- 1 March 2009
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 87 (3) , 891-892
Invited Commentary
- 18 May 2008
- Published by Springer Nature in Surgical Endoscopy
- Vol. 22 (9) , 2102
The first series of completely robotic esophagectomies with three-field lymphadenectomy: initial experience
- 18 May 2008
- Published by Springer Nature in Surgical Endoscopy
- Vol. 22 (9) , 2102
The first series of completely robotic esophagectomies with three-field lymphadenectomy: initial experience
- Open Access
- 7 May 2008
- Published by Springer Nature in Breast Cancer Research
- Vol. 10 (3) , R40
Autoantibodies as potential biomarkers for breast cancer
Introduction: Only a limited number of tumor markers for breast cancer are currently available. Antibodies to tumor-associated proteins may expand the number of available tumor markers for breast cancer and may be used together in a serum profile to enhance sensitivity and specificity. Methods: In the present study, we interrogated a breast cancer cDNA T7 phage library for tumor-associated proteins using biopan enrichment techniques with sera from normal individuals and from breast cancer patients. The enrichment of tumor-associated proteins after biopanning was tested using a plaque-lift assay and immunochemical detection. The putative tumor-associated phage clones were collected for PCR and sequencing analysis. Unique and open reading frame phage-expressed proteins were then used to develop phage protein ELISAs to measure corresponding autoantibodies using 87 breast cancer patients and 87 normal serum samples. A logistic regression model and leave-one-out validation were used to evaluate predictive accuracies with a single marker as well as with combined markers. Identities of those selected proteins were revealed through the sequence BLAST program. Results: We harvested 100 putative tumor-associated phage clones after biopan enrichment. Sequencing analysis revealed that six phage proteins were inframe and unique. Antibodies to these six phage-expressed proteins were measured by ELISAs, and the results showed that three of the phage clones had statistical significance in discriminating patients from normal individuals. BLAST results of the three proteins showed great matches to ASB-9, SERAC1, and RELT. Measurements of the three predictive phage proteins were combined in a logistic regression model that achieved 80% sensitivity and 100% specificity in prediction of sample status, whereas leave-one-out validation achieved 77.0% sensitivity and 82.8% specificity among 87 patient samples and 87 control samples. Receiver operating characteristic curve analysis and the leave-one-out method both showed that combined measurements of the three antibodies were more predictive of disease than any of the single antibodies studied, underscoring the importance of identifying multiple potential markers. Conclusion: Serum autoantibody profiling is a promising approach for early detection and diagnosis of breast cancer. Rather than one autoantibody, a panel of autoantibodies appears preferable to achieve superior accuracy. Further refinements will need to be made to further improve the accuracy. Once refined, the assay must be applied to a prospective patient population to demonstrate applicability.
- 7 May 2008
- Published by Springer Nature in Breast Cancer Research
- Vol. 10 (3) , R40
Open AccessAutoantibodies as potential biomarkers for breast cancer
Introduction: Only a limited number of tumor markers for breast cancer are currently available. Antibodies to tumor-associated proteins may expand the number of available tumor markers for breast cancer and may be used together in a serum profile to enhance sensitivity and specificity. Methods: In the present study, we interrogated a breast cancer cDNA T7 phage library for tumor-associated proteins using biopan enrichment techniques with sera from normal individuals and from breast cancer patients. The enrichment of tumor-associated proteins after biopanning was tested using a plaque-lift assay and immunochemical detection. The putative tumor-associated phage clones were collected for PCR and sequencing analysis. Unique and open reading frame phage-expressed proteins were then used to develop phage protein ELISAs to measure corresponding autoantibodies using 87 breast cancer patients and 87 normal serum samples. A logistic regression model and leave-one-out validation were used to evaluate predictive accuracies with a single marker as well as with combined markers. Identities of those selected proteins were revealed through the sequence BLAST program. Results: We harvested 100 putative tumor-associated phage clones after biopan enrichment. Sequencing analysis revealed that six phage proteins were inframe and unique. Antibodies to these six phage-expressed proteins were measured by ELISAs, and the results showed that three of the phage clones had statistical significance in discriminating patients from normal individuals. BLAST results of the three proteins showed great matches to ASB-9, SERAC1, and RELT. Measurements of the three predictive phage proteins were combined in a logistic regression model that achieved 80% sensitivity and 100% specificity in prediction of sample status, whereas leave-one-out validation achieved 77.0% sensitivity and 82.8% specificity among 87 patient samples and 87 control samples. Receiver operating characteristic curve analysis and the leave-one-out method both showed that combined measurements of the three antibodies were more predictive of disease than any of the single antibodies studied, underscoring the importance of identifying multiple potential markers. Conclusion: Serum autoantibody profiling is a promising approach for early detection and diagnosis of breast cancer. Rather than one autoantibody, a panel of autoantibodies appears preferable to achieve superior accuracy. Further refinements will need to be made to further improve the accuracy. Once refined, the assay must be applied to a prospective patient population to demonstrate applicability.
- 30 September 2007
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 84 (3) , 971-972
Invited commentary
- 30 September 2007
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 84 (3) , 971-972
Invited commentary
- Open Access
- 1 September 2007
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 2 (5) , 254-258
Robotic-Assisted Lung Resection for Malignant Disease
There have been few reports of the use of robotic surgery to resect lung malignancies. Feasibility and safety of robotic lung resection for malignant lung lesions will be assessed by performing a retrospective analysis. Between September 2004 and November 2006, 21 patients (11 male and 10 female patients) underwent robotic lung resection. Twenty resections were performed for primary nonsmall cell lung cancer and two for metastatic lesions. One patient had bilateral resections for two primary tumors. Fourteen lobectomies, five segementectomies, one wedge resection, and two bilobectomies were performed. Seventy-two percent of operative procedures included mediastinoscopy and/or bronchoscopy at the time of resection. Thirty-day mortality and conversion rate was 0%. The median operating room time and estimated blood loss was 3.6 hours and 100 mL, respectively. The median intensive care unit and total length of hospital stays were 2 and 4 days, respectively. Chest tubes were removed after a median of 2.0 days. The complication rate was 27%, which included atrial fibrillation, need for postoperative bronchoscopy, and pneumonia. The median tumor size and number of lymph nodes harvested was 2.3 cm and 16, respectively. All resection margins were negative. Median follow-up time was 9.8 months, with no local recurrences at this time. Robotic lung resection appears safe and feasible and allows for significant lymph node retrieval, offers short hospital stays and low morbidity for patients undergoing surgical resection of lung malignancies. Future studies are needed to define the role of robotic surgery in lung cancer treatment.
- 1 September 2007
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 2 (5) , 254-258
Open AccessRobotic-Assisted Lung Resection for Malignant Disease
There have been few reports of the use of robotic surgery to resect lung malignancies. Feasibility and safety of robotic lung resection for malignant lung lesions will be assessed by performing a retrospective analysis. Between September 2004 and November 2006, 21 patients (11 male and 10 female patients) underwent robotic lung resection. Twenty resections were performed for primary nonsmall cell lung cancer and two for metastatic lesions. One patient had bilateral resections for two primary tumors. Fourteen lobectomies, five segementectomies, one wedge resection, and two bilobectomies were performed. Seventy-two percent of operative procedures included mediastinoscopy and/or bronchoscopy at the time of resection. Thirty-day mortality and conversion rate was 0%. The median operating room time and estimated blood loss was 3.6 hours and 100 mL, respectively. The median intensive care unit and total length of hospital stays were 2 and 4 days, respectively. Chest tubes were removed after a median of 2.0 days. The complication rate was 27%, which included atrial fibrillation, need for postoperative bronchoscopy, and pneumonia. The median tumor size and number of lymph nodes harvested was 2.3 cm and 16, respectively. All resection margins were negative. Median follow-up time was 9.8 months, with no local recurrences at this time. Robotic lung resection appears safe and feasible and allows for significant lymph node retrieval, offers short hospital stays and low morbidity for patients undergoing surgical resection of lung malignancies. Future studies are needed to define the role of robotic surgery in lung cancer treatment.