SAShai Ashkenazi

Shai Ashkenazi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shai Ashkenazi has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Design and characterization of a photo-acoustic lens to generate tightly-focused and high frequency ultrasound

    by Hyoungwon Baac, Tao Ling, Sheng-Wen Huang, Shai Ashkenazi, L. Jay Guo

    Ultrasound microscopy uses high frequency (>40 MHz) ultrasound to produce high resolution images. For high resolution microscopy, broadband ultrasound generation and detection is necessary. Because high frequency ultrasound experiences significant absorption loss that results in weaker signals, it is desirable to focus the energy for microscopy applications, which also results in higher lateral resolution. In this work, thermo-elastically generated ultrasound was brought into a tight focus by shining a ns laser pulse onto a thin metal film-coated concave surface. For ultrasound detection, we use polymer microring resonators which have high frequency and wide band response. We experimentally obtained spatial and temporal characteristics of focused ultrasound by optical generation and detection. The 3-dB spot width of the focused ultrasound is ~50 μm. By frequency filtering over 40~100 MHz, 21 μm width is obtained. The temporal profile is close to the time-derivative of laser pulse waveform. Frequency domain analysis for the signal shows that high frequency loss mechanism of our system is dominated by angular directivity of the microring detector. The issues to improve high frequency response are discussed.

  • Low-noise wideband ultrasound detection using polymer microring resonators

    by Sheng-Wen Huang, Sung-Liang Chen, Tao Ling, Adam Maxwell, Matthew O’dOnnell, L. Jay Guo, Shai Ashkenazi

    Polymer microring resonators for low-noise, wideband ultrasound detection are presented. Using a nanoimprinting technique, we fabricated polymer microring resonators with a quality factor of 6000 resulting in high sensitivity to ultrasound. A noise-equivalent pressure of 0.23kPa over 1–75MHz and a detection bandwidth of over 90MHz at −3dB were measured. These results demonstrate the potential of polymer microring resonators for high-frequency ultrasound and photoacoustic imaging. For a typical photoacoustic imaging test case, the high sensitivity demonstrated in these devices would increase imaging depth by a factor of 3 compared to state-of-the-art polyvinylidene fluoride detectors.


  • Ratiometric photoacoustic sensing of pH using a “sonophore”

    by Thomas D. Horvath, Gwangseong Kim, Raoul Kopelman, Shai Ashkenazi

    This work describes ratiometric photoacoustic chemical sensing of pH, and describes how these measurements can be applied as a ratiometric biomedical imaging modality to image pH in intact biological tissue.


  • Polymer Microring Resonators for High-Frequency Ultrasound Detection and Imaging

    by Adam Maxwell, Sheng-Wen Huang, Tao Ling, Jin-Sung Kim, Shai Ashkenazi, L. Jay Guo

    Polymer microring resonators fabricated by nanoimprinting are presented as a means of ultrasound detection. Acoustic waves impinging on a ring-shaped optical resonator cause strain in the ring dimensions, modulating optical output. Basic acoustic and optical characteristics of the microring sensor are presented. Measurements at several frequencies show a high sensitivity and low noise-equivalent pressure. The angular response is determined by sensing the optoacoustic excitation of a 49 mum polyester microsphere and shows wide-angle sensitivity. A 1D array consisting of four microrings is demonstrated using wavelength multiplexing for addressing each element. The high sensitivity, bandwidth, and angular response make it a potentially useful sensor platform for many applications including high-frequency ultrasonic and photoacoustic imaging.


  • Open Access

    Photoacoustic probing of fluorophore excited state lifetime with application to oxygen sensing

    by Shai Ashkenazi, Shen-Wen Huang, Thomas Horvath, Yong-Eun L Koo, Raoul Kopelman, Raowl Kopelman

    A new method is developed to perform local measurements of fluorophore excited state lifetimes in turbid media without collecting the fluorescence emission. The method is based on a pump-probe approach where a first laser pulse excites the dye and then a second laser pulse is used for photoacoustic probing of the transient absorption. The photoacoustic response generated by the probe pulse is recorded by an ultrasound receiver. Repeating the measurement for increasing pump-probe time delays yields a series of photoacoustic signals that are used to extract the lifetime of the excited state. The method is validated by measuring the lifetime of an oxygen sensitive dye solution at different concentrations of dissolved oxygen. The dye is pumped with a 532-nm pulsed laser and the transient absorption at 740nm is probed using a second pulsed laser system. The photoacoustic-based results are in close agreement with those obtained from time-dependent fluorescent measurements. The method can be extended to photoacoustic lifetime imaging by using a receiver array instead of a single receiver. Potential applications of this method include tissue oxygen imaging for cancer diagnostics and mapping molecular events such as resonant energy transfer and ion collisions in a biological environment.


  • Hybrid Imaging System for Developing Novel Neural Contrast Agents

    by Russell S. Witte, Sheng-Wen Huang, Shai Ashkenazi, Matthew O'Donnell

    Neural contrast agents have a vast array of applications from molecular imaging to mapping membrane potential. We describe a hybrid neural recording system capable of ultrasonic, photoacoustic and optical imaging designed to develop and test the next-generation of neural contrast agents. Photoacoustic imaging (PA), in particular, provides optical contrast with good penetration and high spatial resolution, making it an attractive tool for noninvasive neural imaging. To demonstrate the system, we chose a commercial dye (NK2761) commonly used for optical imaging of neural tissue to enhance PA images of live lobster nerve cord. The abdominal segment was excised, stained and placed in a custom neural chamber. Photoacoustic and ultrasound images were collected using a clinical ultrasound scanner and a 10-MHz linear probe. A wavelength-tunable pulsed laser source (5 nsec, ~15 mJ) operating at 20 Hz produced PA waves. Longitudinal scans of the nerve cord were collected and displayed every 7 seconds. Without a contrast agent, the peak PA signal was 5 dB over noise. An additional 29 dB was achieved after the nerve was submerged in dye for 20 minutes. The contrast enhancement was consistent with the measured optical absorbance of the stained nerve. Photoacoustic images approached 200-mum spatial resolution. The hybrid system provided several hours of imaging, electrical stimulation and recording, serving as a robust testbed for developing novel contrast for neural applications.

  • Toward fiber-based high-frequency 3D ultrasound imaging

    by Sheng-Wen Huang, Shai Ashkenazi, Yang Hou, Russell S. Witte, Matthew O'Donnell

    We present a fiber-based optical detection system for high-frequency 3D ultrasound and photoacoustic imaging. Optically probing the surface of a thin polymer Fabry-Perot etalon defines the acoustic array geometry and element size. We have previously demonstrated wide bandwidth signal detection (>40 MHz) and element size on the order of 15 &mgr;m. By integrating an etalon into a photoacoustic imaging system, high-resolution 3D images were obtained. However, the previous system is limited for clinical applications because the etalon is rigidly attached to a free-space optical scanning system. To move etalon detector technology toward a practical clinical device, we designed a remote-probe system based on a fiber bundle. A fiber bundle, composed of 160,000 individual light guides of 8-&mgr;m diameter, delivers the optical probe to the etalon. Light coupled into a single guide creates an active element on the etalon surface. We successfully measured the ultrasound signals from 10 MHz and 50 MHz ultrasound transducers using a laser tunable around 1550 nm. With further progress on reducing the size of the etalon, it will be possible to build a practical device for in vivo high-frequency 3D ultrasound and photoacoustic imaging, especially for intravascular and endoscopic applications.


  • Integrated optics design concepts applied to high frequency ultrasound detection

    by Shai Ashkenazi, Matthew O'Donnell, L. Jay Guo, Chung-Yen Chao

    A novel application of polymer waveguide microring resonator for high-frequency ultrasound detection is presented. The device consists of a microring optical resonator that is coupled to a straight optical waveguide which serves as both input and output ports. Acoustic waves irradiating the ring waveguide induce strain that causes a change in the effective refractive index of optical waves propagating along the ring. The sharp wavelength dependence of the high Q-factor resonator enhances the optical response to the acoustic strain. High sensitivity has been demonstrated experimentally in the detection of broadband ultrasound pulses from a 10MHz transducer. WDM methods are proposed to extend the technique into an array of microrings for ultrasound imaging applications.