  • Ultrasound-assisted convection-enhanced delivery to the brain in vivo with a novel transducer cannula assembly

    by George K. Lewis, Zachary R. Schulz, Susan C. Pannullo, Teresa L. Southard, William L. Olbricht

    In convection-enhanced delivery (CED), drugs are infused locally into tissue through a cannula inserted into the brain parenchyma to enhance drug penetration over diffusion strategies. The purpose of this study was to demonstrate the feasibility of ultrasound-assisted CED (UCED) in the rodent brain in vivo using a novel, low-profile transducer cannula assembly (TCA) and portable, pocket-sized ultrasound system. Forty Sprague-Dawley rats (350-450 g) were divided into 2 equal groups (Groups 1 and 2). Each group was divided again into 4 subgroups (n = 5 in each). The caudate of each rodent brain was infused with 0.25 wt% Evans blue dye (EBD) in phosphate-buffered saline at 2 different infusion rates of 0.25 μl/minute (Group 1), and 0.5 μl/minute (Group 2). The infusion rates were increased slowly over 10 minutes from 0.05 to 0.25 μl/minute (Group 1) and from 0.1 to 0.5 μl/minute (Group 2). The final flow rate was maintained for 20 minutes. Rodents in the 4 control subgroups were infused using the TCA without ultrasound and without and with microbubbles added to the infusate (CED and CED + MB, respectively). Rodents in the 4 UCED subgroups were infused without and with microbubbles added to the infusate (UCED and UCED + MB) using the TCA with continuous-wave 1.34-MHz low-intensity ultrasound at a total acoustic power of 0.11 ± 0.005 W and peak spatial intensity at the cannula tip of 49.7 mW/cm(2). An additional 4 Sprague-Dawley rats (350-450 g) received UCED at 4 different and higher ultrasound intensities at the cannula tip ranging from 62.0 to 155.0 mW/cm(2) for 30 minutes. The 3D infusion distribution was reconstructed using MATLAB analysis. Tissue damage and morphological changes to the brain were assessed using H & E. The application of ultrasound during infusion (UCED and UCED + MB) improved the volumetric distribution of EBD in the brain by a factor of 2.24 to 3.25 when there were no microbubbles in the infusate and by a factor of 1.16 to 1.70 when microbubbles were added to the infusate (p < 0.001). On gross and histological examination, no damage to the brain tissue was found for any acoustic exposure applied to the brain. The TCA and ultrasound device show promise to improve the distribution of infused compounds during CED. The results suggest further studies are required to optimize infusion and acoustic parameters for small compounds and for larger molecular weight compounds that are representative of promising antitumor agents. In addition, safe levels of ultrasound exposure in chronic experiments must be determined for practical clinical evaluation of UCED. Extension of these experiments to larger animal models is warranted to demonstrate efficacy of this technique.


  • Miniature kilohertz-frequency ultrasound implant for brain drug delivery.

    by John C. Foo, Susan C. Pannullo, William L. Olbricht, Michael L. Shuler, George K. Lewis

  • Time-reversal techniques in ultrasound-assisted convection-enhanced drug delivery to the brain: Technology development and in vivo evaluation.

    by George K. Lewis, Laurent Fillinger, William L. Olbricht, Armen Sarvazyan

    We describe a drug delivery method that combines time‐reversal acoustics (TRA) with convection‐enhanced delivery (CED) to improve the delivery of therapeutics to the interstitium of the brain. The ultrasound‐assisted CED approach (UCED) circumvents the blood‐brain barrier by infusing compounds through a cannula that is inserted into the brain while simultaneously delivering ultrasound to improve the penetration of pharmaceuticals. CED without ultrasound‐assistance has been used to treat a variety of neural disorders, including glioblastoma multiforme, a malignancy that presents a very poor prognosis for patients. The mixed clinical success of CED suggests that the technique needs to be improved. We describe a novel TRA system that is used to infuse fluids into the brain parenchyma while simultaneously exposing the tissue to safe levels of 1‐MHz, low‐intensity, ultrasound energy. The system includes a com‐bined infusion needle‐hydrophone, a 10‐channel ultralow‐output impedance amplifier, a broad‐band ultrasound resonator, and MATLAB ®‐based, TRA control and user‐interface. TRA allows easy coupling of ultrasound therapy through the skull without complex phase‐correction and array design. The smart targeting UCED system has been tested in vivo and results show that it provides 1‐mm spatial resolution for UCED and improves tracer distribution in the brain six to eight times over CED alone.


  • Development of a portable therapeutic and high intensity ultrasound system for military, medical, and research use

    by George K. Lewis, William L. Olbricht

    We have developed a portable high power ultrasound system with a very low output impedance amplifier circuit (less than 0.3 Ω ) that can transfer more than 90% of the energy from a battery supply to the ultrasound transducer. The system can deliver therapeutic acoustical energy waves at lower voltages than those in conventional ultrasound systems because energy losses owing to a mismatched impedance are eliminated. The system can produce acoustic power outputs over the therapeutic range (greater then 50 W) from a PZT-4, 1.54 MHz, and 0.75 in diameter piezoelectric ceramic. It is lightweight, portable, and powered by a rechargeable battery. The portable therapeutic ultrasound unit has the potential to replace “plug-in” medical systems and rf amplifiers used in research. The system is capable of field service on its internal battery, making it especially useful for military, ambulatory, and remote medical applications.


  • Open Access

    Cost-effective broad-band electrical impedance spectroscopy measurement circuit and signal analysis for piezo-materials and ultrasound transducers

    by George K Lewis, William Olbricht

    This paper explains the circuitry and signal processing to perform electrical impedance spectroscopy on piezoelectric materials and ultrasound transducers. Here, we measure and compare the impedance spectra of 2−5 MHz piezoelectrics, but the methodology applies for 700 kHz–20 MHz ultrasonic devices as well. Using a 12 ns wide 5 volt pulsing circuit as an impulse, we determine the electrical impedance curves experimentally using Ohm's law and fast Fourier transform (FFT), and compare results with mathematical models. The method allows for rapid impedance measurement for a range of frequencies using a narrow input pulse, digital oscilloscope and FFT techniques. The technique compares well to current methodologies such as network and impedance analyzers while providing additional versatility in the electrical impedance measurement. The technique is theoretically simple, easy to implement and completed with ordinary laboratory instrumentation for minimal cost.