Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shizhi Qian has a total of 91 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Application of Artificial Neural Network to Nucleic Acid Analysis: Accurate Discrimination for Untypical Real-Time Fluorescence Curves With High Specificity and Sensitivity

    by Guijun Miao, Xiaodan Jiang, Yunping Tu, Lulu Zhang, Duli Yu, Shizhi Qian, Xianbo Qiu

    As a division of polymerase chain reaction (PCR), convective PCR (CPCR) is able to achieve highly efficient thermal cycling based on free thermal convection with pseudo-isothermal heating, which could be beneficial to point-of-care (POC) nucleic acid analysis. Similar to traditional PCR or isothermal amplification, due to a couple of issues, e.g., reagent, primer design, reactor, reaction dynamics, amplification status, temperature and heating condition, and other reasons, in some cases of CPCR tests, untypical real-time fluorescence curves with positive or negative tests will show up. Especially, when parts of the characteristics between untypical low-positive and negative tests are mixed together, it is difficult to discriminate between them using traditional cycle threshold (Ct) value method. To handle this issue which may occur in CPCR, traditional PCR or isothermal amplification, as an example, instead of using complicated mathematical modeling and signal processing strategy, an artificial intelligence (AI) classification method with artificial neural network (ANN) modeling is developed to improve the accuracy of nucleic acid detection. It has been proven that both the detection specificity and sensitivity can be significantly improved even with a simple ANN model. It can be estimated that the developed method based on AI modeling can be adopted to solve similar problem with PCR or isothermal amplification methods.


  • Open Access

    Editorial for the Special Issue on Micromachines for Non-Newtonian Microfluidics

    by Lanju Mei, Shizhi Qian

    Microfluidics has seen a remarkable growth over the past few decades, with its extensive applications in engineering, medicine, biology, chemistry, etc


  • Open Access

    Electroosmotic Flow of Viscoelastic Fluid through a Constriction Microchannel

    by Jianyu Ji, Shizhi Qian, Zhaohui Liu

    Electroosmotic flow (EOF) has been widely used in various biochemical microfluidic applications, many of which use viscoelastic non-Newtonian fluid. This study numerically investigates the EOF of viscoelastic fluid through a 10:1 constriction microfluidic channel connecting two reservoirs on either side. The flow is modelled by the Oldroyd-B (OB) model coupled with the Poisson–Boltzmann model. EOF of polyacrylamide (PAA) solution is studied as a function of the PAA concentration and the applied electric field. In contrast to steady EOF of Newtonian fluid, the EOF of PAA solution becomes unstable when the applied electric field (PAA concentration) exceeds a critical value for a fixed PAA concentration (electric field), and vortices form at the upstream of the constriction. EOF velocity of viscoelastic fluid becomes spatially and temporally dependent, and the velocity at the exit of the constriction microchannel is much higher than that at its entrance, which is in qualitative agreement with experimental observation from the literature. Under the same apparent viscosity, the time-averaged velocity of the viscoelastic fluid is lower than that of the Newtonian fluid.


  • Open Access

    Editorial for the Special Issue on Micro/Nano-Chip Electrokinetics, Volume III

    by Shizhi Qian, Xiangchun Xuan

    With the support from contributors and the help from peer reviewers, the Special Issue on Micro/Nano-Chip Electrokinetics (Volume III) published fourteen regular research articles and one review article


  • Free convective PCR: From principle study to commercial applications—A critical review

    by Guijun Miao, Lulu Zhang, Jing Zhang, Shengxiang Ge, Ningshao Xia, Shizhi Qian, Duli Yu, Xianbo Qiu


  • Open Access

    Tunable-Focus Liquid Lens through Charge Injection

    by Shizhi Qian, Wenxiang Shi, Huai Zheng, Zhaohui Liu

    Liquid lenses are the simplest and cheapest optical lenses, and various studies have been conducted to develop tunable-focus liquid lenses. In this study, a simple and easily implemented method for achieving tunable-focus liquid lenses was proposed and experimentally validated. In this method, charges induced by a corona discharge in the air were injected into dielectric liquid, resulting in “electropressure” at the interface between the air and the liquid. Through a 3D-printed U-tube structure, a tunable-focus liquid lens was fabricated and tested. Depending on the voltage, the focus of the liquid lens can be adjusted in large ranges (−∞ to −9 mm and 13.11 mm to ∞). The results will inspire various new liquid-lens applications.


  • Open Access

    Electroosmotic Flow of Viscoelastic Fluid in a Nanochannel Connecting Two Reservoirs

    by Lanju Mei, Shizhi Qian

    Electroosmotic flow (EOF) of viscoelastic fluid with Linear Phan-Thien–Tanner (LPTT) constitutive model in a nanochannel connecting two reservoirs is numerically studied. For the first time, the influence of viscoelasticity on the EOF and the ionic conductance in the micro-nanofluidic interconnect system, with consideration of the electrical double layers (EDLs), is investigated. Regardless of the bulk salt concentration, significant enhancement of the flow rate is observed for viscoelastic fluid compared to the Newtonian fluid, due to the shear thinning effect. An increase in the ionic conductance of the nanochannel occurs for the viscoelastic fluid. The enhancement of the ionic conductance is significant under the overlapping EDLs condition.


  • Computational Design of a Single Heater Convective Polymerase Chain Reaction for Point-of-Care

    by Jung Il Shu, Oktay Baysal, Shizhi Qian, Xianbo Qiu

    Recently, researchers have started working to develop polymerase chain reaction (PCR) devices as a means for point-of-care (POC) applications. Among the requirements are portability, affordability, and performing reliably and quickly. Proposed by the present study is a process to design a convective-PCR (CPCR) device with only a single heater. It is assumed that such a design developed using microfluidics and capillary tube should help make a CPCR to be portable and more economical for POC use. One of the challenges is to achieve steadily the prerequisite three temperature zones with a single heater. It is demonstrated that this can be done with the present methodology. The underlying physics of the convection driving the CPCR function is mathematically modeled, then verified by our experimental results. In search of better designs, the following parameters that affect the CPCR performance are considered: the heater's height, and the diameter, the height, and the wall thickness of the capillary tube. A large design space consisting of design candidates is defined by combining the values within the range of each of these parameters. The results of the corresponding design cases are obtained from our mathematical model, and the performance of each case is evaluated by their deoxyribonucleic acid (DNA) doubling time. The two best CPCR performing reactors are selected and discussed. It is, therefore, demonstrated that the present methodology is capable of enhancing the CPCR reactor performance with a single heater.


  • Open Access

    Editorial for the Special Issue on Micro/Nano-Chip Electrokinetics, Volume II

    by Xiangchun Xuan, Shizhi Qian

  • Open Access

    Electroosmotic Flow of Viscoelastic Fluid in a Nanoslit

    by Lanju Mei, Hongna Zhang, Hongxia Meng, Shizhi Qian

    The electroosmotic flow (EOF) of viscoelastic fluid in a long nanoslit is numerically studied to investigate the rheological property effect of Linear Phan-Thien-Tanner (LPTT) fluid on the fully developed EOF. The non-linear Poisson-Nernst-Planck equations governing the electric potential and the ionic concentration distribution within the channel are adopted to take into account the effect of the electrical double layer (EDL), including the EDL overlap. When the EDL is not overlapped, the velocity profiles for both Newtonian and viscoelastic fluids are plug-like and increase sharply near the charged wall. The velocity profile resembles that of pressure-driven flow when the EDL is overlapped. Regardless of the EDL thickness, apparent increase of velocity is obtained for viscoelastic fluid of larger Weissenberg number compared to the Newtonian fluid, indicating the shear thinning behavior of the LPTT fluid. The effect of the Weissenberg number on the velocity distribution is less significant as the degree of EDL overlapping increases, due to the overall decrease of the shear rate. The increase (decrease) of polymer extensibility (viscosity ratio) also enhances the EOF of viscoelastic fluid.