SHSean J. Hart

Sean J. Hart

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sean J. Hart has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    On-the-fly cross flow laser guided separation of aerosol particles based on size, refractive index and density–theoretical analysis

    by A. A. Lall, A. Terray, S. J. Hart

    Laser separation of particles is achieved using forces resulting from the momentum exchange between particles and photons constituting the laser radiation. Particles can experience different optical forces depending on their size and/or optical properties, such as refractive index. Thus, particles can move at different speeds in the presence of an optical force, leading to spatial separations. In this paper, we present a theoretical analysis on laser separation of non-absorbing aerosol particles moving at speeds (1-10 cm/sec) which are several orders of magnitude greater than typical particle speeds used in previous studies in liquid medium. The calculations are presented for particle deflection by a loosely focused Gaussian 1064 nm laser, which simultaneously holds and deflects particles entrained in flow perpendicular to their direction of travel. The gradient force holds the particles against the viscous drag for a short period of time. The scattering force simultaneously pushes the particles, perpendicular to the flow, during this period. Our calculations show particle deflections of over 2500 µm for 15 µm aerosol particles, and a separation of over 1500 µm between 5 µm and 10 µm particles when the laser is operated at 10W. We show that a separation of about 421 µm can be achieved between two particles of the same size (10 µm) but having a refractive index difference of 0.1. Density based separations are also possible. Two 10 µm particles with a density difference of 600 kg/m3 can be separated by 193 µm. Examples are shown for separation distances between polystyrene, poly(methylmethacrylate), silica and water particles. These large laser guided deflections represent a novel achievement for optical separation in the gas phase.


  • Analytical optical chromatography measurement of complex microparticles

    by Joseph D. Taylor, Colin G. Hebert, Alex Terray, Sean J. Hart

    A variation on the typical optical chromatography system was used to measure optical force differentials of complex micro-particles that have been assembled or fabricated using bead chemistries, bio-molecule tethers, or biological bead coatings. A number of bio-inspired particle types have been created to help elucidate the origin of optical force differentials that are known or suspected in biological systems such as bacterial cells / spores, and mammalian cells. A number of optical force measurements will be presented for a variety of micro-fabricated particles and the results and capabilities discussed.


  • Analytical particle measurements in an optical microflume

    by Joseph D. Taylor, Alex Terray, Sean J. Hart


  • “Off-the-shelf” 3-D microfluidic nozzle

    by Alex Terray, Sean J. Hart

    We present the construction and operation of a microfluidic nozzle created using several standard fluidic parts available commercially. By elegantly combining several pieces from a standard assembly, a capillary and a few other standard parts, we were able to develop a novel device. Using this device, precise axisymmetric flow focusing of particles was achieved and observed at the exit of the nozzle and within a connected microfluidic device several centimetres away. Sheath and core flow rates were varied to show influence and control over the width of the focused particles.


  • Cascade optical chromatography for sample fractionation

    by Alex Terray, Joseph D. Taylor, Sean J. Hart

    Optical chromatography involves the elegant combination of opposing optical and fluid drag forces on colloidal samples within microfluidic environments to both measure analytical differences and fractionate injected samples. Particles that encounter the focused laser beam are trapped axially along the beam and are pushed upstream from the laser focal point to rest at a point where the optical and fluid forces on the particle balance. In our recent devices particles are pushed into a region of lower microfluidic flow, where they can be retained and fractionated. Because optical and fluid forces on a particle are sensitive to differences in the physical and chemical properties of a sample, separations are possible. An optical chromatography beam focused to completely fill a fluid channel is operated as an optically tunable filter for the separation of inorganic, polymeric, and biological particle samples. We demonstrate this technique coupled with an advanced microfluidic platform and show how it can be used as an effective method to fractionate particles from an injected multicomponent sample. Our advanced three-stage microfluidic design accommodates three lasers simultaneously to effectively create a sequential cascade optical chromatographic separation system.


  • Numerical simulation of an optical chromatographic separator

    by Alex Terray, H. D. Ladouceur, Mark Hammond, Sean J. Hart

    Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.


  • Preparative optical chromatography with external collection and analysis

    by Sean J. Hart, Alex Terray, Jonathan Arnold, Tomasz A. Leski

    Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.


  • Optical chromatography for concentration of biological samples

    by Sean J. Hart, Alex Terray, Jonathan Arnold, Tomasz A. Leski

    The application of laser radiation as a method for the manipulation of microscopic particle suspensions for biological, thermodynamic and microfluidic interests has brought about a revolution in micro-scale research across many different scientific disciplines. It has been shown that a diffraction limited focused laser can be used to trap microscopic particles whose refractive index is greater than their surrounding solvent. Termed Optical Trapping, work in this arena has yielded, new methods, techniques and applications that have flourished, and applications of this technology to areas of research involving microscopic systems for analysis, detection, separation and concentration have blossomed. A related technique, Optical Chromatography, used for particle separation involves loosely focusing a laser into a fluid flowing opposite to the direction of laser propagation. When microscopic particles in the flow path encounter this beam they are trapped axially along the beam and are pushed upstream from the laser focal point to rest at a point where the optical and fluid forces on the particle balance. Because optical and fluid forces are sensitive to differences in the physical and chemical properties of a particle, fine separations are possible. Recently, this method has been used to separate spores of different Bacillus species based on their optical and fluidic properties. We will describe how an optical chromatography beam directed into a tailored flow environment housed in a glass flowcell, has been adapted to operate as an optically tunable filter for the concentration or bioenrichment of colloidal and biological samples. Application of these methods and further design of fluidic and optical environments will allow for more specific identification, concentration and separation of many more microscopic particle and biological suspensions.


  • Refractive Index Determination of Biological Particles

    by Sean J. Hart, Tomasz A. Leski

    Refractive indices of biological particles have been determined using a new quantitative method based upon phase contrast immersion spectrometry. The new technique is sensitive, accurate, and requires only an optical transmission spectrophotometer and index matching fluids. The method was developed and tested using colloidal silica standard samples. Refractive indices for bacterial spores have been determined, and the results compared favorably with available data in the literature.


  • Discovery of a Significant Optical Chromatographic Difference between Spores of Bacillus anthracis and Its Close Relative, Bacillus thuringiensis

    by Sean J. Hart, Alex Terray, Tomasz A. Leski, Jonathan Arnold, Rhonda Stroud

    A significant difference between two closely related Bacillus spores has been discovered using optical chromatography. This difference can be harnessed for the separation of microscopic particles using opposing laser and fluid flow forces. Particles of different size, composition, and shape experience different optical and fluid forces and come to rest at unique equilibrium positions where the two forces balance. Separations in excess of 600 μm have been observed between Bacillus anthracis Sterne strain and its genetic relative, Bacillus thuringiensis. These findings open new possibilities for detection and characterization of the biological warfare agent, B. anthracis, the causative agent of anthrax, the deadly mammalian disease. The large optical separation between these species is surprising given their close genetic relationship but may be explained by differences in their shape and exosporium morphology, which may result in differences in fluid drag force. The observation of large differences due to less common variables indicates the complex nature of the force balance in optical chromatography, which may in the future be used to separate and characterize microbiological samples. In general, the discovery of such large differences between such closely related biological species suggests new possibilities for the separation and characterization of microorganisms using the full range of emerging techniques that employ radiation pressure (optical filtering, laser tweezers, optical chromatography, etc.).