TYTakao Yasui

Takao Yasui

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Takao Yasui has a total of 21 co-authors. Here are the top co-authors by number of shared publications:

  • Yoshinobu Baba

    Department of Applied Chemistry, Graduate School of Engineering, Nagoya University

    6 shared publications
  • Noritada Kaji

    Department of Applied Chemistry, Graduate School of Engineering, Nagoya University

    5 shared publications
  • Yukihiro Okamoto

    Department of Applied Chemistry, Graduate School of Engineering, Nagoya University

    4 shared publications
  • Keiko Osato

    Department of Applied Chemistry, Graduate School of Engineering, Nagoya University

    3 shared publications
  • Manabu Tokeshi

    Department of Applied Chemistry, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan

    3 shared publications
  • Manabu Tokeshi

    Faculty of Engineering Hokkaido University Sapporo Japan

    3 shared publications

Latest Publications

  • Open Access

    Confocal Microscopic Evaluation of Mixing Performance for Three-Dimensional Microfluidic Mixer

    by Takao Yasui, Yusuke Omoto, Keiko Osato, Noritada Kaji, Norikazu Suzuki, Toyohiro Naito, Yukihiro Okamoto, Manabu Tokeshi, Eiji Shamoto, Yoshinobu Baba

    We developed a confocal microscopic method for a quantitative evaluation of the mixing performance of a three-dimensional microfluidic mixer. We fabricated a microfluidic baker’s transformation (MBT) mixer as a three-dimensional passive-type mixer for the efficient mixing of solutions. Although the MBT mixer is one type of ideal mixers, it is hard to evaluate its mixing performance, since the MBT mixer is based on several cycles of complicated three-dimensional microchannel structures. We applied the method developed here to evaluate the mixing of water and a fluorescein isothiocyanate (FITC; diffusion coefficient, 4.9 × 10−10 m2 s−1) solution by the MBT mixer. This method enables us to capture vertical section images for the fluid distributions of FITC and water at different three-dimensional microchannel structures of the MBT device. These images are in good agreement with those of mixing images based on numerical simulations. The mixing ratio could be calculated by the fluorescence intensity at each pixel of the vertical section image; complete mixing is recognized by a mixing ratio of more than 90%. The mixing ratios are measured at different cycles of the MBT mixer by changing the flow rate; the mixing performance is evaluated by comparisons with the mixing ratio of the straight microchannel without the MBT mixer.


  • Open Access

    Development of Mass-Producible Rapid Mixer Based on Baker's Transformation

    by Yusuke Omoto, Takashi Kato, Norikazu Suzuki, Takao Yasui, Keiko Osato, Noritada Kaji, Manabu Tokeshi, Yoshinobu Baba, Yasuhiko Sakai, Eiji Shamoto

  • Characterization of low viscosity polymer solutions for microchip electrophoresis of non-denatured proteins on plastic chips

    by Takao Yasui, Mohamad Reza Mohamadi, Noritada Kaji, Yukihiro Okamoto, Manabu Tokeshi, Yoshinobu Baba

    In this paper, we study characteristics of polymers (methylcellulose, hypromellose ((hydroxypropyl)methyl cellulose), poly(vinylpyrrolidone), and poly(vinyl alcohol)) with different chemical structures for microchip electrophoresis of non-denatured protein samples in a plastic microchip made of poly(methyl methacrylate) (PMMA). Coating efficiency of these polymers for controlling protein adsorption onto the channel surface of the plastic microchip, wettability of the PMMA surface, and electroosmotic flow in the PMMA microchannels in the presence of these polymers were compared. Also relative electrophoretic mobility of protein samples in solutions of these polymers was studied. We showed that when using low polymer concentrations (lower than the polymer entanglement point) where the sieving effect is substantially negligible, the interaction of the samples with the polymer affected the electrophoretic mobility of the samples. This effect can be used for achieving better resolution in microchip electrophoresis of protein samples.


  • Electroosmotic Flow in Microchannels with Nanostructures

    by Takao Yasui, Noritada Kaji, Mohamad Reza Mohamadi, Yukihiro Okamoto, Manabu Tokeshi, Yasuhiro Horiike, Yoshinobu Baba

    Here we report that nanopillar array structures have an intrinsic ability to suppress electroosmotic flow (EOF). Currently using glass chips for electrophoresis requires laborious surface coating to control EOF, which works as a counterflow to the electrophoresis mobility of negatively charged samples such as DNA and sodium dodecyl sulfate (SDS) denatured proteins. Due to the intrinsic ability of the nanopillar array to suppress the EOF, we carried out electrophoresis of SDS–protein complexes in nanopillar chips without adding any reagent to suppress protein adsorption and the EOF. We also show that the EOF profile inside a nanopillar region was deformed to an inverse parabolic flow. We used a combination of EOF measurements and fluorescence observations to compare EOF in microchannel, nanochannel, and nanopillar array chips. Our results of EOF measurements in micro- and nanochannel chips were in complete agreement with the conventional equation of the EOF mobility (μEOF-channel = αCi–0.5, where Ci is the bulk concentration of the i-ions and α differs in micro- and nanochannels), whereas EOF in the nanopillar chips did not follow this equation. Therefore we developed a new modified form of the conventional EOF equation, μEOF-nanopillar ≈ β[Ci – (Ci2/Ni)], where Ni is the number of sites available to i-ions and β differs for each nanopillar chip because of different spacings or patterns, etc. The modified equation of the EOF mobility that we proposed here was in good agreement with our experimental results. In this equation, we showed that the charge density of the nanopillar region, that is, the total number of nanopillars inside the microchannel, affected the suppression of EOF, and the arrangement of nanopillars into a tilted or square array had no effect on it.


  • Microfluidic baker's transformation device for three-dimensional rapid mixing

    by Takao Yasui, Yusuke Omoto, Keiko Osato, Noritada Kaji, Norikazu Suzuki, Toyohiro Naito, Masaki Watanabe, Yukihiro Okamoto, Manabu Tokeshi, Eiji Shamoto, et al.

    We developed a new passive-type micromixer based on the baker's transformation and realized a fast mixing of a protein solution, which has lower diffusion constant. The baker's transformation is an ideal mixing method, but there is no report on the microfluidic baker's transformation (MBT), since it is required to fabricate the complicated three-dimensional (3D) structure to realize the MBT device. In this note, we successfully fabricate the MBT device by using precision diamond cutting of an oxygen-free copper substrate for the mould fabrication and PDMS replication. The MBT device with 10.4 mm mixing length enables us to achieve complete mixing of a FITC solution (D = 2.6 × 10−10 m2s−1) within 51 ms and an IgG solution (D = 4.6 × 10−11 m2s−1) within 306 ms. Its mixing speed is 70-fold higher for a FITC solution and 900-fold higher for an IgG solution than the mixing speed by the microchannel without MBT structures. The Péclet number to attain complete mixing in the MBT device is estimated to be 6.9 × 104.


  • DNA Separation in Nanowall Array Chips

    by Takao Yasui, Noritada Kaji, Ryo Ogawa, Shingi Hashioka, Manabu Tokeshi, Yasuhiro Horiike, Yoshinobu Baba

    A nanowall array structure was fabricated on a quartz chip as a separation matrix of DNA fragments, and a 30 s separation was realized for a mixture of DNA fragments (48.5 and 1 kbp fragments) by applying the electric voltage. A longer DNA fragment migrates faster than a shorter one in a nanowall array chip, and it is completely different from the separation of DNA based on gel electrophoresis, nanopillar chips, and nanoparticle array chips. Although the result is similar to DNA separation by entropic trapping, it could not be fully explained by entropic trapping phenomena. Direct observation of single-DNA molecular dynamics inside a nanowall array structure indicates that both confined elongation and relaxation recoiling of a DNA molecule occur, and an elongated DNA molecule migrates faster than a recoiled DNA molecule. Numerical fitting of DNA molecular dynamics reveals that the balance between times for the transverse of a DNA molecule in the nanowall array chip and the relaxation-recoiling of a DNA molecule governs the separation of DNA.