Lasse Välimaa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Lasse Välimaa has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Kim Pettersson
University of Turku
4 shared publications- Matti Karp
Department of Chemistry and Bioengineering, Tampere University of Technology, Korkeakoulunkatu 8, Tampere, Finland
3 shared publications Timo Lövgren
3 shared publicationsJaana Rosenberg
2 shared publications- Anne Mäntymaa
Tampere University of Technology 1 , Korkeakoulunkatu 3, 33720 Tampere, Finland
1 shared publication Hannu Kojola
Kojola Hannu (private enterprise)
1 shared publication
Latest Publications
- 1 December 2011
- Published by AIP Publishing in Biomicrofluidics
- Vol. 5 (4) , 046504-4650411
The effects of laser welding on heterogeneous immunoassay performance in a microfluidic cartridge
Sealing of a microfluidic cartridge is a challenge, because the cartridge commonly contains heat-sensitive biomolecules that must also be protected from contamination. In addition, the objective is usually to obtain a sealing method suitable for mass production. Laser welding is a rapid technique that can be accomplished with low unit costs. Even though the technique has been widely adopted in industry, the literature on its use in microfluidic applications is not large. This paper is the first to report the effects of laser welding on the performance of the heterogeneous immunoassay in a polystyrene microfluidic cartridge in which biomolecules are immobilized into the reaction surface of the cartridge before sealing. The paper compares the immunoassay performance of microfluidic cartridges that are sealed either with an adhesive tape or by use of laser transmission welding. The model analyte used is thyroid stimulating hormone (TSH). The results show that the concentration curves in the laser-welded cartridges are very close to the curves in the taped cartridges. This indicates, first, that laser welding does not cause any significant reduction in immunoassay performance, and second, that the polystyrene cover does not have significant effect on the signal levels. Interestingly, the coefficients of variance between parallel samples were lower in the laser-welded cartridges than in the taped cartridges.
- 1 December 2011
- Published by AIP Publishing in Biomicrofluidics
- Vol. 5 (4) , 046504-4650411
The effects of laser welding on heterogeneous immunoassay performance in a microfluidic cartridge
Sealing of a microfluidic cartridge is a challenge, because the cartridge commonly contains heat-sensitive biomolecules that must also be protected from contamination. In addition, the objective is usually to obtain a sealing method suitable for mass production. Laser welding is a rapid technique that can be accomplished with low unit costs. Even though the technique has been widely adopted in industry, the literature on its use in microfluidic applications is not large. This paper is the first to report the effects of laser welding on the performance of the heterogeneous immunoassay in a polystyrene microfluidic cartridge in which biomolecules are immobilized into the reaction surface of the cartridge before sealing. The paper compares the immunoassay performance of microfluidic cartridges that are sealed either with an adhesive tape or by use of laser transmission welding. The model analyte used is thyroid stimulating hormone (TSH). The results show that the concentration curves in the laser-welded cartridges are very close to the curves in the taped cartridges. This indicates, first, that laser welding does not cause any significant reduction in immunoassay performance, and second, that the polystyrene cover does not have significant effect on the signal levels. Interestingly, the coefficients of variance between parallel samples were lower in the laser-welded cartridges than in the taped cartridges.
- 3 May 2008
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 391 (6) , 2135-2144
Streptavidin-coated spot surfaces for sensitive immunoassays using fluorescence surface readout
Direct measurement of time-resolved fluorescence from a washed surface of an immunoassay well constitutes an advantage compared with label development options involving signal generation in solution. Epi-fluorometric detection collects the signal from only a small part of the microtiter well’s bottom surface and it is inadequate for the optimal assay sensitivity when using binding surfaces introduced by large coating volume. This study reports on the use of streptavidin-coated spots intended to condense the binding of the labeled antibodies to coincide with the excitation beam. The spots were generated in special microtiter wells containing 2.5-mm, 3.5-mm, and 4.5-mm diameter indentations by adsorption from liquid droplets containing either native (SAv) or modified high-capacity (GA-SAv) streptavidin. The SAv-coated and GA-SAv-coated spots exhibited maximum Eu–biotin binding densities of 0.080 and 0.47 pmol/mm2, respectively. A sandwich-type immunoassay of thyroid-stimulating hormone (TSH) provided a fivefold to sixfold increase in the signal-to-background ratios of the spot assay and an equivalent improvement in the detection limit (DL < 0.01 mU/L) compared with a reference assay.
- 3 May 2008
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 391 (6) , 2135-2144
Streptavidin-coated spot surfaces for sensitive immunoassays using fluorescence surface readout
Direct measurement of time-resolved fluorescence from a washed surface of an immunoassay well constitutes an advantage compared with label development options involving signal generation in solution. Epi-fluorometric detection collects the signal from only a small part of the microtiter well’s bottom surface and it is inadequate for the optimal assay sensitivity when using binding surfaces introduced by large coating volume. This study reports on the use of streptavidin-coated spots intended to condense the binding of the labeled antibodies to coincide with the excitation beam. The spots were generated in special microtiter wells containing 2.5-mm, 3.5-mm, and 4.5-mm diameter indentations by adsorption from liquid droplets containing either native (SAv) or modified high-capacity (GA-SAv) streptavidin. The SAv-coated and GA-SAv-coated spots exhibited maximum Eu–biotin binding densities of 0.080 and 0.47 pmol/mm2, respectively. A sandwich-type immunoassay of thyroid-stimulating hormone (TSH) provided a fivefold to sixfold increase in the signal-to-background ratios of the spot assay and an equivalent improvement in the detection limit (DL < 0.01 mU/L) compared with a reference assay.
- 20 January 2006
- Published by Elsevier in Journal of Immunological Methods
- Vol. 308 (1-2) , 203-215
Comparison study of streptavidin-coated microtitration plates
- 20 January 2006
- Published by Elsevier in Journal of Immunological Methods
- Vol. 308 (1-2) , 203-215
Comparison study of streptavidin-coated microtitration plates
- 1 August 2004
- Published by Elsevier in Analytical Biochemistry
- Vol. 331 (2) , 376-384
Quantification of streptavidin adsorption in microtitration wells
- 1 August 2004
- Published by Elsevier in Analytical Biochemistry
- Vol. 331 (2) , 376-384
Quantification of streptavidin adsorption in microtitration wells
- 1 May 2004
- Published by Elsevier in Analytical Biochemistry
Quantification of streptavidin adsorption in microtitration wells
- 1 May 2004
- Published by Elsevier in Analytical Biochemistry
Quantification of streptavidin adsorption in microtitration wells
- 3 December 2002
- Published by American Chemical Society (ACS) in Bioconjugate Chemistry
- Vol. 14 (1) , 103-111
A High-Capacity Streptavidin-Coated Microtitration Plate
A majority of current immunoassays rely on capturing a specific analyte on a solid phase to allow the separation of the bound analyte from nonbound components. Streptavidin-coated microtitration plates are widely used for immobilization of capturing antibodies, since they provide a generic surface for immobilization of any biotinylated molecule and preserve biomolecule activity much better than direct passive adsorption. Our trials to further improve the properties of the plates resulted in a development of a modified plate, which has higher binding capacity than currently used control plate. The modified coat was prepared by cross-linking streptavidin chemically prior to adsorption onto the microtitration well surfaces. The binding capacities of the plates were measured with biotinylated, europium-labeled molecules and labeled antigen. The immunoassay performance of the plates was studied with noncompetitive, sandwich-type assays of prostate specific antigen (PSA) and human chorionic gonadotropin (hCG). The maximum immobilization capacity of the modified plate was up to 2.5 times higher than that of the control plate. The higher binding capacity was especially emphasized with small-size molecules. The modified high capacity plate increased the linear ranges of the immunoassays and thus delayed the high-dose hook effect. At high antigen concentrations the signal increased up to 59%, and at the conventional linear ranges of the assays, the increase was up to 29%. We conclude that the modified coating method will be valuable for the future miniaturized systems, where high immobilization capacity is needed at limited areas.
- 3 December 2002
- Published by American Chemical Society (ACS) in Bioconjugate Chemistry
- Vol. 14 (1) , 103-111
A High-Capacity Streptavidin-Coated Microtitration Plate
A majority of current immunoassays rely on capturing a specific analyte on a solid phase to allow the separation of the bound analyte from nonbound components. Streptavidin-coated microtitration plates are widely used for immobilization of capturing antibodies, since they provide a generic surface for immobilization of any biotinylated molecule and preserve biomolecule activity much better than direct passive adsorption. Our trials to further improve the properties of the plates resulted in a development of a modified plate, which has higher binding capacity than currently used control plate. The modified coat was prepared by cross-linking streptavidin chemically prior to adsorption onto the microtitration well surfaces. The binding capacities of the plates were measured with biotinylated, europium-labeled molecules and labeled antigen. The immunoassay performance of the plates was studied with noncompetitive, sandwich-type assays of prostate specific antigen (PSA) and human chorionic gonadotropin (hCG). The maximum immobilization capacity of the modified plate was up to 2.5 times higher than that of the control plate. The higher binding capacity was especially emphasized with small-size molecules. The modified high capacity plate increased the linear ranges of the immunoassays and thus delayed the high-dose hook effect. At high antigen concentrations the signal increased up to 59%, and at the conventional linear ranges of the assays, the increase was up to 29%. We conclude that the modified coating method will be valuable for the future miniaturized systems, where high immobilization capacity is needed at limited areas.