WSWei Shen

Wei Shen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wei Shen has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Paper‐Based Blood Typing Device That Reports Patient’s Blood Type “in Writing”

    by Miaosi Li, Junfei Tian, Mohammad Al‐Tamimi, Wei Shen


  • Top Cited Papers

    Paper‐Based Blood Typing Device That Reports Patient’s Blood Type “in Writing”

    by Miaosi Li, Junfei Tian, Mohammad Al‐Tamimi, Wei Shen


  • Printed two-dimensional micro-zone plates for chemical analysis and ELISA

    by Junfei Tian, Xu Li, Wei Shen

    In this study we report a new concept of printing low-cost two-dimensional micro-zone plates for chemical and biochemical assays and ELISA. It is different from the concept of forming multi-zone micro-zones on paper by hydrophobic barriers first reported by Yagoda. Instead, the desired multi-zone micro-zone pattern was first printed using a UV-curable varnish onto a polymer film; then fine powders of cellulose or other materials were applied onto the uncured varnish, allowing the powder to stick to the varnish layer. After UV-curing, the powder particles were fixed by the cured varnish, leading to the formation of porous, water absorbing micro-zones on the polymer film. This type of micro-zone plate has the required liquid handling capacity for a variety of low-volume and portable two-dimensional plates for chemical, biochemical assays and ELISA. By suitably spacing porous micro-zones on a non-porous substrate, this type of plate eliminates inter-zone sample leaking. Rapid colorimetric analysis of the results can be performed using a portable battery-powered colour densitometer or a desktop scanner. By introducing a refractive-index-matching liquid into the micro-zones, the plate can be easily analyzed using transmission instruments. A major advantage of this plate fabrication method is that it enables the printing of different powders or functionalized powders to form micro-zones on a same plate, potentially allowing certain more difficult functionalization of materials to be performed before printing. We demonstrate the assaying performance of the plates using an analytical system that aims to clarify the analytical interference between NO2 − and uric acid (UA) in the analysis of samples where both chemical species are present. We also show that ELISA assays can be performed using this type of plates.


  • Flow control concepts for thread-based microfluidic devices

    by David R. Ballerini, Xu Li, Wei Shen

    The emerging concept of thread-based microfluidics has shown great promise for application to inexpensive disease detection and environmental monitoring. To allow the creation of more sophisticated and functional thread-based sensor designs, the ability to better control and understand the flow of fluids in the devices is required. To meet this end, various mechanisms for controlling the flow of reagents and samples in thread-based microfluidic devices are investigated in this study. A study of fluid penetration in single threads and in twined threads provides greater practical understanding of fluid velocity and ultimate penetration for the design of devices. “Switches” which control when or where flow can occur, or allow the mixing of multiple fluids, have been successfully prototyped from multifilament threads, plastic films, and household adhesive. This advancement allows the fabrication of more functional sensory devices which can incorporate more complex detection chemistries, while maintaining low production cost and simplicity of construction.


  • An inexpensive thread-based system for simple and rapid blood grouping

    by David R. Ballerini, Xu Li, Wei Shen

    This study investigates the use of thread as a flexible and low-cost substrate for the rapid grouping of blood. The use of a capillary substrate such as thread for blood grouping utilises the sensitivity of the flow resistance of large particles in narrow capillary channels to separate agglutinated red blood cells (RBCs) from plasma. Large and discrete particles formed in a continuous liquid phase do not provide capillary wicking driving force and fall behind the capillary wicking front, leading to their separation from the wicking liquid. The capillary substrate therefore provides a very promising but different mechanism for the separation of the agglutinated RBCs and the blood serum phase compared to most existing blood grouping methods. The principle of chromatographic separation is also exploited in this study via the use of suitable dyes to enhance the visual detection of the agglutinated RBCs and the serum phase; surprising and encouraging outcomes are obtained. Using a thread-based device, the ABO and Rh groups can be successfully determined with only 2 μL of whole blood from a pricked finger tip within 1 min and without pre-treatment of the blood sample. It is hoped that a new, inexpensive, rapid and simple method may provide an easy-to-use blood grouping platform well suited to those in developing or remote regions of the world.


  • Capillary driven low-cost V-groove microfluidic device with high sample transport efficiency

    by Junfei Tian, Dushmantha Kannangara, Xu Li, Wei Shen

    In this study we investigate the liquid sample delivery speed and the efficiency of microfluidic channels for low-cost and low-volume diagnostic devices driven only by capillary forces. We select open, non-porous surface grooves with a V-shaped cross section for modeling study and for sensor design. Our experimental data of liquid wicking in V-grooves show an excellent agreement with the theoretical data from the V-groove model of Rye et al. This agreement allows us to quantitatively analyze the liquid wicking speed in V-grooves. This analysis is used to generate data for the design of sensors. By combining V-groove channels and printable paper-like porous detection zones, microfluidic diagnostic sensors can be formed. Non-porous V-grooves can be fabricated easily on polymer film. Suitably long surface V-grooves allow short liquid transport time (< 500 ms), thus reducing the evaporation loss of the sample during transport. Non-porous V-grooves also significantly reduce chromatographic loss of the sample during transport, therefore increasing the sample delivering efficiency. Sensors of such design are capable of conducting semi-quantitative chemical and biochemical analysis (i.e. with a calibration curve) with less than 1000 nL of sample and indicator solution in total.


  • Liquid marble for gas sensing

    by Junfei Tian, Tina Arbatan, Xu Li, Wei Shen

    The porous and superhydrophobic shell of a liquid marble prevents contact of its liquid core with outside surfaces, but allows gas transport. Liquid marble can therefore be used to sense gas or emit gas. Liquid marbles loaded with different indicators can simultaneously sense different gases via different mechanisms.


  • An analysis of the thermodynamic conditions for solid powder particles spreading over liquid surface

    by Thanh H. Nguyen, Nicky Eshtiaghi, Karen P. Hapgood, Wei Shen


  • Thread as a Versatile Material for Low-Cost Microfluidic Diagnostics

    by Xu Li, Junfei Tian, Wei Shen

    This paper describes a new and simple concept for fabricating low-cost, low-volume, easy-to-use microfluidic devices using threads. A thread can transport liquid via capillary wicking without the need of a barrier; as it is stainable, it is also a desirable material for displaying colorimetric results. When used in sewing, threads have 3D passageways in sewed materials. The wicking property and flexibility of thread make it particularly suitable to fabricate 3D microfluidic devices. Threads can also be used with other materials (e.g., paper) to make microfluidic devices for rapid qualitative or semiquantitative analysis. These thread-based and thread-paper-based devices have potential applications in human health diagnostics, environmental monitoring, and food safety analysis, and are particularly appropriate for the developing world or remote areas, because of their relatively low fabrication costs.