Rodney S. Ruoff
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rodney S. Ruoff has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Nicola Maria Pugno
Mechano-X Labs, University of Trento
3 shared publications W. Ding
Northwestern University
3 shared publicationsX. Chen
Northwestern University
3 shared publicationsD. A. Dikin
Department of Mechanical Engineering, Northwestern University, Evanston, USA
2 shared publications- Dong Qian
Department of Mechanical Engineering, The University of Texas at Dallas, Richardson, TX
2 shared publications Min-Feng Yu
Department of Physics, Washington University in St. Louis, St. Louis, Missouri 63130
2 shared publications
Latest Publications
- 3 January 2008
- Published by Springer Nature
- p. 707-708
Fracture Mechanics of One-Dimensional Nanostructures
- 3 January 2008
- Published by Springer Nature
- p. 707-708
Fracture Mechanics of One-Dimensional Nanostructures
- 12 June 2007
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 18 (7) , 2067-2073
Correction factors for 4-probe electrical measurements with finite size electrodes and material anisotropy: a finite element study
In four- probe ( 4- probe) electrical measurements, especially on highly resistive materials, it is not always possible to configure the electrodes such that the current density is uniform throughout the sample. Under such circumstances, simply considering the material's electrical resistivity to be proportional to the measured resistance with the proportionality constant given by the sample geometry can give an incorrect result. In this paper, a numerical finite element model is presented which can extract a material's true resistivity from co- linear 4- probe electrical measurements on highly resistive samples with large electrodes that extend across the sample width. The finite element model is used to investigate the influence of material anisotropy, the resistance of the sample - electrode interfaces and the relative electrode- to- sample size on the potential and current density distributions in the sample. A correction factor is introduced to account for the impact of these effects on the measured resistivity. In the limit of large interface resistance, excellent agreement is found with an analytical expression derived elsewhere ( Esposito et al 2000 J. Appl. Phys. 88 2724 - 9). The approach presented here can be used to evaluate a variety of effects on co- linear 4- probe electrical measurements, can be extended to complex specimen geometries with arbitrary electrode arrangements and, additionally, could find use in the evaluation of data from 4- probe thermal conductivity measurements.
- 12 June 2007
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 18 (7) , 2067-2073
Correction factors for 4-probe electrical measurements with finite size electrodes and material anisotropy: a finite element study
In four- probe ( 4- probe) electrical measurements, especially on highly resistive materials, it is not always possible to configure the electrodes such that the current density is uniform throughout the sample. Under such circumstances, simply considering the material's electrical resistivity to be proportional to the measured resistance with the proportionality constant given by the sample geometry can give an incorrect result. In this paper, a numerical finite element model is presented which can extract a material's true resistivity from co- linear 4- probe electrical measurements on highly resistive samples with large electrodes that extend across the sample width. The finite element model is used to investigate the influence of material anisotropy, the resistance of the sample - electrode interfaces and the relative electrode- to- sample size on the potential and current density distributions in the sample. A correction factor is introduced to account for the impact of these effects on the measured resistivity. In the limit of large interface resistance, excellent agreement is found with an analytical expression derived elsewhere ( Esposito et al 2000 J. Appl. Phys. 88 2724 - 9). The approach presented here can be used to evaluate a variety of effects on co- linear 4- probe electrical measurements, can be extended to complex specimen geometries with arbitrary electrode arrangements and, additionally, could find use in the evaluation of data from 4- probe thermal conductivity measurements.
- 1 February 2007
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 101 (3) , 034316
Effect of cantilever nonlinearity in nanoscale tensile testing
Microcantilevers are widely used in micro-/nanoscale mechanics studies. The nonlinear response of a cantilever at large deflection is sometimes overlooked. A general study of cantilever beam nonlinearity under a variety of loading conditions was performed with analytical and finite element analyses. Analytical equations for the applied load and the cantilever deflection were obtained. The cantilever nonlinearity was found to increase with increasing cantilever deflection and/or angle of loading. Tensile tests were performed on templated carbon nanotubes (TCNTs) with a custom-made nanomanipulator inside a scanning electron microscope. Atomic force microscope (AFM) cantilevers were used to load the TCNTs and sense the force. During the tests the AFM cantilevers were loaded to relatively large deflections with nonvertical loads applied at the AFM tip. Based on the slope and the loading angle measurements, the breaking forces of the TCNTs were obtained through numerical integration of the analytical equations. A comparison was made between the load results obtained from linear and nonlinear analyses. The linear analysis was found to underestimate the applied load by up to 15%.
- 1 February 2007
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 101 (3) , 034316
Effect of cantilever nonlinearity in nanoscale tensile testing
Microcantilevers are widely used in micro-/nanoscale mechanics studies. The nonlinear response of a cantilever at large deflection is sometimes overlooked. A general study of cantilever beam nonlinearity under a variety of loading conditions was performed with analytical and finite element analyses. Analytical equations for the applied load and the cantilever deflection were obtained. The cantilever nonlinearity was found to increase with increasing cantilever deflection and/or angle of loading. Tensile tests were performed on templated carbon nanotubes (TCNTs) with a custom-made nanomanipulator inside a scanning electron microscope. Atomic force microscope (AFM) cantilevers were used to load the TCNTs and sense the force. During the tests the AFM cantilevers were loaded to relatively large deflections with nonvertical loads applied at the AFM tip. Based on the slope and the loading angle measurements, the breaking forces of the TCNTs were obtained through numerical integration of the analytical equations. A comparison was made between the load results obtained from linear and nonlinear analyses. The linear analysis was found to underestimate the applied load by up to 15%.
Bond–Detach Lithography: A Method for Micro/Nanolithography by Precision PDMS Patterning
We have discovered a micro/nanopatterning technique based on the patterning of a PDMS membrane/film, which involves bonding a PDMS structure/stamp (that has the desired patterns) to a PDMS film. The technique, which we call “bond–detach lithography”, was demonstrated (in conjunction with other microfabrication techniques) by transferring several micro‐ and nanoscale patterns onto a variety of substrates. Bond–detach lithography is a parallel process technique in which a master mold can be used many times, and is particularly simple and inexpensive.
Bond–Detach Lithography: A Method for Micro/Nanolithography by Precision PDMS Patterning
We have discovered a micro/nanopatterning technique based on the patterning of a PDMS membrane/film, which involves bonding a PDMS structure/stamp (that has the desired patterns) to a PDMS film. The technique, which we call “bond–detach lithography”, was demonstrated (in conjunction with other microfabrication techniques) by transferring several micro‐ and nanoscale patterns onto a variety of substrates. Bond–detach lithography is a parallel process technique in which a master mold can be used many times, and is particularly simple and inexpensive.
- 1 August 2006
- Published by Springer Nature in Experimental Mechanics
- Vol. 47 (1) , 25-36
Modulus, Fracture Strength, and Brittle vs. Plastic Response of the Outer Shell of Arc-grown Multi-walled Carbon Nanotubes
- 1 August 2006
- Published by Springer Nature in Experimental Mechanics
- Vol. 47 (1) , 25-36
Modulus, Fracture Strength, and Brittle vs. Plastic Response of the Outer Shell of Arc-grown Multi-walled Carbon Nanotubes
- 31 July 2006
- Published by Elsevier in Composites Science and Technology
- Vol. 66 (9) , 1099-1101
Special issue on nanocomposites
- 31 July 2006
- Published by Elsevier in Composites Science and Technology
- Vol. 66 (9) , 1099-1101
Special issue on nanocomposites
- 2 May 2006
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 103 (18) , 6779-6780
Time, temperature, and load: The flaws of carbon nanotubes
- 2 May 2006
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 103 (18) , 6779-6780
Time, temperature, and load: The flaws of carbon nanotubes
- 1 May 2006
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 77 (5) , 056103
Analysis of a microelectromechanical system testing stage for tensile loading of nanostructures
A new analytical model is developed for interpreting tensile loading data on “templated carbon nanotubes” (T-CNTs, amorphous carbon nanotubes made by pyrolysis with the channels of nanopores in anodized alumina nanopore arrays) obtained with a microelectromechanical-system (MEMS)-based mechanical testing stage. It is found that the force output from the actuation unit of the testing stage depends on the stiffness of the force sensing beam and the nanostructure being loaded, as well as the power input. A superposition method is used to treat the mechanics of the device structure in the linear elasticity response regime. To our knowledge this is a new approach for solving the mechanical response of MEMS structures with variable force output and of the configuration described herein. An in situ mechanical testing of individual T-CNTs was undertaken in a scanning electron microscope (LEO1525) using a new device fabricated with integrated electrodes for controlled deposition of T-CNTs by electric-field guided assembly in a liquid. The T-CNT was subsequently tensile loaded to the point of fracture. The calculated modulus of the T-CNT using the new model based on the experimentally measured displacement of the moving platform with and without the T-CNT attached falls within the range expected for amorphous carbon. The new model corrects the treatment in a previously presented model [S. Lu et al., Rev. Sci. Instrum. 75, 2154 (2004)].
- 1 May 2006
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 77 (5) , 056103
Analysis of a microelectromechanical system testing stage for tensile loading of nanostructures
A new analytical model is developed for interpreting tensile loading data on “templated carbon nanotubes” (T-CNTs, amorphous carbon nanotubes made by pyrolysis with the channels of nanopores in anodized alumina nanopore arrays) obtained with a microelectromechanical-system (MEMS)-based mechanical testing stage. It is found that the force output from the actuation unit of the testing stage depends on the stiffness of the force sensing beam and the nanostructure being loaded, as well as the power input. A superposition method is used to treat the mechanics of the device structure in the linear elasticity response regime. To our knowledge this is a new approach for solving the mechanical response of MEMS structures with variable force output and of the configuration described herein. An in situ mechanical testing of individual T-CNTs was undertaken in a scanning electron microscope (LEO1525) using a new device fabricated with integrated electrodes for controlled deposition of T-CNTs by electric-field guided assembly in a liquid. The T-CNT was subsequently tensile loaded to the point of fracture. The calculated modulus of the T-CNT using the new model based on the experimentally measured displacement of the moving platform with and without the T-CNT attached falls within the range expected for amorphous carbon. The new model corrects the treatment in a previously presented model [S. Lu et al., Rev. Sci. Instrum. 75, 2154 (2004)].